ISO1450DW - 50 Mbps 5 kVrms Isolated RS-485/RS-422 | Texas Instruments
料号: ISO1450DW ✓ 量产中ISO1450DW 概述
直接替换替代料: ISO1450DW ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ISO1450DW (相同外形与封装尺寸) ——差异在于 Package, Product Type, EMC Protection, Maximum Data Rate, Operating Temperature Range.
ISO1450BDW
✅ 直接替换联系询价
查看数据手册 →ISO1410BDW
✅ 直接替换联系询价
查看数据手册 →ISO1430DWR
✅ 直接替换联系询价
查看数据手册 →ISO1452DW
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →ISO1452DWR
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →ISO1450DW 规格参数
| Product Type | Isolated RS-485/RS-422 transceiver |
| Transceiver Configuration | 1/1 half-duplex |
| Maximum Data Rate | 50 Mbps |
| Isolation Voltage | 5 kVrms |
| Supply Voltage Range | 1.71 V to 5.5 V |
| 工作温度范围 | -40 °C to 125 °C |
| 封装 | 16-pin SOIC wide-body (DW) |
| 安装类型 | Surface mount |
| Supported Standards | TIA/EIA RS-485 and RS-422 |
| Differential Communication | Yes |
| Direction Control | Half-duplex |
| EMC Protection | EMC protected |
| Isolation Type | Galvanic isolation |
| Logic Compatibility | 1.71 V to 5.5 V supply operation |
| Manufacturer Evaluation Module | ISO1410DWEVM for related ISO1410 evaluation |
ISO1450DW 16-pin soic wide-body (dw) 引脚配置指南
ISO1450DW(16-pin soic wide-body (dw) 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ISO1450DW.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ISO1450DW 适用于 6 应用s: Factory Automation Communication, Industrial Sensor Gateway, Programmable Logic Controller Interface, Test and Measurement Equipment, Building and Energy Systems, Medical and Diagnostic Equipment.
Factory Automation Communication
The ISO1450DW fits isolated factory-automation links requiring a 50-Mbps differential transceiver and 5-kVrms isolation. It can connect a controller or programmable-logic device to RS-485 equipment while separating the bus-side environment from sensitive logic circuitry. Its verified -40 °C to 125 °C range suits industrial temperature conditions. The principal design consideration is managing the shared half-duplex bus through direction control and applying termination only where the selected topology requires it.
推荐
Industrial Sensor Gateway
ISO1450DW can serve as the isolated RS-485/RS-422 interface in a sensor gateway that aggregates measurements from field equipment. The 50-Mbps capability provides ample signaling headroom for short, controlled industrial links, while 5-kVrms isolation helps protect the gateway electronics from ground-potential differences and bus transients. Because the interface is half-duplex, the firmware should coordinate bus direction and avoid simultaneous transmission attempts. External surge protection remains an application-level requirement.
推荐
Programmable Logic Controller Interface
The ISO1450DW is appropriate for a programmable logic controller or industrial controller that needs a high-speed isolated differential bus. Its 1.71 V to 5.5 V operating range supports common digital supply environments, and the 16-pin wide-body SOIC package simplifies comparison with other TI isolated interface designs. Isolation can reduce the effect of ground shifts in distributed cabinets, but engineers must still design the isolation barrier, creepage, clearance, and bus protection according to the complete datasheet.
推荐
Test and Measurement Equipment
ISO1450DW can connect laboratory or field-test equipment to a half-duplex RS-485 or RS-422 instrument bus. The 50-Mbps rate supports short, high-speed test links, while 5-kVrms isolation helps protect test electronics from connected equipment. The 1.71 V to 5.5 V supply range allows integration with multiple logic levels. Designers should control cable length and reflections carefully because nominal signaling speed does not guarantee adequate margin over arbitrary cable lengths or topologies.
推荐
Building and Energy Systems
The ISO1450DW can be used in building-control or energy-management equipment requiring an isolated RS-485 communication path. The half-duplex topology is well suited to bus-oriented controllers, and the EMC protection helps maintain operation in environments with electrically noisy equipment. Its extended -40 °C to 125 °C range supports deployed industrial equipment. The isolation barrier should be evaluated for the applicable installation environment, and bus termination should be planned for the cable network rather than added indiscriminately.
推荐
Medical and Diagnostic Equipment
ISO1450DW can provide an isolated communications link in medical or diagnostic equipment where a patient-connected or externally accessible system requires separation from communication circuitry. Its 5-kVrms isolation and EMC protection are relevant to that isolation objective, while 50-Mbps operation supports short, high-speed control or monitoring links. However, the supplied data does not state medical certification, so this use requires separate safety, regulatory, and system-level validation beyond the component specifications.
推荐
推荐产品汇总
工程参考数据: ISO1450DW ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ISO1450BDW | ISO1410BDW | ISO1430DWR | ISO1452DW | ISO1452DWR |
|---|---|---|---|---|---|---|
| Package | 16-pin SOIC wide-body (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
关键差异点
- Verified high-speed isolated data capability (对比 ISO1430DWR)
- Explicit EMC protection (对比 ISO1410BDW)
- Wide supply-voltage operating range (对比 ISO1450BDW)
设计说明
Place the transceiver and its bus-side protection components near the connector and keep the high-current and high-switching return paths away from the isolated logic side. Maintain the isolation barrier without copper or unintended plane overlap, and follow the manufacturer's recommended layout for input and output bypass capacitors. The complete pin and layout information must be taken from the ISO1450 datasheet because the supplied verified excerpts do not include the complete pin table.
Do not select a replacement solely because it is labeled a 16-pin SOIC. Confirm pin names, direction-control polarity, receiver enable behavior, isolation rating, supply range, and bus terminal mapping. ISO1450DW uses a half-duplex bus arrangement, so transmitter and receiver sharing creates timing and contention risks. Firmware must avoid enabling transmission while another node is driving the same bus.
Use the EMC protection and 5-kVrms isolation as part of a complete interface design, not as a substitute for external surge and ESD protection. The bus cable can introduce transients that exceed the transceiver's ratings. Select protection components using the actual bus voltage, ground-potential range, data rate, and installation standard, and verify termination and common-mode behavior with the intended cable and topology.
合规信息
The supplied verified results include a comparison page mentioning RoHS and REACH status for ISO1410BDW versus ISO1450DW, but the snippets do not provide the actual compliance values for ISO1450DW. No compliance claims are therefore inferred.