Texas Instruments

INA101SM - High Accuracy Instrumentation Amplifier | TI

料号: INA101SM ✗ 停产
25 uV max Vdss TO-100-10, through-hole Package
最小起订量: 1 |

INA101SM 概述

The Texas Instruments INA101SM is a very high accuracy instrumentation amplifier for low-level signal amplification and general-purpose data acquisition, packaged in a 10-pin TO-100 package. It integrates three precision operational amplifiers and laser-trimmed metal-film resistors on one monolithic IC. The verified data identifies a maximum input offset voltage of 25 uV, maximum input drift of 0.25 uV/°C, low nonlinearity of 0.002%, and input-referred noise of 13 nV/√Hz. These characteristics make the device suitable for precision bridge, strain-gauge, sensor, and biomedical signal-chain designs where offset and drift errors must remain small relative to the measured signal.

An instrumentation amplifier is a specialized differential amplifier optimized for measuring small signals superimposed on a large common-mode voltage. Its internal gain-setting network and three-op-amp architecture provide high input impedance, controlled gain, and strong common-mode rejection. In the broader semiconductor hierarchy, an instrumentation amplifier is an analog signal-conditioning amplifier, a linear amplifier, and ultimately an integrated circuit used within data-acquisition and measurement systems. The INA101 is intended to preserve signal integrity from sensor excitation through differential amplification.

Key features include a 13 nV/√Hz noise density, 25 uV maximum offset voltage, 0.25 uV/°C maximum drift, and 0.002% low nonlinearity. Its integrated precision resistors reduce external gain-setting components and help establish repeatable performance between assemblies. The high input impedance prevents the amplifier from significantly loading the source, while common-mode rejection is important when the wanted differential signal is much smaller than the voltage shared by both input terminals.

The verified data describes the INA101 as a monolithic integrated circuit combining three precision op amps with laser-trimmed metal-film resistors. The design is suited to precision amplification of differential inputs rather than single-ended audio or general logic signals. Comparison information identifies a typical dual-supply condition of ±15 V, with an indicated minimum of ±5 V and maximum of ±20 V; maximum power dissipation is listed as 600 mW. These operating details must be checked against the complete manufacturer datasheet for design limits and test conditions.

Typical applications include strain-gauge bridge excitation and measurement, low-level sensor acquisition, biomedical instrumentation, and general-purpose differential data acquisition. In a bridge circuit, the small millivolt-level differential output can be amplified while the instrumentation amplifier rejects common-mode excitation and prevents source loading. In biomedical or industrial measurement systems, the combination of low offset, low drift, and high input impedance helps preserve measurements over time and across varying source impedances.

Designers should confirm the exact pin assignments, gain configuration, supply sequencing, common-mode range, and output-swing limits in the manufacturer datasheet before layout. Because this through-hole TO-100 device can dissipate up to 600 mW according to the verified comparison data, adequate PCB copper and thermal spacing should be provided. Input and reference-ground connections should be kept short, and the gain-setting method should follow the datasheet's recommended resistor topology.

This page combines verified manufacturer and distributor information, source traceability, application guidance, and a disciplined alternative assessment. The available cross-reference results did not establish five verified, pin-compatible drop-in parts in the same package, so no unsupported replacements are presented as drop-in equivalents.

直接替换替代料: INA101SM ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: INA101SM (相同外形与封装尺寸) ——差异在于 Package, Product Type.

Texas Instruments
Package: TO-100-10
Product Type: Instrumentation Amplifier
对比 INA101SM →

该产品暂无直接替换替代料。

请求替代料

INA101SM 最大额定值与电气特性

Product Type Very high accuracy instrumentation amplifier
Number of Circuits 1 circuit
Internal Architecture 3 precision operational amplifiers with laser-trimmed metal-film resistors
Maximum Input Offset Voltage 25 uV max
Maximum Input Drift 0.25 uV/°C max
Low Nonlinearity 0.002%
Input Noise Density 13 nV/√Hz
High Common-Mode Rejection Specified at 60 Hz
High Input Impedance 10^10 ohm
Minimum Dual Supply Voltage ±5 V
Typical Dual Supply Voltage ±15 V
Maximum Dual Supply Voltage ±20 V
Maximum Power Dissipation 600 mW
封装 TO-100-10, through-hole
Process Technology Monolithic integrated circuit
安装类型 Through-hole

INA101SM to-100-10, through-hole 引脚配置指南

INA101SM(to-100-10, through-hole 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA101SM 的 to-100-10, through-hole 封装引脚图

暂无详细引脚数据: INA101SM.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA101SM 适用于 6 应用s: Strain-Gauge Bridge Measurement, Precision Sensor Signal Conditioning, Biomedical Instrumentation, General-Purpose Data Acquisition, Industrial Process Monitoring, Precision Low-Noise Analog Front End.

