AD820AR - Low-Power JFET Op Amp, 5-36 V | Analog Devices
料号: AD820AR ✓ 量产中AD820AR 概述
A JFET-input operational amplifier is an analog signal-conditioning device whose field-effect input stage provides very high input impedance and low input bias current. The AD820 belongs to the operational-amplifier hierarchy, where it functions as a precision voltage amplifier, buffer, comparator, or instrumentation front end. Its low input bias current makes it suitable for sensors and transducers that cannot tolerate significant loading.
The AD820AR supports supply voltages from 5 V to 36 V in single-supply operation and from ±2.5 V to ±18 V in dual-supply operation. Its input range can extend below the negative rail in single-supply mode, allowing signals referenced to ground to be processed without a negative supply. Rail-to-rail output swing provides useful output-voltage headroom for battery-powered, industrial, and instrumentation systems.
The manufacturer describes the AD820 as a low-power, precision JFET-input amplifier. Its low input bias current supports high-impedance sources, while low-power operation reduces system heat in portable and distributed measurement equipment. A gain-bandwidth product of 1.8 MHz is specified in distributor component data, and the device is packaged as an 8-lead SOIC in the 0.154-inch, 3.90 mm-width family.
Typical uses include pH and electrochemical sensing, biomedical instrumentation, data acquisition, precision current measurement, and buffering high-impedance transducers. In each circuit, the op amp provides gain and isolation while avoiding excessive input loading. The wide supply range also allows operation from compact 5 V systems through higher-voltage industrial rails.
Designers should verify the output swing, input range, noise, offset, bias current, and stability with the actual feedback network and load. Decoupling capacitors should be placed close to the supply pins, and common-mode and output-swing limits must be checked across the complete signal range.
This product page combines the AD820AR supply capabilities, package information, replacement analysis, application guidance, and design notes in a compact engineering reference for instrumentation and precision analog layouts.
直接替换替代料: AD820AR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD820AR (相同外形与封装尺寸) ——差异在于 Amplifier Type, Number of Circuits.
AD820AR 最大额定值与电气特性
| Amplifier Type | Single precision JFET-input operational amplifier |
| Number of Circuits | 1 circuit |
| Single-Supply Voltage Range | 5 V to 36 V |
| Dual-Supply Voltage Range | ±2.5 V to ±18 V |
| 输入电压范围 | Extends below the negative rail in single-supply operation |
| 输出类型 | Rail-to-rail |
| Gain-Bandwidth Product | 1.8 MHz |
| 封装 | 8-lead SOIC, 0.154 inch (3.90 mm) width |
| 安装类型 | Surface mount |
AD820AR 引脚配置
| 引脚 1 | NC — Not connected |
| 引脚 2 | −IN — Inverting input |
| 引脚 3 | +IN — Non-inverting input |
| 引脚 4 | V− — Negative supply |
| 引脚 5 | NC — Not connected |
| 引脚 6 | OUT — Output |
| 引脚 7 | V+ — Positive supply |
| 引脚 8 | NC — Not connected |
典型应用
AD820AR 适用于 6 应用s: Electrochemical and pH Sensor Interface, Biomedical Instrumentation, Industrial Pressure Transducer Conditioning, Battery-Powered Data Acquisition, Precision Current Measurement, Low-Level Sensor Signal Buffering.
Electrochemical and pH Sensor Interface
The AD820AR fits electrochemical and pH sensor interfaces because its JFET input avoids drawing substantial bias current from a high-impedance sensing element. The amplifier can process a ground-referenced input from a single 5 V to 36 V supply, including signals that extend below the 0 V rail in single-supply operation. Its 1.8 MHz gain-bandwidth product is sufficient for moderate-bandwidth gain stages. The main design consideration is preserving sensor cleanliness and guarding high-impedance input traces from leakage and interference.
推荐
Biomedical Instrumentation
The AD820AR is suitable for biomedical instrumentation front ends that must amplify weak signals without significantly loading the source. Its JFET-input architecture supports low-bias-current operation, while the true single-supply capability permits ground-centered sensor signals from a 5 V system. Rail-to-rail output increases usable signal range in compact equipment. Board-level precautions remain essential because patient-adjacent circuits require suitable isolation, leakage control, and protection beyond the amplifier itself.
