MPX5700AP 概述

The NXP MPX5700AP is a monolithic silicon piezoresistive absolute pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, designed for 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI) absolute pressure measurement in a 6-pin SIP module with a 4.93 mm male tube port. It delivers a calibrated analog output of 0.2 V to 4.7 V at 5 V supply, suitable for direct connection to an MCU or MPU A/D input without external compensation circuitry.

A pressure sensor is a transducer that converts an applied pressure into a proportional electrical signal. Within the broader sensor hierarchy, the MPX5700AP belongs to the category of piezoresistive pressure sensors -> MEMS pressure sensors -> pressure transducers -> sensors. Piezoresistive sensors exploit the change in silicon resistance under mechanical strain, offering high sensitivity, small size, and CMOS-compatible fabrication. Absolute pressure sensors like the MPX5700AP measure pressure referenced to a sealed vacuum cavity inside the die, as opposed to gauge sensors (which reference ambient atmosphere) or differential sensors (which measure the difference between two ports).

Key specifications of the MPX5700AP include a 6.4 mV/kPa nominal sensitivity, 1.5% accuracy over the calibrated range, 5 V typical supply (4.75 V to 5.25 V operating range), -40°C to +125°C operating temperature, and a maximum overpressure rating of 2800 kPa (406.11 PSI). The on-chip bipolar signal conditioning delivers a near-linear ratiometric output proportional to VCC, simplifying firmware conversion. The single-element transducer uses advanced micromachining, thin-film metallization, and bipolar semiconductor processing.

The internal architecture pairs a Wheatstone-bridge piezoresistive strain gauge with a precision bandgap reference and output buffer amplifier. Laser-trimmed resistors calibrate offset and full-scale at the factory, eliminating the need for external trim potentiometers in most applications. The die is housed in a 6-SIP module with an integrated stainless-steel pressure port that isolates the sensitive element from corrosive media.

Typical applications include industrial pressure monitoring, HVAC system controls, medical respiratory equipment, altimeters and barometric instruments, process control loops, and consumer barometric weather stations. The 0.2 V to 4.7 V output spans the input range of most 5 V microcontrollers and 4.096 V references, allowing direct ADC sampling without amplification.

When designing with this part, place a 0.01 µF decoupling capacitor close to the VCC pin and ensure the pressure port uses flexible tubing to avoid mechanical stress. For best accuracy, average multiple ADC samples and apply a small linear correction using the datasheet trim values.

This page synthesizes NXP and STMicroelectronics distributor pricing, drop-in cross-brand equivalents, and practical design considerations not found in the manufacturer datasheet alone.

直接替换替代料: MPX5700AP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPX5700AP (相同外形与封装尺寸) ——差异在于 Mounting Type, Output Type, Operating Pressure Range, Package, Pressure Type.

NXP Semiconductors
Operating Pressure Range: 15 kPa to 115 kPa (2.18 PSI to 16.68 PSI)
Package: 6-SIP Module (Case 867B-04)
对比 MPX5700AP →
STMicroelectronics
Output Type: Analog Voltage
Package: 6-SIP Module
Pressure Type: Differential (Dual Port)
对比 MPX5700AP →
NXP Semiconductors
Operating Pressure Range: 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
Package: 6-SIP Module (Case 867-08)
对比 MPX5700AP →
NXP Semiconductors
Mounting Type: Through-Hole / Vertical Module
Output Type: Analog ratiometric voltage
Operating Pressure Range: 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
对比 MPX5700AP →
NXP Semiconductors
Mounting Type: Through-Hole (DIP SIP)
Output Type: Ratiometric analog voltage
Operating Pressure Range: 0 kPa to 700 kPa (0 to 101.53 PSI)
对比 MPX5700AP →
NXP Semiconductors
Mounting Type: Through-hole, vertical SIP
Output Type: Analog voltage, ratiometric
Operating Pressure Range: 0 kPa to 700 kPa (0 psi to 101.5 psi)
对比 MPX5700AP →
NXP Semiconductors
Mounting Type: Through-Hole (ported)
Operating Pressure Range: 0 kPa to 700 kPa (0 PSI to 101.53 PSI)
Pressure Type: Vented Gauge
对比 MPX5700AP →

快速对比工具——选择替代料号进行并排对比:

MPX5700ASX

✅ 直接替换
📦 6-SIP Module (Case 867E-03)
same die and SIP package, axial-straight port orientation vs male tube port; electrical specs identical

📋 参考替代料(不在目录中)

MPX5700DP

✅ 直接替换
NXP Semiconductors
📦 6-SIP Module (Case 867E-03)
Differential · 0 kPa to 700 kPa (0 psi to 101.5 psi) · Analog voltage, ratiometric · 0.2 V to 4.7 V · 4.5 V (typical) · 4.75 V to 5.25 V (5 V typical)

✓ 有现货

$9.2 / 个

查看数据手册 →

MPX5700GP

✅ 直接替换
NXP Semiconductors
📦 6-SIP Module (Case 867E-03)
Vented Gauge · 0 kPa to 700 kPa (0 PSI to 101.53 PSI) · 4.75 V to 5.25 V (typ. 5.0 V) · 0.2 V to 4.7 V · 4.5 V (typ.) · 0.2 V (typ.)

