ITS4035SEPDXUMA1 - 35mΩ Smart High-Side Switch 13.2A | Infineon
料号: ITS4035SEPDXUMA1 ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $2.65 | $2.65 |
| 10 | $2.38 | $23.80 |
| 100 | $2.05 | $205.00 |
| 500 | $1.78 | $890.00 |
| 1,000 | $1.52 | $1,520.00 |
| 2,500 | $1.31 | $3,275.00 |
ITS4035SEPDXUMA1 概述
A smart high-side switch is a type of power distribution switch that sits between the system supply and the load, providing both load-driving capability and integrated protection features (overcurrent, overtemperature, short-circuit, ground-loss, and reverse-polarity protection). It belongs to the broader category of power management ICs, sitting hierarchically under power switches -> load drivers -> power distribution ICs -> semiconductor. Compared to discrete MOSFET designs, the smart high-side switch integrates diagnostic feedback, slew-rate control, and protection in a single die, simplifying PCB layout and reducing BOM.
Key features include a typical R<sub>DS(ON)</sub> of 35 mΩ at 25 °C, an active-high logic-level enable input, open-drain status flag output, integrated thermal shutdown with auto-restart, and Infineon's PROFET™ protection suite including overvoltage clamp and current limitation. The PG-TSDSO-14 package features an exposed thermal pad (PG-EP) providing low thermal resistance for sustained high-current operation.
The architecture uses an N-channel MOSFET configured as a high-side switch with charge-pump gate drive, supporting a wide logic-level input interface for direct connection to microcontrollers. Its 35 mΩ on-resistance minimises conduction losses at full load, while the built-in current-limit and temperature monitoring ensure robust operation in fault conditions.
Typical applications include industrial PLCs, factory automation loads, programmable logic controllers, solenoid and valve drivers, lighting relay replacements, and protected 24 V power distribution in building automation. The wide operating voltage range also makes it suitable for 12 V/24 V battery-driven systems in commercial vehicles and rugged industrial equipment.
When designing with this device, ensure the input capacitor (typically 100 nF close to Vbb) and sufficient PCB copper area on the exposed pad are provided for thermal dissipation. The status output requires a pull-up resistor to logic high, and the enable logic must be observed during system power-up sequencing to avoid inrush glitches.
This page synthesises distributor pricing, PROFET family variants, and practical design notes for the ITS4035S-EP family not found in the manufacturer datasheet alone.
直接替换替代料: ITS4035SEPDXUMA1 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ITS4035SEPDXUMA1 (相同外形与封装尺寸) ——差异在于 Package, Continuous Output Current, Diagnostic Output, Number of Channels, Operating Temperature.
快速对比工具——选择替代料号进行并排对比:
ITS4035S-EP-D
✅ 直接替换📋 参考替代料(不在目录中)
BTS70402EPGXUMA1
✅ 直接替换✓ 有现货
$3.18 / 个
查看数据手册 →BTS51202EKAXUMA1
✅ 直接替换✓ 有现货
$1.68 / 个
查看数据手册 →ISP752TFUMA1
✅ 直接替换✓ 有现货
$1.02 / 个
查看数据手册 →TLE7240SLXUMA1
✅ 直接替换📋 参考替代料(不在目录中)
ITS4035SEPDXUMA1 最大额定值与电气特性
| Switch Type | Single-channel Smart High-Side Power Switch |
| 拓扑 | 1:1 N-Channel MOSFET |
| RDS(ON) (typical) | 35 mΩ at 25 °C |
| Continuous Output Current | 13.2 A |
| Current Limit (programmable) | 3 A to 13.2 A |
| Operating Supply Voltage (Vbb) | 5 V to 28 V |
| Logic-Level Input (IN) | Active high, CMOS/TTL compatible |
| Status Output (ST) | Open-drain diagnostic flag |
| Protection Features | Overcurrent, Overtemperature, Short-Circuit, Overvoltage, Ground-Loss, Reverse Polarity |
| 工作温度范围 | -40 °C to +150 °C |
