NXP Semiconductors

MPXV7025GP - ±25kPa Compound Pressure Sensor, 8-SMD | NXP Semiconductors

料号: MPXV7025GP ✓ 量产中
有现货 1-3 个工作日内发货
0.2 V to 4.7 V Vdss 8-SMD, Gull Wing, Side Port Package
低至 $7.5 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-15
批量定价
数量 单价 小计
1 $11.5 $11.50
10 $10.35 $103.50
100 $9.2 $920.00
500 $8.3 $4,150.00
1,000 $7.5 $7,500.00
ℹ️ 所有价格均以 USD 计价

MPXV7025GP 概述

The NXP Semiconductors MPXV7025GP is an integrated silicon piezoresistive pressure transducer with on-chip signal conditioning, temperature compensation, and calibration, measuring ±3.63 PSI (±25 kPa) compound pressure. Housed in an 8-SMD gull-wing package with a side-mounted 0.13" (3.18 mm) tube port, it delivers an analog output of 0.2 V to 4.7 V proportional to applied pressure for direct microcontroller ADC interfacing.

A pressure sensor is a transducer that converts an applied pressure into a proportional electrical signal, typically voltage. The MPXV7025GP belongs to the integrated silicon pressure sensor family (piezoresistive transducer -> MEMS pressure sensor -> pressure sensor -> sensor IC), combining a micromachined silicon diaphragm with on-board ASIC conditioning. This integration eliminates the need for external amplification or temperature compensation circuitry, simplifying design-in for engineers.

Key features include a compound pressure range allowing both positive and vacuum measurement, a ratiometric analog output suitable for 5V supply systems, and factory calibration that removes user-side trimming. The device operates over a wide supply voltage with low power consumption and provides temperature-compensated output across its specified operating range. Its integrated signal chain produces a clean analog voltage that maps linearly to applied pressure, reducing software overhead.

The MPXV7025GP is built using NXP's proprietary MEMS piezoresistive technology combined with a bipolar op-amp signal-conditioning ASIC. The Wheatstone bridge formed by implanted resistors on the silicon diaphragm produces a differential millivolt signal that is amplified, offset-corrected, and temperature-compensated to deliver a ground-referenced 0.2 V to 4.7 V swing. This single-chip integration dramatically improves noise immunity compared to discrete transducer designs.

Typical applications include HVAC air-flow monitoring, respiratory equipment, barometric compensation for altimeters, process control systems, and medical vacuum/pressure monitoring. The compound range enables measurement in systems that see both pressure and vacuum.

When designing with this part, decouple the VCC pin with a 100 nF ceramic capacitor placed close to the sensor leads. The output is ratiometric to VCC, so for highest accuracy, ADC read the regulator should share the same supply rail as the sensor or use a precision reference.

This page synthesizes distributor pricing, drop-in same-brand alternatives (MPXV7025DP, MPXV7002 series), and practical design notes not found in the manufacturer datasheet.

直接替换替代料: MPXV7025GP ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MPXV7025GP (相同外形与封装尺寸) ——差异在于 Port Style, Supply Voltage, Operating Temperature, Output Type, Pressure Type.

NXP Semiconductors
Port Style: Dual Ports, Same Side
Pressure Type: Differential
对比 MPXV7025GP →
NXP Semiconductors
Port Style: Male, 0.13 in (3.3 mm) tube, Dual, Same Side
Supply Voltage: 5 V nominal (4.75 V to 5.25 V)
Operating Temperature: -40 C to +125 C
对比 MPXV7025GP →
NXP Semiconductors
Port Style: Dual horizontal ports, same side (DP)
Supply Voltage: 5 V typical (4.75 V to 5.25 V)
Operating Temperature: 0C to +85C
对比 MPXV7025GP →
NXP Semiconductors
Supply Voltage: 5.0 V (typical)
Operating Temperature: -40 °C to +125 °C
Output Type: Analog, ratiometric
对比 MPXV7025GP →
NXP Semiconductors
Port Style: Dual ports, same side, male 0.13" (3.3 mm) tube
Supply Voltage: 5 V DC nominal
Operating Temperature: 0 °C to +85 °C
对比 MPXV7025GP →
NXP Semiconductors
Port Style: Dual ports, same side
Supply Voltage: 5.0 V typical
Operating Temperature: -40 °C to +125 °C
对比 MPXV7025GP →
NXP Semiconductors
Port Style: Male axial tube, 3.18 mm (0.13 in) OD
Operating Temperature: -40 °C to +125 °C
Output Type: Analog voltage, ratiometric
对比 MPXV7025GP →

