AD7713AR - 24-Bit, 2-Input Sigma-Delta ADC | Analog Devices
料号: AD7713AR ✓ 量产中AD7713AR 概述
A sigma-delta ADC is a voltage regulator category member that converts an analog input into a high-resolution digital word using oversampling, noise shaping, and digital filtering. The AD7713 belongs to the analog-to-digital converter hierarchy and is intended for precision instrumentation where resolution, programmable gain, and input flexibility matter more than high conversion speed.
The AD7713AR provides up to 24 bits of no-missing-code performance, two selectable analog inputs, and a proprietary programmable-gain front end. Its sigma-delta architecture is optimized for low-frequency signals such as sensor outputs, process-control measurements, and laboratory inputs. The serial interface reduces the number of signal traces needed between the converter and a digital controller.
The device can be used as a complete analog front end because the input stage includes programmable gain and signal conditioning ahead of the converter. This architecture is particularly useful when a transducer produces a relatively small differential voltage. The manufacturer describes the AD7713 as accepting either low-level signals directly from a transducer or higher-level signals up to 4 × VREF, subject to the device operating limits.
Typical uses include pressure and temperature instrumentation, industrial process measurement, strain-gauge and bridge-based sensing, laboratory data acquisition, and low-level battery monitoring. Its 24-bit resolution can reduce the need for analog amplification when the source signal is already differential and remains within the input range.
The primary design trade-off is conversion rate versus resolution and filtering. Sigma-delta conversion is strongest for slowly changing signals, while digital filter settings and settling time determine how quickly the converter responds to an input transition. Designers should select the gain, filter rate, excitation method, and input protection to match the transducer and measurement bandwidth.
This product page organizes the AD7713AR specifications, package information, sourcing route, drop-in alternatives, application guidance, and engineering considerations into a focused reference for evaluating a 24-bit low-frequency measurement converter.
直接替换替代料: AD7713AR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD7713AR (相同外形与封装尺寸) ——差异在于 Converter Type, Input Architecture.
AD7713ARZ
✅ 直接替换📋 参考替代料(不在目录中)
AD7713AR 最大额定值与电气特性
| Converter Type | Sigma-delta ADC |
| 分辨率 | 24 bit |
| Number of Inputs | 1 or 2 inputs |
| Input Architecture | Programmable-gain analog front end |
| No-Missing-Code Performance | Up to 24 bits |
| Transducer-Level Input Support | Low-level signals |
| Maximum High-Level Input Relationship | 4 × VREF |
| Output Interface | Serial digital output |
| Signal Conditioning | Programmable gain |
| 封装 | 24-pin SOIC |
| 安装类型 | Surface mount |
AD7713AR 24-pin soic 引脚配置指南
AD7713AR(24-pin soic 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD7713AR.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD7713AR 适用于 6 应用s: Industrial Pressure Transmitters, RTD Temperature Measurement, Strain-Gauge Load Cells, Laboratory Data Acquisition, Process Control and Sensor Interfaces, Battery and Energy Monitoring.
Industrial Pressure Transmitters
The AD7713AR fits low-speed pressure transmitters because its programmable-gain front end can condition a small differential bridge output and its sigma-delta converter provides up to 24-bit resolution. The serial interface limits the number of interconnects required between the transducer and a transmitter microcontroller. Designers should choose the gain, digital filter rate, and reference so the full bridge range remains inside the input limits without sacrificing the settling time required by the pressure loop.
推荐
RTD Temperature Measurement
AD7713AR is applicable to precision RTD temperature systems because it integrates matched excitation current sources for three-wire RTD measurement and offers a programmable-gain input stage. The 24-bit conversion resolution is useful when the temperature error budget requires fine measurement granularity. Proper use requires matching the excitation scheme to the sensor resistance, confirming the analog common-mode range, and selecting a filter and settling time appropriate for thermal response.
