INA217AIDWR - Low-Noise Instrumentation Amplifier | Texas Instruments
MPN: INA217AIDWR ✓ 啟用中INA217AIDWR 概覽
An instrumentation amplifier is a differential amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal gain architecture amplifies the difference between two input signals while rejecting common-mode interference. INA217 belongs to the instrumentation-amplifier hierarchy within amplifier ICs and analog signal-chain components. This makes it especially useful where a sensor or balanced source produces a small differential voltage alongside substantial system noise.
The INA217 combines 1.3 nV/√Hz noise at 1 kHz with a common-mode rejection ratio above 100 dB. Its distortion is specified as 0.004% THD+N at 1 kHz with a gain of 100, while its 800 kHz bandwidth at the same gain supports accurate acquisition of moderate-frequency signals. The wide ±4.5 V to ±18 V supply range supports both positive-only and dual-supply analog systems.
Current-feedback circuitry provides the INA217 with wide bandwidth and dynamic response across a broad range of externally selected gains. Near-theoretical noise performance is obtained with a 200 Ω source impedance. This combination is useful in professional microphone preamplifiers, balanced receivers, industrial measurement systems, and medical instrumentation where low-level signals must be amplified without adding excessive noise or distortion.
Typical applications include low-impedance balanced microphones, audio-console input stages, sensor-interface circuits, diagnostic equipment, and industrial signal conditioners. In a balanced microphone circuit, the INA217 rejects common-mode hum and interference while preserving a small differential voice or instrument signal. Its distortion performance also helps maintain fidelity in professional audio paths.
Design the external gain resistor carefully because resistor tolerance directly affects gain accuracy and noise contribution. Place input, feedback, and gain-setting components close to the device, maintain a quiet ground return, and follow the manufacturer layout guidance. Verify supply headroom, output swing, input common-mode range, and stability at the selected gain before releasing the PCB.
This product page combines manufacturer specifications, a verified package and pinout reference, commercial sourcing guidance, a drop-in SSM2017 replacement path, and practical guidance for low-noise PCB design. It is intended to help engineers compare bandwidth, noise, distortion, supply requirements, and replacement constraints before integrating the amplifier.
直接替換替代品,適用於 INA217AIDWR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA217AIDWR (相同外形與佔位) — 差異在於 Amplifier Type, Gain Configuration, Number of Circuits, Package.
SSM2017
✅ 直接替換📋 參考替代品(不在目錄中)
INA217AIDWR 最大額定值與電氣特性
| Amplifier Type | Low-noise, low-distortion instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Input Noise Density | 1.3 nV/√Hz at 1 kHz |
| Total Harmonic Distortion plus Noise | 0.004% at 1 kHz, gain = 100 |
| Bandwidth | 800 kHz at gain = 100 |
| Supply Voltage Range | ±4.5 V to ±18 V |
| Common-Mode Rejection | >100 dB |
| Gain Configuration | Externally set by resistor |
| Recommended Source Impedance | 200 Ω |
| 封裝 | 16-pin SOIC wide body (DW) |
| 腳位數 | 16 pins |
| 工作溫度範圍 | -40 °C to +125 °C |
| 安裝類型 | Surface mount |
| Primary Signal Type | Balanced low-level differential audio and instrumentation signals |
| Architecture | Current-feedback |
| Legacy Replacement | SSM2017-compatible package and pinout |
INA217AIDWR 16-pin soic wide body (dw) 腳位配置指南
INA217AIDWR(16-pin soic wide body (dw) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA217AIDWR.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA217AIDWR 適用於 6 應用s: Balanced Microphone Preamplifier, Professional Audio Input Conditioning, Precision Sensor Signal Acquisition, Medical Diagnostic Instrument Front End, Industrial Bridge and Strain-Gauge Amplification, Balanced Communications Receiver.
Balanced Microphone Preamplifier
INA217AIDWR fits professional balanced-microphone input stages because its 1.3 nV/√Hz noise at 1 kHz and greater than 100 dB common-mode rejection help preserve a small differential audio signal in the presence of hum and system interference. The 0.004% THD+N specification at 1 kHz and gain 100 supports low-distortion amplification. Place the external gain-setting resistor close to the device, connect the balanced source according to the manufacturer pin table, and provide clean dual-rail bypassing. Verify microphone impedance, maximum source current, and output swing before fixing the gain.
