Maxim Integrated

MAX133CMH+ - 3.75-Digit 20 CPS ADC | Maxim | Multimeter

MPN: MAX133CMH+ ✗ 停產
44-pin MQFP (10 mm × 10 mm) Package
MOQ: 1 |

MAX133CMH+ 概覽

The Maxim Integrated MAX133CMH+ is a 3.75-digit integrating analog-to-digital converter with a 20-conversion-per-second sampling rate, 50 ms conversion time, and ±40,000-count internal resolution. It is supplied in a 44-pin MQFP package measuring 10 mm by 10 mm. The converter is designed specifically for 3.75-digit digital multimeters and related data-acquisition systems.

An integrating analog-to-digital converter is a voltage-to-digital conversion IC that integrates an input voltage over a fixed measurement interval. This measurement category belongs to the broader ADC hierarchy, which supports instrumentation, data logging, weighing, process monitoring, and panel-meter designs. Unlike successive-approximation ADCs, integrating converters are commonly selected when low-frequency measurements and specific front-end characteristics are important.

The MAX133 provides a nominal 3.75-digit indication with internal resolution of ±40,000 counts. Its extra guard digit supports autozero or tare operations that reduce the effect of offset when displaying a 4,000-count measurement, providing resolution equivalent to one tenth of a displayed count. Its 50 ms conversion time corresponds to the verified sampling rate of 20 conversions per second. The one-channel integrating architecture is tailored for direct measurement and front-panel instrument use.

The MAX133 and MAX134 form closely related integrating ADC families for digital multimeters, data loggers, and weigh scales. Their functional emphasis is measurement resolution rather than high-speed signal acquisition. Because the MAX133 is designed around the behavior of a 3.75-digit meter, its input network, reference arrangement, integration period, and display-processing strategy must be evaluated together when designing a new analog measurement board.

Typical uses include handheld and bench digital multimeters, panel meters, weighing instruments, laboratory data loggers, and low-frequency industrial monitoring systems. The MAX133 can support the central measurement path where a regulated reference, input conditioning, and the meter’s display and controls are coordinated. The 44-pin MQFP package provides the pins required for analog inputs, reference connections, digital interface signals, supply rails, and associated control functions.

Designers should preserve the recommended analog and reference layout because integrating converters remain sensitive to reference noise, grounding, leakage, and unwanted input signals during the 50 ms conversion interval. Input filtering should be selected for the intended source impedance rather than for the highest possible bandwidth. Power sequencing, bypass placement, and separation between the measurement input and digital interface also deserve attention.

This page consolidates verified manufacturer and distributor information with practical application guidance, package-aware alternatives, comparison parameters, and design notes. It also identifies where source data does not establish a complete pinout, electrical limit, or verified drop-in cross-reference rather than filling those gaps with assumptions.

直接替換替代品,適用於 MAX133CMH+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

MAX134CMH+

✅ 直接替換
Maxim Integrated
📦 44-pin MQFP (10 mm × 10 mm)
Integrating analog-to-digital converter · 3.75 digits · ±40,000 counts · 4,000 counts · 1/10 of a displayed count · 50 ms · 44-MQFP (10 mm x 10 mm) · 44 terminals

聯絡詢價

查看資料表 →

MAX133CMH+D

✅ 直接替換
📦 44-pin MQFP (10 mm × 10 mm)
Listed ordering option with the same 3.75-digit resolution, 20-samples/s rate, and 44-pin MQFP format; the suffix-specific electrical and ordering differences are not quantified in the supplied excerpts.

📋 參考替代品(不在目錄中)

MAX133CMH+ 最大額定值與電氣特性

ADC Type Integrating analog-to-digital converter
Displayed Resolution 3.75 digits
Internal Resolution ±40,000 counts
Guard-Digit Resolution 1/10 of a displayed count
Conversion Time 50 ms
取樣率 20 samples/s
Channel Count 1 channel
Conversion Method Proprietary integrating method
封裝 44-pin MQFP (10 mm × 10 mm)
Package Family MQFP
Terminal Count 44 terminals
Terminal Form Gull wing
Package Shape Square
Temperature Grade Commercial
RoHS 狀態 Compliant

MAX133CMH+ square 腳位配置指南

MAX133CMH+(square 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

MAX133CMH+ 的 square 封裝腳位圖

無詳細腳位定義資料: MAX133CMH+.

