AD7876BQ - 12-Bit 100 kHz Sampling ADC | Analog Devices
MPN: AD7876BQ ✓ 啟用中AD7876BQ 概覽
A sampling ADC is a data-conversion IC that samples an analog voltage and converts it into a numeric code for processing by a microprocessor, microcontroller, or digital signal processor. The AD7876 belongs to the ADC hierarchy, within the broader category of data-converter and mixed-signal semiconductors. It combines acquisition and conversion functions in one device while allowing the host processor to determine when the conversion result should be transferred.
The AD7876 supports a 12-bit conversion resolution and a maximum sampling rate of 100 kSPS. Its successive-approximation architecture is supported by a self-contained, laser-trimmed internal clock and an integrated track-and-hold amplifier. The buried-Zener reference provides the converter with an internal 3 V reference, while the interface logic supports microprocessor-oriented parallel and serial data-transfer arrangements described for the AD7870, AD7875, and AD7876 family.
The 100 kSPS throughput makes the AD7876 suitable for sampling control signals, transducers, industrial process variables, and lower-bandwidth waveforms. The 10 V input range allows direct interfacing to many industrial sensors when the signal remains within the converter's input and common-mode limits. Because this is a 12-bit converter, the ideal quantization interval is one part of 4096, although real accuracy also depends on reference, noise, source impedance, acquisition timing, and board layout.
Because the converter and acquisition circuitry operate at 100 kSPS, signal-source settling and PCB trace matching directly influence conversion accuracy. Place input, reference, and ground connections close to their associated pins, maintain a low-impedance return path, and avoid routing the analog input through noisy switching-regulator areas. The manufacturer datasheet should be used for the complete pin-description table, timing diagrams, acquisition requirements, and electrical limits.
This page combines the manufacturer's core device information with practical interface guidance, verified package details, sourcing information, and same-footprint family alternatives. It is intended to help engineers evaluate the AD7876BQ for data-acquisition, industrial control, instrumentation, and embedded processing systems without losing sight of the original circuit-design constraints.
直接替換替代品,適用於 AD7876BQ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD7876BQ (相同外形與佔位) — 差異在於 Clock, Mounting Type, Package.
AD7876BN
✅ 直接替換聯絡詢價
查看資料表 →AD7876BNZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD7876BQ 最大額定值與電氣特性
| Converter Type | Successive-approximation sampling ADC |
| 解析度 | 12 bit |
| Maximum Sampling Rate | 100 kSPS |
| Conversion Time | 8 µs |
| Input Signal Range | Up to 10 V |
| Internal Reference Voltage | 3 V |
| Reference Architecture | Buried-Zener reference |
| Acquisition Architecture | Integrated track-and-hold amplifier |
| Clock | Self-contained internal clock |
| Clock Trim | Laser-trimmed internal clock |
| Data Interface | Parallel or serial data output |
| 封裝 | 24-pin small-outline IC package |
| 安裝類型 | Surface mount |
| Converter Function | Complete analog-to-digital converter on one chip |
AD7876BQ 24-pin small-outline ic package 腳位配置指南
AD7876BQ(24-pin small-outline ic package 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7876BQ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7876BQ 適用於 6 應用s: Industrial Process Monitoring, Programmable Control Systems, Data-Acquisition Instruments, Power and Equipment Control, Embedded Sensor Acquisition, Communication and Interface Modules.
Industrial Process Monitoring
The AD7876BQ is suited to industrial process monitoring because it combines 12-bit resolution, a 100 kSPS sampling rate, and an input range up to 10 V. Place the converter at the input of a controller or data-acquisition module to digitize a conditioned pressure, temperature, or position signal. Its 8 µs conversion time supports rapid sampling, while the integrated track-and-hold amplifier and 3 V buried-Zener reference reduce external circuitry. Design the analog front end so the source settles within the acquisition window, and route analog ground and reference connections away from high-current switching nodes.
推薦
Programmable Control Systems
The AD7876BQ can serve as the fast analog input stage of a programmable controller by converting sensor commands or feedback voltages into 12-bit codes for a microprocessor or microcontroller. Its 100 kSPS maximum throughput permits sampling more frequently than many slow control loops require, while the parallel and serial interface options support different processor architectures. Treat the 10 V capability as a maximum signal range rather than a universal input tolerance, and include clamping, scaling, and filtering when the external signal can exceed the converter's specified operating limits.
