Analog Devices

LT3669EUFD-2#TRPBF - IO-Link Transceiver with Dual Regulators

料号: LT3669EUFD-2#TRPBF ✓ 量产中
有现货 1-3 个工作日内发货
Up to 300 mA Id 28-QFN (4x5 mm) Package
联系我们 询价
最小起订量: 1 |
价格更新于: 2026-10-22
批量定价
数量 单价 小计
1 $5.38 $5.38
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 所有价格均以 USD 计价

LT3669EUFD-2#TRPBF 概述

The Analog Devices LT3669EUFD-2#TRPBF is a 1/1 IO-Link industrial transceiver with an integrated step-down switching regulator and low-dropout regulator, housed in a 28-lead 4 mm by 5 mm QFN package. The verified product data identifies the device for surface mounting and reel-and-tape handling, with an operating temperature range of -40°C to 125°C. Its integrated power architecture supports the sensor-side requirements of IO-Link industrial connections while reducing the number of external supply components.

An IO-Link transceiver is an interface IC that connects a microcontroller or PLC-side controller to an industrial point-to-point sensor or actuator link. IO-Link adds standardized digital communication and wake-up or power-control capabilities beyond a conventional simple sensor output. The LT3669 family combines that physical-layer interface with power-conversion functions, placing the transceiver, switching regulator, and LDO in one package.

Verified features include 1/1 transceiver operation, IO-Link functionality, integrated step-down regulation, integrated LDO operation, wake-up detection, and a programmable power-on reset timer for the LT3669 family. The Analog Devices LT3669-2 is listed for up to 300 mA load current and requires an external catch diode, whereas the LT3669 variant integrates the catch diode and is listed for up to 100 mA load current.

The 28-QFN (4x5) exposed-pad package is designed for surface-mount assembly and can provide a compact solution where both signal interface and local power conversion are required. The exposed pad also supports thermal conduction into the PCB, although actual thermal performance depends on copper area, board construction, ambient temperature, and load. Use the manufacturer datasheet for pin functions, recommended external components, electrical limits, timing, and layout details before finalizing a design.

Typical applications include IO-Link sensors, industrial proximity and level sensors, factory automation equipment, PLC-connected actuators, and other 24 V industrial fieldbus nodes. The LT3669EUFD-2#TRPBF is most appropriate when a compact 28-QFN footprint, integrated regulators, and the LT3669-2 external-catch-diode architecture fit the system specification.

Design attention should focus on correct pin mapping, regulator stability, catch-diode selection, exposed-pad thermal management, and separation between sensitive communication traces and switching-power paths. The verified distributor record identifies the part as a 28-QFN (4x5) IO-Link transceiver, but detailed application limits and package dimensions must be confirmed from the official Analog Devices documentation.

This product data combines the verified manufacturer and distributor identity, package information, family-level functional description, commercial source links, and practical design guidance into an engineering-oriented reference for IO-Link transceiver and power-management design.

直接替换替代料: LT3669EUFD-2#TRPBF ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: LT3669EUFD-2#TRPBF (相同外形与封装尺寸) ——差异在于 Package, Product Type, Operating Temperature Range, Package Type, Power-On Reset.

Analog Devices
Package: 28-QFN (4 mm x 5 mm)
Product Type: IO-Link transceiver with integrated step-down regulator and LDO
Package Type: 28-pin QFN with exposed pad
对比 LT3669EUFD-2#TRPBF →
Analog Devices
Package: 28-pin QFN, 4 mm x 5 mm
Product Type: IO-Link transceiver with integrated step-down regulator and LDO
Operating Temperature Range: -40 °C to +125 °C
对比 LT3669EUFD-2#TRPBF →

快速对比工具——选择替代料号进行并排对比:

该产品暂无直接替换替代料。

请求替代料

LT3669EUFD-2#TRPBF 规格参数

Product Type 1/1 IO-Link transceiver with integrated step-down regulator and LDO
Manufacturer Analog Devices
Family LT3669 / LT3669-2
Transceiver Configuration 1/1
接口类型 IO-Link
Power Conversion Integrated step-down switching regulator and low-dropout regulator
LT3669-2 Load Current Up to 300 mA
LT3669 Load Current Up to 100 mA
Wake-Up Detection Included
Power-On Reset Programmable timer
工作温度范围 -40°C to 125°C
封装 28-QFN (4x5 mm)
Package Type 28-WFQFN exposed pad
安装类型 Surface Mount
Shipping Format Reel, TR

LT3669EUFD-2#TRPBF 28-wfqfn exposed pad 引脚配置指南

LT3669EUFD-2#TRPBF(28-wfqfn exposed pad 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

LT3669EUFD-2#TRPBF 的 28-wfqfn exposed pad 封装引脚图

暂无详细引脚数据: LT3669EUFD-2#TRPBF.

