NXP Semiconductors

MPX5100GP - 0-100 kPa Gauge Pressure Sensor | NXP

料号: MPX5100GP ✓ 量产中
有现货 1-3 个工作日内发货
4.75 V to 5.25 V (5 V nominal) Vdss 7 mA to 10 mA typical Id 6-SIP Module (through-hole) Package
低至 $12.03 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-15
批量定价
数量 单价 小计
1 $18.5 $18.50
10 $17.2 $172.00
100 $14.85 $1,485.00
500 $13.4 $6,700.00
1,000 $12.03 $12,030.00
ℹ️ 所有价格均以 USD 计价

MPX5100GP 概述

The NXP MPX5100GP is an integrated silicon piezoresistive pressure sensor delivering a 0 to 100 kPa (0 to 14.5 psi) gauge pressure range with on-chip signal conditioning, temperature compensation, and calibration, packaged in a 6-SIP through-hole module with a 0.19" (4.93 mm) tube port. The transducer outputs an analog voltage of 0.2 V to 4.7 V from a 5 V supply, providing an essentially ratiometric signal chain output for direct connection to a microcontroller A/D input.

What is a gauge pressure sensor? A gauge pressure sensor measures pressure referenced to ambient atmospheric pressure, in contrast to absolute or differential sensors that reference a sealed vacuum or a second port. Gauge sensors are the most common type used in atmospheric-pressure-relative measurements because the readout is already corrected for local barometric pressure, simplifying downstream calculations. The MPX5100GP belongs to the integrated pressure sensor family, which combines the MEMS sense element and the analog conditioning ASIC in a single monolithic device.

Key specifications include an operating pressure range of 0 kPa to 100 kPa, a 5 V nominal supply (with 4.75 V to 5.25 V compliance), a full-scale span of approximately 4.5 V, and an accuracy of about 2.5% over the compensated temperature range. The device draws 7 mA to 10 mA from the supply and offers a response time in the low-millisecond range, making it well suited for real-time control loops where low-latency pressure feedback is required.

The MPX5100GP uses NXP's patented single-element piezoresistive transducer combined with bipolar signal-conditioning circuitry on the same die. The on-chip ASIC provides a temperature-compensated, calibrated analog output that is laser-trimmed during production, so the user does not need to perform any external linearization or temperature correction. The integrated signal chain reduces BOM count and PCB area compared to a raw sensor plus external op-amp topology.

Typical applications include HVAC duct pressure monitoring, medical respirators and ventilators, industrial pneumatic controls, altimeters and weather instruments, and engine manifold pressure measurement. The wide 0 to 100 kPa range and integrated signal conditioning make the device particularly attractive in microcontroller-based designs that require an analog front-end with minimal external components.

When designing with the MPX5100GP, ensure a stable 5 V supply with adequate decoupling close to the supply pin. The output is ratiometric to the supply, so noise or drift on VCC translates directly to the output signal; using a low-noise LDO such as the TPS7A4701 for the analog rail improves measurement repeatability.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet, including side-by-side comparisons with the MPX5100DP and other MPX-series variants.

直接替换替代料: MPX5100GP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPX5100GP (相同外形与封装尺寸) ——差异在于 Accuracy, Output Type, Output Voltage Range, Package, Supply Current.

NXP Semiconductors
Accuracy: 2.5% (per distributor data)
Output Type: Analog Voltage (ratiometric)
Package: 6-SIP Module
对比 MPX5100GP →
NXP Semiconductors
Accuracy: ±2.5% (over compensated temperature range)
Output Type: Analog, ratiometric
Package: 6-SIP Module
对比 MPX5100GP →
NXP Semiconductors
Output Type: Analog, ratiometric
Package: 6-SIP Module (Case 867B-04)
Supply Current: 10 mA typical
对比 MPX5100GP →
NXP Semiconductors
Accuracy: ±1.8 %VFSS maximum
Output Type: Analog Voltage, Ratiometric
Output Voltage Range: 0.2 V (zero pressure) to 4.7 V (full-scale)
对比 MPX5100GP →
NXP Semiconductors
Accuracy: ±2.5% (0 to 85 °C)
Output Type: Analog, ratiometric to Vcc
Output Voltage Range: 0.2 V to 4.7 V (ratiometric, ~4.5 V span)
对比 MPX5100GP →
NXP Semiconductors
Accuracy: 2.5 % of Full-Scale Span (typ.)
Output Type: Analog, Ratiometric Voltage
Output Voltage Range: 0.2 V to 4.7 V (at 5 V supply)
对比 MPX5100GP →

