MAX3384ECWN+T - 250kbps RS-232 Transceiver | Analog Devices
MPN: MAX3384ECWN+T ✓ 啟用中MAX3384ECWN+T 概覽
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 levels and converts incoming RS-232 signals back into digital logic levels. It belongs to the interface IC hierarchy, where the transceiver performs the physical signal conversion between a host controller or UART and an RS-232 port. This integration reduces the number of discrete line-driver and receiver components required at the board level.
The MAX3384ECWN+T operates from 3.0V to 5.5V, supports data rates up to 250kbps, and provides 15kV ESD protection. The Analog Devices manufacturer page specifies that all transmitter outputs and receiver inputs are protected. Its 18-pin SOIC package supports conventional surface-mount assembly and is suitable for industrial-control, communications, instrumentation, and embedded-system interfaces operating across 0°C to 70°C.
The device uses two transmitters and two receivers, allowing two serial channels or full-duplex operation depending on how the interface pins are connected. Because it is a true RS-232 transceiver rather than a differential RS-422 or RS-485 device, its voltage levels and application role are not interchangeable with those bus standards. The 250kbps maximum data rate is suitable for legacy serial equipment, control consoles, POS systems, and industrial peripherals that use EIA/TIA-232.
Typical applications include point-of-sale terminals, security and access-control equipment, test and measurement instruments, industrial controllers, and service-console interfaces. The integrated ESD protection is particularly valuable where an exposed serial cable can introduce electrostatic discharge into a control board. The 3.0V minimum supply voltage also helps the device operate alongside modern low-voltage digital systems without requiring a dedicated 5V-only interface rail.
PCB design should preserve the datasheet-recommended supply and bypass-capacitor placement while keeping unprotected external connector wiring away from sensitive traces. Confirm the RS-232 signal levels and data direction in the system schematic, and verify that the 250kbps rating covers the required baud rate with suitable margin. Use the manufacturer pin-description table and pinout drawing when assigning connector and logic-net connections.
This page combines the manufacturer interface description, distributor package information, replacement guidance, parameter comparisons, and practical PCB considerations in a form intended to accelerate component selection and hardware design.
直接替換替代品,適用於 MAX3384ECWN+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
MAX3384ECWN
✅ 直接替換📋 參考替代品(不在目錄中)
MAX3384ECWN-T
✅ 直接替換📋 參考替代品(不在目錄中)
MAX3384ECWN+T 規格
| Transceiver Configuration | 2/2 |
| Interface Standard | RS-232 |
| Supported Communications Standards | EIA/TIA-232 and V.28/V.24 |
| Supply Voltage Range | 3.0V to 5.5V |
| Maximum Data Rate | 250kbps |
| ESD Protection | 15kV |
| Transmitter Count | 2 |
| Receiver Count | 2 |
| 封裝 | 18-pin SOIC |
| Device Type | RS-232 transceiver |
| 工作溫度 | 0°C to 70°C |
| 安裝類型 | Surface mount |
| Power Consumption | Low-power operation |
MAX3384ECWN+T 18-pin soic 腳位配置指南
MAX3384ECWN+T(18-pin soic 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX3384ECWN+T.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX3384ECWN+T 適用於 6 應用s: Point-of-Sale Terminal Interfaces, Industrial Control Serial Consoles, Instrumentation and Test Equipment, Access-Control and Security Systems, Embedded Data Acquisition Modules, Service and Configuration Interfaces.
Point-of-Sale Terminal Interfaces
The MAX3384ECWN+T is well suited to legacy point-of-sale equipment that uses RS-232 links for receipt printers, customer displays, or service terminals. Its two transmitters and two receivers provide two full RS-232 channels in one 18-pin SOIC device, while operation from 3.0V to 5.5V simplifies interface with embedded logic running below 5V. The 250kbps data-rate capability comfortably covers common serial peripherals, and 15kV ESD protection adds useful defense where the connector may be exposed to user-accessible cables. Designers should still verify signal direction, connector pin assignment, and charge-pump capacitor placement in the manufacturer application circuit.
推薦
Industrial Control Serial Consoles
The MAX3384ECWN+T can connect a controller or service console through an RS-232 port when an EIA/TIA-232 physical layer is required. Two transmitters and two receivers support paired channels or configurable directional links, while the 3.0V to 5.5V operating range permits use beside both 3.3V and 5V system rails. Its low-power design is useful in embedded equipment, and the 15kV ESD protection on transmitter outputs and receiver inputs helps reduce vulnerability to discharge events entering through a service connector. For production use, verify that the 0°C to 70°C operating range satisfies the enclosure's thermal environment.
