ADM3078EYRZ - 16Mbps RS-485/RS-422 Transceiver | ADI
MPN: ADM3078EYRZ ✓ 啟用中ADM3078EYRZ 概覽
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into balanced differential line signals and receives those differential signals back into digital logic. The ADM3078E belongs to the broader RS-485 and RS-422 interface hierarchy, where differential signaling improves noise immunity and allows communication across distances greater than those normally supported by single-ended links. Half-duplex operation allows the same bus pair to carry transmitted and received data, though direction must be controlled by the host.
Key features include a 16 Mbps maximum signaling rate, ±15 kV ESD protection on RS-485 inputs and outputs, true fail-safe receiver inputs, and hot-swap input structures on the driver-enable and receiver-enable controls. The device supports both RS-422 and RS-485 communication and can operate on multipoint bus transmission lines. These characteristics make it suitable for industrial control, factory automation, instrumentation, and embedded communications systems.
At 3.3 V operation, the ADM3078E family combines low-power interface performance with high data-rate capability. The ESD protection is intended to improve system survivability during cable installation and industrial transients, while the fail-safe receiver provides a defined output state when the bus is idle, undriven, or experiencing certain fault conditions. The exact input thresholds, output levels, propagation delays, and current consumption should be confirmed in the manufacturer data sheet before finalizing a timing- or power-sensitive design.
Typical uses include half-duplex multidrop buses connecting controllers to sensors, motion-control equipment, remote I/O modules, and test equipment. The 16 Mbps rate is particularly useful for short-distance, high-throughput links where an 8-pin SOIC implementation is preferred over larger isolated-interface packages. The same package can also be used in point-to-point RS-422 links when its receiver and driver controls are configured appropriately.
PCB design should provide a continuous return path between the transceiver ground and the system ground, keep bus traces short where high data rates are used, and place termination and protection components near the connector or transceiver as appropriate. Differential pair routing should maintain consistent geometry and avoid discontinuities that can degrade signal integrity. The device is not an isolated interface, so system designers must evaluate common-mode voltage, grounding, and surge-protection requirements independently.
直接替換替代品,適用於 ADM3078EYRZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADM3078EYRZ (相同外形與佔位) — 差異在於 Package, Driver Count, Fail-Safe Receiver, Product Type, Receiver Count.
ADM3078EARZ
✅ 直接替換聯絡詢價
查看資料表 →ADM3077EARZ
✅ 直接替換聯絡詢價
查看資料表 →SP3078EEN
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3078EYRZ 規格
| 供應電壓 | 3.3 V |
| Maximum Data Rate | 16 Mbps |
| ESD Protection | ±15 kV |
| Communication Standards | RS-485 and RS-422 |
| Duplex Mode | Half-duplex |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Maximum Bus Nodes | 256 nodes |
| Fail-Safe Receiver | True fail-safe receiver input |
| Hot-Swap Control Inputs | Supported on DE and RE controls |
| 工作溫度 | -40°C to +125°C temperature option |
| 封裝 | 8-pin SOIC, PDSO8 |
| 安裝類型 | Surface mount |
| Isolation | Non-isolated |
| Balanced Differential Signaling | Supported |
| Data Sheet Revision | Rev. F |
ADM3078EYRZ 8-pin soic, pdso8 腳位配置指南
ADM3078EYRZ(8-pin soic, pdso8 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ADM3078EYRZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADM3078EYRZ 適用於 6 應用s: Industrial Automation Multidrop Bus, Factory Sensor and Remote I/O, Test and Measurement Instrumentation, Motion and Position Control, Building Access and Security Control, Communication and Network Equipment.
Industrial Automation Multidrop Bus
The ADM3078EYRZ fits short, high-speed multidrop links connecting an industrial controller to remote I/O, actuator, or instrumentation nodes. Its 16 Mbps maximum data rate provides ample throughput for compact automation networks, while ±15 kV ESD protection on the RS-485 bus pins improves resilience during field wiring and maintenance. The device supports balanced differential signaling, true fail-safe receiver inputs, and as many as 256 nodes. In a half-duplex arrangement, the host must manage DE and RE control so only one transmitter drives the shared pair at a time. PCB routing should use a continuous ground return, controlled differential geometry, and minimal stubs to preserve the 16 Mbps signal integrity.
推薦
Factory Sensor and Remote I/O
The ADM3078EYRZ can connect a controller board to distributed sensors, remote I/O modules, and condition-monitoring equipment over a balanced RS-485 bus. A 16 Mbps rate supports rapid polling and short cable runs, while differential signaling reduces susceptibility to common-mode industrial noise. The ±15 kV bus-pin ESD protection is useful around field-wired connectors, although additional coordinated surge protection may still be required for severe EFT or lightning environments. The true fail-safe receiver helps establish predictable logic states on an idle or faulted bus. Designers should confirm cable length, node spacing, termination strategy, and ground potential in the final system because maximum signaling rate alone does not determine the usable communication distance.
