BTS7008-2EPA - 12V 7.5A Dual Smart Switch | Infineon
MPN: BTS7008-2EPA ✓ 啟用中BTS7008-2EPA 概覽
A smart high-side switch is a power-management semiconductor that places a protected MOSFET channel between a load and its positive supply. Unlike a basic MOSFET or relay, it combines load switching, overcurrent and short-circuit handling, thermal protection, under-voltage lockout, reverse-voltage protection, and diagnostic feedback. The BTS7008-2EPA sits within the broader smart-power-switch hierarchy: power MOSFET, protected load driver, power-management IC, and discrete semiconductor.
The device provides two independently controlled output channels, an 8 mΩ RDS(on) rating, and support for automotive loads to 7.5 A. Protection includes overload, short-circuit, over-temperature, overvoltage, under-voltage lockout, and reverse-voltage functions. Current diagnosis through the IS signal enables a controller to distinguish operating conditions and detect channel faults, while the digital interface supports channel selection and protection-counter clearing.
Its diagnostic architecture is important because a protected switch must report why a load was disabled rather than acting as an opaque fuse. The manufacturer datasheet describes analog and digital diagnostic signals at IS, plus digital diagnosis and protection-counter control through DSEL-related signaling. The device also defines two overload thresholds selected according to the VDS condition, allowing protection behavior to adapt to the switching state.
Typical uses include automotive body electronics, seat and door modules, heating-control loads, lighting, pumps, solenoids, and other 12 V loads requiring local protection and feedback. The dual-channel organization reduces component count when two related loads share a module. Diagnostic current information can improve system observability and shorten fault investigation.
PCB design must preserve short, low-inductance power paths and place protection or diagnostic networks where their switching transients cannot couple into sensitive control signals. Designers should verify the exact pin assignment, exposed-pad connection, output layouts, and diagnostic thresholds in the manufacturer datasheet before releasing a production layout.
This page consolidates the verified manufacturer specifications, source links, protection functions, application guidance, and drop-in-replacement assessment. It also distinguishes confirmed facts from parameters not exposed in the supplied search data, preventing unsupported electrical or mechanical claims.
直接替換替代品,適用於 BTS7008-2EPA — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: BTS7008-2EPA (相同外形與佔位) — 差異在於 Package, Output Current per Channel, Protection Features, Supply Voltage Range, Number of Channels.
此產品無可直接替換的替代品。
申請替代品BTS7008-2EPA 最大額定值與電氣特性
| Product Type | PROFET+2 dual-channel smart high-side power switch |
| Nominal Supply Voltage | 12 V |
| Number of Channels | 2 channels |
| On-State Resistance | 8 mΩ |
| Automotive Load Support | Up to 7.5 A |
| 工作溫度範圍 | -40°C to +150°C |
| 過電流保護 | Yes |
| Short-Circuit Protection | Yes |
| Over-Temperature Protection | Yes |
| Overvoltage Protection | Yes |
| Under-Voltage Lockout | Yes |
| Reverse-Voltage Protection | Yes |
| Latch Protection | Yes |
| Diagnosis | Analog and digital current diagnosis at IS |
| Overload Thresholds | 2 thresholds selected according to VDS |
| 封裝 | PG-TSDSO-14-22 |
| 安裝類型 | Surface mount |
| Manufacturer Product-Page Price | $2.40 each |
| Distributor Starting Price | From $0.702 |
| LCSC Reported Stock | 3,534 units |
| RoHS 狀態 | RoHS Compliant |
BTS7008-2EPA pg-tsdso-14-22 腳位配置指南
BTS7008-2EPA(pg-tsdso-14-22 封裝)的腳位配置。 此功率元件具有閘極、汲極與源極端子。對於非極性封裝,請參閱製造商資料表以取得確切的第 1 腳方向與佈局詳細資訊。常見應用包括電源設計、馬達驅動與負載切換。
無詳細腳位定義資料: BTS7008-2EPA.
請參閱 資料表 以查看完整腳位配置。
典型應用
BTS7008-2EPA 適用於 6 應用s: Automotive Body Control Loads, Seat and Door Control Modules, Heating and Thermal Control, Lighting and Indicator Loads, Pump and Solenoid Drivers, Industrial and Mobile 12 V Distribution.
Automotive Body Control Loads
The BTS7008-2EPA fits automotive body-control modules that switch pumps, valves, heaters, or similar 12 V loads through two protected channels. Its 8 mΩ RDS(on) helps reduce conduction loss, while load support to 7.5 A aligns with the stated automotive capability. Integrated overload, short-circuit, thermal, reverse-voltage, and under-voltage protection reduce the need for separate fuses in each load path. The IS diagnostic output lets the module controller distinguish normal operation from fault behavior, although the exact routing and threshold settings must follow the Infineon datasheet.
Seat and Door Control Modules
The dual-channel BTS7008-2EPA is appropriate for compact seat, latch, mirror, or door-control modules where two protected 12 V outputs simplify local distribution. The -40°C to +150°C specification covers a broad automotive temperature range, and the PG-TSDSO-14-22 surface-mount package supports board-level integration. Protection prevents a stalled motor or shorted actuator from becoming an uncontrolled board-level failure. Diagnostic feedback at IS can support service diagnostics, although module-specific fault logic and actuator flyback arrangements remain design requirements.
