ISL8392IB - 4-Channel 35Ω SPST Analog Switch | Renesas
MPN: ISL8392IB ✗ 停產ISL8392IB 概覽
An analog switch is a semiconductor-controlled pass element that connects or isolates circuit nodes under digital control. The ISL8392 family belongs to the interface IC hierarchy: analog switch → switch/multiplexer IC → interface integrated circuit. Its SPST configuration provides one conducting path per switch rather than a multi-channel multiplexer, making it useful when each signal requires independent routing.
Verified device features include a maximum charge injection of 5 pC, on-resistance matching of 300 mΩ, and crosstalk of -89 dB at 1 MHz. The family data also identifies low power consumption of 1 µW, leakage current up to 2.5 nA, turn-on time of 60 ns, turn-off time of 30 ns, and maximum on-resistance flatness of 4 Ω. These characteristics suit signal paths where fast transitions, low leakage, and controlled charge injection are important.
The switch architecture is designed for low-voltage precision routing rather than high-voltage power switching. Signal amplitude, supply range, input capacitance, control-logic levels, and switched leakage must all remain within device limits. Because ISL8392IB is listed as obsolete by GlobalSpec, new production designs should account for lifecycle risk and contact Renesas regarding supported sourcing before committing an active BOM.
Typical uses include battery-powered sensor acquisition, multimeter and test-equipment input routing, sample-and-hold systems, data-acquisition modules, and low-power analog signal multiplexing. The 60 ns turn-on and 30 ns turn-off values can limit settling intervals, while 2.5 nA maximum leakage helps preserve weak-source measurements between switching events.
Use the 16-SOIC footprint exactly as shown in the manufacturer pinout, and observe all control pins during unused channels. Do not infer the complete pin map or absolute maximum ratings from distributor snippets alone. Validate signal integrity, supply sequencing, and injected charge in the final analog channel because package parasitics and PCB capacitance can materially affect precision measurements.
This page consolidates verified lifecycle, electrical, package, cross-reference, and sourcing information with engineering guidance that extends beyond a distributor listing. It also clearly separates confirmed data from parameters that still require datasheet or internal-inventory confirmation.
直接替換替代品,適用於 ISL8392IB — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
ISL8392IBZ
✅ 直接替換📋 參考替代品(不在目錄中)
ISL8392IBZ-TR
✅ 直接替換📋 參考替代品(不在目錄中)
ISL8392IB 最大額定值與電氣特性
| Number of Switches | 4 circuits |
| Switch Configuration | 1:1 SPST |
| Typical On-Resistance | 35 Ω |
| Single-Supply Operating Range | +2 V to +12 V |
| Dual-Supply Operating Range | ±2 V to ±6 V |
| Low Power Consumption | 1 µW |
| Maximum Leakage Current | 2.5 nA |
| Turn-On Time | 60 ns |
| Turn-Off Time | 30 ns |
| Maximum Charge Injection | 5 pC |
| Crosstalk | -89 dB at 1 MHz |
| On-Resistance Matching | 300 mΩ |
| Maximum On-Resistance Flatness | 4 Ω |
| 封裝 | 16-SOIC |
| 安裝類型 | Surface mount |
ISL8392IB 16-soic 腳位配置指南
ISL8392IB(16-soic 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ISL8392IB.
請參閱 資料表 以查看完整腳位配置。
典型應用
ISL8392IB 適用於 6 應用s: Battery-Powered Sensor Acquisition, Multimeter and Instrumentation Routing, Data-Acquisition Multiplexing, Sample-and-Hold Signal Control, Industrial Control Signal Isolation, Portable Medical Monitoring.
Battery-Powered Sensor Acquisition
ISL8392IB fits low-voltage sensor-acquisition boards because its family operates from +2 V to +12 V, consumes approximately 1 µW, and limits leakage to 2.5 nA. Place the four switches between sensor outputs and the measurement amplifier or ADC input, and use the 60 ns turn-on and 30 ns turn-off figures for an initial timing estimate. The 35 Ω typical on-resistance adds to source impedance, so verify amplifier bias current and acquisition settling rather than assuming the switching delay alone determines accuracy.