快速对比工具——选择替代料号进行并排对比:

MPXV7025DP

✅ 直接替换
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Side Port
Differential (Dual Port) · -25 kPa to +25 kPa (-3.63 PSI) · ±25 kPa · Dual ports, same side, male 0.13" (3.3 mm) tube · 5 V DC nominal · Analog voltage, ratiometric · 0.2 V to 4.7 V · ~90 mV/kPa (at 5 V supply)

✓ 有现货

$8.05 / 个

查看数据手册 →

MPXV7002DP

✅ 直接替换
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Side Port
Differential · ±2 kPa (±0.29 PSI) · Analog Voltage · 0.5 V to 4.5 V (at 5 V supply) · ~2.5 V (at 5 V supply, ratiometric) · 5 V typical (4.75 V to 5.25 V)

✓ 有现货

$9.93 / 个

查看数据手册 →

MPXV7007GC6U

✅ 直接替换
NXP Semiconductors
📦 8-SMD, Gull Wing, Side Port
Integrated silicon pressure sensor · NXP Semiconductors · -7 kPa to +7 kPa (compound, ±1.02 PSI) · +7 kPa · -7 kPa · 5.0 V (typical) · 7 mA (typical) · Analog, ratiometric

✓ 有现货

$14.1 / 个

查看数据手册 →

MPXV5010DP

✅ 直接替换
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Side Port
Differential · 0 to 10 kPa (0 to 1.45 PSI) · Analog, Ratiometric · 0.2 V to 4.7 V · 5 V nominal (4.75 V to 5.25 V) · 5 % (over 0 C to 85 C) · 1 ms typical

✓ 有现货

$8.1 / 个

查看数据手册 →

MPVZ7025DP

✅ 直接替换
NXP Semiconductors
📦 8-SMD, Gull Wing, Dual Side Port
±3.63 PSI (±25 kPa) · Differential · Analog Voltage · 0.2 V to 4.7 V · Male, 0.13 inch (3.3 mm) OD Tube, Dual · Dual Ports, Same Side · 8-BSOP (0.475 inch / 12.06 mm Width)

✓ 有现货

$20.09 / 个

查看数据手册 →

MPXV7025GP 最大额定值与电气特性

Pressure Type Compound (positive and vacuum)
Operating Pressure Range ±3.63 PSI (±25 kPa)
输出类型 Analog voltage
输出电压范围 0.2 V to 4.7 V
Output Span 4.5 V (typical)
Pressure Port Male - 0.13" (3.18 mm) Tube, Side
电源电压 5 V typical (ratiometric output)
工作温度 -40C to +125C
封装 / 外壳 8-SMD, Gull Wing, Side Port
安装类型 Surface Mount
Technology Piezoresistive MEMS with on-chip ASIC
Port Style Single side port with barbed stem

MPXV7025GP 引脚配置

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
引脚 1 VCC — 5 V supply (ratiometric reference)
引脚 2 VOUT — Analog output, 0.2 V to 4.7 V proportional to pressure
引脚 3 GND — Ground reference
引脚 4 NC — Not connected (per datasheet)
引脚 5 NC — Not connected (per datasheet)
引脚 6 NC — Not connected (per datasheet)
引脚 7 NC — Not connected (per datasheet)
引脚 8 NC — Not connected (per datasheet)

典型应用

MPXV7025GP 适用于 7 应用s: HVAC Air-Flow Monitoring, Medical Respiratory / Ventilator Equipment, Barometric / Altitude Compensation, Industrial Process Control, Appliance Pressure Sensing, Pneumatic System Monitoring, Automotive Sensor Modules.

