ICL7107CMH+T - 3.5-Digit ADC | Maxim Integrated
MPN: ICL7107CMH+T ✓ 啟用中ICL7107CMH+T 概覽
A dual-slope ADC is an integrating converter that measures an unknown input voltage by comparing integrated input and reference periods. This conversion method naturally rejects periodic interference, making it particularly useful in industrial environments where mains-related noise can affect low-level measurements. The ICL7107 also provides true differential input and reference behavior, supporting ratiometric measurements such as resistance and bridge-transducer sensing.
The converter is optimized for three-and-a-half-digit digital display instrumentation. Its seven-segment LED driver outputs reduce the external circuitry needed for a complete measurement front end. Maxim added a zero-integrator phase to the ICL7106 and ICL7107 families, helping eliminate residual integrator charge and improving repeated measurement accuracy.
The ICL7107 architecture combines an analog measurement section, digital control logic, and display-driver outputs in one package. Dual-slope conversion inherently favors noise rejection over very high sampling rates, making this device appropriate for panel meters, process monitoring, laboratory instruments, and handheld measurement equipment. Differential input capability also helps reject common-mode voltage when the measured signal is referenced to a moving or noisy ground.
Typical applications include digital panel meters, temperature controllers, weigh-scale indicators, bridge-signal instrumentation, laboratory measurement equipment, and industrial process monitoring. The device is especially suitable where a readable three-and-a-half-digit display and robust rejection of industrial interference matter more than high-speed waveform acquisition.
Designers should follow the manufacturer datasheet for the complete external-component and timing recommendations. Input and reference networks, display-decoding requirements, grounding, and PCB layout influence achievable accuracy. Because a converter can be electrically similar yet differ in package details, replacement planning should verify the exact 44-MQFP pin assignments rather than relying only on the displayed resolution.
This product page combines the confirmed converter characteristics, package identification, ordering options, and application guidance with engineering-focused replacement and comparison information. It is intended to help engineers distinguish true pin-compatible alternatives from parts that merely perform a similar measurement function or use a different package footprint.
直接替換替代品,適用於 ICL7107CMH+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7107CMH+T (相同外形與佔位) — 差異在於 Ratiometric Measurement Support.
此產品無可直接替換的替代品。
申請替代品ICL7107CMH+T 最大額定值與電氣特性
| Converter Type | 3.5-digit dual-slope ADC |
| Number of Channels | 1 channel |
| Input Architecture | True differential input |
| Reference Architecture | True differential reference |
| Conversion Method | Dual-slope integration |
| Zero-Integrator Phase | Supported |
| Display Resolution | 3.5 digits |
| Display Output | Seven-segment LED driver outputs |
| Ratiometric Measurement Support | Supported for ohms and bridge transducers |
| Package Type | 44-pin MQFP |
| Package Dimensions | 10 mm x 10 mm |
| 安裝類型 | Surface mount |
| Orderable Suffix | +T tape-and-reel configuration |
ICL7107CMH+T 10 mm x 10 mm 腳位配置指南
ICL7107CMH+T(10 mm x 10 mm 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7107CMH+T.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7107CMH+T 適用於 6 應用s: Industrial Digital Panel Meters, Temperature and Process Monitoring, Bridge-Transducer Instrumentation, Resistance Measurement Displays, Laboratory Measurement Instruments, Handheld Meter and Portable Test Gear.
Industrial Digital Panel Meters
The ICL7107CMH+T fits industrial digital panel meters because its dual-slope conversion process rejects periodic interference commonly found in industrial environments, while the true differential input and reference support robust signal conditioning. The integrated seven-segment LED driver outputs simplify the display interface, and the 3.5-digit format provides a direct numerical readout for process values. Place the converter according to the manufacturer layout guidance, keeping the analog input, reference, clock, and display paths appropriately separated. The result is a compact measurement front end suited to controller panels and monitoring equipment where readable results and interference rejection are more important than high-speed sampling.
推薦
Temperature and Process Monitoring
For temperature and process monitoring, the ICL7107CMH+T can digitize a conditioned analog measurement and present it through its seven-segment LED outputs without requiring a separate display-driver stage. True differential input and reference operation is valuable when the sensing chain develops offset or common-mode voltage relative to the measurement ground. The dual-slope method provides inherent rejection of periodic noise, making the device suitable for slowly changing industrial variables such as temperature, pressure, and level. Use the manufacturer datasheet to establish the sensor excitation, reference network, conversion interval, and input filtering required for the desired accuracy.
