MPN: VSC7418XKT-01 ✗ 停產VSC7418XKT-01 概覽
A Carrier Ethernet switch is a network-interface integrated circuit that forwards Ethernet frames between multiple ports while supporting carrier-grade transport requirements. In the product hierarchy, the VSC7418XKT-01 is a switch IC, then a network interface IC, then an integrated circuit and semiconductor. Its 11-port configuration allows one communications system to consolidate several Ethernet-facing connections without using a separate physical switch for every port.
The principal documented feature of this ordered device is its 11-port Layer-2 SGMII Carrier Ethernet implementation. The -01 ordering designation identifies the part covered by the VSC7418-01 datasheet, while the 284-pin TQFP body provides a large, high-pin-count implementation capable of exposing numerous serial network, control, clock, power, and status connections. The 24 mm by 24 mm package is intended for surface-mount PCB assembly rather than manual socket installation.
The VSC7418 is identified by Microchip as an End of Life device, making lifecycle planning essential for projects using it. New production should therefore begin with an availability and lifecycle review rather than assuming that an existing inventory position can be replenished indefinitely. The VSC7418XKT-01 suffix also includes an -01 revision and TQFP packaging information that must be retained when comparing documentation or replacement candidates.
Typical deployment environments include telecommunications access equipment, Carrier Ethernet aggregation systems, industrial Ethernet equipment, and other network infrastructure that requires a multiport Layer-2 switch. In these systems, the switch IC can organize traffic among service-facing ports while the surrounding board supplies power, clocking, PHY or optical modules, magnetic interfaces, and management circuitry.
PCB planning requires care because a 284-pin TQFP has a much larger footprint and more escape routes than a conventional small-outline package. Designers should follow the manufacturer land pattern, maintain high-speed trace geometry, provide local decoupling and reference-clock conditioning, and keep copper-return paths continuous. This page consolidates the confirmed product identity, lifecycle status, package information, sourcing workflow, and engineering considerations relevant to the VSC7418XKT-01.
直接替換替代品,適用於 VSC7418XKT-01 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此產品無可直接替換的替代品。
申請替代品VSC7418XKT-01 最大額定值與電氣特性
| Product Type | 11-port Layer-2 Carrier Ethernet switch |
| Port Count | 11 ports |
| Network Interface | SGMII |
| Switching Layer | Layer 2 |
| Device Variant | VSC7418-01 |
| Orderable MPN | VSC7418XKT-01 |
| 封裝 | 284-TQFP, 24 mm x 24 mm |
| 腳位數 | 284 pins |
| 安裝類型 | Surface mount |
VSC7418XKT-01 284-tqfp, 24 mm x 24 mm 腳位配置指南
VSC7418XKT-01(284-tqfp, 24 mm x 24 mm 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: VSC7418XKT-01.
請參閱 資料表 以查看完整腳位配置。
典型應用
VSC7418XKT-01 適用於 6 應用s: Telecommunications Access Equipment, Carrier Ethernet Aggregation, Industrial Ethernet Control Systems, Network Monitoring Equipment, Industrial Network Gateways, Carrier Ethernet Line Cards.
Telecommunications Access Equipment
The VSC7418XKT-01 fits access and aggregation equipment requiring an 11-port, Layer-2 Carrier Ethernet switching function with SGMII connectivity. It can organize multiple service-facing Ethernet links in a telecommunications chassis while the board supplies clocking, physical-layer or optical modules, magnetics, and management support. The principal engineering constraint is its End of Life status: the part is most appropriate for maintaining a proven platform or executing an approved continuation build rather than launching a design with uncertain long-term supply.
推薦
Carrier Ethernet Aggregation
The 11-port SGMII architecture of the VSC7418XKT-01 allows a Layer-2 aggregation board to connect several network-facing channels through one switching IC. This arrangement can reduce the number of discrete switching functions needed near access or line-card electronics. Interface count, supported rate, timing, and management behavior must be checked against the VSC7418-01 datasheet before layout begins. Because the device is End of Life, procurement and thermal planning should account for limited future availability.
推薦
Industrial Ethernet Control Systems
VSC7418XKT-01 can serve as the central Layer-2 switching element in an industrial Ethernet controller when the system requires eleven SGMII-facing ports and a compact switching architecture. It is particularly relevant to equipment combining machine control, network monitoring, and communications interfaces. The system still needs isolated or protected physical layers, industrial power regulation, clock distribution, and environmental validation. The End of Life designation makes supply continuity a central qualification issue for new industrial programs.
