INA126UA/2K5 - Instrumentation Amplifier | Texas Instruments
料号: INA126UA/2K5 ✓ 量产中INA126UA/2K5 概述
An instrumentation amplifier is a specialized amplifier category designed to reject common-mode interference while amplifying a differential input. This makes the INA126 family suitable for bridge sensors, strain gauges, pressure transducers, thermocouple interfaces, current-sense measurements, and other instrumentation circuits where the signal source is small and the surrounding environment contains noise. The differential input architecture helps preserve sensor signal integrity when both input terminals are exposed to a substantial common-mode voltage.
The INA126UA/2K5 is identified as a UA-packaged instrument-amplifier product. The exact package dimensions, exposed-pad arrangement, electrical limits, supply range, input common-mode range, gain accuracy, noise specifications, and environmental ratings must be confirmed from the manufacturer datasheet before final PCB release or production qualification. Engineers should also verify the gain-setting network and reference configuration used by the selected circuit topology.
Because the part is intended for precision measurement rather than high-current or high-power conversion, its layout priorities are input symmetry, resistor matching, reference stability, clean grounding, and isolation from switching nodes. Place input and feedback components close to the device, use a low-noise reference network, and route high-current return paths away from the input terminals. The analog supply should be filtered close to the device, while the ground plane should remain continuous beneath the measurement circuitry.
The INA126UA/2K5 is useful when a low-level differential measurement must be conditioned with a defined gain and low common-mode sensitivity. It can serve industrial process monitoring, portable instrumentation, laboratory measurement equipment, and embedded sensor interfaces. Selection between exact gain versions, different packages, and competing instrumentation amplifiers should be based on the required gain, input range, noise, bandwidth, supply voltage, reference implementation, and mechanical footprint.
直接替换替代料: INA126UA/2K5 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA126UA/2K5 (相同外形与封装尺寸) ——差异在于 Package, Signal Type.
INA126UA/1K
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA126UA/10K
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA126UA/20K
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA126UA/100K
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA126UA/200K
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA126UA/2K5 最大额定值与电气特性
| Gain Setting | 2.5 kOhm nominal suffix designation |
INA126UA/2K5 standard 引脚配置指南
INA126UA/2K5(standard 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA126UA/2K5.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA126UA/2K5 适用于 6 应用s: Bridge-Based Pressure Sensing, Strain Gauge Instrumentation, Low-Level Industrial Sensor Interface, Battery-Powered Portable Instrument, Medical Signal Conditioning, Laboratory Data Acquisition.
Bridge-Based Pressure Sensing
The INA126UA/2K5 fits a precision bridge-measurement front end when a small differential sensor voltage must be amplified before ADC conversion. The 2.5 kOhm nominal gain setting gives the system a defined relationship between bridge excitation and measured output while the instrumentation-amplifier topology reduces sensitivity to common-mode voltage. In practice, use the device between the bridge and the analog-to-digital converter, keep the bridge excitation and analog supply rails clean, and verify the output-swing limits against the bridge’s maximum differential output. Component placement should preserve symmetry between the two sensor inputs, and the reference network should be selected only after confirming the required gain and output range in the manufacturer application circuit.
推荐
Strain Gauge Instrumentation
A strain gauge produces a small differential voltage when mechanically stressed, making the INA126UA/2K5 appropriate as the analog gain stage in a strain-measurement channel. The nominal 2.5 kOhm gain helps convert the millivolt-level gauge response into a more practical ADC input range, while the differential input arrangement helps reject voltage shared by both gauge terminals. The bridge should use a stable excitation source, the amplifier should be positioned close to the gauge connector, and the complete chain must be calibrated for gain error, offset, and temperature drift. Verify the maximum bridge imbalance and output swing so that the amplifier remains within its specified linear operating region during overload or sensor fault conditions.
推荐
Low-Level Industrial Sensor Interface
The INA126UA/2K5 can condition low-level differential outputs from industrial sensors that operate alongside high common-mode voltage. Its instrumentation-amplifier function is useful when a sensor output is referenced to ground but shares substantial supply-related voltage with the measurement electronics. Place the amplifier near the sensor connector to minimize pickup of electromagnetic noise, use a shielded or protected routing strategy, and decouple the analog supply locally. The 2.5 kOhm nominal gain should be included in the scaling calculation for the downstream converter, while the design must separately verify input common-mode range, output swing, noise performance, and the required industrial temperature range.
