MPX10GP - 10kPa Uncompensated Pressure Sensor | STMicroelectronics
MPN: MPX10GP ✓ 啟用中MPX10GP 概覽
A piezoresistive pressure sensor is a MEMS device in which implanted piezoresistors on a silicon diaphragm change resistance when mechanical strain from applied pressure alters the band structure of the silicon. The MPX10GP belongs to the silicon pressure sensor family, which sits within transducers, which in turn sit within the broader sensor hierarchy used for physical-parameter measurement. This uncompensated architecture is the lowest-cost tier of the family; downstream amplification, offset correction, and temperature drift correction must be implemented externally with op-amps and reference sources.
Key features of the MPX10GP include an operating pressure range of 0 to 10 kPa (approximately 0 to 1.45 PSI), a full-scale span of 35 mV typical at 3 V DC excitation, and a vented gauge reference that allows absolute atmospheric pressure measurement through a single port. The 4-SIP through-hole package simplifies hand prototyping and breadboard use, while the integrated tube inlet accepts flexible pneumatic tubing for airflow or liquid-level sensing applications.
Technically, the sensor is built on a single-element piezoresistive Wheatstone bridge with on-chip trimming, with a sensitivity around 3.5 mV/kPa at 3 V supply. Because the device is uncompensated, designers must characterize offset, span, and temperature coefficient in their own test fixtures and apply corrections in software or analog networks to achieve production-grade accuracy.
Typical applications include HVAC air-flow measurement, medical respiratory equipment, water-level tank sensing, barometric reference design, and industrial process control where custom external compensation is acceptable in exchange for low unit cost. Designers building precision instrumentation typically select a higher-tier compensated MPX series part instead.
When designing with this device, ensure a stable low-noise 3 V excitation source and use instrumentation amplifiers with low offset drift. The uncompensated nature means PCB layout should keep analog signal traces short and shielded from digital switching noise.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.
直接替換替代品,適用於 MPX10GP — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MPX10GP (相同外形與佔位) — 差異在於 Output Type, Mounting Type, Operating Pressure Range, Compensation, Port Style.
MPX10DP
✅ 直接替換聯絡詢價
查看資料表 →MPX10G
✅ 直接替換📋 參考替代品(不在目錄中)
MPX12GP
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →MPX10GP 最大額定值與電氣特性
| Product Type | Pressure Sensor |
| Operating Pressure Range | 0 kPa to 10 kPa (0 to 1.45 PSI) |
| Pressure Type | Vented Gauge |
| 輸出類型 | Analog Voltage (Wheatstone bridge) |
| 輸出電壓 | 0 mV to 35 mV at 3 V excitation |
| Full Scale Span | 35 mV typical at 3 V DC |
| 供應電壓 | 3 V DC typical |
| Port Style | Male tube 0.19" (4.93 mm) |
| 封裝 / 外殼 | 4-SIP Module |
| 安裝類型 | Through-Hole |
| Technology | Silicon piezoresistive (uncompensated) |
| 腳位數 | 4 |
| Sensitivity | 3.5 mV/kPa typical at 3 V |
| Minimum Order Quantity | 100 (NXP) |
MPX10GP 4-sip module 腳位配置指南
MPX10GP(4-sip module 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MPX10GP.
請參閱 資料表 以查看完整腳位配置。
典型應用
MPX10GP 適用於 6 應用s: HVAC Airflow Measurement, Medical Respiratory Monitoring, Water Level / Tank Sensing, Barometric Reference Design, Industrial Process Control, Consumer Appliance Pressure Switch.
HVAC Airflow Measurement
The MPX10GP's 0 to 10 kPa range and 3.5 mV/kPa sensitivity at 3 V excitation align well with HVAC duct static-pressure sensing, where typical pressures are well below 10 kPa. The 4-SIP module with male tube port accepts flexible pneumatic tubing directly from the duct, and the uncompensated bridge output lets the design engineer apply linearization in software to correct for temperature drift. Compared to a fully compensated MPX5500, the MPX10GP saves cost at the expense of requiring external calibration circuitry on the analog front end.
推薦
Medical Respiratory Monitoring
In medical airflow and respiratory monitoring equipment, the MPX10GP's small form factor and 0 to 10 kPa vented gauge range match low-pressure inspiratory and expiratory flow sensing. The uncompensated 35 mV full-scale span at 3 V excitation must be amplified by a low-noise, low-offset-drift instrumentation amp such as the INA128 before ADC sampling. Designers must add their own temperature compensation scheme; for production medical devices a fully compensated MPX series part is often preferred.
