ADS1248IPWR - 24-Bit 2-kSPS Precision ADC | Texas Instruments (Tape & Reel)
MPN: ADS1248IPWR ✓ 啟用中ADS1248IPWR 概覽
An analog-to-digital converter, or ADC, converts continuous analog voltage into a numeric value for processing by a microcontroller or other digital system. The ADS1248 belongs to the ADC and data-converter hierarchy within integrated circuits. Its delta-sigma architecture, programmable gain amplifier, and single-cycle settling digital filter combine accurate conversion with integrated functions that reduce the component count required for precision measurement systems.
The headline specifications are 24-bit resolution, 2-kSPS conversion throughput, and eight-channel multiplexed input capability. The device includes a low-noise programmable-gain amplifier, an internal oscillator, a built-in temperature sensor, multiplexers, automatic calibration, and support for bipolar power supplies. These features make it suitable for temperature, pressure, strain, load-cell, and other bridge-based sensor systems where low noise and flexible gain are important.
Its sigma-delta modulation and digital filtering support precise measurement of slowly changing or low-bandwidth signals. The programmable PGA can amplify small sensor outputs before conversion, while the eight-channel multiplexer allows several inputs to share one converter. The single-cycle settling digital filter is intended to support deterministic conversion timing after configuration changes. Because this is a low-speed precision ADC, throughput and conversion latency must be balanced against the selected data rate and filtering configuration.
Typical applications include precision temperature measurement, industrial pressure and force sensing, strain-gauge and load-cell instrumentation, portable instrumentation, and low-noise process monitoring. The integrated temperature sensor supports local system-temperature measurement, while programmable gain helps match the ADC input range to low-level sensor outputs. Multiple input channels also reduce the need for separate converter packages in multi-sensor equipment.
PCB implementation should preserve clean analog grounding, short sensor traces, and properly decoupled supply connections. Differential sensor inputs should be routed symmetrically to minimize conversion error from unequal traces and parasitic capacitance. Designers should also verify the required input range, gain setting, data rate, reference voltage, and digital interface timing before committing the TSSOP layout.
This page combines manufacturer device information, structured technical specifications, drop-in family comparisons, application guidance, and design notes to support faster component selection and PCB implementation. It also distinguishes verified device attributes from parameters that require confirmation from the latest manufacturer documentation.
直接替換替代品,適用於 ADS1248IPWR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADS1248IPWR (相同外形與佔位) — 差異在於 Internal Oscillator, Operating Temperature Range, Package, Programmable Gain Amplifier, Digital Filter.
ADS1247IPW
✅ 直接替換聯絡詢價
查看資料表 →ADS1246IPW
✅ 直接替換聯絡詢價
查看資料表 →ADS1248IPWR 最大額定值與電氣特性
| ADC Resolution | 24 bit |
| Conversion Throughput | 2 kSPS |
| Number of Channels | 8 channels |
| Differential Input Channels | 4 channels |
| Single-Ended Input Channels | 7 channels |
| ADC Architecture | Delta-sigma ADC |
| Programmable Gain Amplifier | Integrated low-noise PGA |
| Digital Filter | Single-cycle settling digital filter |
| Internal Oscillator | Integrated |
| Built-In Temperature Sensor | Integrated |
| Supply Configuration | Bipolar power supply |
| Automatic Calibration | Supported |
| 工作溫度範圍 | -40°C to +125°C |
| 封裝 | 28-pin TSSOP (PW) |
| 安裝類型 | Surface mount |
ADS1248IPWR 28-pin tssop (pw) 腳位配置指南
ADS1248IPWR(28-pin tssop (pw) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS1248IPWR.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS1248IPWR 適用於 6 應用s: Precision Temperature Measurement, Load Cell and Force Measurement, Strain Gauge Instrumentation, Industrial Pressure Monitoring, Portable Instrument and Sensor Hub, Process and Environmental Monitoring.
Precision Temperature Measurement
ADS1248IPWR fits temperature-signal conditioning where low-level sensor outputs must be digitized with high resolution rather than high throughput. The 24-bit conversion format and integrated programmable-gain amplifier can amplify small voltage changes before the 2-kSPS delta-sigma ADC performs conversion. Its eight multiplexed channels also allow several temperature sensors to share one converter. The built-in temperature sensor provides a useful local monitoring function, while the selectable single-ended or differential input configuration supports grounded thermistors and bridge-style probes.
推薦
Load Cell and Force Measurement
ADS1248IPWR is suitable for load-cell and force-sensor front ends that generate small differential signals across a Wheatstone bridge. Four differential inputs permit multiple bridge channels to be measured sequentially, while the integrated low-noise programmable-gain amplifier raises the signal before digitization. The 24-bit, 2-kSPS converter prioritizes resolution and stable measurements rather than waveform capture. Designers should select a gain that prevents bridge excitation or input imbalance from overloading the analog front end, then preserve symmetry between each differential pair.
