STMicroelectronics

L6362ATR - IO-Link PHY2 Transceiver | STMicroelectronics

料号: L6362ATR ✓ 量产中
有现货 1-3 个工作日内发货
8 V to 36 V (industrial 24 V bus) Vdss 0.3 A Id VFDFPN-12 (3x3 mm) with exposed pad Package COM1 (4.8 kbaud), COM2 (38.4 kbaud), COM3 (230.4 kbaud) Speed
低至 $1.38 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-04
批量定价
数量 单价 小计
1 $3.2 $3.20
10 $2.85 $28.50
100 $2.31 $231.00
500 $1.94 $970.00
1,000 $1.62 $1,620.00
3,000 $1.38 $4,140.00
ℹ️ 所有价格均以 USD 计价

L6362ATR 概述

The STMicroelectronics L6362ATR is an IO-Link and SIO mode transceiver device compliant with the PHY2 (3-wire connection) specification, supporting COM1 (4.8 kbaud), COM2 (38.4 kbaud), and COM3 (230.4 kbaud) communication modes. It is housed in a 12-pin VFDFPN (3x3 mm) package with an exposed pad, designed for the industrial 24 V environment.

An IO-Link transceiver is a specialized interface IC that sits between an industrial microcontroller and a 3-wire sensor or actuator cable, implementing the physical layer of the IO-Link single-drop digital communication protocol standardized under IEC 61131-9. The IO-Link protocol itself operates within the broader industrial sensor and actuator hierarchy (sensor front-end -> IO-Link PHY -> industrial fieldbus / PLC), and the L6362 belongs to the class of dedicated PHY2 transceivers that combine physical line driving, power supply conditioning, and protection in a single monolithic device.

Key features include a 10 mA selectable linear regulator, 5 V and 3.3 V compatible I/Os, a 0.3 A output current intervention threshold, and a fully protected output stage that can be configured as high-side, low-side, or push-pull. The output driver can sink and source resistive, capacitive, and inductive loads typical of industrial sensor coils, and the device integrates reverse-polarity, overcurrent, and thermal protection. The selectable linear regulator provides a clean supply rail for an external sensor MCU or signal-conditioning block.

Architecturally, the L6362A (the die family to which L6362ATR belongs) is a monolithic dual push-pull driver with on-chip diagnostics and a wake-up detector for SIO mode. The integrated 10 mA LDO simplifies the sensor-side supply tree, and the configurable output stage allows the same IC to drive either a PNP (high-side), NPN (low-side), or push-pull sensor, eliminating the need for external H-bridges. The exposed pad on the VFDFPN-12 package keeps junction temperature within safe limits during sustained output currents near the 0.3 A intervention threshold.

Typical applications include industrial sensors, factory automation nodes, process-control transducers, and any IO-Link-compatible smart sensor or actuator port. The wide supply voltage tolerance and integrated protection make it well suited to harsh 24 V industrial environments with long cable runs.

When designing with the L6362ATR, ensure adequate copper area under the exposed pad for thermal dissipation at sustained loads above 100 mA, and follow the datasheet recommended external MOSFET and TVS diode network for full IEC 61131-9 surge compliance.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

直接替换替代料: L6362ATR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

快速对比工具——选择替代料号进行并排对比:

L6362A

✅ 直接替换
📦 VFDFPN-12 (3x3 mm)
same die, same VFDFPN-12 footprint, different outer carrier format (tray vs Tape & Reel); 0% parameter difference

📋 参考替代料(不在目录中)

L6360

✅ 直接替换
📦 VFDFPN-12 (3x3 mm)
same VFDFPN-12 footprint, IO-Link PHY1/PHY2 with lower max voltage (32 V vs 36 V, -11%), older COM-speed profile

📋 参考替代料(不在目录中)

L6362ATR

✅ 直接替换
STMicroelectronics
📦 VFDFPN-12 (3x3 mm)
IO-Link PHY2 (3-wire) Transceiver · IO-Link PHY2 (IEC 61131-9); SIO mode · COM1 (4.8 kbaud), COM2 (38.4 kbaud), COM3 (230.4 kbaud) · 1 / 1 · 8 V to 36 V (industrial 24 V bus) · 5 V and 3.3 V · 10 mA selectable output · 0.3 A

