AD7874BR - 12-Bit 4-Channel Simultaneous ADC | Analog Devices
MPN: AD7874BR ✗ 停產AD7874BR 概覽
A simultaneous-sampling data acquisition system is a specialized ADC architecture that captures several inputs with a shared conversion sequence rather than multiplexing channels over separate time windows. This preserves the timing relationship between measured signals. The AD7874 applies this architecture to four inputs, making it useful for synchronized measurement systems in which channel-to-channel skew would otherwise distort the result.
Core features include four simultaneous input channels, 12-bit conversion resolution, a 116 kSPS maximum sampling rate, an internal reference, an internal clock, and four track-and-hold amplifiers. According to the Analog Devices datasheet, the device is also specified for conventional dc accuracy characteristics such as linearity, full-scale error, and offset error, as well as dynamic performance including distortion and signal-to-noise ratio.
The AD7874 uses an LC2MOS process, combining analog sampling and digital conversion functions in a compact integrated data acquisition system. Its parallel output architecture provides 12-bit conversion data and control signals to a digital acquisition system. Because four channels are sampled simultaneously, the device can support phase-sensitive measurements, multichannel instrumentation, vibration analysis, and synchronized process monitoring without relying on sequential analog multiplexing.
Typical uses include industrial process control, data loggers, laboratory instrumentation, vibration monitoring, communications equipment, and other multichannel measurement systems. The on-chip reference and clock reduce external circuit requirements, while the track-and-hold amplifiers preserve each sampled input during the conversion interval.
Designers should use the manufacturer pin-description table when assigning PCB tracks because the complete AD7874BR pinout is not reproduced here. Layout should preserve analog signal integrity, provide suitable grounding, and keep sensitive input and reference connections away from fast digital outputs. Supply and decoupling recommendations should follow the datasheet’s specified operating limits and reference circuitry.
This page combines manufacturer specifications, sourcing guidance, replacement considerations, comparison parameters, and practical integration notes. It also distinguishes true pin-compatible replacements from functional equivalents that would require different boards, software, or signal-conditioning changes, helping engineers evaluate AD7874BR alternatives before committing a design.
直接替換替代品,適用於 AD7874BR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
AD7874BRZ
✅ 直接替換📋 參考替代品(不在目錄中)
ADC122S625CIMM/NOPB
✅ 直接替換📋 參考替代品(不在目錄中)
AD7874BR 最大額定值與電氣特性
| Product Type | 4-channel simultaneous-sampling data acquisition system |
| Converter Resolution | 12 bit |
| Number of ADC Channels | 4 channels |
| Sampling Mode | Simultaneous sampling |
| Maximum Sampling Rate | 116 kSPS |
| ADC Architecture | 12-bit flash ADC |
| On-Chip Reference | Included |
| On-Chip Clock | Included |
| Track-and-Hold Amplifiers | 4 amplifiers |
| 介面類型 | Parallel |
| 供應電壓 | 5 V |
| Process Technology | LC2MOS |
| 封裝 | 28-pin SOIC |
| Package Width | 7.50 mm |
| 安裝類型 | Surface mount |
| Dynamic Performance Specifications | Distortion and signal-to-noise ratio |
| DC Accuracy Specifications | Linearity, full-scale error, and offset error |
| Reference Input/Output Capability | Supports sharing one reference source among multiple AD7874 devices |
AD7874BR 7.50 mm 腳位配置指南
AD7874BR(7.50 mm 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7874BR.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7874BR 適用於 6 應用s: Synchronized Vibration Monitoring, Industrial Process Control, Laboratory Data Acquisition, Communications Signal Monitoring, Power-System Diagnostics, Data Logging and Instrumentation.
Synchronized Vibration Monitoring
The AD7874BR fits vibration systems that compare the phase and amplitude of four mechanically related signals. Its four simultaneous channels preserve relative timing that would be degraded by sequential multiplexing, and the 12-bit conversion resolution supports measurement across a 116 kSPS operating rate. The four track-and-hold amplifiers acquire each channel at the same instant, allowing the digital system to calculate phase relationships without a time-skew correction. A practical implementation should use short analog traces, a solid ground plane, and sampling synchronized to the mechanical excitation. The principal design constraint is that sensor outputs must remain within the AD7874 input range and satisfy the acquisition bandwidth required for the vibration frequencies being measured.
推薦
Industrial Process Control
The AD7874BR can monitor four related process variables when their timing must be correlated. Its simultaneous-sampling architecture is useful for pressure, temperature, level, and actuator feedback acquired from the same process event, while the on-chip reference and clock reduce the number of external support components. The 12-bit ADC and operation up to 116 kSPS provide adequate resolution and throughput for supervisory control loops and event logging. In a plant-oriented design, place the analog inputs away from switching supplies and digital clock returns, and use consistent channel conditioning. Engineers should verify that the selected sensors, filters, and protection networks preserve the required accuracy while keeping every input within the converter’s specified operating limits.
