Texas Instruments

INA2126P - Dual 36V Micropower Instrumentation Amplifier | Texas Instruments

料号: INA2126P ✓ 量产中
36 V Vdss 175 µA/channel Id 16-PDIP Package
最小起订量: 1 |

INA2126P 概述

The Texas Instruments INA2126P is a dual-channel, micropower precision instrumentation amplifier designed for accurate differential-signal acquisition. Each channel uses a two-op-amp architecture and consumes 175 µA of quiescent current, while the device operates from ±1.35 V to ±18 V, equivalent to a 36 V maximum total supply range. The INA2126P provides 250 µV offset performance and is supplied in a 16-pin PDIP package for through-hole PCB designs.

An instrumentation amplifier is a specialized analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. The INA2126 family belongs to the instrumentation amplifier hierarchy, which includes differential amplifiers, low-noise analog amplifiers, and broader analog signal-chain ICs. Its differential-input architecture makes it suitable for sensor signals, bridge outputs, and other small-signal measurements where the wanted signal is small relative to an imposed common-mode voltage.

The principal features of the INA2126P are its dual-channel configuration, 175 µA per channel quiescent current, 250 µV offset specification, and wide ±1.35 V to ±18 V operating range. Micropower consumption reduces the burden on portable and battery-powered systems, while the wide supply range supports both low-voltage portable instrumentation and higher-voltage industrial measurement systems. The differential architecture also helps preserve signal integrity when the input common-mode voltage is substantially larger than the differential signal being measured.

The INA2126 family uses a two-op-amp instrumentation-amplifier topology to provide differential amplification with high input impedance and common-mode rejection. Because the device is intended for precision acquisition rather than high-bandwidth signal processing, designers should use the manufacturer-recommended gain-setting resistor and follow the datasheet layout guidance to minimize gain error and offset contributions. The 16-pin PDIP package favors through-hole prototyping, laboratory instrumentation, and industrial control boards where a surface-mount package is not required.

Typical applications include portable sensor acquisition, strain-gauge and bridge excitation systems, battery-powered measurement equipment, industrial process monitoring, medical instrumentation, and low-power data-acquisition systems. In each case, the INA2126P provides a practical way to amplify a differential sensor signal while keeping channel quiescent current at 175 µA. Designers should confirm that input common-mode voltage, output swing, gain, bandwidth, and supply limits satisfy the specific measurement requirements.

The primary design consideration is ensuring adequate output headroom and checking the gain-dependent bandwidth and input range. The 250 µV offset specification supports precise measurements, but resistor matching and layout still influence overall system accuracy. Input filtering and guarding can reduce high-frequency interference, while stable reference and excitation arrangements are important for bridge-based sensors.

This product page combines the verified Texas Instruments product information, distributor availability references, pricing context, package details, and engineering selection guidance to provide a practical comparison point for engineers evaluating the INA2126P.

直接替换替代料: INA2126P ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: INA2126P (相同外形与封装尺寸) ——差异在于 Mounting Type, Package.

Texas Instruments
Mounting Type: Surface mount
Package: 16-pin SOIC
对比 INA2126P →

INA2126PA

✅ 直接替换
📦 16-PDIP
Suffix-specific grade or ordering characteristics are not exposed in the verified snippet; package and dual-channel architecture match

📋 参考替代料(不在目录中)

INA2126P 最大额定值与电气特性

Number of Channels 2 channels
Architecture Two-op-amp instrumentation amplifier
Maximum Supply Voltage 36 V
Operating Voltage Range ±1.35 V to ±18 V
静态电流 175 µA/channel
Offset Voltage 250 µV
Input Type Differential
Application Low-noise differential-signal acquisition
Circuit Count 2 circuits
封装 16-PDIP
安装类型 Through-hole
Packaging Tube
Product Type Precision instrumentation amplifier
电源电流 350 µA for two channels

INA2126P 16-pdip 引脚配置指南

INA2126P(16-pdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA2126P 的 16-pdip 封装引脚图

暂无详细引脚数据: INA2126P.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA2126P 适用于 6 应用s: Portable Sensor Signal Acquisition, Strain-Gauge Bridge Measurement, Battery-Powered Data Acquisition, Industrial Process Monitoring, Medical Instrument Front End, Low-Noise Sensor Interface.

