Analog Devices

AD8513AR - Precision Quad JFET Op Amp | Analog Devices

MPN: AD8513AR ✗ 停產
1800 uV maximum Vdss 14-pin SOIC Package
MOQ: 1 |

AD8513AR 概覽

The Analog Devices AD8513AR is a precision, low-noise JFET operational amplifier in a 14-pin SOIC package. It contains four amplifiers and combines low offset voltage, very low input bias current, low voltage noise, and low current noise for accurate signal conditioning. The AD8513AR is particularly suited to high-impedance sensors, precision shunt measurements, medical instrumentation, electronic measurement, and automated test equipment.

An operational amplifier is an active analog signal-conditioning device that uses high open-loop gain to amplify differential inputs. A JFET-input operational amplifier is a subtype in which junction field-effect transistors form the input stage. This input architecture provides very low input bias current, making the AD8513AR useful when measuring signals from sources with high output impedance or when preserving the accuracy of a small sensor current.

The AD8513 family combines DC precision, low noise, and fast settling behavior. Its low input bias current reduces the DC error introduced when the amplifier draws current from a high-impedance source. Low input voltage noise is important when the source signal is small, while low input current noise benefits current-measurement and transimpedance circuits. These characteristics allow one amplifier to serve precision analog acquisition, instrumentation, and test-system signal-chain functions.

The AD8513AR is the quad version of the AD8510, AD8512, and AD8513 precision JFET amplifier family. Multiple amplifiers in one package can reduce external component count and simplify board-level routing for filters, buffers, differential stages, and multi-channel measurement systems. The 14-pin SOIC package supports conventional surface-mount assembly, while the device’s electrical characteristics make it appropriate for both laboratory-grade and industrial precision analog designs.

Typical uses include pH and electrochemical sensor interfaces, photodiode and current-transimpedance amplifiers, precision shunt amplifiers, medical monitoring front ends, electronic test equipment, active filters, and general-purpose buffers. In a multi-channel instrument, four amplifiers can process several sensor outputs consistently, reducing board area compared with four separate single-amplifier packages.

Designers should verify the complete input and output voltage limits, common-mode range, supply configuration, stability, input capacitance, and load drive against the Analog Devices manufacturer datasheet before finalizing the circuit. Decoupling capacitors should be placed close to the supply pins, and source impedances must be evaluated for bias-current and noise errors. The device should not be treated as rail-to-rail solely because it is used with dual supplies.

This product page organizes the confirmed device identity, package, sourcing information, and practical application guidance. It also identifies the limits of the available comparison data so engineers can distinguish a genuine pin-compatible replacement from a related amplifier that merely belongs to the same product family or category.

直接替換替代品,適用於 AD8513AR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此產品無可直接替換的替代品。

申請替代品

AD8513AR 最大額定值與電氣特性

Amplifier Type Precision JFET operational amplifier
Number of Amplifiers 4 circuits
封裝 14-pin SOIC
安裝類型 Surface mount
Maximum Offset Voltage 1800 uV maximum

AD8513AR 14-pin soic 腳位配置指南

AD8513AR(14-pin soic 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

AD8513AR 的 14-pin soic 封裝腳位圖

無詳細腳位定義資料: AD8513AR.

請參閱 資料表 以查看完整腳位配置。

典型應用

AD8513AR 適用於 6 應用s: High-Impedance Sensor Signal Conditioning, Precision Shunt Current Measurement, Medical Monitoring Front End, Automated Test Equipment, Precision Active Filtering, Low-Noise Buffer and Amplifier.

🧩

High-Impedance Sensor Signal Conditioning

The AD8513AR fits high-impedance sensor interfaces because its JFET input stage is designed for very low input bias current, while low offset voltage and low input noise help preserve weak sensor signals. Place one amplifier as a non-inverting or differential buffer close to the sensor, then use the remaining channels for filtering or reference buffering. Keeping high-impedance input traces short reduces leakage and parasitic coupling. Confirm the actual input common-mode range and offset performance at the intended supply voltage before finalizing the gain and bias network.

