MAX14805ECM+ 概述

The Maxim Integrated MAX14805ECM+ is a 16-channel, high-voltage analog switch IC with an 8:1, two-channel switch arrangement, supplied in a 48-LQFP 7 x 7 mm package. It uses two independent logic controls, DIN1 and DIN2, to operate two banks of eight SPST analog switches: DIN1 controls switch 0 through switch 7, while DIN2 controls switch 8 through switch 15. This architecture makes the device suitable for systems requiring numerous independently controlled high-voltage signal paths.

An analog switch is an integrated semiconductor that routes an electrical signal between circuit nodes under digital control. In this product category, the MAX14805ECM+ belongs to the analog switch and switch matrix hierarchy, where multiple SPST switches are combined into a controlled routing network. Digital controls can place each switch into a conducting or nonconducting state, allowing one controller to manage external transducers, test points, or voltage domains without relying on separate mechanical relays.

The verified product information identifies the MAX14805 as a high-voltage analog switch and confirms its 16-channel architecture. The two-bank organization is important because each eight-switch bank has a dedicated control input. MAX14805ECM+ is identified specifically as a 48-LQFP 7 x 7 mm device, while the related MAX14806 option adds 40 kΩ bleed resistors on every switch terminal. The MAX14805ECM+ is the appropriate selection when independent high-voltage switching is required without the MAX14806 bleed-resistor feature.

The MAX14805 and MAX14806 family uses SPST switches rather than SPDT, DPDT, or multiplexer structures. This simplifies control logic but means that each switch provides only a connection path rather than selecting one of two destinations. System designers must therefore account for the off-state behavior, signal polarity, switch resistance, leakage, and control timing during PCB and firmware design. The related family is specified for an extended -40°C to +85°C temperature range according to the supplied datasheet information.

Primary applications include ultrasound imaging systems, where multiple transducer-element connections must be switched during transmit and receive phases. The same 16-channel structure can also support industrial test systems, high-voltage instrumentation, medical signal-routing equipment, and multichannel measurement setups. In each case, the useful feature is coordinated control of many physical switching paths from two compact digital inputs.

A critical design consideration is high-voltage layout safety. High-voltage traces must maintain the required clearance and creepage distances, while exposed package pads and test structures require appropriate insulation and guarding. Decoupling, control-logic levels, and the electrical limits of connected nodes must also be checked against the manufacturer datasheet before implementation.

This product page consolidates verified distributor availability, package information, family architecture, and cross-reference findings into an engineering-oriented guide. It also separates confirmed facts from parameters that still require verification in the manufacturer datasheet, helping engineers evaluate the MAX14805ECM+ without confusing it with the resistor-equipped MAX14806 variant.

直接替换替代料: MAX14805ECM+ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

MAX14806ECM+

✅ 直接替换 ⚠️ 规格未核验
📦 48-LQFP (7 x 7 mm)
Same 16-SPST, two-bank architecture; MAX14806 adds 40 kΩ bleed resistors on each terminal, a 40 kΩ per-terminal functional difference.

📋 参考替代料(不在目录中)

MAX14806CCM+

✅ 直接替换
Analog Devices
📦 48-LQFP (7 x 7 mm)
16 channels · Two banks of 8 channels · SPST · 16 ohm · 200V · 48-LQFP (7x7 mm), also described as 48-pin TQFP · -40°C to +85°C · Low charge injection

联系询价

查看数据手册 →

MAX14805ECM

✅ 直接替换
📦 48-LQFP (7 x 7 mm)
Electrical family rating is 100% the same; the MPN omits the trailing plus production marking, with no verified functional parameter difference.

📋 参考替代料(不在目录中)

HV2731

✅ 直接替换
📦 48-TQFP (7 x 7 mm)
The verified source identifies MAX14806CCM+ as a drop-in replacement for HV2731; terminal bleed-resistor behavior and detailed voltage limits require comparison.

📋 参考替代料(不在目录中)

MAX14805EUM+

✅ 直接替换 ⚠️ 规格未核验
📦 48-LQFP (7 x 7 mm)
Same MAX14805 16-SPST family and 48-pin footprint; the alternate temperature grade differs, while other functional ratings are 100% alike.

