CD40193BE - 4-Bit Presettable Up/Down Counter | Texas Instruments
MPN: CD40193BE ✓ 啟用中CD40193BE 概覽
A presettable counter is a sequential logic device that stores a multibit value and advances that value on command. The CD40193 belongs to the CMOS counter hierarchy, within binary counters, digital counters, logic ICs, and semiconductors. Unlike a basic ripple counter, it combines independent up and down clock inputs with preset and reset functions, allowing a circuit to start from an arbitrary initial state and then count in either direction.
Key functional characteristics include four synchronously clocked D-type flip-flops, one 4-bit output, a binary counting sequence, separate increment and decrement clocks, and 16-PDIP packaging. The dual-clock architecture permits a control system to select the counting direction without reversing every output bit. The parallel preset inputs support loading an initial count, while reset provides a defined starting condition. These features are useful when a design needs flexible sequencing rather than a fixed divide-by-N counter.
The dual-clock architecture is particularly useful in programmable sequencers, industrial control equipment, test systems, and embedded automation logic. The direction can be selected by routing events to the up or down clock, while the preset function can establish a new terminal count. A classic 4013-style flip-flop may be useful when separate set and reset functions are needed, but the CD40193 combines those operations into one dedicated counter IC and reduces the number of logic packages required for a four-bit sequencing function.
CD40193BE is also appropriate for laboratory timing circuits, digital function generators, batch counters, and educational digital-logic systems. Its 16-pin PDIP format is convenient for prototyping and through-hole assembly. The operating voltage, temperature range, clock-transition limits, and propagation-delay figures should be checked against the manufacturer datasheet before using the device where timing margins are critical or where the supply voltage differs from the nominal logic family requirement.
For reliable implementation, observe the maximum supply voltage and input transition-time limits, and provide adequate logic-level rise and fall times. Because this is a clocked sequential device, clock pulse width and recovery behavior determine whether multiple commands are recognized correctly. Decoupling close to the power pins, clean grounding, and short clock traces are especially important when the counter drives nearby digital control lines. Avoid long unprotected clock routes that can pick up switching noise and cause an unintended count operation.
This product page combines the manufacturer identification, verified distributor listings, pin-level implementation guidance, application examples, and drop-in replacement information. It is designed to help engineers confirm package compatibility, plan logic integration, and compare genuine alternatives without confusing a functionally similar counter with a pin-compatible replacement.
直接替換替代品,適用於 CD40193BE — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
CD40193BE4
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
CD40193BE
✅ 直接替換聯絡詢價
查看資料表 →CD40193BE 最大額定值與電氣特性
| Product Type | CMOS presettable binary up/down counter |
| Counter Elements | 1 element |
| Counter Width | 4 bit |
| Clock Type | Dual clock |
| Counting Direction | Up or down |
| Counting Sequence | Binary |
| Clock Edge | Positive edge |
| 輸出數量 | 4 outputs |
| 封裝 | 16-PDIP |
| Lead Count | 16 leads |
| 安裝類型 | Through-hole |
CD40193BE 腳位配置
| 腳位 1 | CLK UP — Positive-edge clock input for count-up operation |
| 腳位 2 | CLK DOWN — Positive-edge clock input for count-down operation |
| 腳位 3 | PE — Parallel preset enable input |
| 腳位 4 | P0 — Parallel preset data input for the least-significant counter bit |
| 腳位 5 | P1 — Parallel preset data input |
| 腳位 6 | P2 — Parallel preset data input |
| 腳位 7 | P3 — Parallel preset data input for the most-significant counter bit |
| 腳位 8 | MR — Master reset input |
| 腳位 9 | Q3 — Most-significant binary counter output |
| 腳位 10 | Q2 — Binary counter output |
| 腳位 11 | Q1 — Binary counter output |
| 腳位 12 | Q0 — Least-significant binary counter output |
| 腳位 13 | CARRY — Carry output for count-up operation |
| 腳位 14 | BORROW — Borrow output for count-down operation |
| 腳位 15 | VSS — Ground reference terminal |
| 腳位 16 | VDD — Positive supply terminal |
典型應用
CD40193BE 適用於 6 應用s: Programmable Industrial Sequencer, Digital Timing and Batch Counter, Bidirectional Step and Position Control, Test and Measurement Trigger Sequencing, Digital Logic Education and Prototyping, Embedded Automation and Control Logic.
Programmable Industrial Sequencer
The CD40193BE fits a programmable sequencing stage because its 4-bit parallel outputs can represent 16 sequence states while separate up and down clocks permit forward or reverse progression. An external controller can select the active clock and load a new starting value through the preset inputs, avoiding a separate bank of binary counter packages. The 16-PDIP package is also convenient for through-hole industrial control boards and legacy automation equipment. Before deployment, verify the supply-voltage range, clock pulse width, and timing margin under the machine's electrical environment. Use short command traces, local supply decoupling, and a defined reset sequence so that power restoration does not start an uncontrolled count.
推薦
Digital Timing and Batch Counter
The CD40193BE can implement a modulo-style batch counter because its four outputs represent the active count and its preset function establishes an initial or terminal value. A up-clock input accepts count events, while a reset or preset input controls operation between batches. This arrangement is useful in test fixtures, dispensing systems, event counters, and laboratory automation where a compact through-hole counter is preferred. The designer must establish the count direction, rollover behavior, and reset priority from the manufacturer truth table. Keep event inputs debounced or shaped when mechanical contacts are involved, and confirm that the clock pulse width and transition times satisfy the operating limits of the selected supply voltage.