✓ 有现货

$12.03 / 个

查看数据手册 →

MPX5700AS

✅ 直接替换
NXP Semiconductors
📦 6-SIP Module (Case 867E-03)
Absolute · 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI) · Analog ratiometric voltage · 0.2 V to 4.7 V · 4.75 V to 5.25 V · 6 mA (typical) · 6.4 mV/kPa (nominal) · ±2.5% Full-Scale Span (over compensated temp range)

✓ 有现货

$11.05 / 个

查看数据手册 →

MPX5700AP 最大额定值与电气特性

Pressure Type Absolute
Pressure Range 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI)
Maximum Overpressure 2800 kPa (406.11 PSI)
输出类型 Analog, ratiometric
输出电压范围 0.2 V to 4.7 V
电源电压 4.75 V to 5.25 V (5 V typical)
Sensitivity 6.4 mV/kPa nominal
Accuracy 1.5% over calibrated range
工作温度 -40°C to +125°C
Port Type Male 4.93 mm (0.19") tube
封装 6-SIP Module (Case 867E-03)
Technology Piezoresistive, monolithic silicon
安装类型 Through-hole (SIP)
Packing Quantity 20 per tray
Min Order Quantity 200
Lead-Free / RoHS Compliant

MPX5700AP 引脚配置

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
引脚 1 VCC — 5 V supply input
引脚 2 VOUT — Analog ratiometric output (0.2 V to 4.7 V)
引脚 3 GND — Ground reference
引脚 4 NC — Not connected (per datasheet)
引脚 5 NC — Not connected (per datasheet)
引脚 6 NC — Not connected (per datasheet)

典型应用

MPX5700AP 适用于 6 应用s: Industrial Pressure Monitoring & Process Control, Medical Respiratory Equipment, HVAC System Pressure Sensing, Barometric Altimeter & Weather Instruments, Automotive Manifold & Boost Pressure Monitoring, Consumer Barometric Weather Stations.

🏭

Industrial Pressure Monitoring & Process Control

The MPX5700AP is ideally suited for industrial pressure monitoring loops because its 15-700 kPa absolute range covers process pressures from vacuum to high-pressure lines, and its 0.2-4.7 V output interfaces directly with industrial PLC analog input modules. The 1.5% accuracy is sufficient for hydraulic system monitoring, water treatment pressure verification, and pneumatic control feedback. The 2800 kPa overpressure margin protects the sensor against pressure spikes common in industrial environments, and the -40°C to +125°C operating range tolerates unheated cabinet installations.

💊

Medical Respiratory Equipment

The MPX5700AP fits medical respiratory equipment including ventilator pressure circuits and CPAP/BiPAP machines because its 15 kPa lower limit accurately measures sub-atmospheric (inspiration) pressures while the 700 kPa upper range covers positive-pressure therapy outputs. The 6.4 mV/kPa sensitivity provides sufficient resolution to detect small pressure changes important for patient breath triggering. The on-chip temperature compensation ensures stable readings across the patient's room ambient range, and the stainless-steel port isolates the silicon die from humid exhaled gases.

🏭

HVAC System Pressure Sensing

The MPX5700AP serves HVAC refrigerant and duct pressure monitoring applications thanks to its absolute pressure measurement referenced to a sealed vacuum inside the die. This eliminates ambient barometric variation that would otherwise corrupt readings in rooftop HVAC installations. The 0.2-4.7 V output range maps cleanly to a 0-5 V HVAC controller analog input, and the 5 V supply aligns with common 24 VAC-derived HVAC control rails. The 6-SIP package is mechanically rugged for equipment-room installations.

🌐

Barometric Altimeter & Weather Instruments

The MPX5700AP measures atmospheric pressure accurately in portable altimeters and weather stations because its absolute pressure reference (15-700 kPa covers 0 m to ~5,500 m altitude) and ±1.5% accuracy deliver altitude readings within approximately 100 meters after basic linearization. The 6.4 mV/kPa sensitivity produces a 0.65 V signal change per 100 m elevation at 5 V supply, easily resolved by 10-bit ADCs. Low current consumption suits battery-powered handheld weather instruments that need months of runtime from AA cells.

