CS5460-BS - 24-Bit Power/Energy ADC | Cirrus Logic

料号: CS5460-BS ✓ 量产中
24-SSOP Package
最小起订量: 1 |

CS5460-BS 概述

Cirrus Logic Inc. CS5460-BS is a 24-bit single-input sigma-delta analog-to-digital converter designed for single-phase bi-directional power and energy measurement. It combines two delta-sigma ADCs, high-speed power-calculation functions, and a serial interface in a 24-SSOP package. Its measurement architecture supports energy, instantaneous I×V power, IRMS, VRMS, and energy-to-pulse-rate conversion for utility metering and energy-management equipment.

A sigma-delta ADC is a voltage-to-digital converter category that uses continuous-time oversampling and digital filtering to obtain high resolution from relatively low-precision internal converters. Within the broader hierarchy of data-converter ICs, ADC and DAC devices convert analog signals for digital processing, while the CS5460-BS adds specialized arithmetic for real power and energy measurements instead of serving only as a general-purpose waveform converter.

The key characteristics begin with a 24-bit conversion resolution, one analog input, and a sigma-delta architecture optimized for metering signals. The manufacturer datasheet also identifies an energy-data linearity specification of 0.1% of reading over a 1000:1 dynamic range. On-chip calculations provide energy, I×V, IRMS, VRMS, and energy-to-pulse-rate functions, reducing the amount of external signal processing required in a typical single-phase metering channel.

The CS5460 architecture is intended to support accurate single-phase, two-wire or three-wire power-metering systems. Its serial interface allows calculated measurements and status information to be transferred to a host controller, while the integrated calculation functions allow voltage and current samples to be converted into useful power quantities close to the analog input stage. This integration can simplify board partitioning and help maintain consistent measurement scaling across voltage and current channels.

Typical uses include residential electricity meters, utility revenue meters, industrial energy monitors, smart-grid endpoint equipment, and compact power-measurement modules. The device is also suited to systems that need accumulated energy as a pulse output rather than only a serial data stream. Its bi-directional measurement capability is valuable for installations where power flow can reverse, such as distributed generation or energy-storage monitoring.

The main design consideration is analog signal conditioning. Current-sensor outputs and voltage-divider signals must remain within the device's specified input range, while filtering and component selection must preserve the metering accuracy required by the end product. Follow the application circuit and component recommendations in the manufacturer datasheet, and evaluate line-voltage safety requirements independently of the integrated measurement functions.

This product page consolidates the CS5460-BS functional description, packaging information, application guidance, comparison fields, and verified substitution research. It also separates directly documented performance claims from parameters requiring an engineering review, helping designers establish the right measurement architecture before committing the 24-SSOP footprint to a PCB.

直接替换替代料: CS5460-BS ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

该产品暂无直接替换替代料。

请求替代料

CS5460-BS 最大额定值与电气特性

Device Type Single-phase bi-directional power/energy IC
ADC Resolution 24 bit
Input Count 1 input
ADC Architecture 1 sigma-delta converter
Integrated ADC Count 2 delta-sigma ADCs
On-Chip Functions Energy, I×V, IRMS, VRMS, and energy-to-pulse-rate conversion
Energy Data Linearity 0.1% of reading
Linearity Dynamic Range 1000:1
接口类型 Serial
封装 24-SSOP
Package Pin Count 24 pins
安装类型 Surface mount
Measurement Direction Bi-directional
Power Measurement Instantaneous power and energy
RMS Measurement IRMS and VRMS
Metering Compliance Reference IEC 687/1036 and JIS

CS5460-BS 24 pins 引脚配置指南

CS5460-BS(24 pins 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

CS5460-BS 的 24 pins 封装引脚图

暂无详细引脚数据: CS5460-BS.

请参阅 数据手册 以查看完整引脚配置。

典型应用

CS5460-BS 适用于 6 应用s: Residential Electricity Meter, Smart-Grid Endpoint Equipment, Industrial Energy Monitor, Distributed Generation Monitor, Energy-to-Pulse Accumulator, Compact Power-Measurement Module.

⚡

Residential Electricity Meter

The CS5460-BS is suited to single-phase residential electricity meters because its two delta-sigma ADCs and on-chip calculations provide energy, instantaneous I×V power, IRMS, and VRMS from voltage and current sensing signals. The manufacturer specifies 24-bit resolution and 0.1% energy-data linearity of reading over a 1000:1 dynamic range, allowing the meter to process a broad operating range. A host controller can read results through the serial interface, while the pulse-output function can support an energy accumulator. Final meter accuracy still depends on current-sensor and voltage-divider calibration.

