MAX71071+T - Dual 24-Bit Isolated ADC | Analog Devices
MPN: MAX71071+T ✓ 啟用中MAX71071+T 概覽
An isolated ADC is an analog-to-digital converter whose measurement side is electrically separated from the control and processing side. This isolation limits the transfer of unwanted voltage and current between a high-voltage or high-current measurement environment and the host electronics. Within the signal-chain hierarchy, the MAX71071+T is a data-acquisition IC, an isolated ADC, and ultimately a metrology measurement component.
The MAX71071+T provides two measurement inputs, 24-bit resolution, and simultaneous isolation through a pulse transformer. The pulse transformer carries the isolated data, clock, and power path, reducing the need for separate isolation components in the measurement subsystem. The host retains responsibility for control commands and the associated power supplied toward the measurement interface.
This architecture is intended to measure current and voltage while maintaining an isolation barrier between the sensed quantities and the host. The exact input ranges, accuracy figures, sampling rate, power requirements, channel multiplexing arrangement, and timing characteristics should be confirmed against the relevant MAX71071 manufacturer documentation before setting the analog front end and system timing.
Typical uses include isolated current monitoring, isolated voltage measurement, industrial metering equipment, power-system instrumentation, and other metrology systems that pair the converter with a compatible MAX71xxx host. The isolated interface is particularly useful when the measured circuit and the controller must remain galvanically separated.
Designers should begin with the host-interface requirements, supported input ranges, and isolation ratings. Transformer-based isolation imposes timing and layout considerations around the measurement side, while host-side routing must preserve clock and data signal integrity. Component values, filtering, grounding, and creepage requirements should be derived from the application voltage, current, bandwidth, and safety environment.
This product page combines the manufacturer product information, distributor listings, family relationships, and practical selection guidance to clarify where the MAX71071+T belongs in an isolated metrology design. It also distinguishes documented functions from parameters that require engineering confirmation before layout release.
直接替換替代品,適用於 MAX71071+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX71071+T (相同外形與佔位) — 差異在於 Host Compatibility, Number of Input Channels, Resolution.
MAX71071+
✅ 直接替換聯絡詢價
查看資料表 →MAX71071H
✅ 直接替換📋 參考替代品(不在目錄中)
MAX71071+T 最大額定值與電氣特性
| ADC Type | Dual-channel isolated analog-to-digital converter |
| 解析度 | 24 bit |
| Number of Input Channels | 2 channels |
| Input Functions | Current measurement and voltage measurement |
| Isolation Interface | Pulse-transformer isolated data, clock, and power path |
| Host Compatibility | Compatible MAX71xxx host |
| Host Control Role | Control, command, and power provided through the MAX71xxx host |
| 封裝 | 10-uMAX/uSOP |
| 安裝類型 | Surface mount |
MAX71071+T 10-umax/usop 腳位配置指南
MAX71071+T(10-umax/usop 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: MAX71071+T.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX71071+T 適用於 6 應用s: Isolated Current Monitoring, Isolated Voltage Measurement, Power-System Instrumentation, Industrial Metering Equipment, Remote Sensor Interfaces, Precision Energy-Measuring Systems.
Isolated Current Monitoring
The MAX71071+T is appropriate for isolated current monitoring because its two 24-bit channels support current and voltage measurement while the pulse transformer provides an isolated data, clock, and power path to a compatible MAX71xxx host. Place the converter at the measurement side of the isolation barrier and route the host interface through the manufacturer-defined topology. This architecture can reduce the need for separate isolation components. Confirm the supported current range, gain path, conversion timing, and channel multiplexing before assigning the current-shunt signal. Verify isolation capacitance, creepage, filtering, and grounding against the conductor’s potential and the required safety category.
推薦
Isolated Voltage Measurement
The MAX71071+T can support isolated voltage measurement in metrology equipment that must retain a separation between the sensed voltage and the host controller. Its two measurement channels and 24-bit resolution suit precision measurement systems, while the pulse-transformer architecture transfers isolated data, clock, and power without requiring a separate isolation link for each function. The input conditioning network should present a signal within the converter’s documented range and bandwidth. Establish divider ratios, anti-alias filtering, input impedance, and reference accuracy from the application specification before schematic release.
推薦
Power-System Instrumentation
The MAX71071+T fits power-system instrumentation where current and voltage must be measured in an isolated domain and communicated to a supervising controller. Its dual-channel, 24-bit architecture supports coordinated metrology, while the pulse-transformer isolation path provides communication and isolated power through one defined mechanism. A compatible MAX71xxx host can handle command, control, and power coordination. The circuit must be designed around the exact input ranges, sampling behavior, timing, and isolation rating of the selected device. High-voltage layout should also observe the required separation distance and isolation-component rules.