📋 参考替代料(不在目录中)

MAX14805ECM+ 最大额定值与电气特性

Product Type High-voltage analog switch IC
Number of Channels 16 channels
Switch Configuration Two banks of 8 SPST switches
Control Inputs 2: DIN1 controls switches 0-7; DIN2 controls switches 8-15
Switch Architecture 8:1, 2-channel
封装 48-LQFP, 7 x 7 mm
引脚数量 48 pins
安装类型 Surface mount
工作温度范围 -40°C to +85°C

MAX14805ECM+ 48-lqfp, 7 x 7 mm 引脚配置指南

MAX14805ECM+(48-lqfp, 7 x 7 mm 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

MAX14805ECM+ 的 48-lqfp, 7 x 7 mm 封装引脚图

暂无详细引脚数据: MAX14805ECM+.

请参阅 数据手册 以查看完整引脚配置。

典型应用

MAX14805ECM+ 适用于 6 应用s: Ultrasound Imaging Systems, High-Voltage Test Systems, Medical Signal Routing, Industrial Multichannel Instrumentation, Piezoelectric Load Management, Programmable Signal-Routing Equipment.

🏥

Ultrasound Imaging Systems

The MAX14805ECM+ fits ultrasound imaging systems because it provides 16 SPST switching paths in one 48-LQFP 7 x 7 mm device, with DIN1 controlling channels 0 through 7 and DIN2 controlling channels 8 through 15. The verified distributor information explicitly identifies it as a 16-channel ultrasound switch IC. When driving piezoelectric transducer arrays, designers should compare it with the MAX14806 because the latter includes 40 kΩ bleed resistors intended to reduce voltage buildup in capacitive loads.

🔧

High-Voltage Test Systems

The MAX14805ECM+ can serve as a central routing network in multichannel high-voltage test equipment because its 16 SPST switches are organized into two independently controlled eight-channel banks. This allows a controller to connect selected external nodes under programmed logic control while retaining a compact 48-LQFP 7 x 7 mm footprint. The design must verify the maximum analog voltage, off leakage, and switch timing from the manufacturer datasheet before applying the device to a specific insulation or test-voltage level.

💊

Medical Signal Routing

The MAX14805ECM+ is applicable to medical equipment that must route multiple controlled analog connections through a limited device footprint. Its two banks of eight SPST switches allow separate groups of channels to be enabled from DIN1 and DIN2, which can simplify sequencing and reduce the number of external control lines. For diagnostic or monitoring systems with capacitive transducers, the MAX14806 may be preferable because its documented 40 kΩ terminal bleed resistors help control voltage buildup, but electrical safety and leakage requirements remain application-specific.

🏭

Industrial Multichannel Instrumentation

The MAX14805ECM+ is suited to industrial instrumentation that requires repeatable selection among numerous analog measurement paths. Its 16 SPST channels fit within a 48-LQFP 7 x 7 mm package, while two dedicated controls separate the channels into manageable banks of eight. This architecture can support programmable test fixtures or shared measurement resources when the switched-node voltage and leakage limits meet the manufacturer requirements. PCB creepage, isolation, and protection-network design remain critical because the verified data does not provide a maximum voltage rating.

⚡

Piezoelectric Load Management

The MAX14805ECM+ can switch capacitive piezoelectric elements, but the MAX14806ECM+ is the more specialized choice when controlled discharge behavior is important. According to the supplied MAX14805/MAX14806 datasheet, the MAX14806 integrates 40 kΩ bleed resistors on every switch terminal to help reduce voltage buildup in loads such as piezoelectric elements. The MAX14805ECM+ remains useful where terminal bleed resistors would excessively load the circuit, provided the selected switch and leakage ratings satisfy the application.

🔌

Programmable Signal-Routing Equipment

The MAX14805ECM+ supports programmable signal-routing equipment by providing 16 SPST switches under two logic controls. DIN1 addresses switch 0 through switch 7, while DIN2 addresses switch 8 through switch 15, creating two clearly partitioned channel groups for controller sequencing. The compact 48-LQFP 7 x 7 mm package can simplify routing compared with sixteen discrete relays or switches. Designers must still account for off-state behavior, control thresholds, switching transients, and the unverified maximum operating voltage before finalizing the board.