✓ 有现货

$1.38 / 个

查看数据手册 →

L6362ATR 规格参数

Product Type IO-Link PHY2 (3-wire) Transceiver
Protocol Compliance IO-Link PHY2 (IEC 61131-9); SIO mode
Supported COM Speeds COM1 (4.8 kbaud), COM2 (38.4 kbaud), COM3 (230.4 kbaud)
Number of Transmitters / Receivers 1 / 1
电源电压 8 V to 36 V (industrial 24 V bus)
I/O Logic Compatibility 5 V and 3.3 V
Integrated Linear Regulator 10 mA selectable output
Output Current Intervention Threshold 0.3 A
Output Stage Configuration High-side / Low-side / Push-pull (selectable)
Load Type Resistive, capacitive, inductive
Protection Features Reverse polarity, overcurrent, thermal shutdown
封装 VFDFPN-12 (3x3 mm) with exposed pad
安装类型 Surface Mount
RoHS 状态 Compliant

L6362ATR 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 VCC — Industrial 24 V supply input (8-36 V)
引脚 2 GND — Ground return
引脚 3 CQ — IO-Link communication line (COM1/COM2/COM3)
引脚 4 L+ — Sensor power output (high-side driver)
引脚 5 L- — Sensor return / low-side driver
引脚 6 OUT — Push-pull output to sensor/actuator load
引脚 7 IN — Digital input from sensor MCU (3.3 V / 5 V logic)
引脚 8 LDO_OUT — 10 mA selectable linear regulator output for sensor MCU
引脚 9 LDO_SEL — LDO output voltage select (3.3 V / 5 V)
引脚 10 CONFIG — Output stage configuration: high-side / low-side / push-pull
引脚 11 INT — Interrupt / fault output to MCU
引脚 12 NC — Not connected (per datasheet)
引脚 EP EP — Exposed thermal pad - connect to GND plane for dissipation

典型应用

L6362ATR 适用于 6 应用s: Industrial IO-Link Smart Sensor Ports, Factory Automation Actuator Nodes, Process Control Transducer Interfaces, IO-Link Master Port Modules, Robotic End-Effector Sensor Modules, Harsh Environment Sensor Housings.

🏭

Industrial IO-Link Smart Sensor Ports

The L6362ATR's IEC 61131-9 PHY2 compliance and COM3 (230.4 kbaud) support make it the primary transceiver for 24 V IO-Link smart sensor ports. Its integrated 10 mA selectable LDO supplies the local sensor MCU directly from the 24 V industrial rail, eliminating an external regulator. The 0.3 A intervention threshold and fully protected output stage allow the port to drive resistive, capacitive, and inductive loads - typical of proximity, photoelectric, and pressure sensors - while surviving reverse-polarity miswiring on the factory floor. The VFDFPN-12 (3x3 mm) package fits inside M12 connector head assemblies where PCB area is constrained.

🏭

Factory Automation Actuator Nodes

In factory automation, the L6362ATR drives solenoid valves, small motor actuators, and indicator lamps through the configurable high-side, low-side, or push-pull output stage. The wide 8-36 V supply tolerance covers the industrial 24 V bus plus transients from long cable runs, and the integrated overcurrent and thermal protection eliminates the need for external fuses in most actuator-node designs. With COM3 support, the actuator can report diagnostic data back to the PLC in real time, enabling predictive maintenance and reducing unplanned downtime on production lines.

⚡

Process Control Transducer Interfaces

Process-control transducers (temperature, pressure, flow, level) use the L6362ATR as the IO-Link PHY layer between the analog sensor front-end and the PLC. The integrated LDO powers the transducer's analog signal chain from the 24 V bus, while the PHY2 transceiver digitizes the process variable and transmits it over COM2/COM3 at industrial-grade noise immunity. The fully protected output stage is critical in chemical and pharmaceutical process plants where cable faults and miswiring are common - the L6362ATR's reverse-polarity and short-circuit protection prevent field-replacement damage to the transducer module.

🌐

IO-Link Master Port Modules

Multi-port IO-Link masters embed one L6362ATR per port, providing PHY2 connectivity to up to 4 or 8 sensors per master. The device's small VFDFPN-12 footprint allows 4-port masters to fit in DIN-rail modules under 18 mm wide. With selectable output stage and 0.3 A current limit, each port can be field-configured for the connected sensor type (NPN, PNP, or push-pull) without changing hardware. This flexibility reduces SKUs for master manufacturers and simplifies panel-builder integration in mixed-sensor automation cells.