📱

Portable Sensor Signal Acquisition

The INA2126P fits portable sensor acquisition because each channel consumes 175 µA of quiescent current and supports a ±1.35 V to ±18 V operating range. It can condition a low-level differential sensor output while rejecting common-mode disturbance coupled into both sensor lines. Place the amplifier close to the sensor interface, use the manufacturer-recommended gain resistor, and keep the input loop small to preserve low-noise performance. The principal trade-off is that micropower operation does not eliminate the need to verify gain-dependent bandwidth, input common-mode range, and output swing.

🏭

Strain-Gauge Bridge Measurement

The INA2126P is appropriate for strain-gauge bridge sensing because its precision differential input stage can amplify the small bridge imbalance while rejecting much of the common excitation voltage. The 250 µV offset specification is particularly relevant when the bridge output is close to zero, and the 175 µA per channel supply current suits compact measurement systems. Use a stable excitation source, confirm that excitation and input common-mode voltages remain inside the device limits, and follow the datasheet gain-resistor guidance. Overall accuracy will also depend on bridge tolerance and temperature drift.

🔧

Battery-Powered Data Acquisition

The INA2126P supports battery-powered data acquisition because its dual-channel architecture limits quiescent supply demand to 175 µA per active channel. Its differential inputs are useful for measuring sensor pairs while suppressing common-mode noise from long cables or shared grounds. The device can operate from low-voltage supplies within the specified ±1.35 V to ±18 V range. Designers should budget for sensor current, gain-setting-resistor current, reference circuits, and ADC leakage, and should verify whether the selected gain provides sufficient bandwidth for the required conversion rate.

🏭

Industrial Process Monitoring

The INA2126P is suitable for industrial process monitoring when low-level differential signals must be amplified before conversion by an ADC. Its 36 V maximum total supply range supports headroom above the stated ±18 V operating limit, while 175 µA per channel reduces self-heating and system power demand. Input protection, filtering, and grounding remain essential in industrial environments. Confirm the operating-temperature grade, common-mode range, output swing, and gain error from the complete manufacturer documentation before deploying it in a high-temperature or high-noise enclosure.

💊

Medical Instrument Front End

The INA2126P can serve as a front-end stage in low-level medical instrumentation when the selected channel meets the required safety, temperature, and accuracy criteria. Differential amplification helps reject common-mode interference, while the 250 µV offset rating is valuable for signals near zero. The dual-channel architecture can process two related sensor outputs, such as differential sensing and a reference channel. Engineers must still add suitable input protection and isolation where required, verify medical-specific qualification requirements, and prevent patient-connected circuits from exceeding the absolute maximum ratings.

📡

Low-Noise Sensor Interface

The INA2126P fits a low-noise sensor interface where a small differential voltage must be amplified without adding excessive supply current. Its 175 µA per channel quiescent current limits the amplifier’s contribution to overall system noise and power, while the two-op-amp instrumentation architecture simplifies gain implementation. Use short input traces, a stable gain resistor, and an appropriate output low-pass filter. The measurable benefit is a low-power differential signal path, but final signal-to-noise performance depends on sensor noise, resistor choice, reference quality, PCB layout, and the selected gain.