推薦
Professional Audio Input Conditioning
INA217AIDWR is suitable for balanced audio-console and line-input conditioning because the current-feedback architecture provides 800 kHz bandwidth at gain 100 and the low-noise, low-distortion characteristics preserve signal fidelity. Its ±4.5 V to ±18 V supply range accommodates several analog power architectures. The device can operate as a differential receiver when the source is balanced, reducing common-mode pickup without an input transformer. Keep the gain resistor compact, route the differential pair symmetrically, and maintain a low-impedance ground reference so the measured performance is not degraded by PCB leakage or unstable reference planes.
推薦
Precision Sensor Signal Acquisition
INA217AIDWR supports low-level sensor acquisition when the transducer produces a differential output smaller than the surrounding common-mode voltage. The specified noise density of 1.3 nV/√Hz reduces input-referred noise, while common-mode rejection above 100 dB improves rejection of shared supply and environmental interference. Near-theoretical noise performance is specified for a 200 Ω source, making source impedance an important design variable. Use the external gain resistor to establish the required range, protect the inputs against transients, and confirm that sensor excitation and return currents do not contaminate the amplifier ground path.
推薦
Medical Diagnostic Instrument Front End
INA217AIDWR is suitable for a diagnostic or monitoring front end requiring amplification of a low-level differential physiological or sensor signal. The 1.3 nV/√Hz noise at 1 kHz limits input-referred noise, and the 0.004% THD+N specification at 1 kHz and gain 100 supports signal-chain linearity. Its balanced-input architecture is useful when transducer leads can pick up common-mode noise. Validate leakage, input protection, isolation strategy, gain, bandwidth, and applicable medical-product requirements at the complete system level rather than treating device specifications alone as regulatory approval.
推薦
Industrial Bridge and Strain-Gauge Amplification
INA217AIDWR can amplify small differential outputs from bridge, strain-gauge, and other industrial sensors while rejecting common-mode excitation and coupled noise. The greater-than-100 dB common-mode rejection is valuable when the sensor output is much smaller than the excitation voltage. The 1.3 nV/√Hz input noise supports low-level measurements, while external gain setting permits scaling for a defined input range. Keep excitation and sensing returns separated, use Kelvin-style connections where available, and place the gain resistor near the relevant pins to minimize added thermal noise and parasitic feedback paths.
推薦
Balanced Communications Receiver
INA217AIDWR is appropriate for low-level balanced communications receivers in which the wanted signal is differential and common-mode interference originates from cables, power systems, or adjacent circuitry. Its 1.3 nV/√Hz noise density and greater-than 100 dB common-mode rejection improve signal extraction before a downstream converter or comparator. The 800 kHz bandwidth at gain 100 accommodates a useful range of moderate-frequency signals. Use shielded or twisted-pair interconnects, protect the receiver from electrostatic discharge, and confirm that input bias current and source impedance remain compatible with the selected gain resistor.
推薦
推薦產品摘要
工程參考資料,適用於 INA217AIDWR — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | SSM2017 |
|---|---|---|
| Package | SOIC-16 (DW) wide body | SOIC-16 wide body |
| Brand | Texas Instruments | Analog Devices |
| Amplifier Type | Low-noise, low-distortion instrumentation amplifier | Instrumentation amplifier |
主要差異化特點
- Documented low-noise replacement for the legacy SSM2017 (對比SSM2017)
- Strong common-mode rejection for balanced measurement (對比SSM2017)
- High bandwidth at high gain (對比SSM2017)
設計說明
Place the external gain-setting resistor close to the corresponding INA217 pins and keep the feedback and input-network paths short. Use a compact ground plane and symmetrical routing for the differential input pair. Long copper traces can increase parasitic capacitance, pickup, and sensitivity to unstable references, which can reduce the benefit of the 1.3 nV/√Hz noise specification.
Keep supply and return paths short, place bypass capacitors at the device power pins, and isolate the analog signal from switching nodes and high-current returns. The INA217AIDWR operates from ±4.5 V to ±18 V, so verify local rail voltage under full signal load and ensure the ground reference does not share high-impedance sensor-return paths.
Do not substitute an SSM2017 DIP-8 implementation for the 16-pin SOIC footprint. INA217AIDWR is specifically the wide-body SOL-16 version, and the manufacturer states that compatible SSM2017 options use the same DIP-8 or SOL-16 wide-body pinouts. Confirm the exact footprint, gain network, supply arrangement, and input bias requirements before approving a legacy replacement.
合規資訊