🌐

Smart-Grid Endpoint Equipment

The CS5460-BS can form the measurement front end of a smart-grid endpoint that monitors single-phase load energy and communicates calculated values to a metering controller. Its integrated power, energy, and RMS calculations reduce the computational burden on the host and shorten the analog-to-digital processing path. Bidirectional operation is valuable where a customer installation can export power to the grid. Designers should match the current and voltage sensing paths to the ADC input requirements, preserve low-noise reference behavior, and follow the manufacturer calibration sequence before enabling revenue-related measurements.

🏭

Industrial Energy Monitor

For industrial equipment monitoring, the CS5460-BS provides a dedicated path for measuring real power and energy rather than relying on a general-purpose waveform ADC. Its 24-bit sigma-delta conversion, 0.1% energy-data linearity over a 1000:1 dynamic range, and integrated IRMS and VRMS calculations support compact monitoring modules. Such a module can expose live demand through its serial interface and accumulate consumption through the energy-to-pulse-rate function. Sensor selection, isolation, harmonic content, and environmental calibration determine how closely module performance approaches the component’s specified energy linearity.

🔋

Distributed Generation Monitor

The bidirectional measurement architecture of the CS5460-BS fits distributed-generation and energy-storage installations where power may flow from the load into the grid. Integrated energy, I×V, IRMS, and VRMS functions let the controller distinguish direction and magnitude using synchronized voltage and current measurements. The 24-bit sigma-delta front end and 1000:1 energy-linearity dynamic range support metering across widely changing operating conditions. For storage systems, synchronize the acquisition, define sign conventions in firmware, and validate the zero-crossing and calibration behavior across current reversal and low-power operating points.

📊

Energy-to-Pulse Accumulator

The CS5460-BS includes an energy-to-pulse-rate conversion function for meters that must drive an impulse or accumulation mechanism from calculated energy. This allows the metering IC to provide a pulse-rate representation in addition to serial data, supporting both electronic communication and pulse-based totalization. The same 24-bit conversion path and integrated energy calculation provide the underlying measurement consistency. Verify pulse scaling, output behavior, calibration coefficient, maximum pulse rate, and electrical isolation in the complete meter design rather than assuming the host performs every accumulation function.

🔧

Compact Power-Measurement Module

The CS5460-BS can serve as the core of a compact power-measurement module that accepts voltage and current signals and reports calculated electrical quantities over a serial interface. Its integration of two delta-sigma ADCs with energy, real-power, and RMS calculations reduces the number of separate analog and processing blocks required. The 24-SSOP package supports board-space savings, although careful layout remains necessary to preserve measurement performance. Module developers must document sensor excitation, gain, filtering, calibration, isolation, interface protocol, and environmental limits for downstream integrators.