| 封装 | PG-TSDSO-14 (Exposed Pad) |
| 安装类型 | Surface Mount |
| Family | PROFET™ Industrial |
| RoHS 状态 | Compliant |
ITS4035SEPDXUMA1 引脚配置
| 引脚 1 | OUT — Switch output to load |
| 引脚 2 | Vbb — Battery supply input (5-28 V) |
| 引脚 3 | IN — Logic-level enable input (active high) |
| 引脚 4 | ST — Open-drain status output |
| 引脚 5 | GND — Ground reference |
| 引脚 6 | NC — Not connected (per datasheet) |
| 引脚 7 | NC — Not connected (per datasheet) |
| 引脚 8 | NC — Not connected (per datasheet) |
| 引脚 9 | NC — Not connected (per datasheet) |
| 引脚 10 | NC — Not connected (per datasheet) |
| 引脚 11 | NC — Not connected (per datasheet) |
| 引脚 12 | NC — Not connected (per datasheet) |
| 引脚 13 | NC — Not connected (per datasheet) |
| 引脚 14 | EP — Exposed thermal pad - connect to GND for heatsinking |
典型应用
ITS4035SEPDXUMA1 适用于 6 应用s: Industrial PLC Digital Outputs, 24V Industrial Load Switching, Building Automation Power Distribution, Solenoid and Valve Drivers, Lighting Relay Replacement, Commercial Vehicle 24V Power Switching.
Industrial PLC Digital Outputs
The ITS4035SEPDXUMA1 is ideal for industrial PLC digital output modules driving 24 V solenoid valves, relays, and indicator lamps. Its 13.2 A continuous current and 35 mΩ R<sub>DS(ON)</sub> handle multi-axis machine loads without external heatsinking beyond PCB copper, while the programmable 3-13.2 A current limit protects wiring harness shorts typical in factory floors. The integrated overtemperature shutdown with auto-restart and ground-loss protection reduce field failure rates compared to discrete MOSFET designs, and the open-drain status output feeds back to the PLC CPU for diagnostic verification of each output's health in real time.
推荐
24V Industrial Load Switching
The ITS4035SEPDXUMA1 directly drives 24 V industrial loads such as motor brakes, clutch coils, heaters, and hydraulic actuators from a single high-side switch. Its 5 V to 28 V Vbb range covers the full industrial 24 V bus including transients up to 35 V load-dump, and its active-high CMOS-compatible enable input interfaces directly with 3.3 V or 5 V microcontroller GPIO. The exposed thermal pad efficiently dissipates the conduction loss (≈ 6 W at full 13.2 A load), and the PROFET reverse-polarity protection withstands miswiring during field installation, a common cause of industrial load-switch failures.
推荐
Building Automation Power Distribution
The ITS4035SEPDXUMA1 enables protected 24 V power distribution in building automation systems including HVAC actuators, smart lighting controls, and access-control relays. Its 35 mΩ R<sub>DS(ON)</sub> keeps conduction losses low even at sustained 5-10 A loads, reducing thermal stress in enclosed wall-mounted control cabinets. The diagnostic status flag provides per-channel fault feedback to the building management system (BMS), and the integrated short-circuit and overcurrent protection eliminates the need for replaceable fuses, dramatically reducing field maintenance costs over the system's lifetime.
推荐
Solenoid and Valve Drivers
The ITS4035SEPDXUMA1 drives 24 V DC solenoid valves and pneumatic actuators in process control and factory automation. Its slew-rate-controlled turn-on/turn-off reduces electromagnetic emissions (EME) on long cable runs, an EMC challenge in industrial valve manifolds. The programmable current limit can be set below the solenoid's inrush current to limit supply transients when multiple valves switch simultaneously, and the open-drain status output returns a per-channel health flag for predictive maintenance in Industry 4.0 architectures.
