MAX485CPA+ - Low-Power RS-485/RS-422 Transceiver | Analog Devices
料号: MAX485CPA+ ✓ 量产中| 数量 | 单价 | 小计 |
|---|---|---|
| 1 | $7.3596 | $7.36 |
| 10 | $7.3596 | $73.60 |
| 100 | $7.3596 | $735.96 |
| 500 | $7.3596 | $3,679.80 |
| 1,000 | $7.3596 | $7,359.60 |
MAX485CPA+ 概述
An RS-485/RS-422 transceiver is an interface IC that converts logic-level digital signals into differential bus signals and receives differential signals back from the bus. In this product family, the transceiver combines a transmitter and receiver while supporting half-duplex communication, meaning the shared bus can transmit or receive according to the system design. The MAX485CPA+ belongs to the broader interface-IC and RS-485 transceiver hierarchy, linking digital logic equipment to a physical differential communication network.
Key verified features include a low-power communication architecture, slew-rate-limited signaling, one driver, one receiver, and compatibility with both RS-485 and RS-422 applications. The verified distributor listings identify the package as an 8-pin PDIP and categorize the part as a half-duplex transceiver. The eight-pin package supports through-hole assembly and provides the standard transceiver connections needed for a board-level industrial interface. The official Analog Devices product page describes the MAX485 family as low-power transceivers for RS-485 and RS-422 communication.
The transceiver architecture is important in systems where a controller UART connects to a field bus. The driver presents the outgoing data as a differential signal, while the receiver converts the differential bus state into a logic-level signal for the host. Slew-rate limiting reduces the high-frequency content of transitions, helping control signal integrity on terminated or moderately loaded buses. Designers must still select the correct cable, termination, grounding, and biasing strategy for the installed network.
Typical applications include industrial automation links, remote sensor networks, security equipment, test and measurement systems, building automation controllers, and communication links between embedded processors and external transceivers. A microcontroller or programmable controller can use the MAX485CPA+ to communicate over a longer differential bus instead of relying on a single-ended signal. The design must account for bus direction control, driver enable timing, receiver enable timing, and the electrical limits of the connected network.
For PCB design, place the transceiver close to the connector and route the differential pair with consistent geometry, minimal stubs, and appropriate grounding. Use termination only where required by the bus topology, and verify the cable length, baud rate, node count, and common-mode environment. This page combines verified product descriptions, distributor sourcing information, cross-reference results, and practical interface guidance for engineers evaluating the MAX485CPA+.
直接替换替代料: MAX485CPA+ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MAX485CPA+ (相同外形与封装尺寸) ——差异在于 Mounting Type, Package, RoHS Status.
快速对比工具——选择替代料号进行并排对比:
MAX485EPA
✅ 直接替换📋 参考替代料(不在目录中)
MAX485ECPA
✅ 直接替换📋 参考替代料(不在目录中)
MAX481CPA
✅ 直接替换📋 参考替代料(不在目录中)
SP485CN-L
✅ 直接替换📋 参考替代料(不在目录中)
MAX485CPA
✅ 直接替换📋 参考替代料(不在目录中)
MAX485CPA+ 规格参数
| Product Type | RS-485/RS-422 low-power transceiver |
| Driver Count | 1 |
| Receiver Count | 1 |
| Communication Mode | Half-duplex |
| Supported Standards | RS-485 and RS-422 |
| Signal Type | Differential |
| Slew Rate | Slew-rate-limited |
| 封装 | 8-pin PDIP |
| 安装类型 | Through-hole |
| RoHS 状态 | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
| Lead-Free Status | unknown |
MAX485CPA+ 8-pin pdip 引脚配置指南
MAX485CPA+(8-pin pdip 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: MAX485CPA+.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MAX485CPA+ 适用于 7 应用s: Industrial Automation Bus, Building Automation, Data Acquisition Equipment, Security and Access Control, Test and Measurement, Embedded Serial Communication, Remote Sensor Networks.
Industrial Automation Bus
The MAX485CPA+ fits industrial automation links that need a low-power differential transceiver between a controller and field equipment. Its verified one-driver/one-receiver configuration and half-duplex operation are appropriate for shared buses where only one node drives at a time. The design should include controlled driver-enable timing, termination based on cable topology, and connector-side protection. Because the supplied data does not state maximum data rate or common-mode range, verify those values against the manufacturer datasheet before selecting cable length and baud rate.
推荐
Building Automation
The MAX485CPA+ can connect building-automation controllers, room modules, sensors, and actuators over a wired differential network. The transceiver's RS-485/RS-422 compatibility and slew-rate-limited signaling help support controlled transitions on installed cabling, while the 8-pin PDIP package simplifies through-hole assembly and serviceable industrial equipment. Engineers must verify grounding, cable routing, surge protection, and network topology. The component's verified half-duplex operation means the controller must ensure that multiple nodes do not drive the bus simultaneously.