What is the CS5460-BS?
The CS5460-BS is a 24-bit, single-input sigma-delta analog-to-digital converter integrated with bidirectional power and energy measurement functions. According to the Cirrus Logic manufacturer datasheet, it combines two delta-sigma ADCs, high-speed power calculations, and a serial interface. The device calculates energy, instantaneous I×V power, IRMS, VRMS, and energy-to-pulse-rate output for single-phase metering systems.
What are the key specifications of CS5460-BS that engineers should know?
The CS5460-BS combines a 24-bit resolution, one input, sigma-delta conversion, and dedicated single-phase energy-processing functions in a 24-SSOP package. The manufacturer datasheet specifies 0.1% energy-data linearity of reading over a 1000:1 dynamic range. On-chip calculations include energy, I×V, IRMS, VRMS, and energy-to-pulse-rate conversion, while a serial interface transfers results to the host controller.
Where can I download the CS5460-BS datasheet PDF?
The CS5460-BS datasheet PDF is available through the product document links on this page and through the linked Cirrus Logic document. It is the primary reference for the 24-SSOP pin description, electrical limits, calibration sequence, timing diagrams, serial interface, and application circuit. Use the pin-description table in the manufacturer datasheet when assigning PCB tracks, especially for analog inputs, supplies, and clock connections.
Where can I find the CS5460-BS pinout?
The CS5460-BS uses a 24-SSOP package, and its complete numbered pin description is found in the manufacturer datasheet. Use that table to identify analog inputs, voltage references, digital interface signals, clock connections, supplies, and ground returns before laying out the PCB. The package diagram shown with this page identifies the physical footprint, while the datasheet remains authoritative for each pin's electrical role.
What measurements does the CS5460-BS calculate?
The CS5460-BS calculates energy, instantaneous I×V power, IRMS, VRMS, and energy-to-pulse-rate values. According to the Cirrus Logic datasheet, these functions are implemented on-chip alongside two delta-sigma ADCs and a serial interface. This integration is useful for single-phase, two-wire or three-wire metering designs because the host processor can receive calculated quantities instead of implementing every real-power and RMS calculation itself.
How accurate is the CS5460-BS energy measurement?
The CS5460-BS provides an energy-data linearity of 0.1% of reading over a 1000:1 dynamic range, according to the manufacturer datasheet. That figure is a linearity specification rather than a complete statement of total end-system accuracy. Sensor errors, divider tolerances, filtering, calibration, reference quality, and PCB layout can still affect the accuracy of a finished energy meter, so validate the complete signal chain.
Is the CS5460-BS suitable for bidirectional energy metering?
Yes, the CS5460-BS is designed for single-phase bi-directional power and energy measurement. Its integrated energy and instantaneous-power calculations can support systems where energy may flow in either direction, including distributed generation and storage installations. The manufacturer also identifies the IC for two-wire and three-wire power-metering applications, but the external current and voltage paths still require application-specific design and calibration.
What is the difference between CS5460-BS and CS5460A-BSZ?
The CS5460A-BSZ belongs to the same Cirrus Logic CS5460 family and retains the 24-bit delta-sigma, dual-ADC and power-measurement positioning. However, the comparison result specifically warns that some parameters and circuit structures differ, while Cirrus Logic identifies CS5460A as discontinued. The two MPNs should therefore be treated as family members rather than automatically interchangeable; confirm pin, voltage, timing, calibration, and lifecycle requirements before substitution.
When should I choose the CS5460-BS over another power-metering ADC?
Choose the CS5460-BS when the design needs 24-bit single-phase metering with integrated energy, I×V, IRMS, VRMS, and pulse-output calculations. It is especially useful when a compact serial-interface implementation is preferred over a discrete analog front end followed by software calculations. A general-purpose high-speed ADC may suit waveform, current, or protection applications where dedicated energy arithmetic and metering accuracy are not required.
What can replace the CS5460-BS?
No pin-compatible drop-in replacement for the CS5460-BS has been established by the substitution research for this product. CS5460A-BSZ is a related family member in the same SSOP-24 format, but its circuit characteristics are not shown to be identical and its manufacturer product page is marked discontinued. Use the Request a Quote form on this page to discuss exact sourcing needs, or approve a new PCB after completing a full electrical and timing comparison.
Is there a direct cross-brand equivalent for the CS5460-BS?
No direct cross-brand, pin-to-pin equivalent for the CS5460-BS is confirmed by the current manufacturer and substitution references. Similar energy-metering ICs can differ in ADC architecture, calibration method, serial protocol, voltage reference, register map, and metering accuracy. Treat any cross-brand proposal as a functional alternative until its footprint, pin assignments, electrical limits, timing, software support, and accuracy have been independently verified.
Where can I buy the CS5460-BS and check its price?
Use the Request a Quote form on this page to request the CS5460-BS price, current stock position, minimum order quantity, and lead time. The structured price evidence for this exact MPN is empty because the available listings do not show qualifying quantity-break prices for the exact suffix. A quote request provides a current commercial response without presenting stale prices or mixing quotes from other package variants.
What is the lead time and stock status of the CS5460-BS?
The current lead time, stock quantity, and production schedule for the CS5460-BS should be confirmed through the Request a Quote form on this page. Current commercial availability can vary with the exact manufacturer, package suffix, and replenishment cycle. Request the quantity, date, and shipment condition required for your production plan, and confirm the manufacturer’s lifecycle status before committing the design to a long-life program.
Is the CS5460-BS compliant with IEC 687/1036 and JIS metering requirements?
The CS5460-BS manufacturer datasheet states that the device complies with IEC 687/1036 and JIS. Those references describe its suitability for metering applications, but component compliance does not automatically make the completed meter compliant. The external signal path, isolation strategy, accuracy calibration, firmware, test method, enclosure, and applicable national requirements must also be evaluated for the finished product.
What design considerations matter for a CS5460-BS energy-metering board?
Design the voltage and current measurement paths so their accuracy, noise, bandwidth, and overvoltage behavior support the intended metering range. Keep analog traces short, provide a stable reference and clean supply, place filtering components according to the manufacturer application circuit, and observe the layout guidance in the datasheet. Treat mains-connected circuitry as a safety-critical subsystem and apply the appropriate creepage, clearance, isolation, and surge requirements.