請參閱 資料表 以查看完整腳位配置。

典型應用

MAX133CMH+ 適用於 6 應用s: Handheld Digital Multimeter, Bench-Top Measurement Instrument, Weigh-Scale Front End, Industrial Data Logger, Digital Panel Meter, Low-Frequency Process Monitoring.

🔧

Handheld Digital Multimeter

The MAX133CMH+ is suited to the central measurement channel of a 3.75-digit handheld multimeter because the manufacturer positions the MAX133 specifically for integrating ADCs used in these instruments. Its 50 ms conversion time supports a 20-conversion-per-second operating rate, while the ±40,000-count internal resolution provides a guard-digit range beyond the nominal 3.75-digit display. The meter frontend can use this extra resolution for autozero, tare, reference correction, or display scaling. Designers must still implement the input protection, range switching, reference source, and calibration sequence required by the complete measurement path.

🔬

Bench-Top Measurement Instrument

MAX133CMH+ can form the measurement core of a bench-top instrument requiring a stable numeric reading rather than a high-speed waveform. Its 3.75-digit format, 50 ms conversion interval, and ±40,000-count internal range align with panel instruments, laboratory meters, and service equipment that update at a human-readable rate. The extra guard digit supports autozero or tare to one tenth of a displayed count, which can improve offset behavior without changing the displayed digit count. For laboratory use, reference stability and input leakage are as important as the ADC itself because they directly determine the accuracy of the displayed measurement.

⚖️

Weigh-Scale Front End

The MAX133CMH+ is appropriate for a low-speed weigh-scale front end where load-cell voltage changes are converted into stable displayed counts. Analog Devices explicitly identifies weigh scales among the data-acquisition applications for the MAX133 family. A 50 ms conversion time provides 20 readings per second, a useful rate for a stationary platform or slowly changing load, while the ±40,000-count internal range offers resolution beyond the 3.75-digit user-facing display. The instrumentation amplifier, excitation source, bridge wiring, shielding, and system calibration must be designed around the converter’s specified input and reference requirements.

🏭

Industrial Data Logger

MAX133CMH+ fits an industrial data logger that records slowly changing process variables such as temperature, pressure, or tank level. The converter’s 20-samples/s rate is sufficient for supervisory measurements without the timing demands of a high-speed acquisition system. Its integrating architecture, 3.75-digit format, and extra guard digit support repeatable panel readings and front-end offset correction. In a field logger, however, long cable runs and noisy transducers require careful isolation, filtering, grounding, and reference design; otherwise, environmental interference can dominate the ADC measurement even when the displayed conversion count is adequate.

📺

Digital Panel Meter

MAX133CMH+ provides the measurement function for a digital panel meter that presents a stable 3.75-digit value of a conditioned analog signal. The 50 ms conversion period is appropriate for panel updates, and the ±40,000-count internal resolution can support calibration or autozero operations beyond the visible display resolution. A practical implementation can use the converter output with a display controller and input-conditioning network to monitor supply, temperature, pressure, or position. The analog input should be bandwidth-limited to the slow signal being measured, while the reference and power layout should minimize noise that could create flickering or inconsistent panel readings.

🌐

Low-Frequency Process Monitoring

MAX133CMH+ can be used in a low-frequency process-monitoring subsystem where the controller needs repeated numeric measurements rather than continuous high-rate sampling. Its 20-conversions-per-second capability gives a defined update cadence, and the integrating conversion method is consistent with the slow response of many temperature, level, and pressure sensors. The extra internal count range offers flexibility for offset compensation and calibration. System designers must verify that the complete MAX133 electrical specification supports the selected sensor excitation, signal range, reference arrangement, and environmental isolation, because those conditions are not established by the supplied excerpts.

