OPA512SM - ±50V, 15A High-Power Op Amp | Texas Instruments
MPN: OPA512SM ✓ 啟用中OPA512SM 概覽
An operational amplifier is an amplifier IC that increases the voltage difference between its differential inputs while using negative feedback to establish gain and output impedance. Power operational amplifiers form the high-current branch of the operational-amplifier hierarchy and can drive low-impedance loads that exceed the current capability of ordinary precision op amps. The OPA512SM combines this general amplifier function with high-power output capability and internal voltage-current limit protection.
The principal features are a 15 A peak output current, wide ±50 V supply operation, Class A/B output-stage operation, and voltage-current limit protection. The OPA512SM uses an 8-terminal TO-3-8 package, providing a robust mechanical format for high-power analog circuits. Its multi-chip implementation is also identified as a hybrid circuit device, distinguishing it from monolithic power amplifiers intended for similar output-current levels.
The manufacturer specifications for the OPA512 family are based on a nominal ±40 V operating condition. The OPA512SM extends the maximum total supply-voltage limit to 100 V, compared with the 90 V limit stated for the base OPA512. This additional headroom is important when designing high-voltage power stages because output swing, current limiting, and safe operation must all remain compatible with the actual supply rails.
Typical uses include audio power-amplifier output stages, laboratory current sources, motor and actuator drivers, ultrasonic-driver circuits, and industrial power-control systems. The 15 A peak current is valuable for low-impedance loads, while the broad supply range supports larger voltage swings than conventional laboratory amplifier ICs. System designs still require careful attention to output-current demand, copper interconnects, heat removal, and protective grounding.
For a new design, verify the complete pin description, thermal characteristics, output-current derating, and safe operating limits in the manufacturer data sheet before laying out the PCB. The TO-3-8 package is intended for through-hole mounting, so mechanical clearance, lead bending, chassis mounting, and connector current capacity should be planned together. This page also provides application guidance, comparison parameters, and sourcing information beyond the basic data-sheet identification.
直接替換替代品,適用於 OPA512SM — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: OPA512SM (相同外形與佔位) — 差異在於 Peak Output Current, Product Type.
OPA512
✅ 直接替換📋 參考替代品(不在目錄中)
OPA512CM
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
OPA512AM
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
OPA541BM
✅ 直接替換聯絡詢價
查看資料表 →OPA512SM-ND
✅ 直接替換📋 參考替代品(不在目錄中)
OPA512SM 最大額定值與電氣特性
| Product Type | Very-high-current, high-power operational amplifier |
| Manufacturer | Texas Instruments |
| Amplifier Type | Single-circuit operational amplifier |
| Supply Voltage Range | ±50 V |
| Nominal Specification Supply | ±40 V |
| Maximum Total Operating Voltage | 100 V for OPA512SM |
| Peak Output Current | 15 A |
| Output Stage Class | Class A/B |
| Output Current Protection | Voltage-current limit protection |
| Package Type | TO-3-8 hermetic package |
| Terminal Count | 8 terminals |
| 安裝類型 | Through-hole |
| Minimum Common-Mode Rejection Ratio | 74 dB |
| Temperature Grade | Military grade |
| Circuit Count | 1 circuit |
OPA512SM to-3-8 hermetic package 腳位配置指南
OPA512SM(to-3-8 hermetic package 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: OPA512SM.
請參閱 資料表 以查看完整腳位配置。
典型應用
OPA512SM 適用於 6 應用s: High-Current Audio Power Stage, Laboratory High-Current Source, Industrial Actuator and Solenoid Driver, Ultrasonic Transducer Driver, Precision Power-Control Amplifier, Power Test and Measurement Fixture.
High-Current Audio Power Stage
The OPA512SM fits high-current audio output stages because it provides 15 A peak output current from a single operational-amplifier package and uses a Class A/B output stage. According to the Texas Instruments OPA512 data sheet, voltage-current limit protection helps control abnormal output conditions. The amplifier can drive a low-impedance speaker or transformer load when paired with suitable output protection and a correctly sized heat sink. Its ±50 V supply capability supports substantial voltage swing, but continuous power and copper losses rise rapidly with current. Engineers should verify output-current derating, thermal rise, connector ratings, and distortion at the intended frequency before assigning it as the final output device.
推薦
Laboratory High-Current Source
The OPA512SM can serve as the error amplifier in a laboratory current-source or voltage-control loop when the load requires amperes rather than milliamps. Its 15 A peak output current provides useful drive capability, while the 74 dB minimum common-mode rejection ratio helps limit input-referred common-mode effects. The design must limit loop current with a sense resistor or other feedback element and account for the amplifier's thermal limits under continuous DC operation. Because the package dissipates substantial power at high current, a low-inductance supply path and chassis-mounted heat sinking are essential.