请参阅 数据手册 以查看完整引脚配置。

典型应用

LT3669EUFD-2#TRPBF 适用于 6 应用s: Industrial IO-Link Proximity Sensors, PLC-Connected Industrial Sensors, Factory Automation Sensor Hubs, Industrial Level and Flow Sensors, 24 V Industrial Actuator Interfaces, Industrial IO-Link Valve and Valve-Control Nodes.

🏭

Industrial IO-Link Proximity Sensors

The LT3669EUFD-2#TRPBF fits industrial IO-Link proximity-sensor nodes because it combines a 1/1 IO-Link transceiver with local power conversion. The integrated step-down regulator and LDO can reduce the number of supply stages needed around the sensor interface, while wake-up detection supports field-bus power-management behavior. The LT3669-2 variant is listed for up to 300 mA load current and requires an external catch diode, so the sensor-node budget must be checked against that limit. In a typical 24 V industrial installation, the device can interface the sensor to a controller while supporting local regulated power. Final selection requires the complete datasheet electrical limits, pin map, and thermal design.

⚡

PLC-Connected Industrial Sensors

This transceiver is suited to PLC-connected sensor nodes that need both IO-Link communication and regulated auxiliary power. The verified 1/1 transceiver configuration supports a point-to-point industrial interface, while the integrated regulator architecture can simplify power distribution around the sensor. The LT3669-2 family member supports up to 300 mA, which is useful when the node includes more than the transceiver itself, but the external catch diode must be implemented as specified by Analog Devices. Engineers should verify cable-side limits, wake-up timing, power-on reset behavior, and isolation or grounding requirements against the complete application circuit before releasing a PLC module design.

🏭

Factory Automation Sensor Hubs

In a factory automation hub, multiple field devices may require local power regulation alongside robust communication interfaces. LT3669EUFD-2#TRPBF consolidates an IO-Link transceiver, step-down converter, and LDO into one 28-QFN device, which can reduce board partitioning compared with separate blocks. Its -40°C to 125°C operating-temperature specification is appropriate for industrial environments when the surrounding equipment is also qualified. The LT3669-2 external-catch-diode architecture must be respected, and the exposed pad needs adequate PCB thermal design. Use the verified family data as the starting point and consult the manufacturer datasheet for layout, startup, efficiency, and absolute-maximum limits.

🧩

Industrial Level and Flow Sensors

Level and flow sensors often need a local interface that can combine sensor excitation, communication, and regulated power in a compact assembly. The LT3669EUFD-2#TRPBF provides the IO-Link transceiver and integrated step-down regulator and LDO in a 4 mm by 5 mm QFN package, helping constrain board area. Wake-up detection and the programmable power-on reset timer can support orderly recovery and field-bus power control. The part must be evaluated against the sensor's actual load current, startup profile, wiring length, and environmental limits. Because the supplied data does not list detailed sensor-specific thresholds, engineers should not assume compatibility from the IO-Link label alone.

⚡

24 V Industrial Actuator Interfaces

The LT3669EUFD-2#TRPBF can support the interface section of a 24 V industrial actuator node when the actuator requires IO-Link communication and local auxiliary power. Its integrated regulator functions can simplify the power tree, while the transceiver handles the communication channel. The LT3669-2 variant is listed for up to 300 mA load current, so it is more suitable than the 100 mA LT3669 variant when the local load budget requires the higher target, subject to exact datasheet limits. Check inductive actuator transients, protection networks, grounding, and thermal rise before using the device directly next to power-switching stages.