推薦
Bridge-Transducer Instrumentation
The ICL7107CMH+T is appropriate for bridge-based instrumentation because its true differential input and reference architecture supports ratiometric measurements from resistive bridges. Ratiometric operation helps compensate for supply or excitation variation when the bridge reference and measurement paths are arranged appropriately. The 3.5-digit resolution provides useful instrument-panel readability, and the dual-slope conversion process rejects common periodic interference. Implement the bridge excitation, input protection, reference components, and grounding according to the manufacturer guidance, then verify offsets and gain across the intended temperature and supply ranges.
推薦
Resistance Measurement Displays
The ICL7107CMH+T can serve as the measurement engine in a resistance meter or component tester that requires a stable three-and-a-half-digit display. Its true differential reference permits the measurement to be referenced to the excitation path, which supports ratiometric resistance measurement. Dual-slope conversion suppresses periodic interference, helping the instrument maintain repeatable readings around noisy power and grounding systems. The integrated LED driver outputs reduce the display-side component count. External resistors, protection networks, input filtering, and conversion timing should be selected from the manufacturer's recommended circuit for the target resistance range.
推薦
Laboratory Measurement Instruments
The ICL7107CMH+T is suitable for compact laboratory instruments that need a readable measurement rather than a high-speed waveform. Dual-slope conversion provides useful rejection of mains-related periodic noise, while true differential input and reference channels support measurement against a floating or noisy reference. A 3.5-digit readout and integrated seven-segment LED drivers simplify front-panel instrument construction. The 44-pin MQFP package supports compact board layouts, although accurate operation still depends on careful reference selection, clock layout, grounding, and separation of sensitive analog nodes from display-driver return currents.
推薦
Handheld Meter and Portable Test Gear
The ICL7107CMH+T fits handheld meters and portable test equipment when the instrument must tolerate noisy industrial environments and present measurements directly. Its dual-slope conversion process rejects common periodic interference, and the true differential measurement capability reduces sensitivity to common-mode voltage. The integrated seven-segment LED drivers allow a compact display implementation without a separate driver IC. Battery-powered designs should verify supply-current and operating-voltage limits from the manufacturer datasheet, while board layout should prevent display currents and switching transients from disturbing the input and reference nodes.
推薦
工程參考資料,適用於 ICL7107CMH+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Package | 44-pin MQFP (10 mm x 10 mm) |
| Brand | Maxim Integrated |
| ADC Resolution | 3.5 digits |
| Conversion Architecture | Dual-slope integrating ADC |
| Number of Channels | 1 channel |
| Input Configuration | True differential |
| Reference Configuration | True differential |
| Display Outputs | Seven-segment LED driver outputs |
| Zero-Integrator Phase | Supported |
| Ratiometric Measurement | Supported for ohms and bridge transducers |
主要差異化特點
- Integrated display-driver outputs (對比Generic discrete 3.5-digit ADC options)
- True differential measurement architecture (對比Single-ended measurement implementations)
- Dual-slope interference rejection (對比Successive-approximation ADC implementations)
- Zero-integrator phase (對比Earlier ICL7106 and ICL7107 implementations)
設計說明
Follow the manufacturer PCB layout for the differential input, reference, clock, and display-driver nets. Keep analog routing short and place the input and reference components close to their associated pins. Digital display-drive connections can carry switching currents, so route them separately from sensitive analog nodes and use an uninterrupted ground plane where the application permits.
Treat the reference as a precision measurement node rather than an ordinary supply rail. Use the component and filtering arrangement specified in the manufacturer application guidance, and verify that display-driver activity does not couple into the true differential input. The zero-integrator phase improves repeatability, but accurate results still depend on clean excitation, reference, and clock arrangements.
Do not select a replacement solely because its listing describes a 3.5-digit ADC. Verify all 44 package pins, display-output assignments, differential-input polarity, reference topology, conversion timing, and supply requirements. A package having 44 leads is necessary but not sufficient for a true drop-in replacement; use the manufacturer pin table and application circuit as the final compatibility check.
合規資訊
The available product information does not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 qualification is not applicable to this general-purpose measurement converter.