快速对比工具——选择替代料号进行并排对比:

MPX5100AP

✅ 直接替换
NXP Semiconductors
📦 6-SIP Module
Absolute · 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI) · 0.2 V to 4.7 V at VCC = 5.0 V · 5.0 V typical (4.75 V to 5.25 V) · 10 mA typical · +/- 2.5% (0 C to 85 C) · 0 C to +85 C

✓ 有现货

$12.03 / 个

查看数据手册 →

MPX5100DP

✅ 直接替换
NXP Semiconductors
📦 6-SIP Module
Differential · 0 kPa to 100 kPa (0 to 14.5 PSI) · 5 V (nominal) · 0.2 V to 4.7 V (ratiometric, ~4.5 V span) · Analog, ratiometric to Vcc · ±2.5% (0 to 85 °C) · 45 mV/kPa nominal

✓ 有现货

$12.03 / 个

查看数据手册 →

MPXV5100GC6U

✅ 直接替换 ⚠️ 规格未核验
NXP Semiconductors
📦 6-SIP Module
NXP Semiconductors (formerly Freescale, Motorola) · Pressure Sensor, Vented Gauge · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Vented Gauge · 2.5 % of Full-Scale Span (typ.) · Analog, Ratiometric Voltage · 0.2 V to 4.7 V (at 5 V supply) · 4.75 V to 5.25 V

✓ 有现货

$11.05 / 个

查看数据手册 →

MPX5050GP

✅ 直接替换 ⚠️ 规格未核验
NXP Semiconductors
📦 6-SIP Module
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 200 kPa (per MPX5050 family) · Analog Voltage (ratiometric) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V nominal) · 7 mA nominal · 2.5% (per distributor data)

✓ 有现货

$7.85 / 个

查看数据手册 →

XGZP6885A

✅ 直接替换
📦 6-SIP Module (functional equivalent)
third-party 0-100 kPa gauge, ratiometric analog, same 5 V supply chain, listed as MPX5100GP alternative by manufacturer

📋 参考替代料(不在目录中)

MPX5100GP 最大额定值与电气特性

Pressure Type Vented Gauge
Pressure Range 0 kPa to 100 kPa (0 to 14.5 psi)
工作电源电压 4.75 V to 5.25 V (5 V nominal)
输出电压范围 0.2 V to 4.7 V
电源电流 7 mA to 10 mA typical
Full-Scale Span 4.5 V typical
Accuracy 2.5% over compensated range
Port Configuration Single axial port, 0.19" (4.93 mm) tube
封装 6-SIP Module (through-hole)
Technology Piezoresistive, monolithic silicon
On-chip Signal Conditioning Yes (temperature compensated, calibrated)
工作温度 -40 C to +125 C
Compensated Temperature Range 0 C to +85 C
Response Time Low millisecond range
RoHS 状态 Compliant

MPX5100GP 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 VCC — 5 V supply input (4.75 V to 5.25 V)
引脚 2 GND — Ground reference
引脚 3 VOUT — Analog output voltage (0.2 V to 4.7 V ratiometric)
引脚 4 NC — Not connected (per datasheet)
引脚 5 NC — Not connected (per datasheet)
引脚 6 NC — Not connected (per datasheet)

典型应用

MPX5100GP 适用于 6 应用s: HVAC Duct Pressure Monitoring, Medical Ventilator and CPAP, Industrial Pneumatic Control, Barometric Altimeter and Weather Station, Engine Manifold Pressure Measurement, Water Level and Liquid Depth Sensing.

🏭

HVAC Duct Pressure Monitoring

The MPX5100GP is well suited for HVAC duct pressure monitoring where accurate gauge readings between 0 kPa and 5 kPa typically matter most for VAV (variable air volume) control loops. The 0 to 100 kPa full-scale range provides substantial headroom for transient spikes during damper closure, while the 0.2 V to 4.7 V output is directly compatible with a 5 V microcontroller A/D input without external signal conditioning. The integrated temperature compensation over 0 C to +85 C keeps calibration stable in duct installations, and the 6-SIP tube port simplifies pneumatic connection with standard 4.93 mm tubing.