⚡

Precision Shunt Current Measurement

The AD8513AR is appropriate for precise shunt-current measurement because low input bias current minimizes the DC error introduced into high-value sense resistors, and low input noise improves the readability of small differential voltages. Each channel can provide input offset correction or low-side voltage amplification around a shunt. The input network should use matched resistors and short Kelvin-style routes where possible. Supply voltage, input common-mode range, and amplifier-count requirements must be checked against the shunt voltage before the board layout is released.

💊

Medical Monitoring Front End

The AD8513AR can support medical monitoring front ends that combine low offset, low noise, and very low input bias current. The low-noise characteristics help retain small physiological signals, while the low-bias-current input stage is useful with high-impedance sensors. Four channels can acquire or condition several related signals within one package. The design must still account for medical-system isolation, protection, diagnostic requirements, and applicable regulatory validation outside the component’s basic analog performance.

🏭

Automated Test Equipment

The AD8513AR suits automated test equipment where DC accuracy, low noise, and fast settling behavior must coexist in a compact analog package. Four amplifiers can implement source drivers, difference amplifiers, buffers, and active filters for a multi-DUT test interface. Place the device near the measurement nodes to minimize trace noise and provide local supply bypassing. Verify settling performance for the selected gain, output amplitude, and load because the complete system requirement depends on the operating mode and external feedback network.

🔧

Precision Active Filtering

The AD8513AR can implement precision active filters when low input bias current, low noise, and low offset are important to the signal chain. Its four amplifiers provide enough channels for cascaded stages, balanced buffers, or multiple filter sections in one 14-pin SOIC. Select resistor and capacitor values with the amplifier’s noise and stability limits in mind, and keep feedback loops compact. The common-mode range and output capability must remain valid at every signal excursion rather than only at the nominal operating point.

📡

Low-Noise Buffer and Amplifier

The AD8513AR works well as a low-noise buffer or precision gain stage because it combines low offset voltage with low input voltage and current noise. Four channels can buffer several related inputs before digitization or further signal processing, reducing package count on space-constrained analog boards. Use short feedback paths and avoid floating high-impedance inputs, and observe the device’s input and output limits under the selected dual- or single-supply arrangement. The family’s low-noise characteristics make it especially useful for small signals that would otherwise be obscured by input-referred noise.

