ICL7107CPL-3 - 3.5-Digit ADC with Display Driver | Analog Devices
MPN: ICL7107CPL-3 ✓ 啟用中ICL7107CPL-3 概覽
An integrating ADC is a voltage-to-digital conversion category that measures an input by integrating it over a defined interval and comparing the result with a reference. The ICL7107 family belongs to the broader ADC hierarchy of data converters, measurement ICs, and signal-chain semiconductors. Its dual-slope architecture is especially useful in industrial instruments because it rejects periodic interference and supports ratiometric measurements involving resistive or bridge transducers.
Key features include 3.5-digit measurement resolution, seven-segment decoding and display drive, a precision internal reference, an internal clock, true differential analog inputs, and parallel BCD output. According to the Analog Devices product page, the dual-slope conversion technique automatically rejects interference signals common in industrial environments. The integrated display driver eliminates the need for separate segment-driver circuitry in conventional three-digit LED panels.
The ICL7107CPL-3 combines the converter and display functions in one device, but its architecture is intended for relatively slow measurement updates rather than high-speed signal acquisition. The zero-integrator phase used by the ICL7106 and ICL7107 family improves system behavior, while the differential input and reference permit ratiometric measurement. The manufacturer lists the ICL7107 family as production, although order codes should be checked individually before committing a new design.
Typical applications include digital panel meters, temperature indicators, laboratory instruments, process-monitoring equipment, weigh systems, and resistance or bridge measurement circuits. Its integrated common-anode display drive is especially useful when the product must show a measurement without a separate microcontroller display interface. The 40-pin PDIP package also facilitates through-hole construction and straightforward bench-prototype assembly.
Designers should follow the manufacturer datasheet for external reference, oscillator, input-filter, and display-component selections. Display current limits, digit blanking, input common-mode range, and supply sequencing must be checked against the intended panel and measurement source. Because this is a through-hole integrating converter, PCB planning should account for the converter's long conversion interval and the electrical loading introduced by the display.
This page combines the manufacturer architecture description with practical comparison information for documented same-package alternatives. It also identifies the 40-pin PDIP footprint, useful application contexts, design checks, and practical distinctions that are not apparent from a distributor title alone.
直接替換替代品,適用於 ICL7107CPL-3 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7107CPL-3 (相同外形與佔位) — 差異在於 Mounting Type.
ICL7107CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7107CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7107CJL
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7107CPLZ
✅ 直接替換📋 參考替代品(不在目錄中)
TC7107CPL
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7107CPL-3 最大額定值與電氣特性
| ADC Resolution | 3.5 digits |
| Conversion Architecture | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits |
| Reference Type | Internal precision reference |
| Clock Source | Internal oscillator |
| Analog Input Configuration | True differential input |
| Reference Input Configuration | True differential reference |
| 輸出類型 | Parallel BCD word output |
| Integrated Display Driver | Seven-segment common-anode LED driver |
| Display Decoders | 7-segment decoders |
| Number of ADC Channels | 1 channel |
| Technology | CMOS |
| 封裝 | 40-pin PDIP |
| 安裝類型 | Through-hole, 0.600 in pitch |
ICL7107CPL-3 40-pin pdip 腳位配置指南
ICL7107CPL-3(40-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7107CPL-3.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7107CPL-3 適用於 6 應用s: Digital Panel Meter, Temperature Indicator, Industrial Process Monitor, Resistance Meter, Bridge Transducer Readout, Laboratory Digital Instrument.
Digital Panel Meter
The ICL7107CPL-3 is suited to a standalone three-digit display because it integrates a 3.5-digit ADC, seven-segment decoding, and common-anode LED drive in one 40-pin PDIP. Place the converter beside the LED panel and connect the measured analog input to its true differential input stage. The integrated decoder removes the usual separate driver IC, while the dual-slope conversion technique rejects periodic industrial interference. Confirm display current, digit polarity, and the required conversion interval in the manufacturer application guidance before laying out the board.