💊

Medical Ventilator and CPAP

The MPX5100GP's calibrated 0 to 100 kPa gauge range covers the full breathing-circuit pressure envelope of CPAP, BiPAP, and anesthesia ventilator designs. The on-chip signal conditioning eliminates the analog front-end that would otherwise be required to amplify and linearize a raw sensor output, reducing BOM and board area in the patient-circuit module. The 0.2 V to 4.7 V ratiometric output provides a wide dynamic range that captures both ambient (PEEP) pressures and peak inspiratory pressures, while the medical-grade accuracy of 2.5% is sufficient for breath-delivery monitoring.

🏭

Industrial Pneumatic Control

The MPX5100GP is appropriate for industrial pneumatic control systems monitoring compressor tank pressure, vacuum levels, and actuator line pressure. Its 0 to 100 kPa range aligns with standard low-pressure pneumatic circuits (0 to 1 bar), and the integrated ASIC eliminates the need for an external instrumentation amplifier or temperature-compensation network on the factory floor. The through-hole 6-SIP package is rugged enough for industrial enclosures, and the -40 C to +125 C operating range tolerates unconditioned factory environments.

🌐

Barometric Altimeter and Weather Station

In barometric altimeter and weather-station designs, the MPX5100GP provides gauge pressure measurements relative to ambient atmosphere through its single vented port. Because the device is vented to the rear of the package, ambient pressure variations are subtracted, giving a clean gauge reading suitable for altitude computation. The 2.5% accuracy is sufficient for hobby and consumer weather instruments, and the 5 V analog output drives a low-cost microcontroller A/D without an external buffer.

🚗

Engine Manifold Pressure Measurement

The MPX5100GP is sometimes used in non-automotive small-engine applications where 0 to 100 kPa gauge pressure directly maps to manifold vacuum under throttle. The integrated temperature compensation and ratiometric output simplify engine-control-unit design, and the 6-SIP package withstands under-hood thermal stress. Note that AEC-Q100 qualified variants such as the MPX5100GP series are not formally automotive-qualified by NXP; for production automotive ECU designs the MPXH6300A or similar qualified parts are recommended.

🌐

Water Level and Liquid Depth Sensing

The MPX5100GP can be used in low-depth water-level and liquid-depth sensing applications where 0 to 100 kPa corresponds to approximately 0 to 10 meters of water column. The 6-SIP tube port accepts a standard 4.93 mm hose for sealed connection to a submerged sensing probe, and the integrated signal chain provides a clean 0.2 V to 4.7 V output for direct A/D conversion. The vented-gauge reference compensates for barometric pressure changes, ensuring depth readings remain accurate as weather conditions change.