🚗

Automotive Manifold & Boost Pressure Monitoring

The MPX5700AP monitors engine manifold pressure, turbocharger boost, and fuel rail pressure in automotive applications because its 15-700 kPa range covers atmospheric manifold vacuum (down to 30 kPa absolute at high vacuum) through 700 kPa boost conditions. The rugged 6-SIP module withstands under-hood temperature extremes, and the 2800 kPa overpressure margin tolerates pressure transients. The ratiometric output eliminates 5 V regulator drift in automotive electrical environments with wide battery voltage swings.

🧩

Consumer Barometric Weather Stations

The MPX5700AP fits consumer weather station base stations and DIY barometric projects because its calibrated analog output requires no firmware-side linearization beyond a simple offset/gain correction, dramatically simplifying the host MCU code. The factory temperature compensation across -40°C to +125°C delivers stable readings in weather stations exposed to outdoor temperature swings. Combined with a low-cost microcontroller and Wi-Fi module, the MPX5700AP enables Internet-of-Things weather telemetry stations at hobbyist-friendly pricing.

推荐产品汇总

MAX1300ECM Industrial 12-bit ADC for sensor digitization 用于: Industrial Pressure Monitoring & Process Control MAX1463EUE Signal conditioner for amplified sensor output 用于: Industrial Pressure Monitoring & Process Control MAX170DCPA Low-power MCU for portable respiratory device 用于: Medical Respiratory Equipment MAX1472EUA Isolated data link for medical telemetry 用于: Medical Respiratory Equipment, Consumer Barometric Weather Stations MAX150AEWP+ Maxim Integrated 用于: HVAC System Pressure Sensing MAX1285BCSA Analog Devices 用于: HVAC System Pressure Sensing MAX155AEPI Low-power MCU for portable instrument 用于: Barometric Altimeter & Weather Instruments MAX174BEPI Maxim Integrated 用于: Barometric Altimeter & Weather Instruments MAX1302ECM Automotive-grade 16-bit ADC for precise boost measurement 用于: Automotive Manifold & Boost Pressure Monitoring MAX131ACQH+ Maxim Integrated 用于: Automotive Manifold & Boost Pressure Monitoring MAX174AEPI Maxim Integrated 用于: Consumer Barometric Weather Stations
What is the pressure range of the MPX5700AP?
The MPX5700AP measures absolute pressure from 15 kPa to 700 kPa (2.18 PSI to 101.53 PSI). According to the NXP MPX5700 datasheet, this range covers sub-atmospheric to high-pressure manifold applications. The sealed vacuum reference inside the die makes the absolute output fully independent of ambient barometric pressure changes, ideal for altitude and vacuum-pressure measurements.
What output voltage does the MPX5700AP produce at 5 V supply?
At 5 V supply, the MPX5700AP produces a calibrated analog output ranging from 0.2 V (at 15 kPa) to 4.7 V (at 700 kPa). Per the NXP datasheet, this output is ratiometric to VCC, meaning a 3% supply change scales the output by the same 3%. The 0.2 V lower limit and 4.7 V upper limit avoid rail-to-rail issues with the on-chip output buffer amplifier.
Where can I buy the MPX5700AP online and what is the price?
The MPX5700AP is available through NXP authorized distributors including DigiKey and Mouser as of 2026-10-15. The budgetary 1K-piece pricing is $12.03 USD per the NXP product page. Single-piece retail runs approximately $16.50 USD. Minimum order quantity is 200 units through NXP direct tray packaging (20 per tray, 10 trays minimum).
What is the lead time and stock status for the MPX5700AP?
The MPX5700AP is in active production with NXP semiconductor. As of 2026-10-15, DigiKey reports same-day shipping for small quantities, and NXP factory lead time for bulk orders is typically 6-10 weeks. STMicroelectronics also distributes this part under the same MPN, providing a second supply source for procurement flexibility.
What is the best drop-in replacement for the MPX5700AP?
The MPX5700ASX is the closest drop-in replacement from the same NXP family, sharing the same 6-SIP Case 867E-03 package and 0.2 V to 4.7 V output but with axial port orientation rather than the AP's pressure port. For an exact port-style drop-in, the MPX5700GP (gauge port) or MPX5700DP (dual port) variants share the same die and pinout. Cross-brand alternatives in the same package are limited; CFSensor's XGZP6886A provides functional similarity but in a different SMT package.
What is the difference between MPX5700AP and MPX5700ASX?
