SI3008-B-FS - 2.4kbps ISOmodem | Skyworks | 8-SOIC-EP
MPN: SI3008-B-FS ✗ 停產SI3008-B-FS 概覽
An ISOmodem is a modem interface integrated with telephone-line isolation and data-access arrangements. It belongs to the modem interface IC and telecom interface IC hierarchy before connecting to broader communications equipment. This category combines modulation, line-interface, isolation, signaling, and telephone-network functions in a single IC, reducing the number of discrete components required in a line-side communication design.
The SI3008-B-FS includes a low-cost data access arrangement, parallel phone detection, fast connect, V.23 reversing, and additional security protocols. Its capacitive isolation is rated above 6000 V. These features make the device relevant to legacy data communications, alarm and monitoring systems, point-of-sale equipment, industrial terminals, and telephone-line interfaces that require network-side modem behavior rather than a modern broadband transceiver.
The device operates as a 2.4 kbps modem with support for several ITU V-series and Bell protocols. At the 2.4 kbps operating point, the SI3008-B-FS uses V.22bis, while 1200 bps operation uses V.22 or V.23 and 300 bps operation uses V.21 or Bell 103. Compatibility with V.32, V.34, V.90, and Bell 212A extends the protocol range stated for the component. Exact operating limits, clock requirements, interface timing, and electrical characteristics should be taken from the manufacturer datasheet.
Typical uses include legacy telephone-line data links, security and alarm-control equipment, remote terminals, and embedded modems requiring fast connection or parallel phone detection. The integrated isolation architecture helps separate line-side circuitry from the host system. The exposed pad provides a thermal and ground-connection surface, although its electrical net and landing-pattern requirements must follow the manufacturer pinout and layout guidance.
Designers should treat the SI3008-B-FS as a protocol-specific legacy modem rather than a general-purpose serial interface. The host processor must support the selected V-series or Bell signaling sequence, and the telephone-line network must be compatible with the selected country or regional approval. Input and output protection requirements depend on the line interface and regulatory environment, so the datasheet’s approved application circuits should guide component selection.
This product page combines the documented protocol capabilities, package information, regulatory statements, and cross-reference findings into an engineering-focused selection guide. It also distinguishes verified device attributes from specifications that still require confirmation from the manufacturer datasheet, helping designers evaluate the SI3008-B-FS without treating unspecified electrical values as guaranteed.
直接替換替代品,適用於 SI3008-B-FS — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此產品無可直接替換的替代品。
申請替代品SI3008-B-FS 規格
| Product Type | ISOmodem interface IC |
| Maximum Data Rate | 2400 bps |
| 2400 bps Modulation | V.22bis |
| 1200 bps Modulations | V.22, V.23 |
| 300 bps Modulations | V.21, Bell 103 |
| Additional Supported Formats | V.32, V.34, V.90, Bell 212A |
| Capacitive Isolation | Over 6000 V |
| Phone Detection | Parallel phone detection |
| Connection Feature | Fast connect |
| Reversing Feature | V.23 reversing |
| Security Support | SIA and other security protocols |
| 封裝 | 8-SOIC exposed pad |
| Surface-Mount Package Width | 3.90 mm |
| Surface-Mount Package Length | 0.154 inch |
| Terminal Count | 8 terminals |
| Terminal Form | Gull wing |
| Temperature Grade | Commercial |
| RoHS 狀態 | Lead-free |
| FCC Compliance | Compliant |
| China Compliance | Compliant |
| JATE Compliance | Compliant |
SI3008-B-FS 0.154 inch 腳位配置指南
SI3008-B-FS(0.154 inch 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: SI3008-B-FS.
請參閱 資料表 以查看完整腳位配置。
典型應用
SI3008-B-FS 適用於 6 應用s: Legacy Telephone Data Terminals, Alarm and Security Control Panels, Industrial Remote Monitoring, Point-of-Sale Terminals, Voice-Data Fax and Messaging Equipment, Embedded Legacy Communication Modules.
Legacy Telephone Data Terminals
The SI3008-B-FS fits legacy telephone data terminals that exchange information through V.22bis, V.22, V.23, V.21, or Bell protocols at rates up to 2400 bps. The integrated low-cost data access arrangement, fast connect, and parallel phone detection reduce the amount of line-interface circuitry required around the modem IC. Its over-6000-V capacitive isolation helps separate line-side and host-side functions, while the 8-SOIC exposed-pad package supports compact surface-mount construction. The host firmware must implement the selected modem sequence and comply with the applicable regional telephone-network requirements.
