ADM3050EBRWZ - 5.7kV Isolated CAN-FD Transceiver | Analog Devices
料号: ADM3050EBRWZ ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $5.42 | $5.42 |
| 10 | $4.88 | $48.80 |
| 100 | $4.12 | $412.00 |
| 500 | $3.65 | $1,825.00 |
| 1,000 | $3.28 | $3,280.00 |
ADM3050EBRWZ 概述
A CAN transceiver is a physical layer device that connects a CAN controller to the differential bus lines (CANH and CANL). It converts the controller's logic-level signals to differential signals for transmission and vice versa for reception. In the system hierarchy, the ADM3050E sits between the CAN controller (often integrated in a microcontroller) and the twisted-pair bus, providing galvanic isolation to protect the controller and other low-voltage circuitry from high-voltage transients and ground potential differences.
Key features include 5.7 kV rms isolation voltage, compliance with ISO 11898-2:2016, support for CAN FD data rates up to 12 Mbps, and a 5V supply voltage. The device is available in a 16-lead SOIC package (SOIC-16) and is RoHS compliant. It is designed for industrial automation, building control, and automotive applications where robust communication and isolation are critical.
Technically, the ADM3050E uses iCoupler technology to combine isolation and transceiver functions, eliminating the need for external optocouplers and separate isolated power supplies. The device provides a fully isolated solution, with isolation between the CAN controller and the physical layer bus. It features a basic feature set, focusing on essential CAN communication without additional complexity.
Typical applications include industrial fieldbus networks, motor control systems, HVAC control, and electric vehicle charging stations. The high isolation voltage and CAN FD support make it suitable for harsh environments where noise and ground loops are common.
When designing with the ADM3050E, ensure proper PCB layout with adequate creepage and clearance distances for the isolation barrier. The device requires a 5V supply on both the logic side and the bus side, and external termination resistors may be needed depending on the bus configuration.
直接替换替代料: ADM3050EBRWZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM3050EBRWZ (相同外形与封装尺寸) ——差异在于 Protocol, Supply Voltage.
快速对比工具——选择替代料号进行并排对比:
ADM3050EBRWZ-RL
✅ 直接替换📋 参考替代料(不在目录中)
ADM3050ETRWZ-EP-RL
✅ 直接替换📋 参考替代料(不在目录中)
ADM3053BRWZ
⚡ 相同封装 ⚠️ 规格未核验✓ 有现货
$3.8 / 个
查看数据手册 →ISO1042DW
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ISO1044DW
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
CTM1051KAT
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADM3050EBRWZ 规格参数
| Type | Isolated CAN Transceiver |
| Number of Drivers/Receivers | 1/1 |
| Protocol | CANbus |
| Isolation Voltage | 5.7 kV rms |
| 数据速率 | 12 Mbps (max) |
| 电源电压 | 5 V |
| 封装 | 16-SOIC (SOIC-16) |
| 安装类型 | Surface Mount |
| RoHS 状态 | Compliant |
| ISO 11898-2:2016 Compliance | Yes |
| iCoupler Technology | Yes |
| Number of Channels | 2 (isolator) |
ADM3050EBRWZ 引脚配置
| 引脚 1 | TXD — Transmit data input |
| 引脚 2 | GND1 — Logic side ground |
| 引脚 3 | VCC1 — Logic side supply voltage |
| 引脚 4 | RXD — Receive data output |
| 引脚 5 | VREF — Reference voltage output |
| 引脚 6 | CANL — Low-level CAN bus line |
| 引脚 7 | CANH — High-level CAN bus line |
| 引脚 8 | GND2 — Bus side ground |
| 引脚 9 | VCC2 — Bus side supply voltage |
| 引脚 10 | GND2 — Bus side ground |
| 引脚 11 | GND2 — Bus side ground |
| 引脚 12 | GND2 — Bus side ground |
| 引脚 13 | GND2 — Bus side ground |
| 引脚 14 | GND2 — Bus side ground |
| 引脚 15 | GND2 — Bus side ground |
| 引脚 16 | GND2 — Bus side ground |
典型应用
ADM3050EBRWZ 适用于 6 应用s: Industrial Fieldbus Networks, Motor Control Systems, Building Automation, Electric Vehicle Charging Stations, Medical Equipment, Renewable Energy Systems.