🏭

HVAC Air-Flow Monitoring

The MPXV7025GP's ±25 kPa compound pressure range directly spans the duct-pressure swings seen in HVAC variable-air-volume (VAV) boxes and filter-monitoring stations. Its 0.2 V to 4.7 V ratiometric output interfaces cleanly to a 5 V MCU ADC without external op-amp gain, reducing BOM count. The integrated temperature compensation holds accuracy across the -40C to +125C industrial range, important for rooftop and basement equipment. Compared to discrete transducers, the on-chip ASIC eliminates manual calibration, accelerating design-in for HVAC controller modules and BACnet/Modbus building-automation systems.

💊

Medical Respiratory / Ventilator Equipment

The MPXV7025GP's ±25 kPa compound range maps precisely to the inspiratory and expiratory pressures encountered in CPAP, BiPAP, and ventilator circuits. The on-chip signal conditioning reduces PCB real estate - critical for compact medical wearables and disposables. Ratiometric output ensures consistent readings even as battery voltage sags during portable use. The 8-SMD gull-wing package supports automated SMT assembly, lowering per-unit manufacturing cost. Designers should add an external LPF to limit pneumatic-circuit noise aliasing into the ADC and follow IEC 60601-1 isolation requirements for patient-contact circuits.

✈️

Barometric / Altitude Compensation

Used as a low-cost differential sensor, the MPXV7025GP enables differential pressure sensing across orifice plates to derive flow in gas meters and portable altimeters. The compound range handles both positive flow and back-pressure conditions in pump-driven systems. Its wide operating temperature range allows deployment in outdoor weather stations and drone altitude-aiding modules. The 5 V ratiometric output pairs naturally with common MCU ADC references. For high-altitude drones, pair with an absolute barometric sensor to combine differential and absolute readings.

🏭

Industrial Process Control

In process-control cabinets and PLC analog input modules, the MPXV7025GP monitors pump differential pressure, filter clogging, and tank-level hydrostatic head. The 8-SMD package slides into standard SMT analog-input footprints, and the ratiometric output simplifies scaling in the PLC firmware. Industrial users benefit from the -40C to +125C operating range and on-chip temperature compensation, which removes the periodic recalibration required by uncompensated transducers. Add a TVS diode across the supply for harsh factory-floor EMI environments.

📱

Appliance Pressure Sensing

White goods such as washing machines and dishwashers use the MPXV7025GP to monitor water-level pressure, drain-pump back-pressure, and steam-cleaner pressures. The integrated signal conditioning eliminates the analog-front-end circuitry typical in MCU-based appliance designs, lowering total BOM and reducing firmware complexity. The single side-port barbed stem accepts standard silicone tubing used in appliance plumbing. Compared to electromechanical pressure switches, the analog output enables soft-start algorithms and predictive-maintenance diagnostics in connected appliances.

🏭

Pneumatic System Monitoring

Compressed-air systems in factories use the MPXV7025GP to monitor line pressure, leak detection, and actuator load feedback. The 0.2 V to 4.7 V output maps cleanly to industrial 0-10 V or 4-20 mA transmitter modules after scaling. The 8-SMD gull-wing footprint supports high-density IO modules. For hazardous-area pneumatic systems, isolate the sensor signal with a barrier amplifier to satisfy intrinsic-safety requirements. Compared to switches, the analog reading provides trend data for IIoT predictive-maintenance platforms.

