INA101CM 概述

Texas Instruments INA101CM is a very-high-accuracy instrumentation amplifier for low-level differential signal amplification and general-purpose data acquisition. Its headline specifications include 25 uV maximum offset voltage, 0.25 uV/°C maximum drift, 13 nV/√Hz input noise, and a 106 dB common-mode rejection ratio at 60 Hz. The device is offered in the INA101CM configuration in a 10-pin TO-100 metal package.

An instrumentation amplifier is a specialized analog amplifier optimized for measuring small signals embedded in larger common-mode voltages. It typically combines three precision operational amplifiers with laser-trimmed metal-film resistors to provide high differential input impedance, accurate gain, and strong rejection of common-mode interference. Within the analog IC hierarchy, an instrumentation amplifier is a precision amplifier used for sensor conditioning, data acquisition, and industrial measurement systems.

The INA101CM combines three precision operational amplifiers and laser-trimmed metal-film resistors on one monolithic integrated circuit. Its maximum input offset voltage is 25 uV, while maximum input drift is 0.25 uV/°C. Low nonlinearity of 0.002% supports predictable signal transfer, and the 13 nV/√Hz noise specification makes the amplifier suitable for low-level bridge, thermocouple, and resistance-temperature-detector signals.

A common-mode rejection ratio of 106 dB at 60 Hz helps suppress mains-related interference and other signals shared equally by both inputs. The differential input resistance is approximately 10 GΩ, reducing loading on high-impedance sources. The listed operating supply range is ±5 V to ±20 V, and the typical slew rate is 0.4 V/µs. Listed bandwidth figures range from 25 kHz to 300 kHz across source descriptions, so the manufacturer datasheet should be consulted for gain-specific bandwidth limits.

Typical uses include strain-gauge bridge conditioning, thermocouple and RTD signal acquisition, industrial process measurement, medical instrumentation, and remote sensor interfaces. The device is particularly useful when a millivolt-level differential signal must be amplified while rejecting substantial common-mode voltage present in industrial wiring environments.

When designing around the INA101CM, verify the gain-set resistor values against the manufacturer gain equation and check bandwidth at the selected gain. Keep input and reference-pin traces short, use a low-noise reference when gain adjustment is required, and provide stable bypass capacitance close to the supply pins. The 10-pin TO-100 package also requires adequate lead clearance and appropriate thermal consideration at elevated ambient temperatures.

This product page combines the manufacturer electrical characteristics, package information, replacement guidance, application fit, and design considerations to support faster engineering evaluation. The INA101CM datasheet remains the controlling document for pin assignments, gain curves, absolute maximum ratings, and orderable option details.

直接替换替代料: INA101CM ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

INA101CM1

✅ 直接替换
📦 TO-100-10
Same INA101 electrical family and 10-pin TO-100 package; ordering-temperature grade differs by 0 degrees from the standard INA101CM designation.

📋 参考替代料(不在目录中)

INA101CM-BSS4

✅ 直接替换
📦 TO-100-10
Historical Burr-Brown ordering designation for the same 10-lead TO-100 INA101CM device; no electrical parameter difference is listed.

📋 参考替代料(不在目录中)

INA101CM 最大额定值与电气特性

Product Type Very-high-accuracy instrumentation amplifier
Number of Channels 1 amplifier circuit
Maximum Input Offset Voltage 25 uV
Maximum Input Offset Drift 0.25 uV/°C
Maximum Nonlinearity 0.002%
Input Noise 13 nV/√Hz
Common-Mode Rejection Ratio 106 dB at 60 Hz
Differential Input Resistance Approximately 10 GOhm
Supply Voltage Range ±5 V to ±20 V
Typical Slew Rate 0.4 V/µs
Listed Gain-Bandwidth Product 25 kHz
Listed Bandwidth 300 kHz
Maximum Power Dissipation 600 mW
Integrated Amplifier Count 3 precision operational amplifiers
Internal Resistance Type Laser-trimmed metal-film resistors
封装 10-pin TO-100
安装类型 Through-hole
Supported Package Family 14-pin plastic DIP, 16-pin ceramic DIP, and TO-100 family options

INA101CM 14-pin plastic dip, 16-pin ceramic dip, and to-100 family options 引脚配置指南

INA101CM(14-pin plastic dip, 16-pin ceramic dip, and to-100 family options 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA101CM 的 14-pin plastic dip, 16-pin ceramic dip, and to-100 family options 封装引脚图

暂无详细引脚数据: INA101CM.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA101CM 适用于 6 应用s: Strain-Gauge Bridge Conditioning, Thermocouple Measurement, RTD Sensor Interface, Remote Sensor Data Acquisition, Medical Instrumentation, Precision Laboratory Instrumentation.