推荐
Lighting Relay Replacement
The ITS4035SEPDXUMA1 replaces mechanical relays and discrete MOSFETs in industrial and architectural lighting control, providing silent solid-state switching with no contact bounce or coil inductance. Its 13.2 A continuous rating covers LED array strings, fluorescent ballasts, and incandescent loads in commercial installations, while the integrated protection suite prevents catastrophic failure from short circuits in aged fixtures. The exposed-pad PG-TSDSO-14 package supports sustained high current with PCB copper heatsinking alone, simplifying fixture design and improving long-term reliability over electromechanical relays.
推荐
Commercial Vehicle 24V Power Switching
The ITS4035SEPDXUMA1 is well-suited for 24 V commercial vehicle body-control applications including load-switching for auxiliary lamps, horns, pumps, and HVAC blowers. Its 5-28 V operating range tolerates 24 V truck and bus electrical systems with load-dump transients, and the -40 °C to +150 °C operating temperature handles underhood and chassis mounting. The PROFET reverse-polarity and ground-loss protection withstands jump-start miswiring and chassis-ground fault conditions common in fleet vehicle service, reducing warranty returns versus unprotected discrete designs.
推荐
推荐产品汇总
工程参考数据: ITS4035SEPDXUMA1 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ITS4035S-EP-D | BTS70402EPGXUMA1 | BTS51202EKAXUMA1 | ISP752TFUMA1 | TLE7240SLXUMA1 |
|---|---|---|---|---|---|---|
| Brand | Infineon | Infineon - same | Infineon - same | Infineon - same | Infineon - same | Infineon - same |
| Package | PG-TSDSO-14 (Exposed Pad) | PG-TSDSO-14 (Exposed Pad) - same | PG-TSDSO-14 (Exposed Pad) - same | PG-TSDSO-14 (Exposed Pad) - same | PG-TSDSO-14 (Exposed Pad) - same | PG-TSDSO-14 (Exposed Pad) - same |
| Channel Count | 1 | 1 | 2 | 2 | 1 | 4 |
| Logic Input | Active High | Active High | Active High | Active High | Active High | SPI control |
| Status Output | Open-drain diagnostic flag | Open-drain diagnostic flag | Open-drain diagnostic flag | Open-drain diagnostic flag | Open-drain diagnostic flag | SPI feedback |
关键差异点
- Single-channel 13.2 A capability in compact PG-TSDSO-14 (对比 BTS70402EPGXUMA1)
- Wide 5 V to 28 V Vbb operating range (对比 ISP752TFUMA1)
- PROFET™ full protection suite with ground-loss and reverse-polarity (对比 TLE7240SLXUMA1)
设计说明
Estimated: at full 13.2 A load and 35 mΩ R<sub>DS(ON)</sub>, conduction loss is approximately 6.1 W (I²R = 13.2² × 0.035). The PG-TSDSO-14 exposed thermal pad MUST be soldered to a PCB copper area of at least 1 square inch (≈ 6 cm²) of 2 oz copper to keep junction temperature rise below 50 °C above ambient. In enclosed industrial cabinets with limited convection, additional copper area or a small heatsink may be required for sustained full-load operation.
Place a 100 nF ceramic decoupling capacitor as close as possible to the Vbb pin to suppress supply transients from the inductive load. The exposed thermal pad should use multiple thermal vias (at least 9 vias in a 3x3 grid, 0.3 mm drill) to conduct heat to the inner PCB copper planes. Wide copper traces (at least 0.5 mm per ampere) on OUT and Vbb minimise voltage drop and secondary heating of the PCB.
Do not exceed the absolute maximum Vbb rating of 28 V sustained (load-dump transients up to 35 V are tolerated briefly). Always provide a pull-up resistor on the open-drain ST status output (typically 10 kΩ to 5 V) - leaving it floating will not damage the device but will mask diagnostic faults. When driving inductive loads (solenoids, relays), add a flyback/clamping diode across the load - the ITS4035SEPDXUMA1's internal overvoltage clamp is not designed for continuous freewheeling energy dissipation.
合规信息
RoHS and lead-free compliance per Infineon product page. Not AEC-Q100 qualified (industrial PROFET family, not automotive grade). MSL level not confirmed from public data - see [DATA_NEEDED] in specs.