🏭

Strain-Gauge Bridge Measurement

The INA101SM fits strain-gauge bridge measurement because its 25 uV maximum offset voltage, 0.25 uV/°C maximum drift, and 13 nV/√Hz noise density help preserve the small differential signal produced by a resistive bridge. Its high input impedance also reduces loading of the bridge and sensor network. The device is placed between the bridge output and the next stage of the measurement chain, with gain and common-mode limits selected from the official datasheet. Practical accuracy depends on bridge excitation stability, source impedance matching, clean reference grounding, and keeping sensitive input routing short.

🧩

Precision Sensor Signal Conditioning

The INA101SM is suitable for conditioning low-level differential outputs from precision sensors when measurement integrity is more important than compactness. Its verified high input impedance of 10^10 ohm limits source loading, while low offset and drift reduce errors that could dominate a slow or high-resolution measurement. The instrumentation amplifier sits at the sensor interface and amplifies the differential signal before conversion or processing. Designers should verify the allowable input common-mode range and output swing against the selected gain, because those operating limits were not included in the supplied excerpts.

💊

Biomedical Instrumentation

The INA101SM can support biomedical instrumentation front ends where small physiological or diagnostic signals must be amplified without excessive input loading. Its 25 uV maximum offset, 0.25 uV/°C maximum drift, and 13 nV/√Hz noise density provide a useful accuracy baseline for low-level amplifier stages. In an ECG, bridge, or sensor interface, the INA101SM would amplify the differential input while rejecting common-mode voltage. Actual suitability for a medical product also depends on patient protection, isolation, leakage, regulatory validation, and application-specific safety requirements.

🖥️

General-Purpose Data Acquisition

The INA101SM is appropriate for general-purpose data acquisition systems that need accurate differential amplification rather than a single-ended amplifier. Its monolithic integration of three precision operational amplifiers and laser-trimmed metal-film resistors provides a consistent signal-conditioning core for multiplexed or dedicated analog channels. The device can sit close to the sensor or connector to minimize interference and reduce cable-induced errors. System designers should still implement suitable input filtering, reference grounding, supply decoupling, and gain selection based on the full manufacturer application guidance.

🏭

Industrial Process Monitoring

The INA101SM is suitable for industrial process monitoring when the measured differential signal is small and rides on a substantial common-mode voltage. The specified high common-mode rejection at 60 Hz helps distinguish the wanted bridge or sensor output from shared industrial noise, while the high input impedance reduces interaction with field-mounted transducers. The amplifier can condition a low-level process signal ahead of an ADC or control input. Its ±5 V to ±20 V indicated dual-supply span should be reconciled with field power availability and grounded-versus-bipolar input architecture before deployment.

⚡

Precision Low-Noise Analog Front End

The INA101SM can serve as the precision gain stage in a low-noise analog front end when a 13 nV/√Hz input noise density and 25 uV maximum offset are useful starting points. Its high input impedance allows the source to remain lightly loaded, while the differential architecture is suited to signals that require common-mode rejection. The component should be placed near the source, with short inputs, a stable reference, and grounding arranged to prevent injected current from becoming differential error. Bandwidth, settling behavior, and gain-programming details must be obtained from the manufacturer datasheet.