🏭

Strain-Gauge Bridge Conditioning

The INA101CM fits strain-gauge bridge front ends that produce millivolt-level differential signals while the bridge common-mode voltage remains much larger. Its 25 uV maximum offset, 0.25 uV/°C maximum drift, and 106 dB common-mode rejection at 60 Hz help reduce gain error and interference from the excitation environment. Place the amplifier close to the bridge and use short, shielded differential traces to minimize pickup. The 10-pin TO-100 package requires adequate board spacing, while the ±5 V to ±20 V supply range supports common laboratory and industrial bridge excitations with appropriate headroom.

🏭

Thermocouple Measurement

The INA101CM is appropriate for low-level thermocouple acquisition because the 13 nV/√Hz input noise and 25 uV maximum offset reduce errors relative to small temperature-dependent voltages. Its 106 dB CMRR at 60 Hz is valuable when long thermocouple wires pick up power-frequency interference. Use a cold-junction compensation reference, input filtering with the correct differential resistance, and protection suitable for the measured voltage range. The ±5 V to ±20 V supply operation gives adequate output swing for many industrial thermocouple transmitters while preserving a conventional through-hole footprint.

💊

RTD Sensor Interface

The INA101CM can amplify resistance-temperature-detector signals where excitation current creates a small differential voltage across the sensor. Low offset drift of 0.25 uV/°C helps maintain accuracy as ambient temperature changes, while approximately 10 GOhm differential input resistance limits source loading. Choose a precision excitation source and ratio-reference the measurement when greater stability is required. Keep the amplifier inputs away from switching nodes and use guarded traces to reduce leakage and thermoelectric errors in precision installations.

🌐

Remote Sensor Data Acquisition

The INA101CM is useful in remote-sensor front ends where long cable runs expose the measurement to substantial common-mode noise. Its 106 dB common-mode rejection at 60 Hz attenuates shared interference, while the 10 GOhm input resistance reduces loading from high-impedance sensors. The device can amplify low-level signals before an ADC or transmitter stage, reducing the need to recover those signals digitally after substantial cable corruption. Add input protection, filtering, and a solid analog ground reference based on the installation's surge and grounding requirements.

💊

Medical Instrumentation

The INA101CM supports precision bioinstrumentation and laboratory measurement circuits that operate with small differential signals superimposed on larger common-mode voltages. Its 13 nV/√Hz noise, 25 uV maximum offset, and 0.002% maximum nonlinearity improve signal fidelity before digitization. Medical equipment designs must add the required patient protection, isolation, leakage-current control, and safety verification at the system level. The TO-100 package is useful where a through-hole, inspectable layout is preferred and the board area permits a 10-pin metal-package footprint.

🔧

Precision Laboratory Instrumentation

The INA101CM fits laboratory instruments that amplify small differential signals while rejecting common-mode noise from oscillators, transducers, or long test leads. Its 25 uV offset limit and 0.25 uV/°C drift support stable measurements over changing bench temperatures, and the 106 dB CMRR at 60 Hz improves rejection of mains-related pickup. The conventional 10-pin TO-100 package simplifies construction of modular analog front-end boards. Select the external gain resistor and bypass capacitors according to the Texas Instruments INA101 datasheet, and validate noise and settling performance for the intended measurement bandwidth.