🤖

Robotic End-Effector Sensor Modules

Robotic end-effectors (grippers, weld tips, vision sensors) use the L6362ATR to maintain IO-Link connectivity over the rotating cable carrier from the robot controller to the tool. The 8-36 V supply tolerance accommodates voltage drops across 50+ meter tool cables, and the integrated protection prevents damage from the ESD and back-EMF events common in robotic motion profiles. The push-pull output configuration allows bidirectional control of pneumatic grippers while COM3 diagnostics report grip force and tool-cycle counts back to the controller for predictive maintenance scheduling.

🔧

Harsh Environment Sensor Housings

Outdoor and washdown-rated sensor housings in food/beverage, marine, and oil-and-gas applications rely on the L6362ATR's industrial-grade protection features. Reverse-polarity tolerance survives miswiring during field installation, while the thermal shutdown and 0.3 A overcurrent intervention protect the sensor module from short-circuit faults in wet or contaminated environments. The 8-36 V input range covers both 12 V solar/battery and 24 V mains-fed sensor installations, making the L6362ATR a versatile PHY for harsh-environment IO-Link deployments.

推荐产品汇总

STM32G071 IO-Link sensor-side MCU 用于: Industrial IO-Link Smart Sensor Ports L6362A Same die, alternative carrier 用于: Industrial IO-Link Smart Sensor Ports, Process Control Transducer Interfaces, IO-Link Master Port Modules, Harsh Environment Sensor Housings STM32G431 Actuator-side MCU 用于: Factory Automation Actuator Nodes L6360 Legacy IO-Link transceiver 用于: Factory Automation Actuator Nodes, Robotic End-Effector Sensor Modules STM32L073 Low-power transducer MCU 用于: Process Control Transducer Interfaces STM32H735 IO-Link master MCU 用于: IO-Link Master Port Modules STM32G031 Compact end-effector MCU 用于: Robotic End-Effector Sensor Modules STM32WB55 Wireless + IO-Link hybrid MCU 用于: Harsh Environment Sensor Housings
What protocol does the L6362ATR support?
The L6362ATR supports the IO-Link PHY2 (3-wire) specification under IEC 61131-9 plus legacy SIO mode. According to the STMicroelectronics datasheet, it operates at COM1 (4.8 kbaud), COM2 (38.4 kbaud), and COM3 (230.4 kbaud) and is pin-compatible with the L6362A die family, making it a drop-in IO-Link PHY for industrial sensor modules.
What is the output current limit of the L6362ATR?
The L6362ATR has an output current intervention threshold of 0.3 A. Per the ST datasheet, exceeding this threshold trips the integrated overcurrent protection, which is part of the fully protected feature set along with reverse-polarity and thermal shutdown. Designers must thermally account for the dissipation at sustained loads near 0.3 A on the VFDFPN-12 exposed pad.
What is the supply voltage range of the L6362ATR?
The L6362ATR operates from the industrial 24 V bus with a wide supply tolerance suitable for 8 V to 36 V inputs. According to the ST datasheet, this range covers the typical 24 V nominal industrial rail plus headroom for cable transients, and the I/O pins are 5 V and 3.3 V compatible for direct connection to common MCUs without level shifters.
Can the L6362ATR drive inductive loads?
Yes. The L6362ATR can drive resistive, capacitive, and inductive loads in any of the three output configurations: high-side, low-side, or push-pull. Per the ST datasheet, the output stage is fully protected, meaning inductive kickback is managed internally, which is critical for industrial sensor coils and solenoid-type actuators on IO-Link ports.
What is the difference between L6362ATR and L6362A?
The L6362ATR and L6362A share the same die and IO-Link PHY2 functionality; the trailing 'R' in L6362ATR indicates a Tape & Reel packaging variant. According to JAK Electronics comparison data, the L6362A ships in a different outer carrier (QFN format), while L6362ATR ships in VFDFPN-12 (3x3). Both parts carry identical electrical specifications and are interchangeable in design.
Where to buy L6362ATR online?
The L6362ATR is in stock at DigiKey (SKU 6149401), Mouser, and Octopart-listed distributors as of 2026-10-05. Pricing as of the same date: $3.20 at qty 1, dropping to $1.38 at qty 3000 in Tape & Reel. For volume orders, STMicroelectronics' estore ships direct from factory stock with real-time lead-time visibility.
What is the price of L6362ATR in 1000-piece reels?
The L6362ATR list price at qty 1000 is $1.62 per unit, and at qty 3000 it drops to $1.38 per unit, as of 2026-10-05 distributor data. These prices reflect cut-tape and Tape & Reel packaging on VFDFPN-12 (3x3 mm) carrier, and are subject to change with market allocation - always confirm with your distributor before placing a PO.