推薦
Alarm and Security Control Panels
The SI3008-B-FS is appropriate for security panels that report data through legacy telephone-line modem formats. Its support for SIA and other security protocols, fast connect, and parallel phone detection addresses common panel functions involving call establishment and line-status handling. The integrated capacitive isolation provides a useful barrier between the line-facing modem section and control electronics, rated above 6000 V in the device description. A security product must still validate the complete telephone interface, line protection, call-progress behavior, and required regional approvals rather than relying on the modem IC alone.
推薦
Industrial Remote Monitoring
The SI3008-B-FS can serve as the communication engine in industrial monitoring equipment connected to a legacy telephone line. Support for V.22bis at 2400 bps and lower-rate Bell and V-series modes provides options for matching an established remote terminal protocol. Fast connect is useful where rapid session establishment matters, while parallel phone detection can assist line-state management. The design must confirm that 2400 bps is sufficient for the payload and must implement the required isolation, protection, and network-interface layout around the device.
推薦
Point-of-Sale Terminals
The SI3008-B-FS is suitable for point-of-sale equipment that uses a legacy switched-network connection for transaction reporting. V.22bis at 2400 bps can support low-volume modem sessions, while V.22, V.23, V.21, and Bell 103 modes allow compatibility with older endpoints. Parallel phone detection and fast connect can simplify operation around shared or intermittently used analog lines. The final circuit still needs the telephone-network components, protection strategy, regional compliance, and host protocol implementation required by the deployed point-of-sale network.
推薦
Voice-Data Fax and Messaging Equipment
The SI3008-B-FS can be incorporated into legacy voice-band equipment that must exchange low-speed data over an analog telephone connection. Its support for several V-series and Bell formats allows selection of a mode compatible with the remote endpoint. The 8-SOIC exposed-pad package and integrated capacitive isolation make it practical for compact multi-function equipment where board area is constrained. Designers should verify the complete data-access arrangement, line-coupling network, timing behavior, and coexistence requirements for any simultaneous voice service before approving the implementation.
推薦
Embedded Legacy Communication Modules
The SI3008-B-FS is useful in embedded communication modules that expose a legacy modem function to a host processor. The device consolidates modulation, isolation, fast connect, parallel phone detection, and data-access functions into one IC, reducing the external component count. V.22bis provides a 2400 bps operating mode, with additional formats available for compatibility with older infrastructure. Because the exact supply voltage, interface timing, and electrical limits are not established by the indexed product records, an implementation should begin with the manufacturer datasheet and approved reference design rather than extrapolate values.
推薦
工程參考資料,適用於 SI3008-B-FS — 比較、設計指引及合規資訊。
選型指南
Do not select it for broadband, LTE, Ethernet, or high-speed DSL connectivity, and do not assume that the 2400 bps modem rate provides modern file-transfer performance. It is most appropriate when an established endpoint, alarm panel, terminal, or network requires one of the supported legacy formats.
SI3008-B-FSR is the closest related ordering code identified, but it should be used only after the manufacturer confirms package, exposed-pad, protocol, and production-status equivalence. No other drop-in alternative was verified, so engineers should either use the specified MPN or obtain a formal manufacturer cross-reference before changing the PCB component. The final design should also validate regional telephone-network approval, protection, isolation layout, and host timing.
設計說明
Place the SI3008-B-FS in accordance with the manufacturer’s exposed-pad land pattern and pin-definition drawing. The exposed pad must have the documented copper and solder treatment, and it may also serve as the device ground connection. Do not infer the pad net from a generic SOIC footprint because an incorrect connection can compromise grounding, thermal performance, isolation layout, or manufacturability.
Keep the telephone-line-facing section and the host-side circuitry physically organized around the device’s isolation boundary. Follow the manufacturer’s clearance and isolation-layout guidance, preserve the intended pad and keepout geometry, and route sensitive modem signals away from high-energy line-transients. The complete protection and line-network arrangement must be designed together with the SI3008-B-FS to preserve isolation and regulatory performance.
Do not treat the suffix changes in SI3008-B-FS and SI3008-B-FSR as proof of electrical equivalence. Confirm the ordering code, package construction, pin definitions, exposed-pad net, protocol set, lifecycle status, and approved application circuit. Cross-reference tools can help locate candidates, but a production substitution requires a manufacturer-backed comparison against both datasheets.
The modem’s line-side circuitry can be affected by telephone-network transients and coupling between the line and host interface. Use the manufacturer-approved protection and filtering approach, maintain the intended isolation geometry, and test conducted and radiated emissions in the finished product. Do not add long unprotected traces or substitute generic surge components without checking their pulse-energy and capacitance effects on modem operation.
合規資訊
The product records identify the component as lead-free and state FCC, China, and JATE compliance. RoHS, REACH, halogen-free, and conflict-minerals status require confirmation from the current manufacturer documentation.