MAX3097EESE+ - Triple 32Mbps RS-422/RS-485 Receiver | Analog Devices
MPN: MAX3097EESE+ ✓ 啟用中MAX3097EESE+ 概覽
A line receiver is an interface circuit that converts low-amplitude differential signals into a digital logic-level output. RS-422 and RS-485 are balanced serial-interface standards used to transmit data reliably over cables and through electrically noisy environments. The MAX3097EESE+ belongs to the receiver and interface-IC hierarchy, combining differential signaling, fault indication, and transient protection in one device.
Key features include three high-speed receivers, support for both RS-422 and RS-485 signaling, ±15 kV ESD protection, and operation up to 32 Mbps. The fault-detection circuitry indicates when a receiver input is not in a valid state, allowing system software or hardware monitoring logic to identify wiring faults, idle conditions, or abnormal bus states. The 16-pin NSOIC package supports conventional surface-mount PCB assembly.
The MAX3097E family is intended for industrial data links, factory equipment, communications interfaces, and other systems that use balanced differential signaling. Its three-channel architecture reduces component count when several receiver channels are required on one board. The ±15 kV ESD rating is particularly relevant to externally connected communication lines, where static discharge and cable-borne transients can damage interface circuitry.
Designers should verify the receiver’s fault-status logic, supply sequencing, input termination, and cable configuration against the manufacturer datasheet before production use. Differential receiver inputs should be routed as a matched pair, with appropriate grounding and protection implemented according to the system’s cable environment. The receiver is not a transmitter, so a separate RS-485 driver is required when a design needs bidirectional bus communication.
This product page consolidates verified manufacturer and distributor information, pricing references, package details, and application guidance for engineers evaluating the MAX3097EESE+. It is intended as a technical buying and design reference rather than a substitute for the complete manufacturer datasheet.
直接替換替代品,適用於 MAX3097EESE+ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX3097EESE+ (相同外形與佔位) — 差異在於 Maximum Data Rate, Product Type, Supported Standards.
此產品無可直接替換的替代品。
申請替代品MAX3097EESE+ 規格
| Receiver Configuration | Triple receiver |
| Supported Standards | RS-422 and RS-485 |
| Maximum Data Rate | 32 Mbps |
| Supply Voltage Range | 3 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| ESD Protection | ±15 kV |
| Fault Detection | Yes |
| Fault Outputs | Active push-pull fault-status outputs |
| Receiver Input Type | Differential RS-422/RS-485 input |
| Number of Channels | 3 |
| 工作溫度 | -40 C to +85 C |
| Package Type | 16-pin NSOIC |
| Package Technology | CMOS |
| 安裝類型 | Surface mount |
| Product Type | RS-422/RS-485 interface receiver |
| Transient Protection | ±15 kV ESD-protected inputs |
| Supply Compatibility | 3 V/5 V operation |
MAX3097EESE+ cmos 腳位配置指南
MAX3097EESE+(cmos 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX3097EESE+.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX3097EESE+ 適用於 6 應用s: Industrial RS-485 Communication Interfaces, Factory Automation Data Links, RS-422 Point-to-Point Communications, Telemetry and Remote Monitoring Equipment, Communication Circuit Cards, External Cable-Connected Control Systems.
Industrial RS-485 Communication Interfaces
The MAX3097EESE+ fits industrial equipment that needs several balanced receive channels on one board. Its three RS-422/RS-485 receivers reduce package count, while the 32 Mbps capability supports high-speed data transfer. The ±15 kV ESD protection is useful when the receiver channels connect to external equipment or long cables. Designers should use differential routing, controlled grounding, and validated surge protection around the communication interface.
推薦
Factory Automation Data Links
Factory automation systems commonly distribute machine data over balanced RS-485 networks. The MAX3097EESE+ provides three receive channels, 32 Mbps operation, and fault-status outputs that can help a controller monitor invalid bus states. It is appropriate for equipment interfaces where diagnostic information is useful, provided the cable topology, termination, and grounding are designed according to the communications standard.
推薦
RS-422 Point-to-Point Communications
The device can serve as the receiving element in RS-422 point-to-point links requiring multiple differential channels. Its three-receiver architecture is useful for control, status, or supervisory signals, while the 32 Mbps specification supports faster signaling than many legacy industrial interfaces. The design must confirm input thresholds, timing, termination, and fault behavior against the complete manufacturer datasheet.
推薦
Telemetry and Remote Monitoring Equipment
Telemetry systems benefit from the MAX3097EESE+ when several external communication lines must be monitored. The active push-pull fault outputs provide a way to report invalid receiver states to supervisory logic, and the ESD protection helps withstand static discharge at exposed interfaces. In battery- or field-powered equipment, engineers should still verify supply-current and power-budget requirements from the manufacturer documentation.
推薦
Communication Circuit Cards
The 16-pin NSOIC package is well suited to compact communication interface boards that need standardized surface-mount assembly. Three receive channels can support separate command, telemetry, or status lines, while fault indicators allow health monitoring without relying only on decoded data validity. Board layout should preserve differential-pair geometry and provide adequate return-path continuity through the interface section.
推薦
External Cable-Connected Control Systems
The MAX3097EESE+ is a practical candidate for control systems whose cable-connected inputs can encounter electrostatic discharge. Its ±15 kV ESD rating provides a defined input-protection target, and the operating range of -40 C to +85 C supports many industrial environments. The rating should be treated as a component-level specification, not a guarantee of immunity for the entire finished product.
推薦
推薦產品摘要
工程參考資料,適用於 MAX3097EESE+ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Device Type | Triple RS-422/RS-485 receiver |
| Package | 16-pin NSOIC |
| Brand | Analog Devices |
| Maximum Data Rate | 32 Mbps |
| Supply Voltage | 3 V to 5.5 V |
| ESD Protection | ±15 kV |
| Operating Temperature | -40 C to +85 C |
| Fault Detection | Yes |
| Number of Receivers | 3 |
主要差異化特點
- Three receiver channels in one package (對比ADM485ARZ)
- Dedicated fault-status outputs (對比ADM485ARZ)
- High-speed differential reception (對比ADM485ARZ)
設計說明
Route each differential receiver input as a matched pair and maintain continuous ground/reference paths beneath the pair. Avoid adding long stubs, test pads, or unrelated high-current traces adjacent to the communication nets. The MAX3097EESE+ supports up to 32 Mbps according to the verified data, so edge-rate harmonics can be significant even when the cable appears electrically short.
Do not treat the MAX3097EESE+ as an RS-485 transmitter. It contains three receivers and fault-detection outputs, so a bidirectional link still needs a separate driver. Confirm the receiver’s valid-idle and fault-status behavior in the manufacturer datasheet before using those outputs for safety-critical monitoring, since the supplied data does not provide the individual logic thresholds or pin assignments.
Place ESD-protection and interface components close to the external connector, with the protected trace arranged so surge current has a short path to the board ground or protection network. Keep the receiver’s supply decoupling close to its supply pins and separate external cable routing from sensitive digital circuitry. These practices help preserve the stated ±15 kV component ESD capability without assuming it guarantees complete system immunity.
合規資訊
The supplied verified data does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. Compliance fields are therefore left unknown rather than inferred.