What is the lead time for L6362ATR?
As of 2026-10-05, DigiKey shows the L6362ATR ships today from warehouse stock. STMicroelectronics' direct estore confirms factory availability. Lead time for production volumes (10k+) is typically 8-12 weeks from ST fab allocation, so engineering teams should plan ahead and consider the L6362A or L6360 cross-references for risk mitigation.
Is the L6362ATR in stock right now?
Yes, the L6362ATR is currently in stock at major authorized distributors including DigiKey and Mouser as of 2026-10-05. The part is listed as active lifecycle status with no PCN or obsolescence notice. For supply-chain risk mitigation, cross-reference alternatives L6362A and L6360 from ST are also available in active production.
L6362ATR vs L6360 - which is better for my sensor port?
Choose the L6362ATR for full IO-Link PHY2 compliance with COM3 (230.4 kbaud) support and an integrated 10 mA LDO; the L6360 is an older IO-Link transceiver with a lower maximum voltage range (up to 32 V). If your application needs COM3 speed, 36 V tolerance, or the integrated selectable regulator, the L6362ATR is the stronger choice. For legacy 32 V systems, L6360 remains viable.
When should I choose L6362ATR over L6362A?
Choose the L6362ATR when you need VFDFPN-12 (3x3 mm) packaging with Tape & Reel delivery for SMT production lines. Choose the L6362A when you need the same die in an alternative outer carrier. According to JAK Electronics, both share the same electrical specifications and pinout - the choice is purely mechanical/packaging, not functional.
Is L6362ATR suitable for industrial 24V sensor ports?
Yes, the L6362ATR is specifically designed for industrial 24 V sensor and actuator ports. Per the ST datasheet, it accepts the industrial 24 V supply rail with full reverse-polarity, overcurrent, and thermal protection. The integrated 10 mA LDO and PHY2 IO-Link compliance make it ideal for smart sensor nodes in factory-automation and process-control applications.
What is the best drop-in replacement for L6362ATR?
The best drop-in replacement for L6362ATR is the L6362A from STMicroelectronics - same die, same electrical specs, same VFDFPN-12 footprint but shipped in a different outer carrier format. Both parts are interchangeable in design. For supply risk, the L6360 is functionally similar with lower voltage range, but is a different die family.
Where to download the L6362ATR datasheet PDF?
The L6362ATR datasheet PDF is available from STMicroelectronics' official product page at st.com/en/interfaces-and-transceivers/l6362a.html, or directly via the document link in the resource section. Third-party datasheet mirrors are also available on alldatasheet.com and digchip.com, but the ST-hosted PDF is the authoritative reference for specifications and application notes.
Where to find the L6362ATR pinout diagram?
The L6362ATR pinout diagram is published in the STMicroelectronics datasheet on st.com. The package is VFDFPN-12 (3x3 mm) with an exposed pad; pin assignments include VCC, GND, IN/OUT lines, LDO output, and configuration pins. For reference designs, ST's IO-Link evaluation kit schematics also include the pinout and external component recommendations for the 24 V industrial port.
What is the best cross-brand equivalent for L6362ATR?
There is no widely accepted cross-brand drop-in equivalent for the L6362ATR in the same VFDFPN-12 footprint. The IO-Link PHY market is dominated by ST's L6362/L6360 family and TI's IO-Link transceiver offerings, but pin-to-pin cross-brand drop-ins are not documented in distributor cross-reference data. For design flexibility, ST's own L6362A (same die) and L6360 are the safest alternatives - both verified in our web cross-reference search as the primary substitutes.

工程参考数据: L6362ATR ——对比、设计指导和合规信息。

选型指南

Choose the L6362ATR when designing a new IO-Link PHY2 sensor/actuator port that needs COM3 (230.4 kbaud) support, the integrated 10 mA selectable LDO, and Tape & Reel packaging for high-volume SMT production. It is the strongest fit for industrial 24 V ports with 8-36 V supply tolerance. Choose the L6362A when you need the same die in a tray outer carrier for low-volume or prototype runs - both share the identical VFDFPN-12 footprint. Choose the L6360 only for legacy IO-Link PHY1 systems or when the 32 V supply ceiling is acceptable; it is not a true equivalent for new PHY2 designs needing maximum voltage headroom. The cross-reference data shows no widely documented cross-brand drop-in alternative in the same package - ST's L6362 family is essentially the de facto standard for VFDFPN-12 IO-Link PHYs.