推荐产品汇总

INA101CM Same INA101-family instrumentation amplifier with a different package 用于: Strain-Gauge Bridge Measurement, Biomedical Instrumentation INA104SMQ Related INA10x-family instrumentation amplifier for comparison 用于: Precision Sensor Signal Conditioning, General-Purpose Data Acquisition, Precision Low-Noise Analog Front End INA101HP Texas Instruments 用于: Industrial Process Monitoring
What is the INA101SM instrumentation amplifier?
The INA101SM is a very high accuracy, single-channel instrumentation amplifier from Texas Instruments for low-level differential signal amplification and general-purpose data acquisition. According to the Texas Instruments datasheet, it combines three precision operational amplifiers and laser-trimmed metal-film resistors in one monolithic integrated circuit. The specified performance includes 25 uV maximum input offset voltage, 0.25 uV/°C maximum drift, 0.002% low nonlinearity, and 13 nV/√Hz noise density.
What are the key specifications of INA101SM that engineers should know?
The INA101SM combines a 25 uV maximum input offset voltage, 0.25 uV/°C maximum drift, 0.002% low nonlinearity, and 13 nV/√Hz input noise density. The verified comparison information also indicates a typical ±15 V dual supply, an indicated range from ±5 V to ±20 V, high input impedance of 10^10 ohm, and maximum power dissipation of 600 mW. Texas Instruments identifies it as a monolithic device integrating three precision op amps and laser-trimmed metal-film resistors.
Where can I download the INA101SM datasheet PDF?
The official INA101SM datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina101.pdf. The manufacturer page at https://www.ti.com/product/INA101 provides ordering, quality, and additional product information. The datasheet is the authoritative source for the complete pinout, gain equation, supply restrictions, common-mode range, output swing, thermal limits, and application circuit because those details were not included in the supplied search excerpts.
Where can I find the INA101SM pinout?
The INA101SM pinout should be obtained from the pin configuration section of the official Texas Instruments INA101 datasheet at https://www.ti.com/lit/ds/symlink/ina101.pdf. The verified listing identifies the package as TO-100-10, but the supplied excerpts do not contain individual pin numbers or names. Consequently, this record does not reproduce an inferred pinout and lists the pinout as null to avoid presenting unverified pin assignments as authoritative.
How much does INA101SM cost?
The verified LCSC listing quotes an INA101SM price of $25.0438 as of 2026-10-30. The supplied web data does not provide quantity-tiered prices, so the displayed tiers repeat that single verified unit price rather than invent discount levels. Actual purchase cost can vary with inventory, quantity, shipping, and authorized-distributor terms. Compare the manufacturer product page and current distributor quotations before committing a production BOM.
Where can I buy INA101SM online?
You can buy INA101SM through the verified Texas Instruments product page and distributor listings, including DigiKey, Mouser, LCSC, and WIN SOURCE. The LCSC result lists the part as in stock and quotes $25.0438 as of 2026-10-30, while DigiKey describes the device as available to buy and ship. Availability can change rapidly, so confirm live stock, authorized status, quantity breaks, and date code at the distributor before placing an order.
What is the lead time for INA101SM?
The INA101SM lead time is not stated in the supplied verified web data. DigiKey's listing says the part can be bought and shipped, and LCSC identifies it as in stock, but those statements do not provide a contractual manufacturing lead time. For procurement, request a written quotation and scheduled delivery date for the required quantity. A distributor stock statement should not be interpreted as a guaranteed production allocation.
Is INA101SM in stock?
Yes, the supplied LCSC listing identifies the INA101SM as in stock and quotes $25.0438 as of 2026-10-30. DigiKey also presents a buy-and-ship listing for the device. Inventory is a time-sensitive commercial condition rather than a permanent technical property, so confirm the available quantity and lead time directly with the seller before ordering.
INA101SM versus INA101CM: which is better for a precision bridge?
Choose the INA101SM when its verified TO-100-10 package is required, and consider the INA101CM when its different package is acceptable. The supplied comparison identifies INA101CM as another INA101-family device, but it does not establish that the two are pin-to-pin compatible because the package suffixes differ. Confirm gain configuration, supply range, pinout, and thermal requirements in the datasheet before treating either part as an interchangeable alternative.
What is the difference between INA101SM and INA104SMQ?
The available comparison result places INA101SM and INA104SMQ in the same INA10x instrumentation-amplifier family, but it does not provide a complete parameter table or explicit pin-compatibility statement. The INA101 is described by Texas Instruments as a very high accuracy general-purpose instrumentation amplifier, while the INA104SMQ designation indicates a different family member with the SM ordering suffix. Verify package pinout, gain range, input and output limits, and offset performance before substitution.
When should I choose INA101SM over an alternative instrumentation amplifier?
Choose the INA101SM when a TO-100-10 through-hole package, very high accuracy, and the verified 25 uV maximum offset specification are priorities. Its monolithic integration of three precision op amps and laser-trimmed metal-film resistors can simplify precision analog layouts. Select an alternative only after confirming pin compatibility, gain equation, supply range, common-mode input range, output swing, bandwidth, and thermal performance; the supplied data does not establish a fully qualified drop-in replacement.
Is INA101SM suitable for strain-gauge and sensor measurement?
Yes, the INA101SM is suitable for low-level strain-gauge and sensor measurement because it combines high input impedance, low 25 uV maximum offset voltage, 0.25 uV/°C maximum drift, and 13 nV/√Hz noise density. The Texas Instruments applications information identifies strain measurement as an intended use. Actual accuracy still depends on bridge excitation, source resistance, gain, reference quality, common-mode range, and PCB cleanliness.
What can replace INA101SM?
No replacement is confirmed here as a fully verified, pin-compatible drop-in substitute for the INA101SM. The supplied cross-reference material identifies INA104SMQ as a related same-family comparison and INA101HP as a functionally similar component, but it does not provide the package, pinout, and complete parametric evidence required for drop-in qualification. Check Texas Instruments' cross-reference search and current manufacturer documentation before changing the BOM.
Is the INA101SM the same as an Analog Devices equivalent?
The supplied evidence does not establish a pin-compatible Analog Devices replacement for the INA101SM. The cross-reference search results include a generic Analog Devices reference page, but they do not identify a specific part with a verified TO-100-10 footprint and matching pin functions. A cross-brand candidate should be accepted only after its datasheet confirms the same pinout, gain configuration, supply limits, common-mode range, output swing, accuracy, and thermal performance.
Does INA101SM need external gain-setting resistors?
The exact gain-setting method is not specified in the supplied web excerpts, so it must be confirmed in the official INA101 datasheet. The manufacturer describes laser-trimmed metal-film resistors integrated on the monolithic IC, while also offering a SO-16 package and multiple fixed-gain options according to the device information. Do not assume an external gain equation or resistor values without checking the ordering-option table and gain-setting section.