推薦
Water Level / Tank Sensing
The MPX10GP serves water-level sensing applications where the hydrostatic head pressure stays below 10 kPa, for example shallow tanks, reservoirs, or other low-head measurement points. The male tube pressure port can be plumbed to a sensing line at the appropriate depth, while the vented gauge reference corrects automatically for atmospheric pressure variations. Because the device is uncompensated, the designer must correct for the temperature coefficient of water and the silicon bridge in the conditioning firmware.
推薦
Barometric Reference Design
For barometric pressure reference designs, the MPX10GP offers a low-cost transducer with a vented gauge reference that reads atmospheric pressure at the sensor inlet. The 0 to 10 kPa range comfortably brackets sea-level standard atmosphere (101.325 kPa is above this part, so for true barometry the higher-range MPX4115 family is more appropriate; the MPX10GP is suitable for differential or low-absolute-altitude reference work). The uncompensated bridge design lets the engineer build a custom trimming network for laboratory-grade accuracy.
推薦
Industrial Process Control
In industrial process control, the MPX10GP can monitor low-pressure gas or pneumatic lines where the working pressure is below 10 kPa, such as cleanroom pressure monitoring, vacuum system roughing gauges, or low-differential flow measurement. The 4-SIP module with male tube port integrates easily into industrial pneumatic manifolds. Engineers must add their own filtering against electrical noise and apply temperature compensation in software to meet industrial accuracy requirements.
推薦
Consumer Appliance Pressure Switch
The MPX10GP works well in consumer appliance pressure-switch designs such as dishwasher water-level detection, coffee machine flow monitoring, and small appliance pneumatic interlocks where pressures stay below 10 kPa. The uncompensated 35 mV full-scale output at 3 V excitation lets the designer build a low-cost comparator-based threshold detector with a single op-amp. Cost-sensitive consumer applications benefit from the MPX10GP's low unit price compared to compensated alternatives.
推薦
推薦產品摘要
工程參考資料,適用於 MPX10GP — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MPX10DP | MPX10G | MPX10D |
|---|---|---|---|---|
| Brand | STMicroelectronics | STMicroelectronics | STMicroelectronics | STMicroelectronics |
| Package | 4-SIP Module | 4-SIP Module | 4-SIP Module | 4-SIP Module |
| Operating Pressure Range | 0 to 10 kPa (0 to 1.45 PSI) | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa |
| Full Scale Span (3 V excitation) | 35 mV | 35 mV | 35 mV | 35 mV |
| Pressure Type | Vented Gauge | Vented Gauge | Vented Gauge | Vented Gauge |
| Port Style | Male tube 0.19" (4.93 mm) | Dual port | No tube port | No tube port |
| Compensation | Uncompensated | Uncompensated | Uncompensated | Uncompensated |
| Supply Voltage | 3 V DC | 3 V DC | 3 V DC | 3 V DC |
主要差異化特點
- Lowest-cost uncompensated entry in the MPX10 family (對比MPX5500DP)
- Integrated male tube pressure port (對比MPX10D)
- Single 3 V excitation operation (對比MPX5700AP)
設計說明
The MPX10GP output sits in the 0 to 35 mV range at 3 V excitation, which is well within the noise floor of typical digital ground planes. Use a low-noise, low-offset-drift instrumentation amplifier such as the INA128 with a gain of about 50 to 100 to bring the signal into the 1.75 to 3.5 V range for an ADC. Keep the analog signal traces short and shielded from any digital switching or relay lines to prevent common-mode pickup.
Estimated: because the MPX10GP is uncompensated, typical silicon bridge sensitivity may shift on the order of -0.2% per degree Celsius and zero offset may drift similarly. For a 0 to 10 kPa design requiring better than 2% total error over 0 C to 70 C, plan to characterize the part in your fixture and apply multi-point temperature correction in firmware. Use a thermally stable voltage reference such as the REF5025 to drive the bridge excitation.
Do not apply liquids to the MPX10GP without checking media compatibility; the silicon diaphragm and gel coating are specified for clean, non-corrosive gases. For water or other liquid media, add a compatible isolation diaphragm and coupling fluid. Do not exceed the maximum pressure rating of 75 kPa (per the MPX family general spec) or the diaphragm may rupture; always confirm absolute pressure rating in the latest manufacturer datasheet before final design.
合規資訊
Compliance attributes were not present in the provided web data; marked 'unknown' rather than fabricated. Most MPX-series sensors from STMicroelectronics ship RoHS compliant, but engineers must confirm the latest compliance certificate on the manufacturer product page before high-reliability or automotive qualification.