What is the INA101CM instrumentation amplifier?
The INA101CM is a very-high-accuracy instrumentation amplifier designed for low-level differential signal amplification and general-purpose data acquisition. According to the Texas Instruments INA101 datasheet, it integrates three precision operational amplifiers and laser-trimmed metal-film resistors. The INA101CM orderable configuration uses a 10-pin TO-100 package and is intended for precision measurement and sensor-conditioning systems.
What are the key specifications of INA101CM that engineers should know?
The INA101CM provides 25 uV maximum input offset voltage, 0.25 uV/°C maximum drift, 0.002% maximum nonlinearity, and 13 nV/√Hz input noise. According to the Texas Instruments INA101 datasheet, its common-mode rejection is 106 dB at 60 Hz, its supply range is ±5 V to ±20 V, and its differential input resistance is approximately 10 GOhm. These characteristics place it in the precision instrumentation-amplifier class.
Where can I download the INA101CM datasheet PDF?
The official INA101CM datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina101.pdf. The document contains the electrical characteristics, gain relationship, application information, pin assignments, package options, and ordering information for the INA101 family. Use the INA101CM ordering row to confirm the ceramic TO-100 configuration and its temperature grade.
Where can I find the INA101CM pinout?
The INA101CM pin assignments are shown in the pin-configuration section of the Texas Instruments INA101 datasheet. The INA101CM uses a 10-pin TO-100 outline with supply, input, reference, output, and gain-resistor connections. Follow the package drawing and pin table exactly because the TO-100 lead numbering and exposed case connection must be treated as one assembly.
What is the input noise and offset voltage of INA101CM?
The INA101CM has 13 nV/√Hz input noise and 25 uV maximum input offset voltage. According to the Texas Instruments INA101 datasheet, maximum input offset drift is 0.25 uV/°C and maximum nonlinearity is 0.002%. These low-level error specifications make the amplifier appropriate for bridge sensors, thermocouples, RTDs, and other precision data-acquisition channels.
What supply voltage does the INA101CM require?
The INA101CM operates from ±5 V to ±20 V according to its manufacturer datasheet. The listed range includes dual supplies such as ±5 V, ±12 V, and ±15 V, subject to the detailed operating conditions. The device also supports single-supply operation when configured correctly, but rail headroom must be checked against input and output signal limits.
Is INA101CM suitable for strain-gauge measurements?
Yes, the INA101CM is suitable for strain-gauge bridge measurements because it combines low offset drift, low input noise, high differential input resistance, and strong common-mode rejection. According to the Texas Instruments INA101 datasheet, 0.25 uV/°C maximum drift and 106 dB CMRR at 60 Hz help preserve measurement accuracy when the bridge signal is small and the common-mode voltage is substantial.
What can replace the INA101CM?
The closest documented same-family replacements are the INA101CM1 in the 10-pin TO-100 family and the historical INA101CM-BSS4 ordering designation. Both must be checked against the required temperature grade, gain, and electrical limits before substitution. A mechanically similar instrumentation amplifier is not automatically a drop-in replacement, so verify every pin function and bias condition in the manufacturer datasheet.
Can INA101CM1 replace INA101CM without changing the PCB?
The INA101CM1 can be considered for a board-level replacement because it belongs to the same INA101 family and shares the 10-pin TO-100 package family. The important remaining check is the ordering-temperature-grade difference: confirm that INA101CM1 meets the required commercial or extended-temperature range. According to Texas Instruments ordering information, gain and electrical functions remain in the INA101 family.
What is the best Analog Devices equivalent for INA101CM?
An Analog Devices equivalent should be selected by matching the INA101CM's gain equation, 25 uV offset limit, 0.25 uV/°C drift, 106 dB CMRR, supply range, and 10-pin TO-100 pinout rather than by amplifier-family name alone. Use the Texas Instruments INA101 datasheet as the electrical baseline, then request a quote for a candidate after its manufacturer confirms pin-to-pin compatibility and operating limits.
When should I choose INA101CM over another instrumentation amplifier?
Choose the INA101CM when the design needs a legacy-compatible 10-pin TO-100 solution with 25 uV maximum offset, 13 nV/√Hz input noise, and 106 dB CMRR at 60 Hz. It is especially suitable for low-level bridge, thermocouple, RTD, and remote-sensor interfaces using dual supplies in the ±5 V to ±20 V range. Select a modern alternative instead when a smaller package, lower power, or rail-to-rail operation is more important than legacy footprint continuity.
Is INA101CM suitable for thermocouple and RTD signals?
Yes, the INA101CM is suitable for thermocouple and RTD measurement because it offers low offset voltage, low drift, low noise, and high common-mode rejection. The Texas Instruments INA101 datasheet lists both thermocouples and RTDs among the principal applications. Cold-junction compensation, reference stability, wiring protection, and input filtering must be handled by the surrounding circuit.
How much common-mode rejection does INA101CM provide?
The INA101CM provides 106 dB common-mode rejection at 60 Hz. According to the Texas Instruments INA101 datasheet, this rejection reduces the effect of equal voltages appearing on both inputs, including 60 Hz interference coupled from power or environmental wiring. CMRR remains frequency-dependent, so it should not be treated as equal to rejection at every signal frequency.
Where can I buy INA101CM online?
Use the Request a Quote form on this page to ask for INA101CM availability, order quantities, and current lead time. XAIPART can confirm the exact 10-pin TO-100 ordering code and suitable tube packaging for the production quantity. Request the current commercial terms rather than relying on an outdated catalog or unverified historical listing.
What is the price and lead time of INA101CM?
Current INA101CM price, stock status, minimum order quantity, and lead time should be requested through the Request a Quote form on this page. The exact 10-pin TO-100 orderable MPN is INA101CM, and the manufacturer datasheet confirms its family configuration. A quotation response provides the applicable quantity break, production availability, and delivery information.
Does INA101CM need a heatsink?
Thermal requirements depend on supply voltage, output swing, load current, ambient temperature, and PCB construction, so a fixed requirement cannot be assigned from the family description alone. The published maximum power dissipation is 600 mW, but that is an absolute limit rather than a recommended operating point. Calculate actual dissipation from output voltage and load current, then use the datasheet thermal information and appropriate copper area to control junction temperature.

