LT1990IS8 - ±250V Difference Amplifier | Analog Devices
MPN: LT1990IS8 ✓ 啟用中LT1990IS8 概覽
A difference amplifier is a specialized analog amplifier that subtracts two input voltages and amplifies the resulting differential signal. The subtraction rejects common-mode voltage, allowing a small voltage difference to be measured even when both inputs sit at a high potential. In the broader electronics hierarchy, the LT1990IS8 is an amplifier IC and a special-purpose difference amplifier designed to combine precision gain, limited power consumption, and unusually high input-voltage tolerance.
The LT1990 family offers pin-selectable gains of 1 or 10. This lets one circuit accommodate either direct differential measurement or a higher-gain sensing stage without changing the package. The industrial-temperature LT1990IS8 is supplied in an 8-pin SOIC package, while the manufacturer also lists the LT1990 as a product recommended for new designs. Its micropower architecture supports instrumentation where continuous analog monitoring must coexist with limited power budgets.
Operationally, the LT1990 uses the difference between its two inputs as the signal of interest. A common-mode input range of ±250V under a ±15V supply is the defining electrical characteristic because it separates the tolerable input voltage from the supply rails. Input fault protection extends the transient tolerance to ±350V. These are not conventional rail-to-rail input limits; the LT1990 is intended to remain functional when the measured node itself is far above or below the local supply voltage.
Typical uses include high-side sensing in power systems, detecting small voltage errors across high-voltage buses, amplifier input conditioning in industrial controllers, and low-level differential measurements in laboratory equipment. The gain setting should be selected only after confirming the maximum differential signal, allowable output swing, and input bias requirements. High common-mode capability does not remove the need to constrain differential input voltage.
For a robust implementation, keep input and feedback networks away from the high-voltage pins, provide suitable input protection for sustained out-of-range conditions, and verify output headroom at the selected gain. Fault protection is intended to improve resilience during transients, but it is not a substitute for a correctly engineered external protection network or an appropriately rated measurement system.
This page combines the manufacturer’s stated voltage-range, gain, supply, protection, package, and lifecycle information with practical differentiation guidance, comparison parameters, sourcing information, and design notes. The result is a focused engineering reference for engineers determining whether the LT1990IS8 can measure small differential signals in high-common-mode environments without changing the PCB footprint.
直接替換替代品,適用於 LT1990IS8 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
LT1990CS8#PBF
✅ 直接替換📋 參考替代品(不在目錄中)
LT1990-10
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
LT1990-10CS8#PBF
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
LT1990-10IS8#PBF
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
LT1990IS8#PBF
✅ 直接替換📋 參考替代品(不在目錄中)
LT1990IS8 最大額定值與電氣特性
| Device Type | Precision difference amplifier |
| Number of Amplifiers | 1 circuit |
| Common-Mode Input Voltage Range | ±250 V on a ±15 V supply |
| Input Transient Fault Protection | Up to ±350 V common-mode transients |
| Selectable Gain | 1 or 10 |
| 供應電壓 | ±15 V |
| Power Class | Micropower |
| 輸出類型 | Rail-to-rail |
| 封裝 | 8-pin SOIC |
| Package Code | S8 |
| Temperature Grade | Industrial |
| 安裝類型 | Surface mount |
| Terminal Count | 8 |
| Termination Form | Gull wing |
LT1990IS8 s8 腳位配置指南
LT1990IS8(s8 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: LT1990IS8.
請參閱 資料表 以查看完整腳位配置。
典型應用
LT1990IS8 適用於 6 應用s: Industrial High-Side Sensing, Power-Supply Error Detection, Precision Test and Measurement, Battery and Energy-System Monitoring, Signal-Conditioning Front End, Automotive Electrical-Node Monitoring.
Industrial High-Side Sensing
The LT1990IS8 fits high-side sensing because its common-mode input range reaches ±250V on a ±15V supply, allowing a small differential voltage to be measured in a higher-voltage node. The amplifier subtracts the two input voltages rather than requiring either input to remain near the local supply rails. Select gain 1 or 10 according to the differential signal magnitude, then verify output headroom and bandwidth. External input resistors and protection components must be rated for the working voltage, while fault protection to ±350V should be treated as transient resilience rather than a continuous operating condition.
推薦
Power-Supply Error Detection
The LT1990IS8 can monitor the difference between two high-side nodes, such as a sensed power rail and a reference point, while rejecting the large common-mode voltage present on both inputs. Its selectable gains of 1 and 10 provide a practical way to amplify either a large imbalance or a small error signal. The ±15V operating supply supports conventional analog rails, while the ±250V common-mode capability decouples input voltage from supply voltage. Confirm maximum differential input, output swing, settling behavior, and the protection network before using the device in a power-control feedback path.