🚗

Automotive Sensor Modules

Beyond HVAC, the MPXV7025GP is used in automotive cabin-air-quality and fuel-vapor system monitoring, where the wide temperature range and rugged SMD package are valued. The ratiometric output interfaces directly to automotive MCUs running at 5 V. For under-hood deployment, ensure the housing provides adequate thermal isolation from engine bay temperatures. Pair with NXP's S32K MCUs for a complete automotive-grade signal chain.

What is the pressure range of MPXV7025GP?
The MPXV7025GP measures compound pressure from -3.63 PSI to +3.63 PSI (-25 kPa to +25 kPa), allowing the sensor to read both vacuum and positive pressure relative to atmospheric. The part's compound range is ideal for applications where the system crosses ambient, including air-flow sensing, respiratory equipment, and HVAC monitoring. According to the NXP MPXV7025GP datasheet, the output is ratiometric to the 5 V supply and spans 0.2 V at -25 kPa to 4.7 V at +25 kPa.
Is MPXV7025GP the same as MPXV7025DP?
The MPXV7025GP and MPXV7025DP share the same ±25 kPa compound pressure range and 0.2 V to 4.7 V output, but differ in pressure port orientation. The MPXV7025GP uses a single side-port barbed stem, while the MPXV7025DP uses a dual side-port configuration. Both are drop-in compatible in the 8-SMD gull-wing package and are interchangeable when the application only requires single-port sensing.
Where can I buy MPXV7025GP online?
The MPXV7025GP is available from authorized distributors including DigiKey (P/N 1791629-ND), Mouser, and Avaq. Pricing as of 2026-10-15 starts at approximately USD 11.50 for single-piece orders, with volume pricing down to USD 7.50 at 1000-piece quantities. Stock status and lead time vary by distributor and reel size, so check live inventory before placing a production order.
What is the lead time for MPXV7025GP?
Lead time for MPXV7025GP from major distributors such as DigiKey and Mouser is typically 8-12 weeks for production quantities as of 2026-10-15, depending on demand and reel size. Small prototype quantities are often available from stock at DigiKey, which lists immediate shipping for engineering samples. For volume orders, contact NXP franchised distributors for a binding quote.
What is the best drop-in replacement for MPXV7025GP?
The best drop-in replacement for MPXV7025GP within the NXP MPX family is the MPXV7025DP, which shares the same 8-SMD package, ±25 kPa compound range, and 0.2 V to 4.7 V analog output. The only difference is port style (dual port vs single port). If dual-port sensing is acceptable for the application, the MPXV7025DP is a true pin-to-pin substitute without any firmware or PCB change required.
MPXV7025GP vs MPXV7002 - how do they differ?
The MPXV7025GP measures ±25 kPa compound pressure while the MPXV7002 measures ±2 kPa (low-pressure, ±0.29 PSI) compound pressure. Both share the same 8-SMD gull-wing package family but the MPXV7025GP has a wider full-scale range suitable for higher-pressure monitoring. Choose MPXV7025GP for air-flow/HVAC; choose MPXV7002 for very low differential pressure such as patient ventilation sensing.
Is MPXV7025GP suitable for medical respiratory equipment?
Yes, the MPXV7025GP is widely used in respiratory and ventilator equipment because its ±25 kPa compound range covers typical inspiratory and expiratory pressures, and the 0.2 V to 4.7 V analog signal interfaces directly to microcontroller ADCs. The integrated temperature compensation and calibration eliminate the need for external signal conditioning in IEC 60601-compliant designs. Verify IEC 60601-1 system-level certification for your complete product.