推薦
Bidirectional Step and Position Control
The CD40193BE is appropriate for basic bidirectional position counting because independent up and down clocks map directly to positive and negative motion events. Its four parallel outputs provide a compact position state for comparison, indexing, or actuator control, while preset permits a known origin to be loaded after initialization. In motion-control equipment, account for bounce or contact noise, missed clock events, and simultaneous up/down commands before using the counter outputs directly. The logic should operate at a valid CMOS level, and all unused inputs must be tied to defined levels. Confirm that the required update rate, supply voltage, and temperature range meet the application.
推薦
Test and Measurement Trigger Sequencing
In test equipment, the CD40193BE can organize repeated stimulus steps by counting between preset states and exposing four binary control bits to the system under test. The dual-clock inputs allow a measurement sequence to move forward or back through test points without reversing the physical counter outputs. This is useful for automated bench controllers, fixture addressing, and educational instrumentation assembled on prototyping boards. Design the reset path to establish a repeatable entry state after power-up, and isolate clock sources from noisy analog sections to reduce false transitions. The final timing budget should include the counter's propagation delay plus external logic delays.
推薦
Digital Logic Education and Prototyping
The CD40193BE provides a clear teaching platform for binary counting, dual-clock direction control, parallel preset loading, and asynchronous reset behavior. Its four outputs expose the internal count directly on breadboard or through-hole test points, while the 16-PDIP package simplifies insertion into standard prototyping boards. Students can demonstrate 0-to-15 counting, down-count sequences, preset values, and carry or borrow events without assembling four separate flip-flop packages. Logic indicators should use appropriate drive levels and current limits, and unused inputs must not float. Because a clock input is sensitive to slow edges and noise, demonstrate clean pulse generation and reset behavior rather than relying on mechanical contacts directly.
推薦
Embedded Automation and Control Logic
The CD40193BE can provide auxiliary sequencing in embedded automation equipment that still uses discrete CMOS logic for legacy compatibility. A controller can load a preset count, issue advance or retreat commands, and read the resulting four-bit state for actuator coordination. The through-hole PDIP format suits older control boards with generous spacing and repair-oriented construction. Integrate the counter only after confirming that its supply range and logic thresholds match the surrounding 4000-series circuitry. Keep the reset path independent of ordinary count commands, provide local bypass capacitance, and route clocks away from switching power stages. This avoids introducing a new technology family into an otherwise mature control design.
推薦
推薦產品摘要
工程參考資料,適用於 CD40193BE — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | CD40193BE4 | CD40193BE | CD40193BE | CD40193BE |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Harris Corporation | Intersil | Renesas Electronics |
| Package | 16-PDIP | 16-PDIP | 16-PDIP | 16-PDIP | 16-PDIP |
| Counter Type | Presettable binary up/down counter | Presettable binary up/down counter | Presettable binary up/down counter | Presettable binary up/down counter | Presettable binary up/down counter |
| Counter Width | 4 bit | 4 bit | 4 bit | 4 bit | 4 bit |
| Clock Inputs | 2 dual-direction clocks | 2 dual-direction clocks | 2 dual-direction clocks | 2 dual-direction clocks | 2 dual-direction clocks |
| Clock Edge | Positive edge | Positive edge | Positive edge | Positive edge | Positive edge |
| Preset Function | Yes | Yes | Yes | Yes | Yes |
| Reset Function | Yes | Yes | Yes | Yes | Yes |
主要差異化特點
- Integrated bidirectional counting (對比SN74LS93DR)
- Parallel preset and reset control (對比CD40193BE4)
- Exact-package manufacturer sourcing options (對比CD40193BE)
設計說明
Do not allow either clock input to float or receive a slowly changing waveform. Both clocks are edge-sensitive, so noise or an indefinite transition near the active level can create an unintended count operation. Drive every unused input to a defined logic level, use clean push-pull clock sources where practical, and verify the transition-time and pulse-width limits in the manufacturer datasheet before increasing the operating frequency.
Place the supply bypass capacitor immediately between pins 16 and 15, with the ground return using the shortest practical path. Keep clock, preset, and reset traces away from inductive loads and switching-regulator power nodes. Because this is a through-hole counter used in sequential control, route output signals to nearby buffer or driver circuits rather than adding long capacitive loads directly to the counter outputs.
Confirm the allowed VDD range before connecting the counter to surrounding 4000-series logic. The exact supply and current limits are not established by the distributor listing and must be taken from the Texas Instruments or alternate-manufacturer datasheet. Do not exceed the maximum input voltage, and design the reset path so power-up cannot place unpredictable repeated pulses on either clock input.
Use a defined startup sequence in which reset is asserted before normal clocks are enabled. If an external controller can change direction during a count event, prevent simultaneous up and down edges by arbitration in external logic. Keep each clock source local to the counter where possible and buffer or isolate the trace if it must cross a noisy region of the PCB.
合規資訊
The product is a legacy CMOS logic IC; no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations were identified. AEC-Q100 is not applicable to this catalog logic device unless a separate automotive-qualified ordering option is introduced.