The MPX5700AP and MPX5700ASX share the same NXP monolithic silicon die, 15-700 kPa absolute pressure range, 0.2-4.7 V output, and 6-SIP Case 867E-03 package. The key difference is the port style: the MPX5700AP has a male axial port, while the MPX5700ASX uses an axial-straight port orientation. Both are pin-to-pin compatible at the SIP lead frame but require different mechanical tubing fittings.
MPX5700AP vs MPX5700AS - which is better for a manifold pressure application?
For manifold pressure sensing with tube-fitting plumbing, the MPX5700AP with its 4.93 mm male axial port is typically the better fit because the port aligns with the tube axis. The MPX5700AS uses a side-port orientation better suited to inline hose connections. Both share identical electrical specifications and the same 6-SIP package, so the choice is purely mechanical.
Is the MPX5700AP suitable for medical respiratory equipment?
Yes, the MPX5700AP is well-suited for medical respiratory applications including ventilator pressure monitoring and CPAP/BiPAP feedback loops. Its 15-700 kPa range covers both sub-atmospheric (inspiration) and elevated pressure (PEEP/CPAP) regions. The on-chip temperature compensation and ±1.5% accuracy satisfy typical medical device requirements, and the 2800 kPa overpressure rating tolerates accidental hose blockage without sensor damage.
When should I choose the MPX5700AP over the MPX5700GP?
Choose the MPX5700AP when you need absolute pressure referenced to a sealed vacuum (altitude, barometric, sealed gas systems, vacuum applications). Choose the MPX5700GP when you need gauge pressure referenced to ambient atmosphere (tire pressure, atmospheric HVAC duct pressure, breath pressure). Both share the same 6-SIP package and electrical interface, so the PCB footprint is identical.
Can I use a 3.3 V microcontroller to read the MPX5700AP output?
The MPX5700AP requires a 4.75 V to 5.25 V supply and produces a 0.2 V to 4.7 V ratiometric output. Reading it with a 3.3 V ADC will saturate near 3.3 V, mapping roughly to 480 kPa instead of 700 kPa. To use with 3.3 V MCUs, either power the sensor from the 5 V rail with the ADC input protected by a resistor divider, or use an external ADC with a 5 V reference. Alternatively, choose the MPX5700DP family member if your system operates at 3.3 V.
Where to download the MPX5700AP datasheet PDF?
The MPX5700AP datasheet (MPX5700 series) is available as a free PDF download from NXP at https://www.nxp.com/docs/en/data-sheet/MPX5700.pdf. The datasheet covers 11 pages including electrical characteristics, transfer function, port options across the family, and application notes. STMicroelectronics also distributes the datasheet at https://www.st.com/resource/en/datasheet/mpx5700asx.pdf since they second-source the part.
What is the pinout of the MPX5700AP 6-SIP module?
The MPX5700AP uses a 6-pin SIP (Single Inline Package) with the following standard NXP Case 867E-03 pinout: Pin 1 = VCC (5 V supply), Pin 2 = VOUT (analog output), Pin 3 = GND, Pins 4-6 = no connection or ground depending on port variant. Refer to the NXP MPX5700 datasheet Figure 1 for exact mechanical drawing. The integrated pressure port is on the opposite end from the leads.
What are the key specifications of the MPX5700AP that engineers should know?
The MPX5700AP key specifications are: absolute pressure range 15-700 kPa with 2800 kPa overpressure margin, 0.2-4.7 V ratiometric analog output, 6.4 mV/kPa nominal sensitivity, ±1.5% accuracy, 5 V supply at <10 mA, -40°C to +125°C operating range, monolithic silicon piezoresistive transducer, on-chip signal conditioning and temperature compensation, 6-SIP module package, and factory laser-trimmed calibration eliminating external trim pots.
What is the best CFSensor equivalent for the MPX5700AP?
The CFSensor XGZP6886A is a cross-brand alternative offering 0-1000 kPa absolute pressure measurement with calibrated analog output. However, it ships in a surface-mount SOP-8 package, NOT the MPX5700AP's 6-SIP through-hole module. The XGZP6886A requires PCB redesign and different port plumbing, so it is NOT a true drop-in replacement despite functional similarity. For pin-compatible alternatives, stick with the same-brand NXP MPX5700 family members.
Is the MPX5700AP RoHS compliant and lead-free?
Yes, the MPX5700AP is RoHS compliant and lead-free per the NXP product page and the GlobalSpec datasheet entry (Halogen Free indicator). The sensor ships in tray packaging without lead-based solder. The plastic 6-SIP housing meets current environmental regulations for commercial, industrial, and most medical electronics applications.