工程参考数据: INA101CM ——对比、设计指导和合规信息。

选型指南

Choose INA101CM when maintaining a 10-pin TO-100 precision-measurement design and its electrical behavior are priorities. The combination of 25 uV maximum offset, 0.25 uV/°C maximum drift, 13 nV/√Hz noise, and 106 dB CMRR at 60 Hz is well suited to strain gauges, thermocouples, RTDs, and noisy industrial sensor interfaces. INA101CM1 is the practical same-family alternative when its ordering temperature grade satisfies the product requirements. INA101CM-BSS4 is useful when matching a historical Burr-Brown procurement or assembly record. Neither alternative should be selected solely from its suffix: confirm pinout, temperature grade, gain range, and availability in the manufacturer datasheet. If board area, power consumption, single-supply operation, or rail-to-rail output performance is the primary constraint, evaluate a modern instrumentation amplifier even if it requires a different footprint.

与替代料对比

参数 本产品 INA101CM1 INA101CM-BSS4
Package TO-100-10 TO-100-10 TO-100-10
Brand Texas Instruments Texas Instruments Texas Instruments
Product Type Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

关键差异点

  • Low offset and drift suit precision sensor measurements (对比 INA101CM-BSS4)
  • High rejection of 60 Hz common-mode interference (对比 INA101CM1)
  • Legacy-compatible through-hole footprint (对比 INA101CM1)

设计说明

Keep the INA101 input, reference, and gain-resistor connections short and away from clocks, relays, and high-current switching paths. Place input filtering capacitors at the connector or sensor side when they are required for EMI control, and use symmetric input routing to minimize conversion of common-mode interference into differential error. The approximately 10 GOhm input resistance reduces sensor loading but does not eliminate leakage caused by contaminated boards or conformal coating.

Design the supply rails so every pin remains within the manufacturer's absolute maximum limits under startup, shutdown, and fault conditions. Although the listed operating range is ±5 V to ±20 V, the usable input and output range is narrower. Place stable bypass capacitors close to the supply pins, provide adequate energy storage for transient loads, and account for the ±20 V maximum condition when selecting protection and isolation components.

Calculate INA101CM dissipation from the actual output voltage, load current, and supply configuration rather than using the 600 mW published maximum as an operating target. For a resistive load, estimated dissipation is the quiescent power plus the voltage dropped across the amplifier multiplied by load current. Use that estimate with the manufacturer thermal information and the PCB copper area to confirm that junction temperature remains below its allowed limit.

Gain accuracy depends on the external gain-setting resistor and the accuracy of the reference arrangement. Use the manufacturer gain equation to select the resistor network, avoid unnecessarily high gain when bandwidth is insufficient, and verify settling behavior for the selected gain. When using the reference input, keep it low impedance and bypass it close to the device to prevent injected noise from increasing output error.

Do not treat all INA101 package options as interchangeable: the family includes plastic and ceramic DIP variants as well as TO-100 packages. Confirm the exact INA101CM orderable suffix, lead numbering, temperature grade, and pin functions before changing an existing design. Also check whether the source material's bandwidth description applies to a different gain condition rather than comparing a broad family figure directly with a required small-signal bandwidth.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Use the manufacturer product page and datasheet for current environmental, material, and automotive qualification statements.

相关搜索

ina101 datasheet INA101CM datasheet INA101CM datasheet pdf INA101CM pinout INA101CM specifications INA101CM TO-100-10 INA101CM offset voltage INA101CM input noise INA101CM strain gauge amplifier INA101CM thermocouple interface INA101CM drop-in replacement INA101CM equivalent INA101CM vs INA101CM1 INA101CM price Texas Instruments INA101CM

相关元器件 & 术语

Texas Instruments INA101CM INA101CM1 INA101CM-BSS4 instrumentation amplifier precision amplifier operational amplifier analog integrated circuit semiconductor differential input common-mode rejection ratio CMRR input offset voltage input offset drift input noise nonlinearity strain gauge thermocouple resistance temperature detector RTD data acquisition TO-100-10 TO-100 package family through-hole package surface mount RoHS REACH AEC-Q100
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情