推薦
Temperature Indicator
A temperature indicator can use the ICL7107CPL-3 to convert a conditioned sensor voltage into a direct LED display reading. The true differential input supports source arrangements that reduce common-mode sensitivity, while the internal reference and clock simplify a dedicated instrument. The 3.5-digit resolution is appropriate for compact thermometers, incubators, and process readouts. Select input and reference networks so the full sensor range maps across the display, and use the zero-integrator behavior described by the manufacturer when planning repeated conversions.
推薦
Industrial Process Monitor
The dual-slope conversion technique in the ICL7107CPL-3 is useful for process-monitoring equipment exposed to periodic interference. The device combines measurement with direct LED display drive, allowing a compact controller front panel to show a process variable without a separate display driver. Its true differential input and reference arrangement also support ratiometric sensor measurements. Validate the signal range and conversion speed against the process response, then isolate sensitive analog routing from display-driver currents to avoid measurement disturbance.
推薦
Resistance Meter
The ICL7107CPL-3 can form the measurement core of a simple resistance meter using a reference and sense arrangement. According to the Analog Devices product description, the true differential reference path is particularly useful for ohms measurements because ratiometric operation can reduce sensitivity to reference variation. The device then drives a three-digit LED display directly through its integrated segment outputs. Design the excitation and current-limit network around the target resistance range, and follow the datasheet's input and reference configurations rather than treating the display side as an isolated load.
推薦
Bridge Transducer Readout
A bridge transducer readout benefits from the ICL7107CPL-3 because its true differential input is designed for measurement systems in which the signal is referenced to a complementary input. The dual-slope ADC rejects periodic interference, and the internal display driver produces a direct numerical result. This arrangement is useful for load cells, pressure bridges, and similar sensors after excitation and scaling. Keep the bridge excitation and analog input paths compact, establish the conversion timing around the required update rate, and verify input common-mode limits before finalizing the sensor interface.
推薦
Laboratory Digital Instrument
The ICL7107CPL-3 is useful for bench instruments that need an immediate three-digit numerical readout without a host processor. Integrating the reference, oscillator, converter, decoder, and segment driver reduces the component count compared with a discrete measurement design. The instrument can measure a conditioned voltage and present the result on a common-anode LED panel. For laboratory use, check the reference accuracy, input noise behavior, and common-mode range in the family datasheet; for portable equipment, verify supply current and conversion interval against the available power budget.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7107CPL-3 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7107CPL | ICL7107CPL+ | ICL7107CJL | ICL7107CPLZ | TC7107CPL |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Microchip Technology |
| Package | 40-PDIP | 40-PDIP | 40-PDIP | 40-PDIP | 40-PDIP | 40-PDIP |
| ADC Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
主要差異化特點
- Measurement and display drive share one 40-pin package (對比TC7107CPL)
- True differential measurement and reference paths (對比ICL7107CPL+)
- Dual-slope interference rejection (對比ICL7107CPL)
設計說明
Place the input, reference, oscillator, and decoupling networks according to the manufacturer connection diagram. The ICL7107CPL-3 is a measurement IC with direct display-drive outputs, so long analog traces should remain away from digit and segment routes. A compact ground-return arrangement helps prevent display current from shifting the reference or measurement input. Preserve the 40-pin PDIP pin-1 orientation and check every no-connect position before soldering.
Do not treat every ICL7107 suffix as electrically identical. Verify the operating-temperature grade, display polarity, and option code for the exact orderable MPN against the manufacturer selection table. ICL7107CPL-3 and ICL7107CPL can share a footprint while differing in qualification details. Confirm supply voltage, input range, conversion timing, and segment-drive ratings before approving a substitution.
Use the true differential input capability to reduce common-mode pickup, but place input filtering close to the converter and reference the analog ground appropriately. For bridge or resistance measurements, follow the manufacturer ratiometric reference arrangement so drift and switching noise do not dominate the result. Keep display-return currents away from sensitive sensor nodes and validate the filter values against the required conversion interval.
Budget power for both the measurement circuit and the seven-segment display because LED current can dominate total consumption. The converter requires stable supply and reference bypassing, while display segment duty cycle determines average LED load. Select series resistors from the datasheet display-drive limits and confirm that supply droop during digit transitions does not alter the displayed measurement.
合規資訊
The exact ICL7107CPL-3 order code is not identified as an automotive-qualified AEC-Q100 variant. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer or current product documentation.