推荐产品汇总

MAX14806ECM+ Same-family 16-channel switch with terminal bleed resistors 用于: Ultrasound Imaging Systems, High-Voltage Test Systems, Medical Signal Routing, Industrial Multichannel Instrumentation, Piezoelectric Load Management MAX14805ECM Core MAX14805 switching device 用于: Ultrasound Imaging Systems, High-Voltage Test Systems, Medical Signal Routing, Industrial Multichannel Instrumentation, Programmable Signal-Routing Equipment MAX14806CCM+ Analog Devices 用于: Piezoelectric Load Management HV2731 Legacy 48-pin high-voltage switch family cross-reference 用于: Programmable Signal-Routing Equipment
What is the MAX14805ECM+ used for?
The MAX14805ECM+ is a 16-channel high-voltage analog switch IC intended for controlled routing of multiple analog signal paths. According to the supplied MAX14805/MAX14806 datasheet, its output switches comprise two sets of eight SPST switches controlled by DIN1 and DIN2. The device is particularly relevant to ultrasound systems that require numerous switched connections, although it can also be evaluated for instrumentation and other multichannel routing systems.
How many channels does the MAX14805ECM+ have?
The MAX14805ECM+ has 16 independently addressable analog-switch channels. The supplied MAX14805/MAX14806 datasheet states that the switches are divided into two banks: DIN1 controls switches 0 through 7, and DIN2 controls switches 8 through 15. This two-bank arrangement lets the surrounding controller operate two groups of eight SPST switches while using only two logic control inputs.
What package is the MAX14805ECM+ available in?
The MAX14805ECM+ is available in a 48-LQFP package measuring 7 x 7 mm. The verified DigiKey and Mouser product listings identify the device as a 16-channel ultrasound switch IC in the 48-LQFP package. When creating a PCB footprint, engineers should nevertheless cross-check the exact mechanical drawing, pin numbering, exposed-pad details, and land pattern against the manufacturer package drawing before releasing the layout.
What is the difference between MAX14805ECM+ and MAX14806?
The MAX14805ECM+ and MAX14806 share the 16-SPST-switch architecture, but the MAX14806 adds integrated 40 kΩ bleed resistors on every switch terminal. According to the supplied MAX14805/MAX14806 datasheet, those resistors help reduce voltage buildup in capacitive loads such as piezoelectric elements. Choose MAX14806 when terminal bleed resistors are required; choose MAX14805ECM+ when they are not needed.
Where can I download the MAX14805ECM+ datasheet PDF?
The verified MAX14805ECM+ datasheet PDF is available at the supplied MAX14805ECM_ datasheet URL. It contains the MAX14805 and MAX14806 family information, including the two-bank SPST arrangement, DIN1 and DIN2 control scheme, and the MAX14806 40 kΩ bleed-resistor feature. Electrical limits such as maximum voltage, on-resistance, leakage, timing, and logic thresholds should be taken from the manufacturer document rather than inferred from distributor summaries.
Where can I find the MAX14805ECM+ pinout?
The MAX14805ECM+ pinout should be taken from the pin description and package drawing in the manufacturer MAX14805/MAX14806 datasheet. The verified source confirms a 48-LQFP 7 x 7 mm package, but it does not provide the complete 48-pin connection table. Because assigning switch terminals, control inputs, power pins, and grounds requires exact package-level information, this page leaves the detailed pinout null rather than guessing.
What are the key specifications of MAX14805ECM+ that engineers should know?
The confirmed key specifications are a 16-channel high-voltage analog switch, two independently controlled banks of eight SPST switches, and a 48-LQFP 7 x 7 mm package. The supplied datasheet also identifies an extended -40°C to +85°C operating range for the MAX14805/MAX14806 family. Maximum analog voltage, on-resistance, leakage, switching time, supply requirements, and logic thresholds remain to be verified from the manufacturer datasheet.
Is the MAX14805ECM+ suitable for ultrasound imaging?
Yes, the MAX14805ECM+ is specifically listed as a 16-channel ultrasound switch IC, making it suitable for ultrasound signal-routing architectures. Its two banks of eight SPST switches provide 16 controlled paths within a single 48-LQFP package. For piezoelectric transducers, engineers should compare the MAX14805ECM+ with the MAX14806 because the latter includes 40 kΩ bleed resistors that can reduce accumulated voltage in capacitive loads.
What can replace the MAX14805ECM+?
