TLE62543GXUMA1 - 125 kBd CAN Transceiver | Infineon
MPN: TLE62543GXUMA1 ✗ 停產TLE62543GXUMA1 概覽
A CAN transceiver, also called a CAN physical-layer interface, converts logic-level signals from a CAN controller into differential bus signals and converts received bus levels back into controller-compatible logic signals. The TLE6254-3G family belongs to the interface IC hierarchy: CAN transceiver > physical-layer interface > bus interface > semiconductor.
The verified product information identifies fault-tolerant low-speed CAN operation, sleep and standby operating modes, and one transmitter and one receiver. The TLE62543GXUMA1 supports data rates up to 125 kBd. Its 5 V supply operating range covers the listed 4.75 V minimum and 5.25 V maximum values, making it suitable for conventional 5 V embedded systems. The PG-DSO-14 package supports automated surface-mount production.
The sleep and standby functions are important in automotive and industrial equipment where the CAN interface must reduce current consumption when the bus is inactive. Sleep mode supports a low-power state, while standby provides an intermediate operating state. The available data does not quantify the dominant current, recessive or dominant output levels, propagation delay, bus-fault thresholds, isolation withstand voltage, or temperature limits, so those values should be confirmed in the manufacturer datasheet before final design release.
Typical uses include automotive body electronics, industrial automation, elevator controls, building automation, and embedded CAN networks. In an automotive installation, the transceiver can connect a microcontroller-based CAN controller to a vehicle CAN bus while fault-tolerant operation helps the interface continue operating when the bus is disturbed.
PCB design should provide a solid ground connection, short CAN and CAN-bar traces, appropriate termination at each end of the bus, and decoupling close to the 5 V supply pins. Exact capacitor values, common-mode choke requirements, and layout clearances are not included in the verified data and must be taken from the manufacturer datasheet.
This product page consolidates the verified distributor specifications, a structured comparison with candidate drop-in alternatives, and practical application guidance. It also clearly identifies where purchasing, lead-time, lifecycle, pin-level, and detailed electrical data require confirmation from the manufacturer or an authorized distributor.
直接替換替代品,適用於 TLE62543GXUMA1 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
TLE62541G
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
TLE62542G
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
TLE6254-3G
✅ 直接替換📋 參考替代品(不在目錄中)
TLE6236G
✅ 直接替換📋 參考替代品(不在目錄中)
TLE6251DXUMA2
✅ 直接替換聯絡詢價
查看資料表 →TLE62543GXUMA1 規格
| Product Type | Fault-tolerant low-speed CAN bus transceiver |
| Transmitter Count | 1 transmitter |
| Receiver Count | 1 receiver |
| Bus Interface | 1 CAN bus channel |
| Maximum Data Rate | 125 kBd |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Operating Modes | Sleep and standby |
| 封裝 | PG-DSO-14, 14 pins |
| Package Type | 14-pin surface-mount DSO package |
| 安裝類型 | Surface mount |
| Temperature Grade | Automotive grade |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| Package Code | SOP |
| RoHS 狀態 | RoHS3 compliant |
| Data Rate Class | Low-speed CAN, up to 125 kBd |
TLE62543GXUMA1 sop 腳位配置指南
TLE62543GXUMA1(sop 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: TLE62543GXUMA1.
請參閱 資料表 以查看完整腳位配置。
典型應用
TLE62543GXUMA1 適用於 6 應用s: Automotive Body Control CAN Bus, Industrial Automation CAN Network, Building Automation and HVAC Control, Elevator and Door-Control Networks, Sensor and Actuator CAN Hubs, Low-Speed Embedded CAN Controller Interface.
Automotive Body Control CAN Bus
The TLE62543GXUMA1 fits conventional automotive body-control networks because it is identified as an automotive-grade, fault-tolerant CAN transceiver rated up to 125 kBd. It can sit between a body-control microcontroller's CAN controller and the physical CAN bus, converting controller logic into bus signals and returning received bus information. The 4.75 V to 5.25 V operating range suits a regulated 5 V electronics rail, while sleep and standby functions help reduce consumption in parked or inactive operating states. Designers should preserve the 14-pin package layout, provide local supply decoupling, and use bus termination only at the two ends of the network. Because the supplied data does not specify exact logic levels, loop delay, bus-fault thresholds, or temperature limits, those details require confirmation from the manufacturer datasheet before a safety-related automotive release.
推薦
Industrial Automation CAN Network
The TLE62543GXUMA1 is appropriate for low-speed industrial automation links operating at up to 125 kBd on a 5 V supply. It can bridge a programmable controller, sensor hub, actuator controller, or operator panel using the physical CAN bus while providing the fault-tolerant behavior expected in electrically noisy equipment cabinets. Sleep and standby modes are useful when equipment spends substantial time inactive, allowing a system designer to coordinate low-power operation without repeatedly powering the complete controller. The PG-DSO-14 surface-mount package also supports compact, automated assembly. A practical implementation should use a short differential route from the transceiver toward the bus connector, provide a low-impedance ground return, and place termination only at the network endpoints. Verify EMC, surge, and ESD requirements against the application-specific standards before production, because those ratings are not quantified in the verified source data.