推荐
Data Acquisition Equipment
The MAX485CPA+ is appropriate for data-acquisition equipment that must carry commands or measurements between an embedded controller and a remote sensor interface. Differential signaling reduces sensitivity to common-mode noise compared with a single-ended interface, while the integrated driver and receiver reduce the number of separate bus components. Keep the transceiver and connector path compact, provide a defined return path, and confirm the receiver and driver electrical limits from the datasheet. The verified source data does not specify input sensitivity or isolation, so those requirements need separate verification.
推荐
Security and Access Control
The MAX485CPA+ can be used in access-control readers, controllers, intercom equipment, and monitoring modules that communicate over a wired differential bus. Its low-power transceiver architecture and half-duplex mode suit systems where a central controller exchanges short messages with field devices. The design should include appropriate transient protection because access-control equipment may connect to longer outdoor or building cables. Verify the exact MAX485CPA+ electrical limits, enable timing, and operating temperature from the manufacturer documentation before production release.
推荐
Test and Measurement
The MAX485CPA+ is useful in test and measurement systems where a controller, instrument, or remote fixture communicates through a differential bus. The receiver converts the bus signal into a logic-level signal, and the driver supports outbound communications, making the part suitable for half-duplex command and response traffic. Lab installations should separate sensitive analog paths from the bus connector and use controlled termination. The verified data does not provide noise, bandwidth, or temperature figures, so instrument designers should confirm them using the official datasheet.
推荐
Embedded Serial Communication
The MAX485CPA+ can bridge an embedded UART or controller to an RS-485/RS-422 physical layer in gateways, remote terminals, and embedded control products. Its 8-pin PDIP package is convenient for through-hole industrial boards, while the one-driver/one-receiver arrangement supports bidirectional communication with external direction control. The firmware and hardware must prevent simultaneous transmission from multiple nodes, and the PCB should use a controlled differential route. Because the provided data does not identify the supply voltage or maximum data rate, those values must be checked before selecting a replacement or bus speed.
推荐
Remote Sensor Networks
The MAX485CPA+ fits remote sensor networks that use a wired differential bus to connect distributed measurement nodes to a central controller. The differential interface is suited to environments where cable length and noise make single-ended communication less dependable, provided that termination, grounding, and protection are designed correctly. The transceiver's verified half-duplex operation supports shared-bus communication when node access is controlled. Verify common-mode voltage range, receiver thresholds, and environmental limits in the datasheet because those values are not included in the supplied web snippets.
推荐
推荐产品汇总
工程参考数据: MAX485CPA+ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MAX485EPA | MAX485ECPA | MAX481CPA | SP485CN-L |
|---|---|---|---|---|---|
| Product Type | Low-power RS-485/RS-422 transceiver | MAX485 family transceiver | MAX485 family transceiver | Related MAX family transceiver | RS-485/RS-422 transceiver candidate |
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | MaxLinear |
| Supported Interface | RS-485 / RS-422 | MAX485 family | MAX485 family | Related MAX family | RS-485/RS-422 candidate |
关键差异点
- Verified one-driver/one-receiver integration (对比 MAX481CPA)
- Same 8-pin PDIP replacement candidates (对比 SP485CN-L)
- Broad RS-485/RS-422 positioning (对比 MAX485EPA)
设计说明
Route the RS-485/RS-422 differential pair as a controlled impedance path between the transceiver and connector, keeping the pair short, closely coupled, and free of unnecessary stubs. Place the transceiver near the connector-side protection network when practical. Because the verified data does not provide exact layout dimensions or capacitor values, use the manufacturer datasheet and application guidance rather than inventing placement values.
Ensure that only one node drives the half-duplex bus at a time. Incorrect driver-enable timing, excessive termination, poor grounding, or long unshielded cables can produce reflections, false transitions, and unreliable communication. The MAX485CPA+ is not a substitute for surge protection or isolation; add those functions when the cable environment requires them.
Confirm supply voltage, quiescent current, driver loading, and receiver power requirements directly from the manufacturer datasheet. The supplied web data does not include those electrical values, so do not select a rail or decoupling network from assumption. Validate the complete board for ground-bounce margin and ensure the transceiver's enable states do not create unnecessary bus loading or contention.
Slew-rate limiting helps control transition energy, but signal integrity still depends on baud rate, cable length, topology, impedance, and termination. Establish an eye-quality or communication test at the intended network conditions. If the bus fails intermittently, check connector return paths, cable type, termination placement, grounding, and node-driving logic before changing the transceiver.
合规信息
The supplied verified web data does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for MAX485CPA+. Verify these claims using the manufacturer product documentation or a current distributor compliance record.