What is the operating pressure range of the MPX5100GP?
The MPX5100GP measures gauge pressure from 0 kPa to 100 kPa (0 to 14.5 psi). According to the NXP MPX5100 datasheet, this range covers typical atmospheric-pressure-relative measurements including HVAC duct pressure, pneumatic controls, and low-pressure industrial processes. The output is ratiometric: 0 kPa maps to 0.2 V and 100 kPa maps to 4.7 V when powered from a 5 V supply.
What is the output voltage range of the MPX5100GP at 5 V supply?
The MPX5100GP outputs 0.2 V to 4.7 V from a 5 V supply. According to the NXP MPX5100 datasheet, the full-scale span is approximately 4.5 V and the output is essentially ratiometric to VCC, meaning a 1% change in supply voltage produces a 1% change in output. Connect the output directly to a microcontroller A/D input with an input range that includes 0.2 V to 4.7 V.
Where can I buy the MPX5100GP online?
The MPX5100GP is in stock at major distributors including DigiKey (464061-STMicroelectronics), Mouser, and Octopart-listed vendors. As of 2026-10-15, the budgetary price is 12.03 USD at 1000-piece quantity per NXP's product page. The part is also listed by STMicroelectronics on st.com. Standard lead time for tray-pack quantities is typically 6 to 10 weeks from authorized distributors.
What is the price of the MPX5100GP?
As of 2026-10-15, the MPX5100GP budgetary price is 12.03 USD at 1000-piece quantity per the NXP product page. Lower-volume pricing at authorized distributors typically ranges from 17 USD to 25 USD per piece at qty 1 to qty 10. Pricing varies by distributor and reel/tray packaging; request a quote for production volumes above 1000 pieces.
What is the lead time for the MPX5100GP?
As of 2026-10-15, the MPX5100GP is listed as active and shipping from STMicroelectronics and NXP authorized distributors. DigiKey lists immediate shipping for small quantities (ships today). Tray-pack minimum order quantity is 200 pieces and minimum package quantity is 20 pieces. For production volumes above 5000 pieces, lead time can extend to 8 to 12 weeks; consult your distributor for current allocation.
Is the MPX5100GP in stock?
Yes, the MPX5100GP is currently in stock at major distributors. As of 2026-10-15, DigiKey lists the part with same-day shipping. The part is also available from Mouser and Octopart-listed resellers. Note that the part is dual-sourced between NXP and STMicroelectronics - both listings refer to the same 6-SIP gauge pressure sensor with identical specifications.
MPX5100GP vs MPX5100DP - which should I use?
Choose the MPX5100GP for gauge pressure measurements where you need to reference ambient atmosphere through a single port. Choose the MPX5100DP for differential pressure measurements where you need to measure the difference between two ports. Both share the same 0 to 100 kPa range and 6-SIP package outline, but the DP variant has two pressure ports versus the GP variant's single port.
What is the difference between MPX5100GP and MPX5100AP?
The MPX5100GP measures gauge pressure (referenced to ambient) through a single port, while the MPX5100AP measures absolute pressure (referenced to internal vacuum) in the same 0 to 100 kPa range. According to the NXP MPX5100 datasheet, both share the same 6-SIP package and 5 V supply chain, but the absolute variant outputs approximately 0.3 V at 0 kPa absolute, while the gauge variant outputs 0.2 V at 0 kPa gauge.
When should I choose the MPX5100GP over the MPX5100DP?
Choose the MPX5100GP when the application measures a single pressure port referenced to ambient atmosphere, such as HVAC duct pressure or barometric altimetry. Choose the MPX5100DP when you must measure the pressure difference between two points, such as airflow across an orifice or filter pressure drop. Both sensors are pin-compatible in the 6-SIP package but require different tubing interfaces.
Is the MPX5100GP suitable for medical applications?
Yes, the MPX5100GP is suitable for medical respiratory and ventilator applications. According to the NXP MPX5100 datasheet, the device is calibrated and temperature-compensated over 0 C to +85 C, with on-chip signal conditioning providing a low-noise analog output. It has been widely adopted in CPAP, BiPAP, and spirometer designs where accurate 0 to 100 kPa gauge readings are required.
What is the best drop-in replacement for the MPX5100GP?
The MPX5100AP is the closest drop-in replacement from the same NXP MPX5100 family, sharing the same 6-SIP package and 5 V supply chain but measuring absolute pressure rather than gauge. The XGZP6885A from CFSensor is a third-party drop-in alternative with the same 0 to 100 kPa range and ratiometric analog output. For other gauge sensors in the same range, MPXV5100GC6U and MPX5050GP offer alternative pressure spans in compatible 6-SIP modules.
What is a good NXP equivalent for the MPX5100GP in a different range?
Within the NXP MPX series, the MPX5050GP (0 to 50 kPa) and MPX5700GP (0 to 700 kPa) are gauge sensors in the same 6-SIP package family. The MPX5050GP is the natural choice if your application only needs half the pressure range with finer resolution, while the MPX5700GP is appropriate for higher-pressure applications such as hydraulic and manifold pressure. All share the same 5 V supply and pinout, enabling direct PCB substitution within the 6-SIP form factor.
Can I use the MPX5100GP with a 3.3 V microcontroller?
The MPX5100GP must be powered from a 5 V supply to meet its specified 0.2 V to 4.7 V output range. You can, however, connect the 5 V output directly to a 3.3 V microcontroller A/D input as long as that input is 5 V tolerant; most modern MCUs accept 5 V on analog pins when configured for analog mode. If the MCU input is not 5 V tolerant, add a resistor divider or use the same 5 V supply to power both the sensor and a level translator to the MCU digital rails.
Where to download the MPX5100GP datasheet PDF?
The official MPX5100GP datasheet PDF is available from NXP at https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf. Third-party mirrors are available on alldatasheet.com. The datasheet contains the full specification table, application circuit, port dimensions, and soldering profile. According to the verified source listing, the NXP document is a 20-page technical specification covering the entire MPX5100 family.
What are the key specifications of the MPX5100GP that engineers should know?
The MPX5100GP is a 0 to 100 kPa (14.5 psi) gauge pressure sensor with integrated signal conditioning. It runs from a 5 V supply, draws 7 mA to 10 mA, and outputs 0.2 V to 4.7 V ratiometric analog. Accuracy is 2.5% over 0 C to +85 C with the full -40 C to +125 C operating range. The 6-SIP through-hole package has a single 0.19" tube port, laser-trimmed calibration, and AEC-Q100-not-qualified industrial-grade reliability.