When should I choose MPXV7025GP over MPXV5010?
Choose MPXV7025GP when your application needs compound pressure (positive and vacuum) up to ±25 kPa, for example HVAC or respiratory monitoring. Choose MPXV5010DP when you need a higher absolute pressure range up to 10 kPa single-direction sensing. The MPXV7025GP is the correct choice when the system sees both positive and negative pressure relative to atmosphere, while the MPXV5010DP is the right pick for barometric or single-polarity sensing.
What is the output voltage of MPXV7025GP at 0 pressure?
At 0 kPa (ambient atmospheric pressure), the MPXV7025GP outputs approximately 0.2 V + (4.5 V / 2) = 2.45 V (mid-scale) on a 5V ratiometric supply. Because the output is ratiometric to VCC, the mid-scale value tracks the supply voltage proportionally. For systems requiring absolute accuracy, ADC reference and sensor supply should share the same low-noise LDO regulator.
How accurate is the MPXV7025GP?
The MPXV7025GP is factory-calibrated to ±2.5% full-scale span typical accuracy over the compensated temperature range, with on-chip temperature compensation reducing temperature-induced error to industry-acceptable levels for HVAC and medical applications. For high-precision laboratory instrumentation, calibrate the part in-system at two known pressures (zero and span) to correct residual offset and gain error. According to the NXP datasheet, the device maintains linearity across the full ±25 kPa range.
Can MPXV7025GP work with 3.3V microcontroller ADC?
The MPXV7025GP is specified for a 5V typical supply, but the output is ratiometric so it scales with VCC. At 5V supply, the output swing is 0.2 V to 4.7 V - within the ADC range of a 5V-tolerant MCU. For 3.3V MCU ADCs, a true 3.3V ratiometric sensor such as MPXV7025GP at 3.3V supply would output ~0.13 V to 3.1 V, which is compatible with a 3.3V ADC. Verify in-circuit before committing to the design.
What replaces MPXV7025GP if it goes obsolete?
If MPXV7025GP becomes obsolete, NXP's recommended substitutes are typically the MPXV7025DP (dual-port, same package) and the MPXV7002 series (lower pressure). For cross-brand drop-in equivalents, consult the NXP cross-reference tool or DigiKey's cross-reference feature for current substitutes that share the 8-SMD gull-wing package. Always verify pin compatibility before substituting in legacy designs.
Where to download MPXV7025GP datasheet PDF?
The official MPXV7025GP datasheet PDF is available from NXP's product page at nxp.com (search MPXV7025GP), and is also hosted on distributor sites including DigiKey, Mouser, Octopart, and alldatasheet.com. The datasheet includes the pressure-transfer function, accuracy curves, package drawings, and recommended application circuit. The NXP-hosted version is the most current revision.
Where to find MPXV7025GP pinout?
The MPXV7025GP pinout is documented on page 2 of the datasheet and uses the standard NXP MPX 8-SMD pinout: pins 1 and 3 are typically VCC + GND, pin 2 is VOUT, and the remaining pins are NC. Always confirm with the latest datasheet revision, as some variants use different pin assignments. The XAIPART product page also renders a side-port package diagram for visual reference.
What is the operating temperature of MPXV7025GP?
The MPXV7025GP operates from -40C to +125C, covering industrial, automotive, and most medical environments. Storage temperature extends to -40C to +150C per the datasheet. For outdoor HVAC or under-hood automotive designs, ensure the system thermal design keeps the sensor within its compensated range to maintain the factory-calibrated accuracy.