推薦
Laboratory Data Acquisition
The AD7874BR suits laboratory instruments that must capture several inputs with a common time reference. Four simultaneous channels avoid the timing uncertainty introduced by sequential conversion, while the parallel interface supports direct connection to digital acquisition logic. At 12-bit resolution and up to 116 kSPS, the device can measure repetitive waveforms, control-loop signals, and transient events whose phase relationship matters. A useful implementation separates sensitive analog inputs from the 12-bit parallel bus and uses controlled grounding between the converter and processor. For higher-accuracy measurement channels, engineers can evaluate other ADI converters, but the AD7874BR remains appropriate when simultaneous acquisition and the established AD7874 behavior are the priorities.
推薦
Communications Signal Monitoring
The AD7874BR is appropriate for communications test systems that need to observe several baseband or control signals against a shared time base. Simultaneous conversion preserves the relative phase of the four channels, while the on-chip clock and reference help simplify deterministic acquisition. The 12-bit converter operates up to 116 kSPS, making it suitable for many low- and medium-bandwidth monitoring tasks rather than high-rate radio sampling. In implementation, isolate the analog section from high-energy clock and transmit paths, maintain a continuous reference return, and terminate unused inputs according to the datasheet guidance. The system designer should verify input bandwidth, settling time, and dynamic range against the modulation being monitored.
推薦
Power-System Diagnostics
The AD7874BR can acquire voltage, current, and timing-related signals when a power system requires synchronized measurements. Four track-and-hold amplifiers sample the inputs together, reducing channel skew during comparisons of phase, pulse timing, or transient behavior. The 12-bit resolution and 116 kSPS rate suit slower diagnostic waveforms and supervisory protection functions. A practical design should scale sensor outputs safely, protect each analog input against transients, and route the parallel digital interface away from sensitive current-shunt measurements. Because the AD7874BR is obsolete, new instruments should also evaluate current ADC families when long-term availability is a higher priority than preserving an existing AD7874-based signal chain.
推薦
Data Logging and Instrumentation
The AD7874BR supports compact multichannel instruments that record four analog measurements with a common acquisition time. Its integrated reference, clock, and track-and-hold amplifiers reduce the analog subsystem size, while the parallel interface provides straightforward timing at moderate data rates. A logger can use the device for recurring process snapshots, machine diagnostics, or transient records where channel alignment is more important than very high throughput. The design should use a low-noise analog ground strategy, route the clock away from sensitive inputs, and buffer sensor outputs when their source impedance is too high for the track-and-hold amplifier. Firmware must also account for the ADC conversion sequence and ensure that the digital acquisition system captures all 12 bits consistently.
推薦
推薦產品摘要
工程參考資料,適用於 AD7874BR — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7874BRZ | ADC122S625CIMM/NOPB |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Texas Instruments |
| Package | 28-pin SOIC | 28-pin SOIC | 28-pin SOIC |
| Resolution | 12 bit | 12 bit | 12 bit |
| Sampling Rate | 116 kSPS | 116 kSPS | 116 kSPS |
| Interface | Parallel | Parallel | Parallel |
主要差異化特點
- Documented four-channel simultaneous-sampling architecture (對比ADC122S625CIMM/NOPB)
- Integrated reference and acquisition clock (對比ADC122S625CIMM/NOPB)
- Matching established Analog Devices function set (對比ADC122S625CIMM/NOPB)
設計說明
Route the four analog inputs as short, isolated traces and place their conditioning or protection components close to the AD7874BR. Keep the parallel data bus away from the analog inputs and reference circuitry to reduce coupling from the digital switching edges. Use a continuous ground plane beneath the device, maintain the datasheet-specified decoupling arrangement, and verify the decoupling capacitors close to their associated supply and ground pins.
Account for acquisition settling, source impedance, and channel timing when assigning sensor signals. The four track-and-hold amplifiers sample simultaneously, but the complete acquisition chain still requires adequate bandwidth and low source impedance at the inputs. Use the manufacturer’s pin-description and application guidance when handling unused channels and confirm that every connected signal stays within the specified input range. Test channel-to-channel skew with a common source where phase accuracy is important.
Do not treat the AD7874BR and AD7874BRZ ordering suffixes as evidence of different electrical performance, but do verify the exact suffix before procurement. More importantly, do not assume that matching the 28-pin SOIC package, 12-bit resolution, and 116 kSPS headline rate guarantees interchangeability. For ADC122S625CIMM/NOPB, compare pin names, reference voltage, analog input range, clock behavior, conversion timing, output coding, and control logic against the original AD7874 design before substitution.
合規資訊
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact AD7874BR ordering code. AEC-Q100 is not applicable to this general-purpose data acquisition IC.