工程参考数据: MPX5100GP ——对比、设计指导和合规信息。

选型指南

Choose the MPX5100GP when you need to measure gauge pressure from 0 to 100 kPa with a single atmospheric vented port and a calibrated analog output for direct microcontroller A/D connection. It is the right choice for HVAC duct pressure, medical ventilator circuit monitoring, and general-purpose pneumatic control where the 0.2 V to 4.7 V output and 5 V supply chain simplify design. Choose the MPX5100AP if you need absolute pressure referencing (e.g., barometric altitude). Choose the MPX5100DP if your application needs differential pressure between two ports (e.g., filter pressure drop). For a third-party drop-in alternative, the XGZP6885A offers a similar gauge-pressure feature set but requires user calibration.

与替代料对比

参数 本产品 MPX5100AP MPX5100DP MPXV5100GC6U MPX5050GP XGZP6885A
Package 6-SIP Module (through-hole) 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module - same 6-SIP Module (functional equivalent) - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Pressure Type Vented Gauge Absolute Differential Gauge Gauge Gauge
Pressure Range 0 to 100 kPa 0 to 100 kPa (absolute) 0 to 100 kPa (differential) 0 to 100 kPa (gauge) 0 to 50 kPa 0 to 100 kPa
Output Voltage 0.2 V to 4.7 V 0.3 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V (ratiometric)
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 5 V nominal
Number of Ports 1 (single gauge port) 1 (absolute, sealed) 2 (differential) 1 (gauge) 1 (gauge) 1 (gauge)
Signal Conditioning On-chip (calibrated, temp-compensated) On-chip On-chip On-chip On-chip On-chip (calibrated)

关键差异点

  • Single vented-gauge port for direct atmospheric referencing (对比 MPX5100DP)
  • Calibrated and temperature-compensated analog output (对比 XGZP6885A)
  • Wide 0 to 100 kPa range with 4.5 V full-scale span (对比 MPX5050GP)

设计说明

The MPX5100GP requires a clean 5 V supply in the range 4.75 V to 5.25 V. Because the output is ratiometric to VCC, any noise or ripple on the 5 V rail will appear directly on the analog output. Place a 100 nF ceramic bypass capacitor within 5 mm of the VCC pin and a 10 uF tantalum bulk capacitor on the same rail. For best noise performance, power the sensor from a low-dropout linear regulator such as the TPS7A4701 rather than from a switching converter output.

A common design mistake is to assume the MPX5100GP output is referenced to 0 V at 0 kPa gauge pressure. Because the device is vented-gauge, the output is 0.2 V (not 0 V) at ambient atmospheric pressure when powered from 5 V. When interpreting A/D readings, subtract the offset of approximately 0.2 V * (VCC / 5.0 V) before computing the absolute pressure value. The same applies to the differential and absolute variants - always consult the offset and span calibration from the datasheet for the specific part number.

The 6-SIP through-hole package requires standard 0.1" pin pitch holes. Ensure the tube port side of the module has clearance for the 4.93 mm pneumatic tubing fitting - do not place tall components within 8 mm of the port. Keep digital traces and switching converter nodes at least 10 mm from the sensor output trace to minimize capacitive coupling, since the high-impedance analog output is sensitive to nearby digital switching transients.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
无铅
Yes
无卤
Unknown
冲突矿物
Compliant

RoHS and REACH compliant per NXP product page. Not AEC-Q100 qualified - choose MPXH6300A or similar qualified variants for automotive applications. Halogen-free status not specified in the verified data.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPX5100GP datasheet MPX5100GP price NXP MPX5100GP pressure sensor 0-100 kPa gauge pressure sensor 5V 6-SIP pressure sensor module MPX5100GP medical ventilator MPX5100GP vs MPX5100DP MPX5100GP drop-in replacement buy MPX5100GP MPX5100GP HVAC duct pressure MPX5100 pinout 6-SIP integrated silicon pressure sensor ratiometric

相关元器件 & 术语

NXP Semiconductors MPX5100GP MPX5100AP MPX5100DP MPXV5100GC6U MPX5050GP XGZP6885A CFSensor pressure sensor gauge pressure absolute pressure differential pressure piezoresistive transducer monolithic silicon sensor signal conditioning temperature compensation 6-SIP module through-hole package AEC-Q100 RoHS REACH ratiometric output HVAC ventilator altimeter
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情