🔧

Industrial IO-Link Valve and Valve-Control Nodes

Valve-control nodes commonly benefit from a compact interface that can manage both field communication and local regulated supply. LT3669EUFD-2#TRPBF integrates those functions in a 28-QFN (4x5) surface-mount package, while wake-up detection can help the node respond to bus-powered operating sequences. The programmable power-on reset timer helps define startup behavior, but the exact delay and system power sequence must be configured according to the official documentation. Use careful partitioning between high-current valve drive circuitry and the sensitive transceiver section. The supplied data does not specify valve-driver ratings, so this device should be treated as the interface and local-power block rather than the actuator power stage.

What is LT3669EUFD-2#TRPBF?
LT3669EUFD-2#TRPBF is an Analog Devices 1/1 IO-Link transceiver with an integrated step-down switching regulator and low-dropout regulator. According to the verified DigiKey listing, it is packaged in a 28-QFN (4x5) surface-mount package. The LT3669 family also provides wake-up detection and a programmable power-on reset timer, making it suitable for industrial sensor and actuator interface nodes.
What package does LT3669EUFD-2#TRPBF use?
LT3669EUFD-2#TRPBF uses a 28-lead QFN package measuring 4 mm by 5 mm. The verified distributor data identifies the package as 28-WFQFN with an exposed pad and surface mounting. The reel-and-tape notation TR indicates the listed shipment format. Pin assignments, exposed-pad connections, land pattern, and thermal design must be confirmed against the Analog Devices datasheet.
What is the operating temperature range of LT3669EUFD-2#TRPBF?
The verified operating temperature range for LT3669EUFD-2#TRPBF is -40°C to 125°C. This range supports use across industrial temperature environments when the system also satisfies the device's electrical and layout requirements. The manufacturer datasheet should be used for temperature-dependent limits, thermal resistance, and application-specific derating. Do not infer that the complete industrial system has the same qualification without checking its other components.
What is the load-current difference between LT3669 and LT3669-2?
The LT3669 variant integrates the catch diode and is listed for up to 100 mA load current, while the LT3669-2 variant requires an external catch diode and is listed for up to 300 mA load current. This difference is confirmed by the Analog Devices family information in the verified data. The higher-current LT3669-2 therefore requires the external diode arrangement specified by the manufacturer and is not electrically identical to LT3669 despite sharing the family concept.
Where can I download the LT3669EUFD-2#TRPBF datasheet PDF?
The official LT3669/LT3669-2 datasheet is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/3669fa.pdf. The verified search data identifies this document as the LT3669/LT3669-2 IO-Link Transceiver with Integrated Step-Down Regulator and LDO datasheet. Use the official document for electrical characteristics, pin descriptions, application circuits, timing, and recommended external components.
Where can I find the LT3669EUFD-2#TRPBF pinout?
The LT3669EUFD-2#TRPBF pinout is found in the official Analog Devices LT3669/LT3669-2 datasheet, available at https://www.analog.com/media/en/technical-documentation/data-sheets/3669fa.pdf. The verified distributor record confirms a 28-QFN (4x5) package, but it does not provide the complete numbered pin map. Do not infer pin functions from package size alone; cross-check every connection, including power, ground, communication, regulator, and exposed-pad functions, before PCB release.
Can LT3669EUFD-2#TRPBF be used in industrial IO-Link sensors?
Yes, LT3669EUFD-2#TRPBF is intended for industrial IO-Link transceiver applications. Its verified feature set includes 1/1 transceiver operation, IO-Link functionality, wake-up detection, an integrated step-down regulator, an integrated LDO, and a programmable power-on reset timer. The LT3669-2 family variant supports up to 300 mA load current but requires an external catch diode, so the complete sensor-node power design must follow the manufacturer application guidance.
What is the power architecture inside LT3669EUFD-2#TRPBF?
LT3669EUFD-2#TRPBF combines an IO-Link transceiver with a step-down switching regulator and a low-dropout regulator. This integrated architecture is intended to support local sensor-side power while also handling the communication interface. The verified data does not provide every voltage, frequency, efficiency, or output-current specification for the target package, so those values must be taken from the official LT3669/LT3669-2 datasheet rather than estimated.
