ADS7817UC - 12-Bit, 200kHz Differential SAR ADC | Texas Instruments
MPN: ADS7817UC ✓ 啟用中ADS7817UC 概覽
An ADC is an analog-to-digital converter, a semiconductor device that converts a continuously varying analog voltage into a numeric value for processing, measurement, or control. The ADS7817 belongs to the 12-bit SAR ADC family, where successive-approximation conversion repeatedly compares the sampled input with a reference voltage. The Texas Instruments ADS7817 family is designed for systems that require modest conversion resolution, differential analog input handling, and a compact interface.
The converter provides 12-bit resolution and a maximum sampling rate of 200kHz. Its fully differential input accepts two complementary signal nodes, which is useful when the source has a differential output or when common-mode rejection is important. The reference range of 100mV to 2.5V allows the analog signal span to scale with the available precision reference. At the limits of that range, the corresponding input-referred resolutions are 49uV and 1.22mV.
Low-power operation is a core feature of the ADS7817 family. Automatic power-down reduces consumption when conversion activity is not required, while the small 8-SOIC package simplifies compact analog and mixed-signal layouts. The ADS7817UC ordering code is associated with the 8-SOIC package, and the manufacturer product page lists the family in plastic mini-DIP-8, SO-8, and MSOP-8 options for design flexibility across package inventories.
Typical uses include battery-powered instrumentation, industrial sensor interfaces, process-control measurement, low-level differential signal acquisition, and portable equipment requiring a compact converter. In a sensor circuit, the differential input can accept the sensor output when the source supports differential signaling. In a laboratory instrument, the adjustable reference lets the designer trade full-scale range against input-referred resolution while preserving the 12-bit output format.
Design the input and reference networks to preserve the converter’s high-impedance differential input characteristics. Keep analog traces short, place bypass capacitors close to the supply and reference pins, and return unused analog and digital grounds carefully according to the manufacturer datasheet. Because input-referred resolution changes with the reference voltage, verify the signal span, common-mode range, and headroom together rather than treating the 12-bit resolution as a fixed voltage increment.
This product guide combines the manufacturer specifications with package details, application guidance, design notes, and a verified drop-in assessment. It also distinguishes confirmed device characteristics from parameters that require confirmation from the datasheet, helping engineers plan the analog front end, footprint, conversion rate, and procurement requirements with greater precision.
直接替換替代品,適用於 ADS7817UC — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADS7817UC (相同外形與佔位) — 差異在於 Package, Resolution, Analog Input Type, Architecture, Digital Interface.
ADS7816UB/2K5G4
✅ 直接替換聯絡詢價
查看資料表 →ADS7822U
✅ 直接替換聯絡詢價
查看資料表 →ADS7826
✅ 直接替換📋 參考替代品(不在目錄中)
ADS7827
✅ 直接替換📋 參考替代品(不在目錄中)
ADS7829
✅ 直接替換📋 參考替代品(不在目錄中)
ADS7817UC 最大額定值與電氣特性
| 解析度 | 12 bit |
| 取樣率 | 200kHz |
| Conversion Architecture | 1 SAR conversion |
| Analog Input Count | 1 input |
| Analog Input Type | Fully differential |
| Input Impedance | High impedance |
| Reference Voltage Range | 100mV to 2.5V |
| Input-Referred Resolution | 49uV to 1.22mV |
| Power-Down Function | Automatic power down |
| 封裝 | 8-SOIC |
| 安裝類型 | Surface mount |
| Family Package Options | Plastic mini-DIP-8, SO-8, and MSOP-8 |
| Output Interface | Serial port |
| ADC Type | 12-bit micro-power sampling ADC |
ADS7817UC plastic mini-dip-8, so-8, and msop-8 腳位配置指南
ADS7817UC(plastic mini-dip-8, so-8, and msop-8 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS7817UC.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS7817UC 適用於 6 應用s: Differential Sensor Measurement, Battery-Powered Portable Instrument, Industrial Process Monitoring, Laboratory Measurement Equipment, Precision Control Feedback, Low-Level Signal Acquisition.
Differential Sensor Measurement
The ADS7817UC suits low-level differential sensor signals because it combines a fully differential input with 12-bit resolution and a 200kHz sampling rate. The differential input can reduce sensitivity to common-mode disturbance when the sensor and analog front end support balanced signaling. Selecting a reference from 100mV to 2.5V lets the designer match the converter’s input-referred resolution, which ranges from 49uV to 1.22mV, to the expected measurement span. Confirm the source impedance, input common-mode range, and acquisition timing in the manufacturer data sheet before finalizing the sensor interface.