推荐产品汇总

INA2126 Same INA2126 family without the P package suffix 用于: Portable Sensor Signal Acquisition, Strain-Gauge Bridge Measurement, Battery-Powered Data Acquisition, Industrial Process Monitoring, Medical Instrument Front End, Low-Noise Sensor Interface
What is the INA2126P instrumentation amplifier?
The INA2126P is a dual-channel, micropower precision instrumentation amplifier from Texas Instruments. According to the manufacturer product page and INA2126 datasheet, each channel uses a two-op-amp architecture, consumes 175 µA of quiescent current, and supports an operating voltage range of ±1.35 V to ±18 V. The device is packaged in a 16-pin PDIP format and is intended for low-noise differential-signal acquisition in portable instrumentation and data-acquisition systems.
What is the operating voltage range of INA2126P?
The INA2126P operates from ±1.35 V to ±18 V, corresponding to a maximum total supply voltage of 36 V. This range is stated in the Texas Instruments INA2126 manufacturer documentation. The wide operating range allows the same device family to serve low-voltage portable equipment and higher-voltage industrial measurement systems, provided that the selected gain, input common-mode range, and output swing remain valid.
What is the quiescent current of INA2126P?
The INA2126P consumes 175 µA per channel, or approximately 350 µA when both channels are operating. According to the Texas Instruments INA2126 datasheet, the low quiescent current makes the family suitable for portable instrumentation and battery-powered data acquisition. Actual application current also depends on supply voltage, gain configuration, output loading, and the operating state of each channel.
What is the offset voltage of INA2126P?
The INA2126P has a specified 250 µV offset voltage. This figure is published on the Texas Instruments product page and in the manufacturer datasheet. Offset is important in low-level differential measurements because it can create a systematic output error after amplification. Designers should still account for gain-setting resistor tolerance, input bias effects, output offset, and the complete signal-chain error budget.
Where can I download the INA2126P datasheet PDF?
The official INA2126P datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina2126.pdf. The document is titled “MicroPower Instrumentation Amplifiers” and covers the INA126 and INA2126 families. It is the preferred source for pin assignments, electrical characteristics, gain selection, typical application circuits, and recommended PCB-layout details.
Where can I find the INA2126P pinout?
The INA2126P pinout is published in the official Texas Instruments INAx126/INA2126 datasheet available at https://www.ti.com/lit/ds/symlink/ina2126.pdf. The INA2126P is a 16-pin PDIP device with two instrumentation-amplifier channels. Because this JSON dataset does not include the complete verified pin table, individual pin names and numbers are marked as needing verification rather than reconstructed from memory.
Where can I buy INA2126P online?
The INA2126P can be ordered from Texas Instruments and is listed by DigiKey and Mouser in the verified web results. The DigiKey listing identifies it as a dual instrumentation amplifier in a 16-PDIP package, while Mouser provides product, inventory, and pricing information. XAIPART price and stock confirmation requires a current quote because the supplied distributor snippets do not expose numeric price or inventory values.
What is the price of INA2126P?
A verified unit price for INA2126P is not available in the supplied search snippets, so the current numeric price cannot be stated responsibly. Distributor listings at DigiKey and Mouser are the appropriate sources for a live quote, and pricing should be checked as of 2026-10-30. The price tiers in this dataset contain zero only as an explicit unavailable-price placeholder and should not be interpreted as a free commercial offer.
Is INA2126P in stock and what is its lead time?
The DigiKey search result states “Buy now, ships today” for INA2126P, but it does not provide a quantified stock level or a manufacturer lead-time commitment. According to the verified distributor listing, the part is presented as immediately orderable. For a production purchase, confirm current stock, package quantity, and lead time with the distributor as of 2026-10-30 because availability can change independently of search-result text.
Can INA2126PA replace INA2126P?
INA2126PA is the closest verified same-manufacturer alternative because it is also listed as a dual instrumentation amplifier in a 16-PDIP package. However, the supplied results do not expose its complete ordering table, accuracy grade, pin mapping, or parameter differences. Before treating it as a drop-in replacement, engineers should compare the INA2126 ordering table and verify channel count, gain-setting resistors, supply limits, offset, bandwidth, and package suffix in the current manufacturer documentation.
What is the best drop-in replacement for INA2126P?
The best drop-in replacement is the part that matches the INA2126P’s 16-pin PDIP footprint, dual-channel architecture, supply range, gain configuration, and electrical limits. INA2126PA is the only verified same-package candidate in the supplied cross-reference results, but the available data does not prove a zero-change substitution. No unrelated single-channel or surface-mount amplifier should be described as a drop-in replacement merely because its gain or supply rating looks similar.
INA2126P vs INA2126PA: which is better for a legacy PCB?
INA2126P is the safer baseline choice when the existing PCB was designed directly around the manufacturer’s INA2126P ordering option. INA2126PA appears in the verified data as another 16-PDIP dual instrumentation amplifier, but its suffix-specific grade and characteristics are not provided. Compare the current Texas Instruments ordering table before selecting it, especially for precision offset limits, temperature range, gain error, and any qualification requirements.
When should I choose INA2126P over a conventional dual op amp?
Choose INA2126P when the source is a low-level differential signal and matching, common-mode rejection, and gain-setting convenience are more important than minimal component count. Its integrated two-op-amp instrumentation-amplifier architecture is designed to amplify differential signals accurately, while the 175 µA per channel current supports low-power designs. A conventional dual op amp may cost less but requires more careful resistor matching and gain-error control.
Is INA2126P suitable for battery-powered sensor acquisition?
Yes, the INA2126P is suitable for battery-powered sensor acquisition when the measurement meets its input, output, gain, and bandwidth limits. Its 175 µA per channel quiescent current is the principal advantage in portable systems, while differential input helps reject common-mode noise. Designers should include sensor current, gain-setting-resistor current, ADC input load, and leakage when calculating total power.
What are the key specifications of INA2126P that engineers should know?
The key INA2126P specifications are two precision instrumentation-amplifier channels, 175 µA of quiescent current per channel, a 250 µV offset rating, operation from ±1.35 V to ±18 V, and a 16-PDIP package. According to Texas Instruments manufacturer documentation, the two-op-amp architecture supports accurate, low-noise differential acquisition. Gain range, bandwidth, common-mode rejection, and temperature limits require confirmation from the complete datasheet.
What can replace INA2126P?
INA2126PA is the leading verified candidate for replacing INA2126P because it is identified as a dual 16-PDIP instrumentation amplifier from Texas Instruments. The replacement should not be considered qualified for a drop-in design until the exact suffix ratings and pin configuration are checked in the current ordering information. The supplied cross-reference results did not identify five independently verified, electrically compatible alternatives, so unsupported equivalents are intentionally not presented as drop-ins.

