ADM3311EARU - 3/5 3.3V RS-232 Transceiver | Analog Devices
MPN: ADM3311EARU ✓ 啟用中ADM3311EARU 概覽
An RS-232 transceiver is an interface-circuit category that converts logic-level signals between a host controller and a serial port. The transmission path uses differential voltage levels defined by EIA-232, while the receiver path translates those bipolar signals back into CMOS-compatible logic. Within the broader hierarchy, the ADM3311EARU belongs to the RS-232 interface transceiver class, then to line-driver and receiver ICs, and finally to the wider interface IC and semiconductor categories.
Three driver channels support three outbound data or control signals, while five receiver channels support five inbound signals. The integrated DC-DC converter generates the positive and negative voltage levels required for compliant RS-232 transmission from one low-voltage supply. According to the Analog Devices ADM3311E product documentation, the device is designed to meet the EIA-232 standard while operating across a 2.7 V to 3.6 V supply range.
The ADM3311EARU is identified as a full RS-232 transceiver with 15 kV ESD protection. Its green idle capability allows a connected system to control the interface state and reduce power use when the port is not active. Because the charge-pump circuitry is integrated, board designers can avoid a discrete negative rail and its associated filtering components, although the required charge-pump and bypass capacitors still need to be placed according to the manufacturer's recommended layout.
Typical applications include industrial serial consoles, data-acquisition equipment, point-of-sale terminals, embedded control panels, and service ports in instrumentation. The three-driver and five-receiver arrangement matches systems that need several control signals flowing in one direction and multiple status or data signals returning from a peripheral.
The primary design consideration is to preserve the RS-232 voltage-domain separation between the transceiver and low-voltage logic. Place the charge-pump capacitors and supply bypass capacitors close to their designated pins, route driver outputs away from sensitive receiver inputs, and provide the protection network recommended for the cable and enclosure environment.
This page combines the ADM3311E family architecture with package-specific sourcing information, application guidance, comparison parameters, and practical layout notes. It also identifies compatible candidates separately from true pin-for-pin replacements so engineers can evaluate each substitution against channel count, voltage levels, timing, and protection requirements.
直接替換替代品,適用於 ADM3311EARU — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
ADM3310EARU
✅ 直接替換聯絡詢價
查看資料表 →ADM3310EARUZ
✅ 直接替換📋 參考替代品(不在目錄中)
ADM3311EARU 規格
| Product Type | RS-232 transceiver |
| Driver Channel Count | 3 channels |
| Receiver Channel Count | 5 channels |
| Supply Voltage Range | 2.7 V to 3.6 V |
| Power Supply Architecture | Single supply with on-chip DC-DC converter |
| Interface Standard | EIA-232 / RS-232 |
| ESD Protection | 15 kV |
| 封裝 | 28-pin TSSOP |
| 安裝類型 | Surface mount |
| Green Idle Feature | Supported |
| Driver Output Type | RS-232 differential output |
| Receiver Input Type | RS-232 differential input |
| Logic Supply Compatibility | 2.7 V to 3.6 V CMOS-compatible operation |
| RoHS 狀態 | unknown |
| REACH Status | unknown |
ADM3311EARU 28-pin tssop 腳位配置指南
ADM3311EARU(28-pin tssop 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ADM3311EARU.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADM3311EARU 適用於 6 應用s: Industrial Serial Control Console, Data-Acquisition and Test Equipment, Point-of-Sale Terminal Interface, Embedded Instrument Service Port, Network Appliance Maintenance Interface, Medical and Laboratory Instrument Interface.
Industrial Serial Control Console
The ADM3311EARU fits an industrial control console that must translate a 3.3 V controller bus into an RS-232 port. Its 3 driver channels can carry command, reset, and service-control signals, while 5 receiver channels accept status or acknowledgment inputs. The integrated DC-DC converter removes the need for a separate negative supply rail, and the 15 kV ESD protection rating is valuable in panels exposed to cable transients. Add the external protection network recommended by Analog Devices for the connected cable and enclosure.
推薦
Data-Acquisition and Test Equipment
Data-acquisition equipment often combines a low-voltage control processor with a legacy RS-232 instrument. The ADM3311EARU provides the voltage-domain conversion in one 28-pin TSSOP device, with 3 outbound drivers and 5 inbound receivers for commands and measurement-status signals. Because the part operates from 2.7 V to 3.6 V, it can be paired directly with 3.3 V control logic. Place the charge-pump capacitors near the device and keep RS-232 traces separated from sensitive analog and reference nodes.