推薦
Data-Acquisition Instruments
For laboratory and industrial data-acquisition instruments, the AD7876BQ combines conversion speed, digital output control, and an internal reference in one 24-pin package. A 100 kSPS sampling rate is useful for waveforms that require more temporal resolution than a low-rate precision ADC provides. The 12-bit result supports 4096 ideal codes, making correct reference routing and low-noise layout essential to meaningful measurement resolution. Use separate analog and digital return paths, provide local bypass capacitance at the supply and reference pins, and follow the acquisition timing shown in the manufacturer datasheet.
推薦
Power and Equipment Control
The AD7876BQ is applicable to power and equipment control boards that must monitor analog feedback signals with a compact, high-speed converter. Its up-to-10 V input range simplifies interfaces to scaled current or voltage sensing networks, provided every operating limit is observed. The integrated internal clock reduces the need for an external timing source, while interface logic supports host-processor acquisition. At the system level, add protection against transients and verify the source impedance because long acquisition times can limit the effective rate when the driving network has excessive capacitance.
推薦
Embedded Sensor Acquisition
The AD7876BQ can form the conversion stage of an embedded sensor-acquisition chain when a sensor output is scaled into the converter's allowable range. Its 100 kSPS rate supports fast-changing analog quantities, and the integrated track-and-hold amplifier, internal reference, and clock minimize the number of supporting components. The 12-bit conversion resolution should be matched to sensor accuracy, amplifier offset and noise, and the required control-loop resolution. Buffer very high-impedance sensors when their settling behavior cannot satisfy the converter's acquisition requirements.
推薦
Communication and Interface Modules
The AD7876BQ is suitable for interface modules that need to acquire an analog command or supervisory signal before digital transmission. Its 12-bit resolution provides 4096 ideal code levels, and the 100 kSPS rate is ample for many monitoring, calibration, and slow-waveform tasks. The internal clock and flexible interface logic simplify connection to modern processors and digital signal processors. Keep the analog input short, decouple the reference correctly, and establish a controlled grounding strategy so digital communication activity does not degrade the measured signal.
推薦
推薦產品摘要
工程參考資料,適用於 AD7876BQ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7876BN | AD7876BNZ |
|---|---|---|---|
| Package | 24-pin small-outline IC package | 24-pin small-outline IC package | 24-pin small-outline IC package |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 12 bit | 12 bit | 12 bit |
| Maximum Sampling Rate | 100 kSPS | 100 kSPS | 100 kSPS |
| Conversion Time | 8 µs | 8 µs | 8 µs |
| Input Signal Range | Up to 10 V | Up to 10 V | Up to 10 V |
| Internal Reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference |
| Acquisition Circuit | Integrated track-and-hold amplifier | Integrated track-and-hold amplifier | Integrated track-and-hold amplifier |
| Clock | Self-contained laser-trimmed internal clock | Self-contained laser-trimmed internal clock | Self-contained laser-trimmed internal clock |
主要差異化特點
- Complete converter integration (對比AD7876BN)
- 100 kSPS sampling throughput (對比AD7876BNZ)
- 24-pin small-outline PCB reuse (對比AD7876BN)
設計說明
Do not treat the stated 10 V input range as permission to exceed the absolute maximum ratings. Use the exact analog-input limits, common-mode range, and supply limits in the manufacturer datasheet. Add appropriate input scaling and protection for sensors, transients, or fault conditions that could exceed those limits, and verify the source remains valid during acquisition rather than only at steady state.
Preserve acquisition accuracy by minimizing the impedance seen at the analog input and keeping the input trace short. The track-and-hold amplifier must acquire the source voltage within the device's specified settling window. If the sensor or divider network has high source impedance or excessive capacitance, add an appropriate buffer and keep the buffer's output path compact; otherwise, the achieved conversion rate may be lower than the nominal 100 kSPS.
Separate analog and digital return paths, place local bypass capacitors at the supply and reference pins, and route the analog input away from clock, data-bus, and power-converter traces. Use a continuous ground reference beneath the converter where the package construction permits, and avoid placing test points or high-current return paths adjacent to the input and reference connections. These layout practices reduce code noise and timing variation during successive-approximation conversion.
合規資訊
No specific environmental or material-compliance declarations were identified for this ordering code. Confirm RoHS, REACH, lead-free, halogen-free, and automotive qualification status from the current manufacturer product documentation and declaration files.