推薦
Instrumentation and Test Equipment
The MAX3384ECWN+T is appropriate for test and measurement equipment that retains an RS-232 control or data port. The integrated 2/2 transceiver arrangement reduces the board area and component count compared with four discrete line-interface functions, while its low-power operation supports compact instruments. A maximum data rate of 250kbps is suitable for configuration transfers, command channels, and legacy instrument protocols operating below that limit. Because lab and field instruments may have externally accessible connectors, the 15kV ESD protection on all transmitter outputs and receiver inputs is an important implementation advantage. Retain the manufacturer-recommended bypass and charge-pump network in the final layout.
推薦
Access-Control and Security Systems
The MAX3384ECWN+T fits access-control readers, security panels, and configuration equipment that use RS-232 for command exchange or event reporting. Its two transmitters and two receivers permit two serial links within a single 18-pin SOIC footprint, and the 3.0V to 5.5V supply range allows operation alongside embedded control electronics. The 250kbps maximum data rate accommodates common security-system command protocols, while 15kV ESD protection strengthens a connector-facing interface that may receive cable-borne transients. Layout engineers should keep the RS-232 traces away from sensitive analog or high-speed digital paths and verify that the board's grounding arrangement satisfies the interface application guidance.
推薦
Embedded Data Acquisition Modules
The MAX3384ECWN+T can provide a legacy PC or controller communication channel in an embedded data-acquisition module. Two transmitters and two receivers support simultaneous control and status paths, and the 250kbps rate is adequate for many short command packets and moderate telemetry streams. Its 18-pin SOIC package makes it practical for compact mixed-signal boards, while low-power operation helps limit system consumption. The part is especially attractive when replacing separate RS-232 driver and receiver ICs without moving to an entirely different bus architecture. Confirm the host-side UART logic levels, use the manufacturer's specified charge-pump capacitors, and confirm the required operating temperature before release.
推薦
Service and Configuration Interfaces
The MAX3384ECWN+T is useful in configuration ports for industrial appliances, diagnostic tools, and remotely managed equipment that still uses RS-232. A single integrated device provides two transmit channels and two receive channels, allowing separate command and response wiring where both directions are needed. Its operation from 3.0V to 5.5V supports common embedded supply levels, and 15kV ESD protection is valuable when service personnel connect an external cable. The 250kbps capability provides adequate margin for many configuration protocols, but the complete system must remain below this limit after accounting for framing, baud-rate tolerance, and cable loading. Follow the manufacturer reference layout for bypass and charge-pump components.
推薦
推薦產品摘要
工程參考資料,適用於 MAX3384ECWN+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX3384ECWN | MAX3384ECWN-T |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 18-pin SOIC | 18-pin SOIC | 18-pin SOIC |
| Transceiver Configuration | 2/2 | 2/2 | 2/2 |
| Interface Standard | RS-232 | RS-232 | RS-232 |
| Supply Voltage Range | 3.0V to 5.5V | 3.0V to 5.5V | 3.0V to 5.5V |
| Maximum Data Rate | 250kbps | 250kbps | 250kbps |
| ESD Protection | 15kV | 15kV | 15kV |
| Low-Power Operation | Yes | Yes | Yes |
| Number of Pins | 18 pins | 18 pins | 18 pins |
主要差異化特點
- Four RS-232 line functions in one package (對比MAX3384ECWN)
- Low-voltage compatibility for modern embedded systems (對比MAX3384ECWN-T)
- Connector-facing ESD resilience (對比MAX3384ECWN)
設計說明
Place the MAX3384ECWN+T bypass capacitors and charge-pump capacitors close to their associated device pins, following the component placement and trace geometry shown in the MAX3384E manufacturer application circuit. Keep the RS-232 driver and receiver traces away from clocks, precision analog inputs, and high-speed switching nodes. A short ground return from the interface device to the board's main ground plane helps establish predictable return paths and reduce coupling into adjacent circuitry.
Do not substitute the MAX3384ECWN+T for an RS-422 or RS-485 interface on the assumption that all serial transceivers are interchangeable. The MAX3384E family creates true RS-232 levels, while differential interfaces use different signaling, grounding, termination, and fault-recovery requirements. Also verify that the selected ordering code retains the 18-pin SOIC footprint and the required temperature and packing configuration before approving a substitution.
Treat the connector side of the transceiver as an ESD-sensitive area even though the device provides 15kV protection on all transmitter outputs and receiver inputs. Route exposed cable-side traces away from board edges and high-energy switching paths where practical, provide a solid ground reference, and keep unprotected copper minimal near the connector. Protection ratings reduce vulnerability but do not replace correct mechanical design, cable management, and system-level grounding.
合規資訊
The orderable code includes a + suffix, but no explicit RoHS, REACH, halogen-free, or conflict-minerals declaration is present. Compliance documents should be confirmed for the exact production ordering code.