推薦
Point-of-Sale Terminal Interface
A point-of-sale terminal can use the ADM3311EARU to connect a 3.3 V embedded controller to an RS-232 peripheral such as a printer, scanner, or customer display. Three drivers cover outbound service and transaction-control signals, while five receivers accommodate acknowledgments and peripheral status. The single-supply operation simplifies the power tree, and the integrated charge-pump avoids external negative-rail generation. Confirm grounding and add the manufacturer's recommended surge and ESD protection for cables that leave the enclosure.
推薦
Embedded Instrument Service Port
The ADM3311EARU is suitable for a service port on embedded instrumentation where a 3.3 V processor must communicate with external service equipment. Its 3 drivers and 5 receivers support a mixture of transmit commands and receive status lines, while the integrated DC-DC converter supplies the required RS-232 levels from a single rail. The 15 kV ESD rating supports robust cable-connected equipment when combined with correct board layout and external protection. Keep the service connector ground reference close to the interface return path.
推薦
Network Appliance Maintenance Interface
A network appliance can use the ADM3311EARU for a low-speed RS-232 maintenance or bootstrap connection alongside Ethernet interfaces. The 3.3 V-compatible device avoids the complexity of a dual-supply RS-232 implementation, while 3 transmit channels and 5 receive channels cover common console and control signals. The 28-pin TSSOP package allows a compact layout, and the integrated DC-DC converter reduces the number of external power-path components. Apply the ESD and surge network appropriate for an exposed service connector.
推薦
Medical and Laboratory Instrument Interface
The ADM3311EARU can serve as the RS-232 interface between a laboratory controller and an instrument that retains a legacy serial port. The 3-driver, 5-receiver arrangement supports command transmission and multiple status inputs, while single-supply operation simplifies low-voltage medical-control electronics. The 15 kV ESD protection characteristic helps protect the interface when users attach external cables. Isolation, creepage, and patient-safety requirements must be evaluated separately when the serial port crosses a patient-connected isolation barrier.
推薦
推薦產品摘要
工程參考資料,適用於 ADM3311EARU — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM3310EARU | ADM3310EARUZ |
|---|---|---|---|
| Package | 28-pin TSSOP | 28-pin TSSOP | 28-pin TSSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Full RS-232 transceiver | RS-232 transceiver | RS-232 transceiver |
| Supply Voltage Range | 2.7 V to 3.6 V | 2.7 V to 3.6 V | 2.7 V to 3.6 V |
| Driver Channel Count | 3 channels | Different from ADM3311EARU | Different from ADM3311EARU |
| Receiver Channel Count | 5 channels | Different from ADM3311EARU | Different from ADM3311EARU |
| DC-DC Converter | Integrated | Integrated single-supply conversion | Integrated single-supply conversion |
| External Capacitor Configuration | ADM3311E charge-pump configuration | Different configuration | Different configuration |
| Interface Standard | EIA-232 / RS-232 | RS-232 | RS-232 |
主要差異化特點
- Higher channel count than the identified same-footprint ADM3310 candidates (對比ADM3310EARU)
- Single-supply RS-232 operation without an external negative rail (對比ADM3310EARU)
- Documented high-level ESD protection for cable-connected interfaces (對比ADM3310EARU)
設計說明
Place the charge-pump and bypass capacitors directly beside the pins identified in the ADM3311E datasheet, and keep their ground returns short and continuous. The integrated DC-DC converter still requires a correctly sized external capacitor network, so omitting the recommended parts or extending their traces can impair charge-pump performance. Use the manufacturer pin-description and layout examples when assigning PCB tracks.
Keep the three RS-232 driver outputs away from the five receiver inputs and from sensitive analog or reference nodes. Maintain the recommended spacing between opposing voltage domains, connect cable shields with the chassis or protection strategy defined by the product, and route the interface return conductor to reduce common-mode pickup. This is particularly important when the host processor or analog converter has high-impedance inputs.
Do not treat any 28-pin TSSOP RS-232 transceiver as automatically interchangeable with the ADM3311EARU. The ADM3310EARU and ADM3310EARUZ share the footprint but differ in channel count and external capacitor configuration. Before substitution, compare every connected pin, verify that the required number of drivers and receivers is available, and confirm idle or enable behavior. Also avoid treating the 15 kV ESD rating as a substitute for external surge protection.
合規資訊
The Analog Devices product documentation identifies the device as a 15 kV ESD-protected RS-232 transceiver, but no specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for this ordering code.