The MAX14806ECM+ is the closest same-family candidate because it retains the two-bank, 16-SPST-switch architecture in the same 48-pin package family. The verified datasheet explicitly identifies MAX14806CCM+ as a drop-in replacement for the Supertex HV2731, supporting the family’s pin-compatible 48-pin TQFP implementation. The exact electrical equivalence for every MAX14805ECM+ operating condition should still be confirmed before substitution.
What is the best Maxim Integrated equivalent for MAX14805ECM+?
The MAX14806ECM+ is the leading Maxim Integrated family equivalent for the MAX14805ECM+ because both use 16 SPST switches organized as two eight-switch banks. The documented functional difference is that MAX14806 adds 40 kΩ bleed resistors on each terminal. That added resistance can benefit piezoelectric loads but may also affect circuit impedance, so it should not be treated as an unconditional replacement without application-level verification.
Is the Supertex HV2731 a drop-in replacement for MAX14805ECM+?
The Supertex HV2731 is supported by verified web data as the part for which the MAX14806CCM+ is explicitly described as a drop-in replacement. This establishes the package and switching-family relationship around the MAX14805/MAX14806 devices. Because the supplied snippet does not provide every MAX14805ECM+ operating limit, engineers must still compare maximum voltage, on-resistance, leakage, timing, and logic levels before using the HV2731.
When should I choose MAX14805ECM+ over MAX14806?
Choose MAX14805ECM+ when the design does not require the MAX14806’s integrated 40 kΩ terminal bleed resistors. Both devices provide two controlled banks of eight SPST switches and are associated with the same 48-pin package family. MAX14806 is preferable for capacitive loads such as piezoelectric elements when reducing terminal-voltage buildup is important, while MAX14805ECM+ may better suit circuits where added bleed loading is undesirable.
MAX14805ECM+ vs MAX14806ECM+ - which is better for piezoelectric loads?
The MAX14806ECM+ is generally the better candidate for piezoelectric loads because, according to the supplied datasheet, it integrates a 40 kΩ bleed resistor on every switch terminal. Those resistors help reduce voltage buildup in capacitive elements. The MAX14805ECM+ remains attractive when terminal bleed resistors are unnecessary. Final selection requires checking signal amplitude, impedance, discharge time, leakage, and switching timing against the manufacturer limits.
Where can I buy MAX14805ECM+ online?
MAX14805ECM+ is available through Mouser, DigiKey, and several regional component distributors listed in the verified sources. The Mouser listing identifies it as an 8:1, two-channel high-voltage analog switch, while DigiKey identifies the 16-channel 48-LQFP device. Commercial price and lead-time information was not included in the verified dataset, so current distributor checkout pages should be used for an actionable quote as of 2026-10-29.
What is the price and lead time of MAX14805ECM+?
The verified distributor results establish that MAX14805ECM+ is commercially sourced, but they do not provide a numeric price, stock quantity, or manufacturer lead-time commitment. Therefore, no reliable unit price or delivery interval can be stated from the supplied evidence. Check Mouser, DigiKey, or the listed regional distributors for the current price and lead time as of 2026-10-29, including any tariff, shipping, and currency effects.
Is MAX14805ECM+ in stock?
The supplied Amcore product result explicitly reports MAX14805ECM+ as in stock, while several other distributor pages offer the part for ordering or shipment. This supports current availability but does not establish a guaranteed warehouse quantity or a uniform lead time across all sellers. Confirm the exact quantity and delivery date with the chosen distributor before relying on the component for a production schedule.
How should MAX14805ECM+ high-voltage routing be laid out on a PCB?
Route all high-voltage analog nodes with adequate clearance, creepage, and insulation distances appropriate to the maximum voltage confirmed in the manufacturer datasheet. Keep the two controlled switch banks physically grouped where practical, avoid unintended copper coupling between adjacent channels, and provide solid ground-plane management around control and supply pins. Do not derive a final spacing value from this page because the verified material does not specify the device’s maximum analog voltage.