推薦
Multimeter and Instrumentation Routing
The four independent SPST channels make ISL8392IB useful for compact test and measurement routing, where source signals must be connected or isolated under digital control. Its 5 pC maximum charge injection and 2.5 nA maximum leakage are relevant when switching high-impedance probes, while -89 dB crosstalk at 1 MHz helps limit inter-channel coupling. In an instrument front end, place switches close to protected input nodes and verify leakage, capacitance, and injected transient against the required measurement uncertainty.
推薦
Data-Acquisition Multiplexing
ISL8392IB can route four precision analog inputs when a system uses independent control rather than a monolithic multiplexer architecture. Its 35 Ω typical on-resistance contributes to the source-to-ADC transfer function, while the 60 ns and 30 ns switching times define the first transition stage. The exact acquisition interval must also account for the ADC sampling capacitor, source impedance, switch capacitance, and the number of clock cycles allowed for settling.
推薦
Sample-and-Hold Signal Control
For sample-and-hold or switched-capacitor front ends, ISL8392IB provides fast SPST routing with a listed 30 ns turn-off time and 60 ns turn-on time. Its maximum charge injection of 5 pC can create an error voltage when applied to the sampling node, making the held capacitance a critical design variable. Estimate the transient as charge divided by total node capacitance, then verify leakage and settling over the intended temperature and supply conditions.
推薦
Industrial Control Signal Isolation
ISL8392IB can isolate or reconnect low-level analog control paths in industrial electronics when the signal remains within its low-voltage range. The dual-supply capability of ±2 V to ±6 V supports bipolar systems without requiring a separate positive-only arrangement. Validate control thresholds, input overvoltage tolerance, and isolation intent, since the SPST switches themselves provide routing control but are not presented as certified galvanic isolation barriers.
推薦
Portable Medical Monitoring
The low-power operation and low-leakage characteristics make ISL8392IB a candidate for portable monitoring signal paths that operate from low-voltage supplies. Four SPST switches can connect sensor inputs, test points, or calibration nodes while limiting inactive leakage to the verified 2.5 nA maximum. Because no medical qualification is supplied, this use is suitable only for supporting analog routing within an appropriately qualified system; signal limits, isolation, patient protection, and standards compliance remain separate design requirements.
推薦
推薦產品摘要
工程參考資料,適用於 ISL8392IB — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ISL8392IBZ | ISL8392IBZ-TR |
|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Package | 16-SOIC | 16-SOIC | 16-SOIC |
| Switch Configuration | 4-circuit 1:1 SPST | Similar switching characteristics; exact configuration not verified | Similar switching characteristics; exact configuration not verified |
主要差異化特點
- Documented precision quad-switch function (對比ISL8392IBZ-TR)
- Explicit low-voltage operating ranges (對比ISL8392IBZ)
- Defined leakage and channel-matching targets (對比ISL8392IBZ)
設計說明
Validate switch settling with the actual source impedance and receiver capacitance rather than relying only on the listed 60 ns turn-on or 30 ns turn-off time. Estimated: with a 35 Ω on-resistance and 1 nF effective node capacitance, the RC time constant is approximately 35 ns, so one time constant is not sufficient for a high-accuracy settled reading. This estimate excludes package, PCB, ADC sample-switch, and signal-source impedances and must be confirmed in hardware.
Do not treat SPST routing as galvanic isolation. The switch controls connection between analog nodes and may still allow charge injection, leakage, power-domain coupling, or ESD events according to its absolute maximum ratings. Confirm signal amplitude, supply sequencing, control logic levels, and unused-channel states from the complete manufacturer datasheet before treating the switched path as a safety boundary.
Route switched analog signals as short, guarded traces and place control circuitry away from sensitive nodes to reduce capacitive pickup. Keep supply and ground connections capable of handling the transient current produced by 30 ns to 60 ns switching, and use a local bypass strategy appropriate to the complete datasheet. PCB leakage and contamination can become significant when the 2.5 nA leakage figure is used near high-impedance sources.
Use either the single-supply range of +2 V to +12 V or the dual-supply range of ±2 V to ±6 V as documented, without assuming arbitrary combinations are valid. Estimated charge-injection voltage equals 5 pC divided by the total held-node capacitance, but the input values for capacitance and distributed parasitic effects are design-specific. Confirm startup, shutdown, and control-pin states to prevent unintended analog paths during power transitions.
合規資訊
The supplied verified excerpts do not provide exact-MPN RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations. GlobalSpec identifies ISL8392IB as obsolete. Compliance must be confirmed from current Renesas environmental or product documentation.