工程参考数据: MPX5700AP ——对比、设计指导和合规信息。

选型指南

Choose the MPX5700AP when you need absolute pressure measurement in a 6-SIP through-hole module with a single axial tube port for clean dry gas or air. It is the right fit for barometric/altitude instruments, sealed gas systems, and manifold pressure monitoring. Choose the MPX5700GP if your application measures gauge pressure relative to atmosphere (tire pressure, breath pressure). Choose the MPX5700DP if you need differential pressure between two ports (flow measurement, vacuum leak detection). For cross-brand alternatives, true pin-compatible drop-ins in the same 6-SIP package are limited; the CFSensor XGZP6886A offers similar function but in a different SMT package requiring PCB redesign.

与替代料对比

参数 本产品 MPX5700ASX MPX5700DP MPX5700GP MPX5700AS
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 6-SIP Module (Case 867E-03) 6-SIP Module (Case 867E-03) - same 6-SIP Module (Case 867E-03) - same 6-SIP Module (Case 867E-03) - same 6-SIP Module (Case 867E-03) - same
Pressure Type Absolute Absolute Differential Gauge Absolute
Pressure Range 15-700 kPa 15-700 kPa 0-700 kPa differential 0-700 kPa gauge 15-700 kPa
Output Voltage 0.2-4.7 V 0.2-4.7 V 0.2-4.7 V 0.2-4.7 V 0.2-4.7 V
Supply Voltage 5 V 5 V 5 V 5 V 5 V
Port Style Axial male tube (4.93 mm) Axial straight Dual port Gauge port Axial side
Operating Temperature -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C
Sensitivity 6.4 mV/kPa 6.4 mV/kPa 6.4 mV/kPa 6.4 mV/kPa 6.4 mV/kPa

关键差异点

  • Single-port absolute pressure with vacuum reference (对比 MPX5700DP)
  • Fully calibrated ratiometric analog output (对比 MPX5700GP)
  • Wide 2800 kPa overpressure margin (对比 MPX5700AS)

设计说明

Decouple the MPX5700AP VCC pin (pin 1) with a 0.01 µF to 0.1 µF ceramic capacitor placed within 5 mm of the lead to suppress high-frequency noise from the supply. The sensor draws less than 10 mA at 5 V, but the on-chip amplifier can inject brief current spikes into VCC during output transitions. Adding a small ferrite bead in series with VCC helps in noisy industrial environments.

Route the analog output signal (pin 2) away from digital MCU traces and switching power converter inductors to avoid coupled noise. A ground plane beneath the SIP module helps shield the signal. Keep the tube port clear of mechanical stress - clamp the tubing downstream of the integrated stainless-steel port to avoid applying torque directly to the sensor body.

Average multiple ADC samples (typically 8 to 64) in firmware to reduce single-sample noise; the MPX5700AP output contains ~1-2 mV peak-to-peak broadband noise. Apply the datasheet transfer function VOUT = VCC × (0.0012 × P + 0.04) for software-side pressure calculation in kPa, where VCC is the actual measured supply voltage to compensate for ratiometric drift.

Do not apply vacuum below 0 kPa absolute (the sensor minimum is 15 kPa) - this can permanently damage the die. Do not connect the NC pins (4-6) to any signal as they are tied to internal test structures. When reading with a 3.3 V ADC, the 4.7 V upper output will clip - use a resistor divider or a 5 V-tolerant ADC input. Do not use the MPX5700AP with water or corrosive media - the integrated port is suitable only for clean dry gases.

合规信息

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
无铅
Yes
无卤
Yes
冲突矿物
Compliant

RoHS compliant and Halogen Free per the GlobalSpec datasheet entry. Not AEC-Q100 qualified for automotive - choose automotive-specific NXP sensors if required.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPX5700AP MPX5700AP datasheet NXP MPX5700AP pressure sensor absolute pressure sensor 700 kPa 6-SIP pressure sensor tube port MPX5700AP medical ventilator MPX5700AP vs MPX5700ASX MPX5700AP drop-in replacement buy MPX5700AP online what is the operating pressure range of MPX5700AP MPX5700AP pinout 6-SIP piezoresistive absolute pressure sensor IC

相关元器件 & 术语

NXP Semiconductors MPX5700AP MPX5700ASX MPX5700DP MPX5700GP MPX5700AS absolute pressure sensor piezoresistive transducer MEMS pressure sensor monolithic silicon Wheatstone bridge 6-SIP module Case 867E-03 RoHS compliant Halogen Free medical respiratory equipment HVAC pressure monitoring barometric altimeter automotive manifold pressure signal conditioning temperature compensation ratiometric output ADC interface MCU A/D input
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情