推薦
Building Automation and HVAC Control
The TLE62543GXUMA1 can connect building automation, HVAC, or access-control equipment operating on a conventional low-speed CAN network. Its 125 kBd maximum rate is suited to supervisory control traffic rather than high-bandwidth sensor streaming, while fault-tolerant operation is valuable when the bus runs near motors, relays, or switching equipment. The 4.75 V to 5.25 V supply range allows use with a regulated 5 V rail, and sleep or standby control can support low-power panel designs. Because the transceiver exposes one transmit and one receive path, a controller-side CAN node can exchange both commands and status data with remote modules. The implementation should maintain closely coupled CAN and CAN-bar routing, use suitable protection for long building cables, and confirm termination strategy from the network topology. Exact wake-up timing and mode-control electrical behavior require the Infineon datasheet.
推薦
Elevator and Door-Control Networks
The TLE62543GXUMA1 is suitable for elevator landing controls, door controllers, and equipment networks that use low-speed CAN communication. At up to 125 kBd, it supports command and status exchange between a central controller and distributed peripheral modules without the data rate of a high-speed CAN or CAN FD network. Fault-tolerant operation can improve robustness in environments containing relays, motor contactors, and long cable runs, while the automotive-grade identification and 14-pin surface-mount package support robust compact assemblies. Sleep and standby modes may be coordinated with the controller to reduce system activity when the installation is idle. The PCB layout should keep the differential bus route away from switching nodes, provide a solid transceiver ground connection, and include the required protection network. The supplied information does not identify the recommended bus protection components or isolation rating, so these must be established during schematic review.
推薦
Sensor and Actuator CAN Hubs
The TLE62543GXUMA1 can serve as the physical-layer element in a compact CAN hub linking a controller to distributed sensors or actuators. Its one-transmitter, one-receiver arrangement is appropriate for a conventional CAN node, and the maximum 125 kBd rate matches control and monitoring traffic common in industrial equipment. The 4.75 V to 5.25 V supply range permits operation from a regulated 5 V rail, and the DSO-14 package supports high-density PCB assembly. Sleep and standby functionality can help a hub enter a low-consumption state when no network activity is expected, although the controller must drive the relevant mode inputs correctly. For reliable implementation, follow the manufacturer reference layout, keep the CAN differential pair tightly coupled, place local bypass capacitance at the supply pins, and use endpoint termination. Verify the final bus topology and branch lengths against the device documentation.
推薦
Low-Speed Embedded CAN Controller Interface
The TLE62543GXUMA1 is suited to embedded systems that require a conventional CAN physical-layer interface beside a microcontroller or dedicated CAN controller. The controller handles protocol framing, arbitration, and message handling, while the transceiver translates between controller logic and the differential physical bus. With a 125 kBd maximum data rate, it supports legacy CAN communication in supervisory, diagnostic, and equipment-control roles. The 5 V supply range and 14-pin surface-mount package fit many established embedded boards, while fault-tolerant operation supports electrically demanding installations. Sleep and standby modes should be integrated into the firmware power-state strategy rather than used without checking wake-up requirements in the datasheet. During layout, minimize the distance between the controller and transceiver where practical, use a continuous ground reference beneath the bus route, and place bus protection close to the connector. No pin-level assignment was present in the verified data, so the schematic must follow the official package drawing.
推薦
工程參考資料,適用於 TLE62543GXUMA1 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | TLE62541G | TLE62542G | TLE6254-3G | TLE6236G | TLE6251DXUMA2 |
|---|---|---|---|---|---|---|
| Package | PG-DSO-14 | PG-DSO-14 | PG-DSO-14 | PG-DSO-14 | PG-DSO-14 | PG-DSO-14 |
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
主要差異化特點
- Purpose-built fault-tolerant low-speed CAN interface (對比TLE6251DXUMA2)
- Defined automotive-grade ordering option (對比TLE6236G)
- Single-node CAN channel with dedicated sleep and standby states (對比TLE6254-3G)
- Compact production-oriented surface-mount package (對比TLE62541G)
設計說明
Route CAN and CAN-bar as a short, tightly coupled differential pair from the TLE62543GXUMA1 toward the connector or bus branch. Avoid placing the pair alongside switching nodes, relay contacts, or high-current motor paths, and provide a continuous ground reference beneath the route where the PCB stack-up permits. Exact impedance and clearance requirements are not contained in the verified data, so use the Infineon layout guidance and the actual connector and cable requirements for the finished design.
The verified supply range is 4.75 V to 5.25 V, so the transceiver must be powered from a regulated 5 V rail that remains within those limits under load and transient conditions. Place the required bypass capacitors immediately beside the relevant supply and ground pins, and keep the supply return path short. The supplied sources do not specify capacitor values, dominant current, standby current, or startup timing, so those quantities must be taken from the manufacturer datasheet before component selection.
Do not treat every CAN transceiver as pin-compatible merely because it is described as a 14-pin SOIC or DSO device. Confirm the package drawing, exposed-pad requirement, CAN and CAN-bar assignments, receiver-output interface, mode-control inputs, and supply pins against the TLE62543GXUMA1 datasheet. Also avoid assuming that TLE6236G or TLE6251DXUMA2 is a drop-in replacement: the supplied comparison pages do not provide enough verified pin and parameter data to authorize substitution without schematic review.
CAN networks can be exposed to conducted and radiated disturbances, especially in automotive and industrial installations. Place any approved bus protection network close to the connector rather than far along the PCB, and terminate the bus with the specified resistance only at the two physical endpoints. The correct protection component, common-mode choke, split termination arrangement, and fault-current limits are not specified in the supplied data and must be selected from the manufacturer recommendations and application requirements.
合規資訊
The verified product listing identifies RoHS3 compliance and automotive temperature grade. It does not explicitly state REACH, AEC-Q100 qualification, lead-free status, halogen-free status, or conflict-minerals compliance.