推荐
Strain-Gauge Load Cells
The AD7713AR suits strain-gauge load cells that produce small differential signals and change relatively slowly. Its programmable gain reduces the amount of external analog amplification required, while 24-bit resolution preserves fine changes in bridge output. A practical design must account for bridge excitation voltage, input common-mode limits, four-wire or six-wire lead compensation, PCB stress, and calibration drift before converting force measurements into useful results.
推荐
Laboratory Data Acquisition
AD7713AR can serve as the measurement front end in laboratory instruments that emphasize resolution and low-level differential accuracy over high sample rate. The programmable-gain stage accepts transducer-level signals, and the serial digital output allows direct connection to a control processor. For reproducible measurements, designers should use a stable reference, controlled excitation, appropriate filtering, calibration routines, and layouts that separate sensitive analog inputs from digital switching nodes.
推荐
Process Control and Sensor Interfaces
The AD7713AR is appropriate for process-control sensor interfaces that present slow-changing process variables through a low-level differential output. The high-resolution conversion result can support closed-loop control, diagnostics, or calibration data without requiring a fast multiplexing ADC. Engineering priorities include stable excitation and reference sources, protection from industrial transients, grounded return paths, selectable digital filtering, and a controller-compatible serial interface.
推荐
Battery and Energy Monitoring
AD7713AR can support low-level battery or energy-monitor front ends when cell voltage is scaled into the converter’s analog range and changes slowly. Its programmable gain allows a compact signal chain, while the serial output provides a direct numerical measurement to a monitoring controller. The design must include protection against transient voltage, verify the reference-to-cell relationship, and select a conversion schedule that balances energy use against the required measurement update rate.
推荐
推荐产品汇总
工程参考数据: AD7713AR ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD7713ARZ |
|---|---|---|
| Package | 24-pin SOIC | 24-pin SOIC |
| Brand | Analog Devices | Analog Devices |
| Resolution | 24 bit | 24 bit |
| Converter Architecture | Sigma-delta ADC | Sigma-delta ADC |
| Number of Inputs | 1 or 2 inputs | 1 or 2 inputs |
| Input Front End | Programmable-gain front end | Programmable-gain front end |
| Low-Level Transducer Input | Supported | Supported |
| Higher-Level Input Relationship | Up to 4 × VREF | Up to 4 × VREF |
| Digital Output | Serial digital output | Serial digital output |
关键差异点
- Integrated excitation for three-wire RTD systems (对比 AD7714ARZ-5)
- Direct transducer-level measurement capability (对比 AD7714ARZ-5)
- Close drop-in sourcing option (对比 AD7713ARZ)
设计说明
Keep the reference, analog input, and ground paths short and away from digital clocks and serial-data traces. Place input and reference decoupling capacitors close to their associated pins, and follow the manufacturer’s recommended single-point or closely connected analog and digital grounding arrangement. For RTD and bridge inputs, minimize copper mismatch and thermal gradients because connector heating and asymmetric current paths can create measurement errors that are unrelated to converter resolution.
Select the digital filter and data rate together rather than optimizing resolution independently. A slower filter can improve rejection of noise outside the measurement bandwidth but generally increases settling time after an input change. Validate the complete acquisition cycle with the intended sensor, excitation source, and reference. Allow enough time for digital filtering to settle before taking the result, particularly in control loops that respond to step changes.
Verify the reference voltage, supply voltage, analog input range, and gain combination before applying power. The manufacturer permits higher-level signals up to 4 × VREF, but this relationship does not override other absolute-maximum or common-mode limits. Use a stable low-noise reference, avoid excessive supply ripple at the converter, and add appropriate protection ahead of sensitive inputs where the measurement source can produce transients.
Do not assume that a 24-bit rating automatically provides 24 useful bits in every circuit. Input noise, reference drift, excitation variation, gain error, filter selection, grounding, and PCB leakage can reduce practical resolution. Calibrate offset and gain, characterize noise at the intended data rate, and test the complete sensor-to-digital path under its actual power and environmental conditions.