推薦
Industrial Metering Equipment
The MAX71071+T is useful in industrial metering equipment that measures two electrical quantities and must communicate the results through an isolated interface. Its 24-bit dual-channel format provides a clear path for current plus voltage acquisition, and its integrated pulse-transformer isolation architecture reduces the number of separate isolation elements needed around the measurement subsystem. Pair the converter with a MAX71xxx host that supports the required commands and data format. Select input dividers or shunts so the full-scale signal remains within the documented operating limits, and validate accuracy over the required temperature and load range.
推薦
Remote Sensor Interfaces
The MAX71071+T can serve as the isolated measurement interface for remote sensor systems in which the sensed current or voltage must be transferred across a galvanic boundary. The pulse-transformer path carries data, clock, and power between the converter and a compatible MAX71xxx host, supporting an isolated subsystem architecture. This is useful when the sensor is referenced to a noisy, high-energy, or inaccessible circuit. The remote node still needs correct input conditioning and suitable creepage and clearance. Confirm the supported host timing, measurement bandwidth, and power-transfer requirements before treating the remote interface as a standardized sensor link.
推薦
Precision Energy-Measuring Systems
The MAX71071+T is appropriate for precision energy-measuring systems that combine isolated voltage and current acquisition with a digital metrology host. Its two channels and 24-bit resolution support high-resolution measurement, while the pulse-transformer isolation architecture maintains the separation between the measured power circuit and the processing electronics. A compatible MAX71xxx host supplies control and command functions. System accuracy will depend on the selected shunt, voltage divider, input filtering, reference behavior, calibration method, and synchronization requirements. Validate those parameters together because converter resolution alone does not define end-to-end metering accuracy.
推薦
推薦產品摘要
工程參考資料,適用於 MAX71071+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX71071 | MAX71071H | MAX71071 | MAX71071+ |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Silergy | Silergy |
| Package | 10-uMAX/uSOP | 10-uMAX/uSOP | 10-uMAX/uSOP | 10-uMAX/uSOP | 10-uMAX/uSOP |
| ADC Resolution | 24 bit | 24 bit | 24 bit | 24 bit | 24 bit |
| Number of Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Measurement Functions | Current and voltage measurement | Current and voltage measurement | Current and voltage measurement | Current and voltage measurement | Current and voltage measurement |
| Isolation Architecture | Pulse transformer for data, clock, and power | Pulse transformer for data, clock, and power | Pulse transformer for data, clock, and power | Pulse transformer for data, clock, and power | Pulse transformer for data, clock, and power |
| Host Interface | Compatible MAX71xxx host | Compatible MAX71xxx host | Compatible MAX71xxx host | Compatible MAX71xxx host | Compatible MAX71xxx host |
| Ordering Configuration | MAX71071+T tape-and-reel configuration | Base ordering code | H-grade ordering code | Silergy base ordering code | Silergy plus ordering code |
主要差異化特點
- Two-channel measurement in one isolated converter (對比MAX71071H)
- Integrated pulse-transformer isolation path (對比Silergy MAX71071+)
- Current-and-voltage metrology positioning (對比Analog Devices MAX71071)
設計說明
Keep the measurement-side analog traces short, symmetrical, and isolated from the host-side digital interface. Route the pulse-transformer data and clock paths according to the manufacturer reference layout, with continuous return paths and no unintended crossings between the two isolation domains. Confirm creepage, clearance, isolation capacitance, and common-mode limits against the maximum working voltage before board fabrication.
Design the analog input network for the selected current or voltage range before assigning filtering values. Include the required shunt or divider, input protection, anti-alias filter, and grounding strategy, then verify channel-to-channel timing and settling. The 24-bit conversion resolution does not guarantee equivalent system accuracy; resistor tolerances, reference error, noise, and measurement bandwidth remain part of the end-to-end error budget.
Do not substitute a family member solely from the channel count and resolution. Check the ordering table, package geometry, pulse-transformer arrangement, MAX71xxx host protocol, accuracy grade, input range, conversion timing, and lifecycle status. Silergy and Analog Devices listings may share the headline architecture, but production equivalence still requires board-level and timing validation before changing the approved BOM.
Place input-conditioning components close to the converter pins and maintain a clearly defined isolation barrier across the board. Avoid placing high-voltage copper, test points, or mechanical fasteners in the separation region unless the applicable clearance rules permit them. Use the manufacturer’s isolation layout and component placement as the baseline, then verify the finished assembly for unintended conductive bridges between measurement and host domains.
合規資訊
Compliance declarations were not identified in the manufacturer or distributor information used for this product. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status for the exact ordering code before release.