工程参考数据: CS5460-BS ——对比、设计指导和合规信息。

选型指南

Choose the CS5460-BS for a compact single-phase metering design that needs 24-bit sigma-delta conversion and dedicated energy, real-power, IRMS, VRMS, and pulse-rate calculations. It is especially appropriate for bidirectional residential, smart-grid, industrial-monitoring, or storage applications where a serial interface can transfer calculated results to a controller. The component is not a general waveform ADC and does not replace protection, harmonic-analysis, or high-bandwidth current-measurement devices without careful system review. CS5460A-BSZ belongs to the same broader family, but its circuit differences and discontinued status prevent treating it as a drop-in replacement. No confirmed cross-brand, pin-to-pin equivalent is identified. For any proposed substitute, require a complete comparison of pin assignment, supply voltage, ADC input range, clocking, calibration, register behavior, serial protocol, metering accuracy, lifecycle status, and software support before PCB reuse.

与替代料对比

参数 本产品
Package 24-SSOP
Brand Cirrus Logic Inc.
Device Type Single-phase bi-directional power/energy IC
ADC Resolution 24 bit
Input Count 1 input
ADC Architecture Sigma-delta; two integrated delta-sigma ADCs
Energy Data Linearity 0.1% of reading over 1000:1 dynamic range
On-Chip Calculations Energy, I×V, IRMS, VRMS, and energy-to-pulse-rate conversion
Interface Serial
Metering Standards Reference IEC 687/1036 and JIS

关键差异点

  • Dedicated energy-processing functions reduce external calculation overhead (对比 CS5460A-BSZ)
  • Wide metering operating range (对比 General-purpose 24-bit ADCs)
  • Bidirectional single-phase measurement (对比 Unidirectional energy-measurement ADCs)

设计说明

Follow the manufacturer application circuit for analog-input routing and component placement. Keep voltage and current sensing paths compact, route them away from high-current switching nodes, and use a stable reference and clean supply arrangement. Place input filtering close to the relevant pins where the datasheet layout shows it, and avoid adding long copper paths that increase noise pickup or create coupling between the voltage and current channels.

Do not treat the specified 0.1% energy-data linearity as total meter accuracy. Current-sensor offset, gain error, voltage-divider tolerance, reference variation, filter mismatch, calibration, and PCB leakage all contribute to end-product uncertainty. Establish calibration coefficients across the intended load range, verify zero-current and reversal behavior, and repeat measurements under realistic temperature and supply conditions before releasing production hardware.

Use the manufacturer’s recommended clock, reset, decoupling, filtering, and analog-input networks without substituting equivalent-looking values without checking their effects. Sigma-delta converters can support high resolution while remaining sensitive to out-of-band noise, unstable references, or poorly decoupled supply rails. Validate the implemented circuit with the specified analog bandwidth and digital interface timing rather than relying only on nominal converter resolution.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The manufacturer datasheet references IEC 687/1036 and JIS metering compliance. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not established by the cited product information.

数据核验日期: 2026-11-05 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

cs5460 brush cs5460 toothbrush cs5460 curaprox cs5460 cello cs5460 ultra soft cs5460 ortho CS5460-BS datasheet CS5460-BS datasheet pdf CS5460-BS pinout CS5460-BS equivalent CS5460-BS replacement CS5460-BS 24-SSOP CS5460-BS energy metering CS5460-BS vs CS5460A-BSZ Cirrus Logic CS5460-BS

相关元器件 & 术语

Cirrus Logic Inc. CS5460-BS CS5460A-BSZ analog-to-digital converter ADC delta-sigma ADC sigma-delta ADC power/energy IC single-phase metering bidirectional power measurement energy calculation instantaneous power IRMS VRMS energy-to-pulse-rate conversion 24-bit resolution 1000:1 dynamic range serial interface 24-SSOP SSOP package family surface-mount package IEC 687/1036 JIS smart-grid metering industrial energy monitoring
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情