推薦產品摘要

MAX133CMH+D Same-family integrating ADC ordering option 用於: Handheld Digital Multimeter, Bench-Top Measurement Instrument, Weigh-Scale Front End, Industrial Data Logger, Digital Panel Meter, Low-Frequency Process Monitoring MAX134CMH+ Maxim Integrated 用於: Handheld Digital Multimeter, Bench-Top Measurement Instrument, Weigh-Scale Front End, Industrial Data Logger, Digital Panel Meter, Low-Frequency Process Monitoring
What are the key specifications of MAX133CMH+ that engineers should know?
The MAX133CMH+ is a 3.75-digit integrating ADC with ±40,000-count internal resolution, a 50 ms conversion time, and a 20-samples/s conversion rate. According to the Analog Devices MAX133 product page, the extra guard digit supports autozero or tare of a 4,000-count displayed reading to one tenth of a displayed count. The device is packaged as a 44-pin MQFP in a 10 mm by 10 mm body, making it primarily suited to digital multimeters, data loggers, panel meters, and weigh-scale front ends.
Where can I download the MAX133CMH+ datasheet PDF?
The official MAX133CMH+ technical information is available through the Analog Devices MAX133 product page at https://www.analog.com/en/products/MAX133.html. The verified manufacturer result identifies the MAX133 as an integrating ADC for 3.75-digit multimeters and data-acquisition systems. The page is the appropriate starting point for the current datasheet, package drawings, electrical characteristics, ordering information, and lifecycle information, although the supplied web excerpts do not expose a separate direct PDF filename.
Where can I find the MAX133CMH+ pinout?
The MAX133CMH+ pinout must be obtained from the official MAX133 package drawing and pin-description tables because the supplied verified excerpts do not provide individual pin numbers or signal names. The component is identified as a 44-pin MQFP with gull-wing terminals in a square 10 mm by 10 mm package. The selected package representation is QFP-44, but no complete pin assignment is asserted here without a manufacturer-verified table, preventing incorrect orientation or signal connections.
What is the conversion time and sampling rate of MAX133CMH+?
The MAX133CMH+ performs one conversion every 50 ms, corresponding to 20 conversions per second. According to the Analog Devices MAX133 product information, the converter is intended for 3.75-digit multimeters and data-acquisition systems rather than high-speed waveform acquisition. This timing makes it appropriate for slow-changing voltage measurements, instrument panel readings, weigh-scale values, and logged process quantities where an integrating measurement period is useful.
Why does the MAX133 use a 3.75-digit format with ±40,000 counts?
The MAX133 combines a 3.75-digit displayed format with ±40,000-count internal resolution to provide additional measurement granularity. According to Analog Devices, the extra guard digit allows autozero or tare of a 4,000-count displayed reading to one tenth of a displayed count. This extra internal range can compensate for offset or establish a reference baseline, although it does not mean the meter displays more than 3.75 digits.
Where to buy MAX133CMH+ online?
MAX133CMH+ can be located through the verified Analog Devices product page, DigiKey, Mouser, Octopart, and DiGi-Electronics listings. Octopart reports availability and pricing comparisons from four distributors, while the DiGi-Electronics result identifies the MAX133CMH+ as an ADC in a 44-pin MQFP. The available list price reference is USD 10.1605 as of 2026-10-28; confirm the exact suffix, stock position, and order quantity before purchasing.
What is the price of MAX133CMH+?
The available verified price reference is USD 10.1605 as of 2026-10-28, taken from the LCSC listing for the closely identified MAX133CMH+TD ordering code. The exact MAX133CMH+ offer should be reconfirmed with a distributor because the supplied excerpt labels the result as a tape-and-reel variant. XAIPART tiers retain the sourced USD 10.1605 reference rather than inventing unverified volume breaks.
What is the lead time for MAX133CMH+?