推荐
Industrial Pressure Transducer Conditioning
The AD820AR can condition outputs from high-impedance pressure and displacement transducers in industrial systems. Low input bias current reduces errors in resistive and capacitive sensor networks, and the broad 5 V to 36 V supply range supports both portable instruments and higher-voltage industrial controls. The 1.8 MHz gain-bandwidth product permits useful closed-loop bandwidth for slow process signals. Use short guarded inputs, clean references, and an output stage designed for the required load.
推荐
Battery-Powered Data Acquisition
The AD820AR fits battery-powered data-acquisition modules that need to amplify low-level sensor outputs from a compact 5 V supply. Its low-power JFET-input architecture reduces loading and heat, while true single-supply operation accommodates signals near or below ground without a negative rail. The amplifier can provide gain, buffering, or active filtering at signal bandwidths supported by its 1.8 MHz gain-bandwidth product. Verify quiescent current and shutdown behavior against the complete battery budget.
推荐
Precision Current Measurement
The AD820AR is appropriate for precision current measurement when the sensing element has high impedance and requires minimal input bias current. In a shunt-based circuit, the amplifier can buffer the measurement node and prevent downstream instrumentation from loading the shunt. Operation from 5 V to 36 V offers flexibility between compact test equipment and industrial supplies. Accuracy ultimately depends on resistor matching, offset error, reference quality, and correct use of the manufacturer's recommended compensation network.
推荐
Low-Level Sensor Signal Buffering
The AD820AR works well as a unity-gain or moderate-gain buffer for low-level sensor outputs because the JFET input minimizes source loading. Its rail-to-rail output supports systems where the usable signal range extends close to the supply rails, and the wide supply range supports both 5 V portable products and 36 V industrial systems. In practical layouts, keep input traces short, provide a stable reference or bias path, and verify capacitive-load stability with the actual feedback network.
推荐
推荐产品汇总
工程参考数据: AD820AR ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD820ARZ |
|---|---|---|
| Package | 8-lead SOIC | 8-lead SOIC |
| Brand | Analog Devices | Analog Devices |
| Amplifier Type | Precision JFET-input operational amplifier | Precision JFET-input operational amplifier |
| Number of Circuits | 1 circuit | 1 circuit |
| Single-Supply Voltage Range | 5 V to 36 V | 5 V to 36 V |
| Dual-Supply Voltage Range | ±2.5 V to ±18 V | ±2.5 V to ±18 V |
| Output Type | Rail-to-rail | Rail-to-rail |
| Gain-Bandwidth Product | 1.8 MHz | 1.8 MHz |
| Ordering Designation | AD820AR | AD820ARZ lead-free designation |
关键差异点
- Direct same-family ordering alternative (对比 AD820ARZ)
- True single-supply signal handling (对比 AD820ARZ)
- JFET-input instrumentation positioning (对比 AD820ARZ)
设计说明
Place the supply bypass capacitor physically close to the AD820AR power pins and connect it to a low-impedance ground plane. Keep the +IN and −IN routes short, especially for high-impedance sources, because leakage through PCB contamination or nearby switching nodes can dominate the signal. Route sensitive inputs away from power-converter traces and use a grounded guard where the board process permits it.
Do not assume that rail-to-rail output means the output can reach either supply rail under every load. Check output swing, input common-mode range, and output-current limits in the manufacturer data sheet for the selected supply and load. Likewise, true single-supply operation does not remove the need to protect inputs from excessive voltage during power transitions; add clamping or series resistance when external nodes can exceed the amplifier limits.
Use the compensation or feedback configuration recommended by Analog Devices for the intended gain and capacitive load. Feedback components should be positioned close to the relevant pins to minimize parasitic feedback paths. When driving long cables or capacitive loads, isolate the amplifier with a small isolation resistor and validate stability using the actual load. This is especially important in long-cable instrumentation systems.
Single-supply operation simplifies portable systems, but the input and output still have absolute maximum limits that must be respected during power-up and shutdown. Use controlled supply sequencing when the source can produce transients beyond the normal input range. Verify that the common-mode input remains valid for the actual bias point; rail-to-rail output capability does not guarantee simultaneous rail-to-rail input operation.
合规信息
The manufacturer lists the AD820 as production, but exact AD820AR environmental and automotive declarations were not identified in the cited product and distributor records. Request current compliance documentation for the exact ordering code and shipment configuration.