LMR821G-GTR - Low-Power Ground-Sense Op Amp | ROHM
料号: LMR821G-GTR ✓ 量产中LMR821G-GTR 概述
An operational amplifier is an analog integrated circuit that amplifies the voltage difference between its differential inputs. A ground-sense amplifier is used where the measured signal is referenced close to ground, such as in current-shunt monitoring, low-side sensing, and portable instrumentation. This amplifier belongs to the broader operational amplifier, analog IC, and semiconductor hierarchies.
The LMR821G-GTR is specifically identified by ROHM as a low-power ground-sense operational amplifier. Its single-amplifier configuration reduces board area and is suitable for designs that need one sensing channel rather than a dual or quad device. The low-voltage and low-supply-current positioning makes it relevant to compact, battery-powered, and low-energy measurement systems.
The LMR821G product family emphasizes low-voltage operation and low supply current. These characteristics help reduce the energy required when the amplifier remains connected to a low-capacity power source. Exact input-voltage limits, output-current capability, offset voltage, noise, bandwidth, and open-loop gain should be taken from the ROHM LMR821G datasheet when setting circuit operating points.
Typical uses include low-side current detection, portable sensor interfaces, battery monitoring, and low-voltage signal conditioning. In these applications, the amplifier boosts a small ground-referenced differential signal while adding only modest circuit overhead. Its 5-pin surface-mount package also supports compact layouts, although pad geometry and exposed thermal-pad details must be confirmed against the package drawing.
Use the manufacturer pin-description table when assigning PCB tracks because the complete numbered pin list is not included in the product-page summary. Confirm input common-mode range, output swing, unity-gain stability, and recommended external components before finalizing a high-gain or precision design.
This page combines the manufacturer product information, exact-MPN distributor records, package details, application guidance, and engineering selection notes in one searchable reference. It is intended to accelerate sourcing and initial circuit assessment, while final qualification should follow the complete ROHM datasheet and application circuits.
直接替换替代料: LMR821G-GTR ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
该产品暂无直接替换替代料。
请求替代料LMR821G-GTR 最大额定值与电气特性
| Product Type | Operational amplifier |
| Amplifier Configuration | 1 circuit |
| Operating Class | Standard (general purpose) |
| Application Category | Low-power ground-sense operational amplifier |
| 封装 | 5-SSOP, SC-74A, SOT-753 |
| 安装类型 | Surface mount |
LMR821G-GTR 5-ssop, sc-74a, sot-753 引脚配置指南
LMR821G-GTR(5-ssop, sc-74a, sot-753 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: LMR821G-GTR.
请参阅 数据手册 以查看完整引脚配置。
典型应用
LMR821G-GTR 适用于 6 应用s: Low-Side Current Sensing, Portable Sensor Interfacing, Battery-Powered Monitoring, Industrial Process Measurement, Low-Voltage Control Loops, Portable Instrumentation.
Low-Side Current Sensing
The LMR821G-GTR is appropriate for amplifying a small voltage developed across a low-side shunt, where the signal is referenced near ground. Its one-circuit ground-sense architecture concentrates the active amplifier in a compact 5-SSOP package, while the low-voltage and low-supply-current positioning supports efficient measurement paths. Before finalizing the shunt stage, verify the amplifier input common-mode range, offset voltage, input bias current, and noise against the ROHM datasheet. Also confirm that the shunt resistance and amplifier gain keep the output within the available output swing while providing adequate resolution for the target current.
Portable Sensor Interfacing
The LMR821G-GTR can serve as the analog gain stage for a compact, battery-powered sensor interface when the sensor produces a small ground-referenced signal. Its low-voltage and low-supply-current characteristics are useful when every milliamp of amplifier demand affects the available energy budget. The single amplifier in a 5-SSOP package also reduces board footprint compared with a dual or quad alternative. Confirm the sensor output range, supply voltage, signal bandwidth, and required noise performance. A practical design should also evaluate input bias current so that high-impedance sensor nodes are not excessively loaded.
Battery-Powered Monitoring
For battery-operated monitoring electronics, the LMR821G-GTR provides a low-power path for conditioning a ground-referenced measurement signal. Its low-voltage operating orientation fits systems where the available supply is limited, and the single-amplifier configuration avoids allocating unused channels. Use it when the measured quantity produces a differential voltage close to ground and the required bandwidth can be met. The ROHM datasheet should establish the minimum supply voltage, common-mode limits, quiescent demand, and output behavior before the battery budget is approved. Pair the amplifier with suitably stable reference and sensing components.
Industrial Process Measurement
The LMR821G-GTR is relevant to compact industrial signal-conditioning modules that measure a small differential voltage near the system ground. Its one-circuit format is efficient for dedicated single-channel measurement nodes, and the 5-SSOP surface-mount package supports automated PCB assembly. Ground-sense use can simplify sensing from low-side shunts or grounded transducers. For industrial deployment, confirm the device's operating-temperature range, input and output limits, noise, offset, and electromagnetic-immunity needs. Printed-circuit layout must keep sensing traces away from switching nodes, and grounding must preserve the low-level signal path.
Low-Voltage Control Loops
The LMR821G-GTR can amplify error or feedback signals in a low-voltage control system where the controlled node is referenced close to ground. The low-power characterization is beneficial when the amplifier must remain active continuously, while the single-circuit package leaves room for additional control functions on the same board. Validate loop stability, bandwidth, slew rate, output swing, and phase margin before using it inside a feedback regulator or servo path. The amplifier's ground-referenced role also makes trace routing and reference-ground continuity important because poor ground separation can undermine the benefit of the internal signal-conditioning stage.
Portable Instrumentation
The LMR821G-GTR is suitable for compact handheld or field-test instrumentation that conditions a low-level differential signal without requiring a high-power amplifier. Its single-circuit, 5-SSOP configuration is useful when board area and supply demand are constrained, while low-voltage operation supports portable power architectures. Determine whether the measured source requires rail-to-rail input or output behavior by checking the manufacturer limits rather than assuming those characteristics. Account for offset and noise when calculating the smallest resolvable input. A solid reference design should include local supply bypassing, careful shunt grounding, and protection appropriate to the external sensor wiring.
工程参考数据: LMR821G-GTR ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Brand | ROHM Semiconductor |
| Package | 5-SSOP, SC-74A, SOT-753 |
| Product Type | Ground-sense operational amplifier |
| Amplifier Configuration | 1 circuit |
| Operating Class | Standard (general purpose) |
设计说明
Use the manufacturer pin-description table to assign PCB tracks, and keep the five-SSOP footprint geometry consistent with the SC-74A or SOT-753 package drawing. Place input, output, supply, and ground connections so the low-level differential input path is not forced to share a long trace with a switching or high-current return. A short, direct input route reduces susceptibility to coupling and helps preserve the benefit of the ground-sense architecture.
Separate the sensitive input node from power-converter switches, inductors, and fast digital edges. If the LMR821G-GTR senses a low-side shunt, return the amplifier reference current through a low-impedance path associated with the shunt rather than allowing unrelated ground currents to add to the measured voltage. Ground separation must still preserve a common reference, so model both measurement accuracy and ground bounce before finalizing the board layout.
Confirm the minimum supply voltage, quiescent current, input common-mode range, and output swing from the ROHM datasheet before setting the operating point. The device's low-power and low-voltage positioning does not by itself guarantee operation throughout a battery-discharge range. Add local supply bypass near the amplifier and include the amplifier's contribution in the complete power budget, especially for continuously enabled portable or industrial monitoring systems.
合规信息
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status is stated for the exact LMR821G-GTR.