工程参考数据: INA101SM ——对比、设计指导和合规信息。

选型指南

Choose the INA101SM when your design requires a TO-100-10 through-hole instrumentation amplifier and can benefit from the verified 25 uV maximum offset voltage, 0.25 uV/°C maximum drift, 13 nV/√Hz noise density, and 10^10 ohm input impedance. It is a strong fit for precision bridges, strain gauges, low-level sensors, biomedical interfaces, and industrial acquisition systems that can tolerate a larger package. Consider the INA101CM when its different package and verified electrical characteristics better match the design, but do not treat it as pin-compatible without checking the datasheet. INA104SMQ and INA101HP are related candidates worth evaluating, yet the supplied evidence does not establish complete drop-in equivalence. Before ordering an alternative, compare pin functions, gain method, common-mode range, output swing, bandwidth, supply requirements, offset, drift, noise, thermal rating, lifecycle status, and current price.

与替代料对比

参数 本产品 INA104SMQ
Product Type Very high accuracy instrumentation amplifier Instrumentation amplifier
Brand Texas Instruments Texas Instruments

关键差异点

  • Verified precision offset specification (对比 INA104SMQ)
  • Low-drift monolithic implementation (对比 INA101HP)
  • High-impedance differential input stage (对比 INA101CM)

设计说明

Place the INA101SM close to the sensor or bridge output and keep the two input traces short, symmetric, and away from switching nodes. The verified high input impedance of 10^10 ohm reduces DC loading, but it does not eliminate AC or capacitive loading. Use a continuous ground plane where practical, keep input returns away from high-current paths, and avoid adding unnecessary copper or test-point capacitance around sensitive inputs.

Use the official datasheet to confirm the required supply arrangement, gain-dependent common-mode limits, and output swing before connecting the device. The supplied comparison data indicates operation from ±5 V to ±20 V with ±15 V typical. Decouple supply pins close to the component using the manufacturer-recommended network, and ensure that input common-mode voltage and output voltage remain within limits for the selected gain rather than relying only on the absolute supply ratings.

The verified comparison information lists maximum power dissipation as 600 mW. At elevated ambient temperature, provide copper area around the TO-100-10 package and avoid placing heat sources directly beneath it. Confirm the official maximum junction and case temperatures before calculating copper requirements. Because the exact thermal resistance depends on the PCB and manufacturer test conditions, use the datasheet value rather than an assumed thermal model.

Do not infer pin functions, gain equations, or the relation between INA101SM and INA101CM from their similar names. The verified excerpts identify INA101SM as TO-100-10 while INA101CM uses a different ordering suffix, so a footprint-compatible replacement has not been established. Similarly, INA104SMQ is only a related comparison candidate until its pinout, gain network, supply limits, and accuracy parameters are verified from its datasheet.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied verified web data does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for INA101SM. These fields remain unknown rather than being inferred from the package or manufacturer.

相关搜索

INA101SM INA101SM datasheet Texas Instruments INA101SM INA101SM TO-100-10 instrumentation amplifier INA101SM 25 uV offset voltage INA101SM 13 nV/Hz noise density INA101SM strain gauge amplifier INA101SM biomedical signal conditioning INA101SM vs INA101CM INA101SM vs INA104SMQ INA101SM drop-in replacement INA101SM buy price INA101SM pinout what is the lead time for INA101SM

相关元器件 & 术语

Texas Instruments INA101SM INA101CM INA101HP INA104SMQ instrumentation amplifier differential amplifier analog signal conditioner integrated circuit precision operational amplifier monolithic integrated circuit laser-trimmed metal-film resistor input offset voltage input drift input noise density common-mode rejection high input impedance TO-100-10 through-hole package strain-gauge bridge biomedical instrumentation industrial process monitoring data acquisition power dissipation
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情