推薦產品摘要

AD8510 Single-channel member of the same precision JFET amplifier family 用於: High-Impedance Sensor Signal Conditioning, Precision Shunt Current Measurement, Medical Monitoring Front End, Automated Test Equipment, Precision Active Filtering, Low-Noise Buffer and Amplifier AD8512 Dual-channel member of the same precision JFET amplifier family 用於: High-Impedance Sensor Signal Conditioning, Precision Shunt Current Measurement, Medical Monitoring Front End, Automated Test Equipment, Precision Active Filtering, Low-Noise Buffer and Amplifier AD8513AR Analog Devices 用於: High-Impedance Sensor Signal Conditioning, Precision Shunt Current Measurement, Medical Monitoring Front End, Automated Test Equipment, Precision Active Filtering, Low-Noise Buffer and Amplifier
What is the AD8513AR?
The AD8513AR is a precision quad JFET operational amplifier from Analog Devices packaged in a 14-pin SOIC. According to the Analog Devices AD8510/AD8512/AD8513 manufacturer datasheet, the device combines low offset voltage, very low input bias current, low input voltage noise, and low input current noise. The four integrated amplifiers make it useful for multichannel precision signal conditioning, high-impedance sensor interfaces, and measurement systems.
Where can I download the AD8513AR datasheet PDF?
The AD8513AR datasheet PDF is available from Analog Devices at the official AD8510_8512_8513 datasheet link on this page. The document covers the single-, dual-, and quad JFET amplifier family, including the AD8513AR quad configuration. Use the manufacturer’s pin-description table and electrical-characteristics tables when assigning PCB nets and checking operating limits.
Where can I find the AD8513AR pinout?
The AD8513AR uses a 14-pin SOIC package, and its complete pin assignment is defined in the Analog Devices AD8510/AD8512/AD8513 manufacturer datasheet. Consult the pin-description table and package drawing before routing the PCB. Because four amplifiers share the package, confirm each amplifier’s input, output, supply, and no-connect positions on the selected package variant.
What are the key specifications engineers should know about AD8513AR?
The AD8513AR is a four-circuit precision JFET amplifier in a 14-pin SOIC package, with a listed maximum offset voltage of 1800 uV. According to the manufacturer datasheet, its defining characteristics are low offset voltage, very low input bias current, low voltage noise, and low current noise. The datasheet also describes fast settling behavior suitable for precision measurement and automated test equipment.
Is the AD8513AR suitable for high-impedance sensor amplification?
Yes, the AD8513AR is suitable for high-impedance sensor amplification because its JFET input stage provides very low input bias current. According to the Analog Devices manufacturer datasheet, this combination of low offsets, low noise, and low input bias current is especially effective for high-impedance sensors and precise shunt-current measurements. The source impedance and resulting bias-current error should still be included in the system error budget.
What is the difference between AD8513AR and AD8513ARZ?
The AD8513AR and AD8513ARZ are both identified as Analog Devices 14-SOIC, four-circuit JFET amplifiers, and both are associated with the AD8510/AD8512/AD8513 precision amplifier family. Their electrical function is closely related, while the ARZ suffix identifies a distinct ordering/package version. Confirm the exact ordering code and lead-finish requirements on the manufacturer product page before substitution.
AD8513AR vs AD8512ARZ: which is better for a multichannel amplifier?
Choose the AD8513AR when a design needs four amplifiers in one 14-pin SOIC, because it integrates four JFET operational-amplifier channels. The AD8512ARZ is a dual-amplifier configuration and would generally require two packages to provide four channels. The AD8513AR also supports the low-noise, low-bias-current characteristics highlighted in the Analog Devices manufacturer datasheet.
When should I choose AD8513AR instead of AD8512ARZ?
Choose the AD8513AR when board area, channel count, and matched integration favor a quad amplifier, such as four-channel sensor acquisition or multichannel filtering. Choose the AD8512ARZ when only two amplifier channels are required, allowing a smaller 8-pin SOIC footprint. Verify supply voltage, common-mode range, offset, noise, and stability requirements for the selected operating point before deciding.
Can AD8513ARZ replace AD8513AR in an existing PCB?
The AD8513ARZ is a close candidate for the AD8513AR because both appear as four-circuit, 14-SOIC JFET amplifiers in the Analog Devices product ecosystem. However, a replacement should be released only after the exact ordering information, electrical limits, pin table, and package drawing are compared. Request the latest manufacturer documentation through the Request a Quote form on this page.
What can replace the AD8513AR as a drop-in amplifier?
No fully documented drop-in replacement can be confirmed from the available manufacturer and distributor records. A valid replacement must match the 14-pin SOIC footprint, amplifier count, supply range, input and output limits, common-mode behavior, offset, noise, bias current, and stability requirements. Submit the operating conditions through the Request a Quote form for engineering review rather than relying on a package-only match.
Is there an equivalent amplifier from another manufacturer for AD8513AR?
No cross-manufacturer drop-in equivalent is confirmed by the available manufacturer and distributor information. Even though competing precision JFET amplifiers may share a 14-pin SOIC outline, electrical compatibility requires more than matching the footprint. Use the Request a Quote form on this page and provide the required supply voltage, bandwidth, noise, offset, common-mode, and load conditions for substitution review.
How do I reduce offset and noise in an AD8513AR circuit?
Use the AD8513AR within its specified supply and common-mode ranges, keep source impedances appropriate for a low-bias-current JFET input, and follow the manufacturer’s recommended decoupling and layout practices. Offset can be evaluated through the datasheet’s offset-voltage specifications, while noise depends on source resistance, bandwidth, and the amplifier’s input-voltage and input-current-noise terms. An offset-null arrangement should be used only if the circuit design permits it.
What power-supply and decoupling guidance applies to the AD8513AR?
Place the supply bypass capacitors close to the amplifier supply pins and keep the input, output, and feedback traces short. According to the Analog Devices manufacturer datasheet, the AD8513AR uses low noise and low bias current to support precision measurement, but correct supply routing remains essential for stable low-noise operation. Confirm the supported supply configurations and capacitor recommendations in the electrical-characteristics and application sections.
Where can I buy AD8513AR and what is its current price?
Use the Request a Quote form on this page to request AD8513AR availability, current pricing, and lot-specific lead time. The form connects the request to XAIPART without requiring a static price figure that could become stale. Confirm the exact AD8513AR ordering code, 14-pin SOIC packaging, shipment quantity, and traceability requirements when submitting the request.
Is AD8513AR in stock and what is the lead time?
Current AD8513AR inventory and lead time should be confirmed through the Request a Quote form on this page. Stock can vary by package, quantity, and shipment schedule, so distributor landing pages are not a reliable lot-level commitment. Include your required quantity, target date, and acceptable traceability requirements in the request for an actionable quotation.