推薦
Network Monitoring Equipment
The VSC7418XKT-01's 11-port Layer-2 switching function can consolidate monitoring, management, and backhaul links in network test or surveillance equipment. SGMII provides a high-speed digital interface between the switch and physical-layer devices, while Layer-2 forwarding organizes traffic across the connected ports. The implementation must account for the 284-pin TQFP footprint, reference-clock quality, board-level thermal performance, and isolation requirements. Verify availability before committing to a long-life deployment.
推薦
Industrial Network Gateways
A gateway combining fieldbus conversion, Ethernet communications, and local storage can use the VSC7418XKT-01 to manage multiple high-speed network-facing links. Its 11 SGMII ports support consolidation of copper and fiber-backed services, depending on the external PHY or optical modules selected. Designers should use the manufacturer's reference layout for high-speed escape routing and clock distribution. For new gateways, compare the End of Life VSC7418 against currently supported switches rather than treating legacy availability as a long-term supply guarantee.
推薦
Carrier Ethernet Line Cards
The VSC7418XKT-01 is suited to telecommunications line-card designs that need multiple SGMII connections and Layer-2 switching within a compact board. External PHY, optical, and network-interface modules provide the physical media connections, while the switch IC coordinates Ethernet frame forwarding among service ports. The large 284-TQFP package requires careful fanout, power delivery, and heat spreading. Maintenance programs with an established footprint may benefit from its continuity, but new line cards should include a formal lifecycle and migration review.
推薦
推薦產品摘要
工程參考資料,適用於 VSC7418XKT-01 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Brand | Microchip Technology |
| Package | 284-TQFP, 24 mm x 24 mm |
| Port Count | 11 ports |
| Network Interface | SGMII |
| Switching Layer | Layer 2 |
| Product Family | VSC7418 |
| Device Variant | VSC7418-01 |
| Lifecycle Status | End of Life |
| Pin Count | 284 pins |
| Mounting Type | Surface mount |
主要差異化特點
- Established 11-port Carrier Ethernet switching integration (對比Generic single-port Ethernet controller)
- High-density integration in an established 284-TQFP footprint (對比Lower-pin-count Ethernet interface IC)
- Carrier-oriented Layer-2 switching architecture (對比Software-forwarded network interface)
設計說明
Use the Microchip VSC7418-01 package drawing and reference layout for the 284-TQFP land pattern, pad dimensions, solder mask, and pin-1 orientation. Route every interface with continuous reference planes and avoid split return paths. The high pin count creates a large escape-routing problem, so fanout density, layer-transition geometry, and simultaneous switching-noise margin should be reviewed with the manufacturer's interface guidelines before releasing the PCB.
Follow the manufacturer power-supply connection and decoupling recommendations exactly, including the assignment of analog, digital, and I/O supply pins if multiple rails are specified. Place bypass capacitors adjacent to their intended supply pins and verify startup sequencing, voltage tolerance, and ripple requirements against the VSC7418-01 datasheet. Do not infer power limits from the package name; confirm them from the manufacturer documentation before component selection and thermal analysis.
Estimated thermal planning should begin with the actual worst-case input power, ambient temperature, board construction, and exposed-pad or lead-frame assumptions listed in the manufacturer documentation. Calculate junction temperature from the resulting package dissipation and board-dependent thermal resistance, then provide copper area and airflow as required. This estimate is a design calculation rather than a manufacturer performance guarantee, so validate it in the final assembly.
Treat the reference clock and SGMII links as high-speed interfaces. Use the manufacturer's recommended topology, impedance rules, via geometry, and receive-point placement to control skew and insertion loss. Confirm compatible clock generation and I/O voltage levels with every external PHY or transceiver. Review return-loss and jitter behavior on assembled coupons before production, especially when long escape routes are required by the 284-pin footprint.
合規資訊
The manufacturer product page confirms End of Life status, the 11-port Layer-2 SGMII Carrier Ethernet configuration, and the VSC7418-01 documentation, but no compliance declarations are shown in the available product information. Compliance must therefore be confirmed for the exact ordered part and manufacturing lot.