推薦
Test and Measurement Instrumentation
The ADM3078EYRZ is suitable for connecting laboratory and field test equipment to external measurement modules through RS-422 or RS-485. The 3.3 V supply suits modern mixed-signal test boards, and the 8-pin SOIC package simplifies routing where space is limited. Its 16 Mbps capability supports fast command and data transfer over short instrument links, while true fail-safe reception improves behavior when a remote module is disconnected. Because this is a non-isolated interface, an instrument chassis may require careful grounding or an external isolation strategy to prevent ground loops. Differential pair routing, short connections, shielding practices, and calibrated termination should be established during prototype testing.
推薦
Motion and Position Control
The ADM3078EYRZ can interface a motion controller with distributed drives, position sensors, or encoder subsystems using a balanced RS-485 network. Its 16 Mbps data rate reduces command latency on short machine-bus runs, while the half-duplex topology supports economical shared-pair wiring. ±15 kV ESD protection helps protect the interface from discharge events encountered during installation and servicing, and true fail-safe receiver behavior provides a defined state when a node stops driving. Direction-control timing must prevent overlap between transmitters, and the host should enforce deterministic polling if cyclic motion performance matters. Use a solid ground reference, branch stubs kept short, and termination selected according to the actual cable and node topology.
推薦
Building Access and Security Control
The ADM3078EYRZ can connect access-control panels, door controllers, and security equipment over a short RS-485 multidrop network. The 16 Mbps rate accommodates compact control systems without requiring a larger high-speed interface package, and balanced differential signaling helps reject noise found near motors, relays, and power-conversion equipment. The device's ±15 kV ESD protection is useful at external cable interfaces, though security installations may also require threat-specific surge and fault protection. The true fail-safe receiver supports deterministic interpretation of an inactive bus. Because the transceiver is non-isolated, installers must address ground differences and maintain a low-impedance return path between remotely installed nodes to prevent unreliable operation or damage.
推薦
Communication and Network Equipment
The ADM3078EYRZ is appropriate for compact communication modules that need a robust balanced-line interface to a backplane, remote interface unit, or service port. The 3.3 V operating supply and 8-pin SOIC footprint fit modern mixed-signal equipment, while the 16 Mbps rate supports high-throughput command and data traffic over short cable or PCB interconnects. ESD protection on the external bus pins improves survivability during installation, and true fail-safe inputs help maintain defined logic during inactive periods. For backplane use, engineers should examine common-mode range, connector requirements, bus topology, and return-path continuity. For longer field cables, use the manufacturer's guidance on cable type, termination, protection, and grounding rather than treating the data-rate rating as a distance guarantee.
推薦
推薦產品摘要
工程參考資料,適用於 ADM3078EYRZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM3078EARZ | ADM3077EARZ | SP3078EEN |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Lattice Semiconductor |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Maximum Data Rate | 16 Mbps | 16 Mbps | 16 Mbps | 16 Mbps |
| Nominal Supply Voltage | 3.3 V | 3 V | 3.3 V | 3 V |
| Supported Standards | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 |
主要差異化特點
- Extended-temperature ordering option (對比ADM3078EARZ)
- High-speed half-duplex operation in a compact package (對比SP3078EEN)
- True fail-safe and hot-swap control features (對比ADM3077EARZ)
設計說明
Route the differential pair as a controlled-impedance structure with uniform spacing and minimal vias. Keep transceiver and connector interfaces free of stubs, because a 16 Mbps signal can be sensitive to impedance discontinuities. Provide a continuous ground reference beneath or adjacent to the pair, avoid switching-power and high-current traces nearby, and test eye quality and common-mode behavior across temperature and cable conditions.
Place the local supply-decoupling network directly at the ADM3078EYRZ power pin and return it to the device ground through a short, low-impedance path. Keep the RS-485 bus pins away from the decoupling loop to prevent transient current from injecting into the data conductors. Confirm the exact capacitor values and operating limits against the Analog Devices data sheet and the power-source impedance before releasing the layout.
Do not assume that ±15 kV ESD protection eliminates the need for external surge protection or correct grounding. ESD, EFT, and lightning transients impose different energy and coupling requirements. Determine the cable length, connector type, ground potential, and required surge level for the installation, then coordinate termination, protective devices, and the transceiver's fail-safe behavior rather than treating the protection rating as complete system immunity.
For a half-duplex multidrop bus, allow only one transmitter to assert its driver-enable input at a time. Use defined host control logic and adequate dead time between direction changes to avoid contention. Check the DE and RE timing, receiver enable polarity, and propagation delay in the manufacturer data sheet, particularly when two nodes can initiate transmissions independently.
合規資訊
The manufacturer product page identifies the ADM3078E family and Data Sheet, Rev. F. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals statements were not identified in the cited product text, so these fields remain unknown.