推薦
Precision Test and Measurement
The LT1990IS8 is useful in test equipment that must measure the difference between two high-voltage nodes or compare a high-level signal with a reference. Difference amplification rejects common-mode variation, improving measurement discrimination when both inputs change together. Gain can be selected as 1 or 10 to suit the test range, while the micropower classification supports low-power instrumentation. The instrument designer must still account for input leakage, resistor accuracy, output noise, bandwidth, and calibration. The high input range should be paired with appropriately rated front-end components and safe test-probe layouts.
推薦
Battery and Energy-System Monitoring
The LT1990IS8 can sense small voltage differences within a higher-voltage battery or energy-system bus because its inputs tolerate a ±250V common-mode environment on a ±15V supply. This is useful for cell balancing, imbalance detection, or monitoring a differential measurement network without grounding the sensed bus. Gain 10 increases sensitivity when the target difference is small. The circuit must maintain adequate input headroom, use low-leakage protection components, and keep the output within its usable swing. Firmware or control hardware should also include threshold filtering so normal switching transients do not create false imbalance alarms.
推薦
Signal-Conditioning Front End
The LT1990IS8 can serve as the first precision difference stage ahead of an instrumentation chain when a small sensor or bridge output sits on a large common-mode voltage. Its gain choices of 1 and 10 allow the input stage to be adapted without changing the physical package. The rail-to-rail output helps maximize usable signal range on the local supply. Designers should compare the fixed-gain LT1990-10 when gain 10 is always required, but retain the LT1990IS8 when flexible gain selection is valuable. Verify input bias current, offset, noise, and settling against the source impedance.
推薦
Automotive Electrical-Node Monitoring
The LT1990IS8 is architecturally suitable for measuring small differential signals in automotive electrical systems where common-mode voltage can be far above the amplifier supply. The industrial temperature grade provides a useful starting point, but automotive qualification must not be inferred from that designation. Confirm the exact ordering code, temperature limits, AEC-Q100 status, transient immunity, and load-dump requirements before using it in a safety-related vehicle design. A qualified external protection network and careful PCB creepage and clearance design are as important as the amplifier's stated ±250V common-mode range.
推薦
推薦產品摘要
工程參考資料,適用於 LT1990IS8 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | LT1990CS8#PBF | LT1990-10 | LT1990-10CS8#PBF | LT1990-10IS8#PBF | LT1990IS8#PBF |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-pin SOIC (S8) | 8-pin SOIC (S8) | 8-pin SOIC (S8) | 8-pin SOIC (S8) | 8-pin SOIC (S8) | 8-pin SOIC (S8) |
| Device Type | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier | Precision difference amplifier |
| Common-Mode Input Range | ±250 V on a ±15 V supply | ±250 V on a ±15 V supply | ±250 V on a ±15 V supply | ±250 V on a ±15 V supply | ±250 V on a ±15 V supply | ±250 V on a ±15 V supply |
| Gain | Selectable 1 or 10 | Selectable 1 or 10 | Fixed 10 | Fixed 10 | Fixed 10 | Selectable 1 or 10 |
| Number of Circuits | 1 | 1 | 1 | 1 | 1 | 1 |
主要差異化特點
- Selectable gain supports both direct measurement and greater sensitivity (對比LT1990-10)
- The LT1990IS8 supports gain-1 operation without changing the package (對比LT1990-10CS8#PBF)
- Industrial-temperature ordering option suits non-automotive industrial designs (對比LT1990CS8#PBF)
- Lead-free ordering code preserves the same electrical configuration (對比LT1990IS8#PBF)
設計說明
Do not interpret the ±350V transient-fault rating as a continuous common-mode operating rating. The specified operating range is ±250V on a ±15V supply. Use series input resistance, appropriately rated clamping devices, and a layout that prevents sustained overvoltage or excessive clamp current. Confirm that the external protection network adds acceptable noise, leakage, and capacitance to the precision difference-amplifier input network.
Keep the high-voltage input routing physically separated from low-level output and ground paths to minimize differential pickup and coupling. Use a compact protection network close to the LT1990IS8 pins, provide local supply bypassing, and avoid long parallel traces that can act as capacitive antennae. The SOIC body limits exposed thermal area, so place the device where airflow is available if its total dissipation becomes significant.
Calculate the maximum differential input before selecting gain 10. The common-mode range does not imply unlimited differential input, and increasing gain by a factor of 10 also multiplies signal swing and noise. Verify output headroom, source impedance effects, input bias current, and settling time for the selected operating frequency. The fixed-gain LT1990-10 is appropriate only when the gain and bandwidth requirements align with its stated 100kHz bandwidth.
Decouple each supply rail near the device with low-inductance ceramic capacitance and follow the manufacturer layout recommendations. Because the input common-mode range is much wider than the supply range, ground-reference quality and input-network leakage become especially important. Use a clean analog return path and evaluate whether the external protection components introduce leakage or ground currents that could degrade low-level differential measurements.
合規資訊
The available product information does not explicitly state compliance for this exact ordering code. The PBF suffix identifies a lead-free ordering option, but lead-free, halogen-free, RoHS, REACH, and AEC-Q100 status should be confirmed from the manufacturer’s current declaration or product documentation.