Where can I buy LT3669EUFD-2#TRPBF online?
LT3669EUFD-2#TRPBF can be found through authorized electronics distributors, including DigiKey and Mouser, with part-specific pages available in the verified sources. The Analog Devices product page also provides sample and buy links. The verified DigiKey listing states that the part ships today, but availability and lead time can change. Request a current quote and confirm the exact suffix, package, and authorized supply before placing an order.
What is the price of LT3669EUFD-2#TRPBF?
The verified Analog Devices product search result lists LT3669-2 pricing starting from $5.38 for a 1,000-unit quantity. The supplied data does not provide verified price breaks for 1, 10, 100, 500, and 1,000 units, so those tiers remain marked as data needed. Pricing is a point-in-time commercial value and should be reconfirmed with the distributor as of the purchase date.
What is the lead time for LT3669EUFD-2#TRPBF?
The verified DigiKey listing states that LT3669EUFD-2#TRPBF ships today, which indicates current listing availability but does not provide a guaranteed lead time for every quantity or every order. For production planning, request a written distributor quotation and confirm stock, scheduled delivery, and the exact LT3669EUFD-2#TRPBF suffix. Lead time can change with inventory, order volume, and distribution conditions.
Is LT3669EUFD-2#TRPBF in stock?
The verified DigiKey listing states “Buy now, ships today” for LT3669EUFD-2#TRPBF, so the listed distributor result indicates current orderability. That statement should not be treated as a permanent inventory guarantee. Confirm live stock and quantity with DigiKey or Mouser at the time of purchase, especially when scheduling a larger production run or using an exact manufacturing date.
Can LT3669EUFD-2#TRPBF replace LT3669EUFD-2#PBF?
LT3669EUFD-2#TRPBF and LT3669EUFD-2#PBF are closely related catalog entries with the same -2 device family and 28-QFN (4x5) package designation. However, the verified data does not establish that every electrical, marking, ordering, or thermal detail is identical between the two suffix variants. Treat them as sourcing alternatives only after confirming the manufacturer pinout, order code, package drawing, and lifecycle terms in the official datasheet and product records.
What is the best drop-in replacement for LT3669EUFD-2#TRPBF?
No verified drop-in replacement with five or more confirmed same-package alternatives is provided in the supplied data. The LT3669/LT3669-2 family information identifies functional variants, but it does not establish a complete pin-compatible replacement list for LT3669EUFD-2#TRPBF. A valid replacement must match the 28-QFN footprint, pin functions, electrical limits, regulator architecture, and external catch-diode requirements. Use the official family datasheet and distributor cross-reference tools for qualification.
What is the difference between LT3669EUFD#TRPBF and LT3669EUFD-2#TRPBF?
The principal verified difference is the power-conversion implementation and load-current target. LT3669 integrates the catch diode and is listed for up to 100 mA, whereas LT3669-2 requires an external catch diode and is listed for up to 300 mA. Both belong to the LT3669 IO-Link transceiver family with integrated step-down regulator and LDO. They should not be treated as automatic drop-in equivalents because the external diode requirement differs.
Are LT3669EUFD-2#TRPBF and LT3669EUFD-2#PBF compatible alternatives?
The two MPNs share the LT3669EUFD-2 base designation and are both listed by DigiKey in 28-QFN (4x5), but the supplied sources do not explicitly confirm that they are pin-to-pin drop-in replacements. Differences in order suffix, packaging, marking, or commercial terms may apply. Before substitution, compare the exact Analog Devices ordering information, pin configuration, exposed-pad connection, and electrical specifications. Commercial similarity alone does not establish replacement qualification.
How should the LT3669EUFD-2#TRPBF PCB layout be designed?
Place the transceiver and integrated power-conversion components according to the Analog Devices recommended layout, keeping communication traces and switching-power paths appropriately controlled. The verified package is a 28-QFN (4x5) with an exposed pad and requires surface-mount assembly. Follow the datasheet for pin placement, component proximity, grounding, and exposed-pad connections. Do not rely on a generic QFN land pattern because exposed-pad and thermal requirements are package-specific.