工程参考数据: INA2126P ——对比、设计指导和合规信息。

选型指南

Choose INA2126P when a legacy through-hole PCB requires a dual, precision instrumentation amplifier with a 175 µA per channel quiescent current, 250 µV offset rating, and operation across ±1.35 V to ±18 V. It is particularly appropriate for low-level differential sensor signals where common-mode rejection and low supply demand matter. Consider INA2126PA only after confirming the current TI ordering table establishes the same pinout, package, electrical limits, and required accuracy grade. Do not substitute the single-channel INA126 family or a surface-mount INA2126 variant directly on the same PDIP footprint. If the application is a new compact design rather than a through-hole retrofit, compare modern low-power instrumentation amplifiers on full gain error, input common-mode range, noise density, supply current, and lifecycle status rather than package alone.

与替代料对比

参数 本产品 INA2126PA
Package 16-PDIP 16-PDIP - same
Brand Texas Instruments Texas Instruments
Number of Channels 2 circuits 2 circuits

关键差异点

  • Low quiescent current for a dual precision instrumentation amplifier (对比 INA2126PA)
  • Wide total supply capability (对比 INA2126PA)
  • Defined low-offset dual-channel configuration (对比 INA2126PA)

设计说明

Keep the two differential inputs as short and symmetric as practical, and place the gain-setting resistor close to the corresponding amplifier pins. Follow the Texas Instruments INAx126/INA2126 datasheet layout recommendation because parasitic resistance, input capacitance, and unequal traces can affect gain error, offset, and common-mode rejection. Use a quiet ground reference and avoid routing sensitive sensor inputs beside switching-converter or digital timing traces.

Verify the selected gain against the INA2126 gain-bandwidth and signal-settling requirements before layout is frozen. A low-power instrumentation amplifier does not automatically provide unlimited bandwidth; increasing gain can reduce available bandwidth. For a slow sensor front end, add anti-alias filtering after the amplifier using component values supported by the datasheet or simulation. For a fast channel, account for capacitance at the gain resistor and input nodes rather than relying only on nominal bandwidth.

Include the full system current budget rather than only the 175 µA per channel quiescent figure. Sensor excitation, gain-setting resistors, external references, ADC inputs, and protection networks may dominate current in a portable design. Also verify that the selected dual supply or single-supply configuration keeps every input and output within the INA2126 common-mode and output-swing limits. Add local supply bypass close to the device using the capacitance and layout specified in the manufacturer documentation.

Do not interpret the 250 µV offset value as the complete measurement error. Gain-setting resistor tolerance and temperature coefficient, input bias effects, output offset, ADC error, sensor error, and reference error all contribute to the system budget. Avoid using a single-channel amplifier or a surface-mount INA2126 suffix as a direct retrofit to a 16-PDIP PCB without a documented pin mapping. Confirm the exact ordering suffix and pin table before substituting any part.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied verified results describe the device, package, electrical headline parameters, and ordering information but do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements.

相关搜索

INA2126P datasheet Texas Instruments INA2126P INA2126P price INA2126P buy online INA2126P 16-PDIP instrumentation amplifier INA2126P 175 uA per channel INA2126P 250 uV offset INA2126P pinout INA2126P vs INA2126PA INA2126P drop-in replacement micropower instrumentation amplifier for sensor acquisition INA2126P lead time and stock

相关元器件 & 术语

Texas Instruments INA2126P INA2126 INA2126PA INA126 INAx126 instrumentation amplifier precision instrumentation amplifier differential amplifier analog signal conditioner two-op-amp architecture low-noise signal acquisition 175 µA per channel 250 µV offset ±1.35 V to ±18 V operating range 36 V maximum supply 16-PDIP PDIP package family through-hole mounting common-mode rejection portable instrumentation data acquisition strain-gauge bridge battery-powered measurement
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情