推荐
Battery-Powered Portable Instrument
The INA126UA/2K5 is relevant to portable measurement equipment that operates from a limited battery supply and must amplify a small sensor signal without introducing excessive board area. The UA family package supports a compact analog front end, but the final power budget depends on the confirmed supply voltage and quiescent-current specifications. Use low-leakage input and reference components, avoid unnecessary analog circuitry, and connect the converter’s output and reference network close to the device. The 2.5 kOhm nominal gain can improve use of the ADC range for weak signals, yet the engineer should account for shutdown behavior, startup settling, noise, and the converter’s input range. A low-power architecture is only appropriate after confirming the device’s operating limits from the manufacturer datasheet.
推荐
Medical Signal Conditioning
The INA126UA/2K5 can serve as an analog conditioning element in a medical instrumentation design when the selected system architecture requires differential amplification of a low-level biological or electrode-derived signal. The nominal 2.5 kOhm gain setting must be reconciled with the front-end protection network, patient-input isolation requirements, ADC input range, and applicable medical safety process. Place input protection components where their capacitance and leakage do not compromise the intended signal bandwidth, maintain high-impedance guarding around sensitive nodes, and separate analog and digital return currents. Confirm noise, offset, common-mode rejection, supply limits, and package construction directly from the manufacturer documentation before using this device in a medical design.
推荐
Laboratory Data Acquisition
The INA126UA/2K5 is suitable for laboratory-style data-acquisition channels that require differential input handling and adjustable signal scaling. The 2.5 kOhm nominal gain provides a defined starting point for moderate-level transducer signals, allowing the downstream ADC to receive a more useful voltage range than the raw sensor output. Keep the analog input stage close to the transducer connector, use a stable reference arrangement, and provide local supply bypassing to reduce measurement noise. For multi-channel systems, avoid sharing sensitive return paths with relay coils, motor drivers, or switching supplies. Confirm bandwidth, settling behavior, output drive, offset, and calibration requirements so the complete acquisition chain meets the intended measurement uncertainty.
推荐
推荐产品汇总
工程参考数据: INA126UA/2K5 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA126UA/1K | INA126UA/10K | INA126UA/20K | INA126UA/100K | INA126UA/200K |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | UA | UA | UA | UA | UA | UA |
| Nominal Gain | 2.5 kOhm suffix designation | 1 kOhm suffix designation | 10 kOhm suffix designation | 20 kOhm suffix designation | 100 kOhm suffix designation | 200 kOhm suffix designation |
| Amplifier Function | Instrumentation amplifier | Instrumentation amplifier family version | Instrumentation amplifier family version | Instrumentation amplifier family version | Instrumentation amplifier family version | Instrumentation amplifier family version |
| Input Topology | Differential | Differential family architecture | Differential family architecture | Differential family architecture | Differential family architecture | Differential family architecture |
关键差异点
- Nominal 2.5 kOhm gain option (对比 INA126UA/1K)
- Lower gain than the 10 kOhm family option (对比 INA126UA/10K)
- Resolution between lower and higher INA126UA gain variants (对比 INA126UA/20K)
设计说明
Keep the INA126UA/2K5 input traces, gain-setting components, and reference components close to the device. Route the two input paths symmetrically and avoid placing sensitive traces beneath switching-regulator nodes, relay contacts, or high-current return paths. Confirm the manufacturer recommended layout and use a continuous ground plane for the analog section.
Decouple each supply connection locally with the capacitance and ESR requirements specified by the manufacturer datasheet. Place the bypass components on the same side of the PCB as the device and connect them with short, low-inductance paths. Confirm the complete input voltage, ground, output swing, and supply sequencing requirements before applying power.
Treat the sensor connection as a high-impedance precision input. Minimize connector-to-amplifier distance, use guarded or shielded routing where appropriate, and keep the reference network away from noisy switching nodes. Recheck the 2.5 kOhm nominal gain against the sensor excitation, ADC input range, and calibration plan.
Do not select a replacement solely because it uses the same UA package. The INA126UA gain options differ in nominal amplification, so changing the suffix can alter output range, sensitivity, noise behavior, and calibration. Verify pin functions, supply compatibility, common-mode limits, reference configuration, and PCB dimensions before substituting a part.
合规信息
Compliance information requires confirmation from the current manufacturer product documentation or the supplier declaration.