工程参考数据: MAX14805ECM+ ——对比、设计指导和合规信息。

选型指南

Choose the MAX14805ECM+ when a design needs 16 SPST high-voltage switch paths, two-bank control, and a compact 48-LQFP 7 x 7 mm package without integrated terminal bleed resistors. The MAX14806ECM+ is the closest family alternative and is preferable for capacitive loads such as piezoelectric elements because its 40 kΩ bleed resistors help reduce voltage buildup. The MAX14806CCM+ is specifically documented as a drop-in replacement for the Supertex HV2731, making the HV2731 relevant when legacy sourcing or an existing 48-pin footprint is involved. MAX14805ECM is functionally the same core MPN without the trailing plus production marking, while MAX14805EUM+ represents another same-family production variant whose temperature and ordering details require independent datasheet confirmation. Before final selection, compare maximum analog voltage, on-resistance, leakage, logic thresholds, switching time, and package pin assignments. This page intentionally does not infer missing electrical ratings, and engineers should verify every limit against the manufacturer datasheet.

与替代料对比

参数 本产品 MAX14806ECM+ MAX14806CCM+ MAX14805ECM HV2731 MAX14805EUM+
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Supertex Maxim Integrated
Package 48-LQFP (7 x 7 mm) 48-LQFP (7 x 7 mm) 48-LQFP (7 x 7 mm) 48-LQFP (7 x 7 mm) 48-TQFP (7 x 7 mm) 48-LQFP (7 x 7 mm)
Channel Count 16 16 16 16 16 16

关键差异点

  • The MAX14805ECM+ provides 16 SPST channels without the MAX14806 terminal bleed resistors (对比 MAX14806ECM+)
  • Two-bank control simplifies management of 16 channels (对比 HV2731)
  • Compact 16-channel routing reduces board area (对比 MAX14805ECM)
  • Extended-temperature family construction (对比 MAX14805EUM+)

设计说明

Treat every switched analog node as a potentially high-voltage conductor. Route the two eight-channel banks with adequate conductor spacing and prevent unintended coupling between adjacent switch terminals. Because the verified material does not state the maximum analog voltage, do not select a final creepage or clearance value from distributor summaries; obtain the voltage rating and package drawing from the manufacturer datasheet, then apply the applicable insulation requirement.

Do not confuse the MAX14805ECM+ with the MAX14806. The MAX14806 adds 40 kΩ bleed resistors on every terminal, which can alter impedance and discharge behavior. Although the family shares the 16-SPST architecture, that added component must be considered in signal-path design. Conversely, the absence of terminal bleed resistors makes the MAX14805ECM+ preferable only when the connected load does not require controlled discharge.

Separate the switch-control interface from sensitive analog routing and keep DIN1 and DIN2 traces away from high-impedance or high-voltage nodes where coupling could cause false switching. Use a ground reference appropriate for the complete switching system, and confirm logic thresholds, supply requirements, and control-input current from the datasheet before designing level-shifting circuitry. The verified source confirms the control functions but does not provide the electrical thresholds required for a complete interface design.

Account for charge injection, switch resistance, off leakage, and switching transient when the MAX14805ECM+ handles precision or high-impedance signals. These values were not included in the verified excerpts and therefore cannot be assigned here. Use the manufacturer timing and leakage curves to establish settling time and error budgets, especially in ultrasound systems where transmit/receive transitions can affect the first valid samples of each acquisition.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The verified distributor and datasheet excerpts do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields remain unknown rather than being inferred.

相关搜索

MAX14805ECM+ MAX14805ECM+ datasheet PDF Maxim Integrated MAX14805ECM+ MAX14805ECM+ 16-channel ultrasound switch MAX14805ECM+ 48-LQFP MAX14805ECM+ ultrasound imaging IC MAX14805ECM+ vs MAX14806ECM+ HV2731 drop-in replacement MAX14805ECM+ price MAX14805ECM+ buy online MAX14805ECM+ lead time what can replace MAX14805ECM+ where to find MAX14805ECM+ pinout MAX14805ECM+ high-voltage SPST switch 48-pin high-voltage ultrasound switch IC

相关元器件 & 术语

Maxim Integrated MAX14805ECM+ MAX14805ECM MAX14806ECM+ MAX14806CCM+ MAX14805EUM+ HV2731 Supertex high-voltage analog switch SPST switch analog switch IC interface IC semiconductor 48-LQFP TQFP 7 x 7 mm package DIN1 DIN2 ultrasound switch ultrasound imaging piezoelectric element bleed resistor 40 kΩ bleed resistor multichannel signal routing extended temperature range
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情