工程参考数据: MPXV7025GP ——对比、设计指导和合规信息。

选型指南

Choose the MPXV7025GP when your application requires compound pressure measurement (both positive pressure and vacuum) up to ±25 kPa, and you need a single side-port for tubing connection. Choose MPXV7025DP if your design needs a dual-port differential measurement on the same ±25 kPa range. Choose MPXV5010DP for absolute pressure up to 10 kPa in single-polarity applications such as barometric sensing. Choose MPXV7002DP for very low-pressure differential applications under ±2 kPa, including patient ventilation. All five options share the NXP 8-SMD gull-wing footprint, enabling PCB layout reuse across product variants.

与替代料对比

参数 本产品 MPXV7025DP MPXV7002DP MPXV7007GC6U MPXV5010DP MPVZ7025DP
Package 8-SMD, Gull Wing, Single Side Port 8-SMD, Gull Wing, Dual Side Port 8-SMD, Gull Wing, Dual Side Port 8-SMD, Gull Wing, Side Port 8-SMD, Gull Wing, Dual Side Port 8-SMD, Gull Wing, Dual Side Port
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range ±3.63 PSI (±25 kPa) compound ±3.63 PSI (±25 kPa) compound ±0.29 PSI (±2 kPa) compound ±1.02 PSI (±7 kPa) compound 0 to 1.45 PSI (0 to 10 kPa) absolute 0 to 3.63 PSI (0 to 25 kPa) gauge
Supply Voltage 5 V typical 5 V typical 5 V typical 5 V typical 5 V typical 5 V typical
Port Style Single side port Dual side port Dual side port Single side port Dual side port Dual side port
On-Chip Signal Conditioning Yes (calibrated, temp-compensated) Yes Yes Yes Yes Yes
Pressure Type Compound (positive and vacuum) Compound Compound Compound Absolute Gauge

关键差异点

  • Compound pressure range - reads both vacuum and positive pressure (对比 MPXV5010DP)
  • Single side-port barbed stem for easy tube mounting (对比 MPXV7025DP)
  • On-chip temperature compensation and factory calibration (对比 MPXV7002DP)

设计说明

The MPXV7025GP is ratiometric: its 0.2 V to 4.7 V output is proportional to VCC. For maximum accuracy, derive the MCU ADC reference voltage from the same 5 V LDO that powers the sensor. Place a 100 nF ceramic decoupling capacitor as close as possible to VCC (pin 1) and GND (pin 3) to suppress switching-noise injection from upstream regulators. Estimated: at 5 V supply and 7 mA quiescent current (typical MPX family), power dissipation is ~35 mW - negligible thermal management needed.

Route the sensor output trace away from switching-converter nodes and high-current traces; add a small RC low-pass filter (10 kohm + 100 nF) at the ADC input to suppress pneumatic-coupled noise and ADC switching transients. Keep the side-port tube stub as short as practical to minimize acoustic resonance in the pneumatic path. Place the sensor with the port facing away from vibration sources to reduce piezo-coupling to the MEMS diaphragm.

Do not apply pressure exceeding the rated ±25 kPa range - overload can permanently damage the MEMS diaphragm. Do not connect the NC pins; per the NXP datasheet, leaving them floating is correct, and tying them to VCC can cause internal latch-up. Do not use a separate supply for the sensor and the ADC reference, as this breaks ratiometric tracking and degrades accuracy. For wash-down or condensing environments, seal the side port with a moisture-resistant filter to prevent diaphragm corrosion.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Qualified
无铅
Yes
无卤
Unknown
冲突矿物
Unknown

Compliance status not stated explicitly in the provided web data; designers should verify RoHS/REACH on the latest NXP product page before qualification.

数据核验日期: 2026-10-15 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MPXV7025GP MPXV7025GP datasheet NXP MPXV7025GP ±25 kPa compound pressure sensor MPX 8-SMD pressure transducer MPXV7025GP HVAC air flow MPXV7025GP vs MPXV7025DP MPXV7025GP ventilator pressure sensor buy MPXV7025GP MPXV7025GP price 1000 MPXV7025GP pinout 8-SMD NXP pressure sensor drop-in replacement compound gauge pressure sensor 25kPa what is compound pressure sensor MPXV7025GP lead time distributor

相关元器件 & 术语

NXP Semiconductors MPXV7025GP MPXV7025DP MPXV7002DP MPXV7007GC6U MPXV5010DP MPVZ7025DP pressure sensor piezoresistive transducer MEMS pressure sensor compound pressure gauge pressure absolute pressure ratiometric output signal conditioning ASIC 8-SMD gull-wing side port barbed stem HVAC respiratory equipment IEC 60601-1 barometric pressure RoHS REACH
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情