工程參考資料,適用於 AD8513AR — 比較、設計指引及合規資訊。

選型指南

The AD8513AR is most appropriate when a design needs four precision JFET amplifier channels in one 14-pin SOIC, especially for high-impedance sensors, shunt measurements, medical monitoring, active filters, and automated test equipment. Its low offset, low voltage noise, low current noise, and very low input bias current make it useful where weak signals and source accuracy are more important than rail-to-rail operation or maximum channel density. The quad configuration can reduce package count, but it occupies more board area than a dual amplifier and does not eliminate the need to verify common-mode range, output swing, supply limits, stability, and noise at the intended operating point. No confirmed drop-in replacement is identified for the exact device. Related AD8510 and AD8512 family members provide one or two channels, respectively, but they are not drop-in substitutes for a four-channel PCB footprint. Before committing to a cross-manufacturer alternative, require an engineering review of the complete electrical and pin-level requirements.

與替代品比較

參數 本產品
Brand Analog Devices
Package 14-pin SOIC
Amplifier Count 4 amplifiers
Input Stage JFET
Maximum Offset Voltage 1800 uV
Primary Application Precision high-impedance signal conditioning

設計說明

Place input, output, and feedback components close to the AD8513AR and route sensitive input signals away from supply and clock traces. For high-impedance sources, minimize exposed PCB trace length and use a protective ground arrangement where appropriate. Because the amplifier is optimized for low input bias current, even small leakage paths can become significant when the source impedance is high.

Use the manufacturer-recommended supply bypassing arrangement and place bypass capacitors close to the package supply pins. Validate the selected power-supply topology against the AD8513AR operating limits before routing the board. When the amplifier operates near an input or output range boundary, include supply tolerance and startup transients in the design margin rather than relying only on the nominal rail voltage.

Do not assume rail-to-rail input or output operation, and do not substitute the amplifier solely because it uses the same 14-pin SOIC outline. Check amplifier count, supply range, input common-mode range, output swing, offset, noise, bias current, stability, and operating temperature. Also confirm whether the selected ordering suffix changes package finish or lead-free status without changing the electrical function.

For small-signal measurements, evaluate total input-referred noise using the amplifier’s voltage-noise and current-noise contributions together with source resistance. High-value feedback resistors can increase current-noise effects, while high source impedances can make bias current and leakage more important. Choose external resistor values that balance noise, bias error, bandwidth, and the amplifier’s stability requirements.

合規資訊

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

The exact AD8513AR ordering code and related ARZ ordering code appear in distributor records, but no explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was confirmed. Verify the current manufacturer product page or declaration before release.

資料驗證日期: 2026-11-26 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

AD8513AR datasheet AD8513AR pinout AD8513AR datasheet pdf AD8513AR specifications AD8513AR price AD8513AR stock Analog Devices AD8513AR AD8513AR 14-SOIC AD8513AR replacement AD8513AR equivalent AD8513AR vs AD8513ARZ AD8513AR vs AD8512ARZ AD8513AR application circuit AD8513AR high impedance sensor AD8513AR quad JFET amplifier

相關元件與詞彙

Analog Devices AD8513AR AD8513 AD8510 AD8512 AD8513ARZ precision JFET operational amplifier operational amplifier analog signal conditioner JFET input stage low offset voltage low input bias current input voltage noise input current noise precision shunt measurement high-impedance sensor medical monitoring automated test equipment active filter 14-pin SOIC SOIC package family surface-mount package Analog Devices AD8510/AD8512/AD8513 datasheet
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情