推薦
Battery-Powered Portable Instrument
The ADS7817UC is appropriate for portable measurement equipment where both conversion performance and board area matter. Its 200kHz sampling rate supports timely acquisition, while automatic power-down can reduce activity when measurements are not continuously required. The 8-SOIC package provides a compact surface-mount option, and the adjustable 100mV to 2.5V reference supports different sensor spans. Power budgeting should compare active and power-down current using the manufacturer data sheet, while the analog and digital sections should be partitioned to control ground currents.
推薦
Industrial Process Monitoring
The ADS7817UC can serve industrial process-monitoring circuits that require a compact differential ADC rather than a high-channel-count converter. A 200kHz sampling rate and 12-bit resolution provide useful measurement bandwidth for many pressure, temperature, and position sensing systems. The fully differential input can simplify rejection of common-mode noise when paired with a compatible sensor front end. Choose the reference from 100mV to 2.5V to establish the required full-scale span, and verify industrial temperature, supply, and accuracy requirements against the official electrical tables.
推薦
Laboratory Measurement Equipment
The ADS7817UC is useful in laboratory instruments that acquire small differential voltages while requiring compact PCB area. Its 12-bit conversion resolution is complemented by a selectable reference range of 100mV to 2.5V, allowing the full-scale range to match the test signal. At the documented reference limits, input-referred resolution is 49uV or 1.22mV. The 200kHz sampling rate supports more responsive acquisition than a slow display-oriented measurement path. Layout must preserve the high-impedance input behavior, minimize parasitic capacitance, and provide local supply bypassing.
推薦
Precision Control Feedback
The ADS7817UC can provide feedback quantization for precision control loops where 12-bit resolution and differential input capability match the sensor or command signal. Its 200kHz sampling rate gives designers a defined conversion cadence, while the 100mV to 2.5V reference range permits direct scaling of smaller signals. The resulting input-referred resolution ranges from 49uV to 1.22mV, allowing resolution to be balanced against usable span. The control system must account for acquisition time, serial latency, and any filtering between conversion and actuation.
推薦
Low-Level Signal Acquisition
The ADS7817UC is appropriate for low-level signal acquisition where a small differential voltage must be digitized without occupying substantial board area. Its high-impedance fully differential input can accommodate suitable sensor and conditioning networks, while the adjustable 100mV to 2.5V reference allows the converter to cover a compact signal range. The 12-bit resolution corresponds to input-referred resolutions between 49uV and 1.22mV. Careful reference selection, low-noise grounding, short analog routing, and suitable source impedances are essential for reaching the intended measurement performance.
推薦
推薦產品摘要
工程參考資料,適用於 ADS7817UC — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Manufacturer | Texas Instruments |
| Package | 8-SOIC |
| Resolution | 12 bit |
| Sampling Rate | 200kHz |
| Conversion Architecture | 1 SAR conversion |
| Analog Input | 1 fully differential input |
| Input Impedance | High impedance |
| Reference Voltage Range | 100mV to 2.5V |
| Input-Referred Resolution | 49uV to 1.22mV |
| Power-Down Function | Automatic power down |
| Output Interface | Serial port |
主要差異化特點
- Differential input in a compact converter (對比Single-ended 12-bit ADC options)
- Adjustable reference supports two resolution regimes (對比Fixed-reference converters)
- Power management for compact instrumentation (對比Continuously powered converter options)
設計說明
Place input, reference, and supply bypass components directly beside their associated device pins. Route the fully differential input as a short, balanced pair and keep switching-current paths away from the high-impedance analog nodes. The input-referred resolution can be as fine as 49uV, so long traces, probe capacitance, and leakage from adjacent circuitry can materially affect the useful measurement noise. Use the manufacturer pin-description table to identify analog and digital returns before finalizing the ground topology.
Design the supply and reference network around the operating mode rather than only the nominal conversion rate. Automatic power-down can reduce demand during inactive intervals, while the 200kHz sampling capability defines the active conversion workload. Verify active current, power-down current, supply tolerances, and reference settling time in the official data sheet. Decouple the reference locally and account for reference-current changes so switching noise is not injected into the differential measurement path.
Do not interpret the 12-bit resolution as a fixed voltage step independent of the reference. The usable step changes as the reference moves from 100mV to 2.5V, with corresponding input-referred resolutions of 49uV to 1.22mV. Also check that the sensor output remains inside both the differential input range and the allowed common-mode range. Confirm acquisition timing and source impedance because a high-impedance input does not remove the requirements imposed by the sampling network.
合規資訊
Compliance status is not stated in the manufacturer and distributor information reviewed. Confirm RoHS, REACH, automotive qualification, lead-free, halogen-free, and conflict-mineral declarations for the exact ordering code before production release.