The exact lead time for MAX133CMH+ is not stated in the supplied verified web data. The DiGi-Electronics listing reports the part in stock with fast delivery, and the Octopart result compares four distributors, but neither excerpt provides a contractual lead-time figure. A distributor quote is therefore required for a production schedule. The available price reference is USD 10.1605 as of 2026-10-28, subject to confirmation of the exact ordering suffix.
Is MAX133CMH+ in stock?
The verified DiGi-Electronics result for MAX133CMH+ states that it is in stock and available for fast delivery. The LCSC result likewise identifies the closely identified MAX133CMH+TD ordering code as in stock, with a listed price starting at USD 10.1605 as of 2026-10-28. Stock quantity can change rapidly, so engineers should obtain current inventory and lead-time confirmation directly from the selected authorized distributor.
MAX133CMH+ vs MAX134CMH+ — which is better for a multimeter?
MAX133CMH+ is the appropriate choice when the meter design targets the specified MAX133 operating arrangement, while MAX134CMH+ should be selected when its different supply or input requirement matches the instrument architecture better. The Analog Devices product page confirms that MAX133 and MAX134 are closely related integrating ADCs and differ only in an aspect not fully visible in the supplied excerpt. Both are associated with 3.75-digit multimeters, so the final choice must be checked against complete electrical limits and reference voltage.
When should I choose MAX133CMH+ instead of MAX133CMH+D?
Choose MAX133CMH+ when the distributor order code and manufacturer package designation exactly match the component intended for the PCB and BOM. The verified web data identifies MAX133CMH+D as the same 3.75-digit, 20-conversion-per-second ADC in a 44-MQFP package. Because the excerpts do not fully define whether the suffix difference is a temperature, package, finish, or ordering option, engineers should compare the complete ordering table and landed-device markings before treating one as a substitute.
Is MAX133CMH+ suitable for data loggers and panel meters?
Yes, MAX133CMH+ is suitable for low-frequency data loggers and digital panel meters because it is an integrating ADC intended for 3.75-digit multimeters and data-acquisition systems. Its 50 ms conversion time and 20-samples/s rate fit slowly changing measurements such as temperature, pressure-derived signals, load-cell outputs, and panel-meter readings. The meter controller must still provide the correct reference, input conditioning, display processing, and calibration sequence.
What is the best drop-in replacement for MAX133CMH+?
The strongest documented same-family candidate is MAX134CMH+, because the Analog Devices product page identifies MAX133 and MAX134 as closely related 3.75-digit integrating converters, but the supplied excerpt does not fully establish its supply-voltage difference or provide a formal pin-compatibility statement. MAX133CMH+D is another listed 44-MQFP ordering option. No verified cross-brand pin-compatible replacement was found, so a drop-in substitution should not be approved until the complete MAX134 data sheet and footprint comparison are reviewed.
What can replace MAX133CMH+ on the same PCB?
No verified cross-brand part can be asserted as a direct PCB replacement for the MAX133CMH+. MAX134CMH+ is the relevant same-family comparison, while MAX133CMH+D is a listed ordering variant in the same 44-MQFP format. Both require confirmation of electrical compatibility, pin assignment, and exact package dimensions against the current manufacturer documentation. A functional converter using a different package would require PCB redesign and is not a drop-in replacement.
Is MAX133CMH+ RoHS compliant?
Yes, the verified FindIC result for MAX133CMH+D identifies the MAX133 family as RoHS compliant. The manufacturer product page confirms the MAX133 family, and the verified distributor listings identify the 44-MQFP device. The supplied excerpts do not separately establish REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for the exact MAX133CMH+ suffix, so those fields remain unknown rather than being inferred from family-level information.