推薦
Industrial Actuator and Solenoid Driver
The OPA512SM is suitable for driving industrial actuators, solenoids, or electromechanical devices that present a low-impedance load. Its 15 A peak output current exceeds the capability of conventional signal op amps, while the broad ±50 V supply capability allows a higher actuator voltage than typical logic-level drivers. A practical circuit uses the amplifier inside a closed-loop current-control topology with external current sensing and clamping. The engineer must select switching and rectification components for the load, ensure the amplifier's voltage-current limit behavior is intentional, and verify that continuous dissipation, winding transients, and connector current ratings remain within system limits.
推薦
Ultrasonic Transducer Driver
The OPA512SM can drive high-current ultrasonic transducers when the required peak current is within the device's 15 A capability. The Class A/B output stage is designed for power-amplifier service, and the wide supply range provides useful headroom for transducer drive voltage. However, ultrasonic operation is AC rather than DC, so engineers should evaluate dissipation using the actual waveform, load impedance, frequency, and duty cycle. Series inductance, current limiting, and output protection may be needed to control capacitive transducer transients. The TO-3-8 package must be connected to an adequate heat sink, and supply wiring should minimize inductance to preserve control-loop stability.
推薦
Precision Power-Control Amplifier
The OPA512SM can implement a high-power analog control stage for programmable supplies, laser-diode controllers, or precision excitation circuits. Its 15 A peak output current supplies load drive, while the minimum 74 dB common-mode rejection ratio supports stable operation across a wide input range. Feedback accuracy depends on external resistors, reference quality, Kelvin routing, and thermal stabilization. The design should place input and feedback paths away from the high-current output conductors and use low-inductance supply connections. Thermal monitoring is also necessary because a regulation loop can drive the amplifier into sustained high dissipation when the load demands excessive current or the output saturates.
推薦
Power Test and Measurement Fixture
The OPA512SM is useful in high-current test fixtures where a conventional op amp cannot supply the required load current. It can form the output stage of a programmable source, sink, or closed-loop load controller for bench and factory equipment. The stated 15 A peak output capability and voltage-current limit protection provide the basis for a robust power-output stage, but the fixture still needs external sensing, fault isolation, and emergency shutdown. Because high-current traces and connectors can create measurement errors, use Kelvin sensing and separate the sensitive return path from power-current returns. Confirm the amplifier's safe dissipation and output-current derating for the intended duty cycle.
推薦
推薦產品摘要
工程參考資料,適用於 OPA512SM — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | OPA512 | OPA512CM | OPA512AM | OPA541 | OPA512SM-ND |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | TO-3-8, 8 terminals | TO-3-8, 8 terminals | TO-3-8, 8 terminals | TO-3-8, 8 terminals | TO-3-8, 8 terminals | TO-3-8, 8 terminals |
| Peak Output Current | 15 A | 15 A | 15 A | 15 A | 15 A | 15 A |
| Supply Voltage Range | ±50 V | ±50 V | ±50 V | ±50 V | ±35 V | ±50 V |
| Circuit Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
主要差異化特點
- Higher maximum total operating voltage than the base OPA512 (對比OPA512)
- Class A/B output stage with explicit current protection (對比OPA541)
- Military-grade ordering option for demanding environments (對比OPA512CM)
設計說明
Treat the 15 A output figure as a peak capability, not a universal continuous-current rating. Establish the actual RMS current, output waveform, duty cycle, ambient temperature, and copper-loss budget for the application. Mount the TO-3-8 package to the heat sink or chassis specified by the manufacturer's thermal information, tighten the mounting hardware evenly, and verify the junction-temperature margin under worst-case loading. An external current or power limit is advisable so a fault cannot force the amplifier into continuous limiting.
Use low-inductance supply wiring and decoupling appropriate to the high output-current capability of the OPA512SM. Keep the positive and negative supply paths short and symmetrical so large load-current transitions do not create supply transients that destabilize the feedback loop. Check the combined supply voltage against the 100 V maximum for OPA512SM. Grounding should use a power-return architecture that avoids routing high-current return current through sensitive signal-reference paths.
Assign pins and lands using the manufacturer data sheet's exact TO-3-8 terminal description rather than relying on generic TO-3 conventions. Route the output directly to the power load and use separate Kelvin connections for current sensing or feedback where precision is required. Keep compensation, input, and feedback components away from output-current and supply-current paths. Provide adequate clearance around the high-voltage device and its heat sink, and design the mechanical mounting before fixing the through-hole footprint.
合規資訊
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were identified for the OPA512SM. The military-grade designation does not by itself establish AEC-Q100 qualification.