推薦
Strain Gauge Instrumentation
ADS1248IPWR supports strain-gauge instrumentation by combining four differential inputs with programmable gain and 24-bit conversion resolution. A strain bridge typically produces a small differential voltage proportional to mechanical stress, making input symmetry, low noise, and gain calibration central to measurement accuracy. The multiplexer allows several bridges or auxiliary channels to share one converter. At 2 kSPS, the converter suits static or slowly varying structural measurements rather than high-bandwidth vibration analysis.
推薦
Industrial Pressure Monitoring
ADS1248IPWR can digitize multiple low-level pressure-sensor outputs in industrial monitoring equipment. Four differential inputs support bridge-based pressure cells, and the programmable-gain amplifier reduces the number of external analog amplification stages. The 24-bit conversion format preserves fine resolution across the sensor range, while the seven single-ended option can serve compatible unipolar sensors or auxiliary voltages. Because pressure systems may include noisy motors or switching supplies, analog filtering, grounding, and reference routing require careful PCB planning.
推薦
Portable Instrument and Sensor Hub
ADS1248IPWR is appropriate for compact instrumentation that gathers several precision sensor readings within a limited package area. Eight multiplexed channels reduce the number of separate converters, and the 28-pin TSSOP supports conventional surface-mount assembly. The 2-kSPS rate is well matched to temperature, pressure, and environmental sensors that change slowly. A portable design should still budget for the converter's supply requirements, reference implementation, and digital interface requirements while maintaining separation between sensitive analog traces and switching-converter paths.
推薦
Process and Environmental Monitoring
ADS1248IPWR supports process monitoring systems that combine several slow analog measurements with high-resolution conversion. The eight-channel architecture can monitor temperature, pressure, level, or slow process variables while the programmable-gain amplifier accommodates different signal amplitudes. A 2-kSPS conversion rate is suitable for supervisory and logging functions, not fast feedback loops. Engineers should select data rates and digital filtering for the required response time, then verify channel-switching behavior and settling time when measurements have widely different impedance levels.
推薦
推薦產品摘要
工程參考資料,適用於 ADS1248IPWR — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADS1247IPW | ADS1246IPW |
|---|---|---|---|
| Package | 28-pin TSSOP (PW) | 28-pin TSSOP (PW) | 28-pin TSSOP (PW) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| ADC Resolution | 24 bit | 24 bit | 24 bit |
| Conversion Throughput | 2 kSPS | 2 kSPS | 2 kSPS |
| Multiplexed Input Channels | 8 channels | 6 channels | 4 channels |
| ADC Architecture | Delta-sigma | Delta-sigma | Delta-sigma |
| Programmable Gain Amplifier | Integrated low-noise PGA | Integrated low-noise PGA | Integrated low-noise PGA |
| Digital Filter | Single-cycle settling digital filter | Single-cycle settling digital filter | Single-cycle settling digital filter |
主要差異化特點
- Highest multiplexed channel count in the documented ADS124x comparison (對比ADS1247IPW)
- Twice the differential-measurement capacity of the lower-channel family member (對比ADS1246IPW)
- Combines eight-channel multiplexing with a 24-bit conversion format (對比ADS1220IPW)
設計說明
Route differential sensor inputs as symmetric pairs from the connector or bridge to the ADC, with no stubs or unmatched branches where practical. Keep input and reference traces short, place their specified bypass capacitors close to the associated pins, and avoid running analog inputs beneath digital clocks or high-current switching paths. This layout discipline is especially important because the integrated PGA amplifies both the intended differential signal and any noise or offset introduced by trace mismatch.
Plan the analog reference as a low-noise source and follow the manufacturer data sheet for reference input and bypass-capacitor requirements. Do not share noisy reference returns with sensor returns, and keep the reference route physically close to the converter where practical. Reference instability can dominate the accuracy of the 24-bit conversion even when the sensor itself and the PGA are operating correctly.
Do not select the conversion rate or PGA gain solely from nominal sensor sensitivity. First calculate the full analog input range, including bridge excitation variation, sensor tolerance, common-mode voltage, and overdrive limits. Then select a gain and data rate that preserve range and settling margin. ADS1248IPWR supports four differential or seven single-ended inputs, so channel multiplexing and the signal impedance of each selected sensor also require verification.
Provide the required bipolar supply rails and decouple each supply connection according to the manufacturer reference circuit. Separate or minimize the return path between analog and digital currents to prevent converter activity from producing supply ripple across sensitive input or reference nodes. Verify startup sequencing when the ADC, sensor excitation, and digital controller do not share identical supply timing.
合規資訊