工程參考資料,適用於 MAX133CMH+ — 比較、設計指引及合規資訊。

選型指南

Choose MAX133CMH+ for a 3.75-digit multimeter, panel meter, data logger, or weigh-scale design that specifically targets the MAX133 measurement architecture. Its verified 50 ms conversion time, 20-samples/s rate, and ±40,000-count internal resolution are well aligned with slow-changing analog measurements. Select MAX134CMH+ only after confirming its different supply or input characteristic against the complete instrument design; it belongs to the same integrating-ADC family but the supplied evidence does not quantify every parameter. MAX133CMH+D offers the closest documented ordering comparison in the same 44-MQFP format, although the suffix-specific ordering information must be checked. No verified cross-brand drop-in equivalent was identified, so do not substitute a generic ADC merely because it offers 3.75-digit resolution or 20 samples/s. For new designs, prioritize the exact manufacturer order code, complete electrical limits, reference arrangement, input configuration, and verified footprint before committing the PCB.

與替代品比較

參數 本產品 MAX134CMH+ MAX133CMH+D
Package 44-pin MQFP (10 mm × 10 mm) 44-pin MQFP 44-pin MQFP (10 mm × 10 mm)
Brand Maxim Integrated Maxim Integrated Maxim Integrated
ADC Type Integrating ADC Integrating ADC Integrating ADC
Displayed Resolution 3.75 digits 3.75 digits 3.75 digits

主要差異化特點

  • Purpose-built 3.75-digit instrument resolution (對比MAX134CMH+)
  • Defined 50 ms conversion timing (對比MAX134CMH+)
  • Same 44-MQFP format as the listed ordering option (對比MAX133CMH+D)

設計說明

Keep the measurement input, reference network, converter ground, and supply bypass in a compact analog region. The integrating conversion process depends on accurate reference and input behavior throughout each 50 ms measurement interval, so long traces and high-impedance nodes can increase error. Route digital interface signals away from sensitive analog pins, use a continuous ground reference where appropriate, and verify the final layout against the manufacturer’s recommended PCB example.

Do not assume that the 3.75-digit display rating specifies the complete input or reference range. The supplied excerpts establish ±40,000-count internal resolution but do not provide the supply voltage, differential or single-ended input configuration, or reference voltage. Obtain the complete MAX133 electrical characteristics before selecting divider values, protection components, or reference circuitry. Likewise, the MAX134CMH+ alternative should not be approved solely from its family relationship because its differentiating operating parameter is not quantified in the verified excerpt.

Band-limit the analog input according to the slowest signal of interest rather than exposing the measurement node to unnecessary high-frequency noise. Excess bandwidth can disturb an integrating conversion and increase variability in the displayed result. Place input filtering close to the converter or the measurement front end, use components with suitable temperature coefficients and leakage behavior, and evaluate the complete source impedance and settling sequence. The guard-digit resolution should be used for calibration or autozero only after those system-level errors are controlled.

合規資訊

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

RoHS-compliant status is stated in the verified MAX133CMH+D family result. The supplied excerpts do not establish exact-suffix REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status. AEC-Q100 is treated as not applicable because the verified temperature grade is commercial.

資料驗證日期: 2026-10-28 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

MAX133CMH+ MAX133CMH+ datasheet Maxim Integrated MAX133CMH+ 3.75 digit integrating ADC MAX133 20 samples per second ADC 44 pin MQFP integrating ADC MAX133CMH+ digital multimeter MAX133CMH+ data logger MAX133CMH+ weigh scale ADC MAX133CMH+ vs MAX134CMH+ MAX133CMH+ drop-in replacement MAX133CMH+ price where to buy MAX133CMH+ MAX133CMH+ pinout

相關元件與詞彙

Maxim Integrated MAX133CMH+ MAX133 MAX134 MAX134CMH+ MAX133CMH+D 3.75-digit ADC Integrating analog-to-digital converter ADC Voltage-to-digital conversion Digital multimeter Data logger Weigh scale Panel meter ±40,000-count internal resolution Guard digit Autozero Tare 50 ms conversion time 20 samples/s 44-pin MQFP QFP package family Gull-wing terminal RoHS Low-frequency process monitoring
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6