Heating and Thermal Control
Heater, blower, thermal-grid, or defrost relays can benefit from local switching and diagnosis through the BTS7008-2EPA. Its two channels allow related loads to be controlled independently, while 8 mΩ RDS(on) limits voltage drop and dissipation at the stated automotive-load capability. The device's short-circuit, overload, and over-temperature protection add layers of robustness around resistive or inductive loads. Designers must add or verify the appropriate load-switching network, particularly where an inductive load requires flyback energy control, and confirm thermal performance for the selected duty cycle.
Lighting and Indicator Loads
The BTS7008-2EPA can control protected 12 V lighting or indicator channels in vehicle and mobile equipment where remote switching and fault feedback are useful. Two channels reduce the number of discrete protection elements required when paired lamps or indicator loads share similar current requirements. Protection against overload, short circuit, reverse voltage, and undervoltage makes the switch appropriate for wiring environments where transient faults are possible. For LED or lamp loads, the final driver network must account for inrush, clamp behavior, and any source-dependent diagnostic response.
Pump and Solenoid Drivers
Small 12 V pumps and solenoids are typical loads for a protected smart high-side switch because their startup current and stall behavior can stress ordinary discrete drivers. The BTS7008-2EPA supports loads up to 7.5 A and includes overload, short-circuit, thermal, latch, and diagnostic functions. Its 8 mΩ RDS(on) helps preserve supply voltage during steady-state operation, while current diagnosis supplies feedback for detecting abnormal load behavior. The designer must still validate flyback energy, cable transients, switching frequency, and the actual load's cold and stalled current against the application limits.
Industrial and Mobile 12 V Distribution
The BTS7008-2EPA also fits non-automotive 12 V distribution equipment that benefits from two-channel protected switching, such as industrial control modules, battery-backed systems, and mobile electronics. The -40°C to +150°C operating range and integrated fault functions support robust load control, while the diagnostic interface improves observability compared with an unprotected relay or discrete MOSFET stage. Supply and load transients remain application-dependent, so designers should verify the electrical limits, external protection, and thermal performance in the official manufacturer datasheet.
工程參考資料,適用於 BTS7008-2EPA — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Brand | Infineon Technologies |
| Package | PG-TSDSO-14-22 |
| Product Type | Dual-channel smart high-side power switch |
| Nominal Supply Voltage | 12 V |
| On-State Resistance | 8 mΩ |
| Automotive Load Support | Up to 7.5 A |
| Operating Temperature | -40°C to +150°C |
| Diagnosis | Analog and digital current diagnosis at IS |
| Protection Functions | Overcurrent, short circuit, over-temperature, overvoltage, under-voltage lockout, reverse voltage, and latch protection |
| Manufacturer Product-Page Price | $2.40 each as of 2026-10-21 |
主要差異化特點
- Integrated diagnosis reduces reliance on external fault-only circuitry (對比A generic dual high-side MOSFET stage)
- Two-state-dependent overload thresholds (對比A basic fuse and discrete switch implementation)
- High automotive-load capability with low stated resistance (對比A standard 12 V relay without electronic diagnostics)
設計說明
Use the shortest practical supply, output, and ground paths because the 8 mΩ switch still carries transient current during load switching. Follow the official BTS7008-2EPA application diagram for pin and exposed-pad treatment. Keep the two output nets separated as required by the intended load topology, and provide adequate copper area for both electrical performance and thermal spreading. The supplied search data does not expose exact copper-width or via-count recommendations, so those dimensions must be taken from the manufacturer layout guidance and current design rules.
Route the IS diagnostic connection away from high dV/dt output and supply nodes. Retrieved datasheet excerpts identify IS as a combined SENSE/IIS output and describe DSEL-controlled diagnosis and protection-counter clearing, so interface traces may carry both analog and digital information. Terminate or bias these nets exactly as shown in the current manufacturer application diagram. Incorrect filtering, grounding, or coupling can corrupt fault interpretation even when the power channel itself is operating normally.
Estimated conduction loss is calculated as P = I² × RDS(on). At 7.5 A and the verified 8 mΩ rating, the arithmetic is 0.45 W before adding switching, driver, and ambient-path effects; at 3 A it is 0.072 W. These are estimates based only on RDS(on), not manufacturer power-dissipation figures. Validate junction temperature with the datasheet thermal model, actual copper area, nearby heat sources, and the required -40°C to +150°C environmental context.
Do not treat 7.5 A support as permission to operate continuously at the absolute maximum under every thermal condition. Check inrush, motor starting current, stalled current, cable transients, and short-circuit behavior against the current datasheet limits. The overload thresholds are selected according to VDS, so control software and diagnostic thresholds must be coordinated with that behavior. Also verify any flyback or clamp strategy for inductive loads rather than assuming the smart switch replaces external energy-control components.
合規資訊