Industrial Fieldbus Networks
The ADM3050EBRWZ provides isolated CAN communication for industrial fieldbus networks, ensuring reliable data transfer in noisy environments. Its 5.7 kV rms isolation protects controllers from ground potential differences and electrical transients, while CAN FD support enables high-speed data rates up to 12 Mbps. The device is ideal for connecting PLCs, sensors, and actuators in factory automation systems, where robust communication is critical for process control and monitoring.
推荐
Motor Control Systems
In motor control applications, the ADM3050EBRWZ enables isolated CAN communication between the motor drive and the central controller. The high isolation voltage prevents high-voltage motor transients from damaging low-voltage control electronics. CAN FD support allows for fast transmission of real-time control data, improving system responsiveness. The device's robust design ensures reliable operation in harsh industrial environments with high electromagnetic interference.
推荐
Building Automation
The ADM3050EBRWZ is well-suited for building automation systems, such as HVAC control and lighting networks. Its 5.7 kV rms isolation ensures safe communication between different building zones, preventing ground loops and protecting equipment from surges. CAN FD support enables efficient data exchange for monitoring and control, while the compact SOIC-16 package allows for space-saving PCB designs. The device's compliance with ISO 11898-2:2016 ensures interoperability with standard CAN networks.
推荐
Electric Vehicle Charging Stations
The ADM3050EBRWZ is ideal for electric vehicle (EV) charging stations, where isolated CAN communication is required between the charging controller and the vehicle's battery management system. The 5.7 kV rms isolation provides safety against high-voltage transients, while CAN FD support enables high-speed data transfer for charging status and control. The device's robust design ensures reliable operation in outdoor environments with temperature variations and electrical noise.
推荐
Medical Equipment
In medical equipment, the ADM3050EBRWZ provides isolated CAN communication for patient monitoring systems and diagnostic devices. The high isolation voltage ensures patient safety by preventing electrical leakage between the device and the patient. CAN FD support allows for high-speed data transmission of vital signs and diagnostic data. The device's small footprint and low power consumption make it suitable for portable and compact medical devices.
推荐
Renewable Energy Systems
The ADM3050EBRWZ is used in renewable energy systems, such as solar inverters and wind turbines, for isolated CAN communication between power conversion stages and the central monitoring system. The 5.7 kV rms isolation protects against high-voltage transients from the power stage, while CAN FD support enables efficient data exchange for performance monitoring and fault detection. The device's wide operating temperature range and robust design ensure reliable operation in outdoor environments.
推荐
工程参考数据: ADM3050EBRWZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3050EBRWZ-RL | ADM3050ETRWZ-EP-RL | ISO1042DW |
|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Isolation Voltage | 5.7 kV rms | 5.7 kV rms | 5.7 kV rms | 5.7 kV rms |
| Data Rate | 12 Mbps | 12 Mbps | 12 Mbps | 5 Mbps |
| Supply Voltage | 5 V | 5 V | 5 V | 3.3 V or 5 V |
| CAN FD Support | Yes | Yes | Yes | Yes |
| Integrated DC-DC Converter | No | No | No | No |
关键差异点
- Higher isolation voltage than many competitors (对比 ISO1042DW)
- CAN FD support up to 12 Mbps (对比 ISO1042DW)
- iCoupler technology integration (对比 ADM3053BRWZ)
设计说明
For the ADM3050EBRWZ, ensure proper PCB layout with adequate creepage and clearance distances for the 5.7 kV rms isolation barrier. Maintain at least 8 mm creepage between the logic side and bus side to meet safety standards. Use a solid ground plane on each side of the isolation barrier and avoid routing traces across the barrier.
The ADM3050EBRWZ requires a 5V supply on both the logic side (VCC1) and the bus side (VCC2). Use separate power supplies or isolated DC-DC converters to maintain isolation. Decouple each supply pin with a 100 nF ceramic capacitor placed close to the pin, and a 10 uF bulk capacitor for transient currents.
Do not forget to connect the bus termination resistor (typically 120 ohms) at both ends of the CAN bus. The ADM3050EBRWZ does not include internal termination. Also, ensure the CANH and CANL lines are properly biased and that the bus is not left floating when the transceiver is disabled.
合规信息
RoHS compliant per distributor data. REACH and conflict minerals status not specified in provided data.