MAX307EPI+ - Dual 8:1 CMOS Analog Multiplexer | Maxim
MPN: MAX307EPI+ ✓ 啟用中MAX307EPI+ 概覽
An analog multiplexer is an interface IC that connects one of several analog inputs to a shared output. It reduces the number of signal paths required by a measurement, control, or data-acquisition system. In the product hierarchy, the MAX307EPI+ is a CMOS analog multiplexer, a type of analog switch and interface IC. The MAX306/MAX307 family provides precision signal routing for instrumentation, industrial control, data acquisition, communications, and test systems.
The MAX307EPI+ combines matched low on-resistance with fast switching. On-resistance below 100 ohms limits insertion loss when routing source signals, while matching within 5 ohms reduces channel-dependent gain variation. The specified 7-ohm maximum variation across the analog signal range helps preserve accuracy when the selected input voltage changes. Leakage is specified below 2.5 nA at 85 degrees Celsius, supporting low-level signal measurements.
Its monolithic CMOS construction uses a 44 V silicon-gate process, as described by the manufacturer for the MAX306/MAX307 family. The device provides two independent 8:1 sections rather than one 16:1 section. This arrangement allows simultaneous selection of two separate sources, making it useful for differential or paired-signal routing. The 28-pin PDIP format also supports conventional through-hole assembly and prototyping workflows.
Typical applications include multiplexed data acquisition, sensor signal routing, industrial measurement systems, communications interfaces, automated test equipment, and control systems requiring more than one analog source. Designers can use the two multiplexers to route a measurement input and a reference signal, select among multiple sensor outputs, or connect multiple analog channels to downstream conversion equipment.
The primary design consideration is signal integrity. Keep traces short, use a continuous ground reference, and place protection or filtering networks where their resistance and capacitance will not degrade accuracy. Verify that the source impedance, injected charge, leakage, and switching speed remain acceptable for the selected channel before committing the multiplexer to a precision measurement path.
This product page combines the manufacturer specifications, lifecycle information, archived pricing evidence, pin-compatible family alternatives, and practical routing guidance. It is intended to help engineers identify whether the MAX307EPI+ fits a multiplexed analog interface and how to evaluate its replacement options without changing the PCB footprint.
直接替換替代品,適用於 MAX307EPI+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX307EPI+ (相同外形與佔位) — 差異在於 Multiplexer Configuration, Process Technology.
MAX307CPI+
✅ 直接替換聯絡詢價
查看資料表 →MAX307EPI+ 規格
| Multiplexer Configuration | Dual 8:1 |
| Number of Circuits | 2 circuits |
| Number of Channels per Circuit | 8 channels |
| On-Resistance | Less than 100 ohm |
| On-Resistance Matching Between Channels | Within 5 ohm |
| On-Resistance Variation Across Analog Signal Range | 7 ohm maximum |
| Off-Leakage Current | Less than 2.5 nA at 85 degrees Celsius |
| Transition Time | Less than 250 ns |
| Process Technology | 44 V silicon-gate CMOS process |
| 封裝 | 28-pin PDIP |
| 安裝類型 | Through-hole |
| Device Type | Precision CMOS analog multiplexer |
| Manufacturer Lifecycle Designation | PRODUCTION |
MAX307EPI+ 28-pin pdip 腳位配置指南
MAX307EPI+(28-pin pdip 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX307EPI+.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX307EPI+ 適用於 6 應用s: Multiplexed Sensor Acquisition, Data Acquisition Systems, Industrial Control Signal Routing, Instrumentation Signal Conditioning, Communications Interface Routing, Automated Test Equipment.
Multiplexed Sensor Acquisition
The MAX307EPI+ fits sensor acquisition systems that must route several analog inputs to one measurement channel. Its two independent 8:1 sections can select a sensor and a related reference simultaneously. According to the manufacturer datasheet, on-resistance remains below 100 ohms, matching between channels is within 5 ohms, and on-resistance varies by no more than 7 ohms across the specified signal range. These properties reduce insertion loss and channel-dependent gain error. The less-than-250 ns transition time also supports measurement systems that need reasonably fast channel selection. Designers should still check the source impedance, settling time, protection-network capacitance, and acquisition timing before treating the multiplexer as an ideal zero-resistance switch.
推薦
Data Acquisition Systems
The MAX307EPI+ is appropriate for multichannel data-acquisition equipment where numerous analog inputs must share limited converter inputs. Two 8:1 sections provide 16 selections arranged as two independent groups, allowing measurement and control signals to be routed in parallel. The published on-resistance below 100 ohms, channel matching within 5 ohms, and low off leakage below 2.5 nA at 85 degrees Celsius help preserve low-level signal accuracy. Transition time below 250 ns provides a useful switching baseline, although converter acquisition and hold times may determine the practical sampling rate. Use short analog traces, a solid ground reference, and input filtering that does not materially increase source impedance or switching transients.