工程参考数据: LT3669EUFD-2#TRPBF ——对比、设计指导和合规信息。

选型指南

Choose LT3669EUFD-2#TRPBF when the design needs an IO-Link transceiver with integrated step-down and LDO functions, a 28-QFN (4x5) footprint, and the higher 300 mA family load-current target. Choose LT3669EUFD or LT3669EUFD#TRPBF only when the lower 100 mA target and integrated catch diode match the system; those variants are not automatically interchangeable because their external diode requirements differ. LT3669EUFD-2#PBF may be useful as a sourcing alternative because it shares the -2 family and package designation, but confirm exact ordering, marking, pinout, and lifecycle terms. No unrelated cross-brand part should be selected without verified same-package pin and electrical equivalence.

与替代料对比

参数 本产品 LT3669EUFD-2#PBF LT3669EUFD#PBF LT3669EUFD#TRPBF
Package 28-QFN (4x5) 28-QFN (4x5) 28-QFN (4x5) 28-QFN (4x5)
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Interface IO-Link IO-Link IO-Link IO-Link
Integrated Power Functions Step-down switching regulator and LDO Step-down switching regulator and LDO Step-down switching regulator and LDO Step-down switching regulator and LDO
Catch-Diode Requirement External catch diode required External catch diode required Catch diode integrated Catch diode integrated

关键差异点

  • Higher listed load-current target than the integrated-diode LT3669 variant (对比 LT3669EUFD#PBF)
  • External catch-diode architecture (对比 LT3669EUFD#TRPBF)
  • Integrated IO-Link interface and local power conversion (对比 LT3669EUFD-2#PBF)

设计说明

The LT3669-2 architecture requires an external catch diode according to the verified Analog Devices family data. Select that diode and its placement using the official recommended application circuit, because incorrect orientation or placement can increase switching stress and reduce regulator performance. Keep the power-loop current path short and keep the catch-diode return close to the regulator ground reference. Do not use the LT3669 integrated-diode variant as a reference for the LT3669-2 layout without checking the datasheet difference.

Treat the 28-QFN (4x5) exposed pad as both an electrical and thermal feature. Confirm the exposed-pad connection and land pattern from the Analog Devices package drawing, then provide a controlled copper path to the board ground or thermal reference specified by the device. The supplied data does not include the exact pad dimensions or recommended footprint, so a generic QFN footprint is not sufficient for production layout. Review assembly land patterns with the selected PCB manufacturer.

Separate the IO-Link communication traces from the high-current switching-regulator path where practical. Route signal returns without crossing noisy power-current loops, and use the datasheet-recommended component placement to minimize parasitic inductance and switching disturbance. Wake-up detect and power-on reset timing are sensitive to supply and network conditions, so debug the complete startup sequence rather than evaluating only steady-state communication. Grounding, return-current control, and connector placement should be reviewed together.

Do not substitute LT3669EUFD and LT3669EUFD-2 solely because both are listed in the same family. The verified data states that LT3669 integrates the catch diode and targets up to 100 mA, while LT3669-2 requires an external catch diode and targets up to 300 mA. A design that assumes the integrated-diode arrangement can therefore fail electrically or require PCB changes. Confirm the exact MPN, external diode, package pinout, and load budget before release.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied manufacturer and distributor data confirms the component identity, industrial IO-Link function, package, and operating temperature range but does not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.

相关搜索

LT3669EUFD-2#TRPBF LT3669EUFD-2#TRPBF datasheet Analog Devices LT3669 IO-Link transceiver LT3669EUFD-2 28-QFN 4x5 LT3669-2 external catch diode LT3669 EUFD 300 mA IO-Link LT3669EUFD-2 industrial sensor interface LT3669EUFD-2 vs LT3669EUFD LT3669EUFD-2 drop-in replacement LT3669EUFD-2#TRPBF price LT3669EUFD-2#TRPBF stock LT3669EUFD-2#TRPBF pinout 28-QFN IO-Link transceiver with LDO LT3669EUFD-2#PBF

相关元器件 & 术语

Analog Devices LT3669EUFD-2#TRPBF LT3669EUFD-2#PBF LT3669EUFD#PBF LT3669EUFD#TRPBF IO-Link industrial transceiver step-down switching regulator low-dropout regulator LDO wake-up detection power-on reset timer 28-QFN 4x5 mm QFN surface mount exposed pad external catch diode industrial sensor factory automation PLC-connected equipment power management IC semiconductor 300 mA -40°C to 125°C
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情