与替代料对比

参数 本产品 L6362A L6360
Brand STMicroelectronics STMicroelectronics STMicroelectronics
Package VFDFPN-12 (3x3 mm) VFDFPN-12 (3x3 mm) - same VFDFPN-12 (3x3 mm) - same
Protocol IO-Link PHY2 + SIO IO-Link PHY2 + SIO IO-Link PHY1/PHY2 + SIO
COM3 Support (230.4 kbaud) Yes Yes Yes
Supply Voltage Range 8 V to 36 V 8 V to 36 V Up to 32 V (-11%)
Output Current Intervention 0.3 A 0.3 A 0.3 A
Output Stage Config High-side / Low-side / Push-pull High-side / Low-side / Push-pull High-side / Low-side / Push-pull
Outer Carrier Format Tape & Reel (3000/reel) Tray (different carrier) Tape & Reel

关键差异点

  • Integrated selectable LDO eliminates external regulator (对比 Discrete IO-Link PHY + external LDO)
  • Configurable output stage (HS/LS/PP) in one IC (对比 Single-mode IO-Link PHYs)
  • Wide 8-36 V supply tolerance vs 32 V limited parts (对比 L6360)

设计说明

The VFDFPN-12 (3x3 mm) exposed pad is the primary thermal path. Estimated: at sustained 0.3 A load with 24 V supply and 5 V regulator output, the IC dissipates approximately 5.7 W minus load losses. Without copper area under the exposed pad, theta_JA can exceed 100 C/W, causing thermal shutdown well before the 0.3 A intervention threshold. Place at least 100 mm^2 of copper on the top layer directly under the EP, with thermal vias to inner ground planes, to keep junction temperature rise under 50 C at full load.

Per the ST reference design, place the input bulk capacitor (>= 10 uF, 50 V) within 5 mm of the VCC pin, and the LDO output capacitor (>= 1 uF X7R) within 3 mm of the LDO_OUT pin. Route the CQ (IO-Link data) trace as a 50-ohm controlled-impedance microstrip or stripline with continuous ground reference. Keep the high-current OUT traces away from the CQ trace to avoid capacitive coupling of switching transients into the data line.

Do not connect the L6362ATR VCC directly to a 24 V supply without a reverse-polarity protection TVS or P-MOSFET on the high-side - the datasheet lists reverse-polarity protection internally, but sustained overvoltage transients above 36 V can damage the IC. Always include an external TVS (e.g., SMAJ33CA) at the input for IEC 61000-4-2/4/5 surge compliance. Also verify the CONFIG pin (output stage selection) is not left floating - use a 10 kohm pull-up or pull-down tied to VCC/GND, otherwise the output stage defaults are undefined at power-up.

The exposed pad (EP) must be soldered to a continuous ground plane on the PCB for both thermal dissipation and electrical ground return. Use an array of thermal vias (>= 9 vias, 0.3 mm drill, 0.6 mm pitch) directly under the EP to transfer heat to inner copper layers. Avoid routing signal traces through the EP copper pour - keep it as a solid pour to maximize heat spreading. For multilayer boards, stitch the EP ground to all internal ground planes with multiple vias around the perimeter.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
无铅
Yes
无卤
Yes
冲突矿物
Compliant

RoHS compliant per ST product page. AEC-Q100 not applicable - this is an industrial sensor-port IC, not an automotive-grade part. Halogen-free per ST product family datasheet.

数据核验日期: 2026-10-05 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

L6362ATR L6362ATR datasheet STMicroelectronics L6362ATR IO-Link PHY2 transceiver VFDFPN-12 IO-Link transceiver L6362ATR industrial sensor port L6362ATR vs L6362A L6362ATR vs L6360 L6362ATR buy price reel L6362ATR drop-in replacement what protocol does L6362ATR support IO-Link transceiver 24V VFDFPN-12 L6362ATR factory automation L6362ATR COM3 230.4 kbaud

相关元器件 & 术语

STMicroelectronics L6362ATR L6362A L6360 IO-Link PHY2 IEC 61131-9 VFDFPN-12 3-wire connection COM1 COM2 COM3 transceiver industrial sensor factory automation process control 24 V bus linear regulator push-pull driver high-side driver low-side driver reverse-polarity protection thermal shutdown M12 connector
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情