推薦
Industrial Control Signal Routing
The MAX307EPI+ can route multiple analog control or feedback signals in industrial control equipment. Its dual 8:1 organization allows one section to select a command and the other to select a feedback or monitor signal, reducing the number of dedicated analog input paths. The manufacturer specifies on-resistance below 100 ohms and channel matching within 5 ohms, which limits voltage-drop and gain differences between commands. Fast transition time below 250 ns supports prompt route changes when the controller changes operating state. For noisy industrial environments, retain the mux close to the controlled analog source, maintain an uninterrupted ground plane, and validate the complete signal path for offsets, charge injection, and settling behavior under the intended switching sequence.
推薦
Instrumentation Signal Conditioning
The MAX307EPI+ is useful in instrumentation that routes test points, excitation sources, or reference signals into a common conditioning chain. Low on-resistance below 100 ohms and channel matching within 5 ohms help maintain consistency when different inputs are selected. The 7-ohm maximum on-resistance variation across the specified analog range also limits voltage-dependent insertion loss. Because instrumentation accuracy can depend on leakage and transient behavior, confirm that off leakage below 2.5 nA at 85 degrees Celsius is adequate for the signal impedance and that switching transients settle before the next conversion. Locate the device near the protected input node when possible, and include the mux in the calibration and noise-characterization procedure.
推薦
Communications Interface Routing
The MAX307EPI+ can select low-level analog paths in communications equipment when a shared analog front end serves multiple sources or monitoring points. Its two independent multiplexers allow paired routing without duplicating the entire selection network, while sub-100-ohm on-resistance limits signal degradation at the selected channel. The 28-pin PDIP package is also convenient for through-hole prototypes and legacy interface assemblies. Signal integrity still requires attention because switching events can generate transient errors and the downstream receiver may be sensitive to impedance changes. Keep the selected traces compact, avoid sharing high-current return paths with sensitive inputs, and validate the maximum channel bandwidth against the specified analog signal range rather than relying only on the transition-time figure.
推薦
Automated Test Equipment
The MAX307EPI+ fits automated test systems that need to connect several DUT pins, references, or instrumentation outputs to shared analog measurement resources. The dual 8:1 configuration supports two simultaneous route selections, while the less-than-100-ohm on-resistance and within-5-ohm channel matching improve consistency between test channels. Transition time below 250 ns supports test systems with short command intervals, though cable capacitance, DUT loading, and measurement settling time can dominate total system performance. Keep the multiplexer near the test interface to minimize trace noise, use a low-inductance ground connection, and calibrate channel delay and residual error if the test limits are particularly tight. Verify the exact pin functions and control sequence against the package documentation.
推薦
推薦產品摘要
工程參考資料,適用於 MAX307EPI+ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX307CPI+ |
|---|---|---|
| Package | 28-pin PDIP | 28-pin PDIP |
| Brand | Maxim Integrated | Maxim Integrated |
| Multiplexer Configuration | Dual 8:1 | Dual 8:1 |
| Number of Circuits | 2 circuits | 2 circuits |
| On-Resistance | Less than 100 ohm | Less than 100 ohm |
| Channel Matching | Within 5 ohm | Within 5 ohm |
| On-Resistance Variation | 7 ohm maximum | 7 ohm maximum |
| Off-Leakage Current | Less than 2.5 nA at 85 degrees Celsius | Less than 2.5 nA at 85 degrees Celsius |
| Transition Time | Less than 250 ns | Less than 250 ns |
| Process Technology | 44 V silicon-gate CMOS process | 44 V silicon-gate CMOS process |
主要差異化特點
- Two independent analog selectors in one package (對比MAX307CPI+)
- Matched low on-resistance (對比MAX307CPI+)
- Temperature-grade distinction within the same footprint (對比MAX307CPI+)
設計說明
Treat the MAX307EPI+ as a precision analog routing element rather than an ideal switch. The manufacturer specifies on-resistance below 100 ohms, channel matching within 5 ohms, and no more than 7 ohms of variation across the specified signal range. Check whether the resulting insertion loss, gain spread, and source loading remain acceptable for the selected source impedance. Account for amplifier input bias current, protection-diode leakage, and downstream capacitance, and verify settling time in the complete acquisition chain.
Place the 28-pin PDIP close to the analog source and destination it serves. Keep selected-channel traces short and continuous, use a low-impedance ground plane, and avoid routing sensitive analog lines beside high-current switching nodes. A multiplexer cannot recover signal energy lost in long traces or contaminated references. For precision measurements, establish the analog ground and digital return-current arrangement before finalizing the layout, then test channel-to-channel error under the actual switching sequence.
Do not select a substitute from package shape alone. A valid drop-in replacement must preserve all 28 pin functions, the two independent 8:1 control logic, supply requirements, logic thresholds, analog limits, and timing. The MAX307CPI+ is the identified same-package family candidate, but its temperature grade differs from the E grade. Confirm the exact suffix and operating limits in the manufacturer ordering information before releasing the substitution to production.
合規資訊
The lead-free-plus marking identifies the ordering form, but no explicit RoHS, REACH, halogen-free, or conflict-minerals declaration is stated on the product pages used for this record.