NVIDIA

MSN3700-VS2FC - 32x200GbE Spectrum-2 Switch | NVIDIA

料号: MSN3700-VS2FC ✓ 量产中
有现货 1-3 个工作日内发货
Up to 200GbE per port (series supports 1GbE to 400GbE) Speed
低至 $9100 USD / 件
最小起订量: 1 |
价格更新于: 2026-10-18
批量定价
数量 单价 小计
1 $10567.42 $10,567.42
10 $10300 $103,000.00
100 $9900 $990,000.00
500 $9500 $4,750,000.00
1,000 $9100 $9,100,000.00
ℹ️ 所有价格均以 USD 计价

MSN3700-VS2FC 概述

The NVIDIA (Mellanox) MSN3700-VS2FC is a 1U rack-mount Open Ethernet switch built on the Spectrum-2 ASIC, delivering 32 QSFP56 ports at up to 200GbE each (12.8 Tb/s aggregate throughput) with two AC power supplies, standard-depth chassis, x86 management CPU, P2C (port-to-connector) airflow, and Cumulus Linux pre-installed.

A data center switch is the top-of-rack or spine-layer device that interconnects servers, storage, and other switches in a leaf/spine fabric. Within the network equipment hierarchy, the MSN3700-VS2FC belongs to the NVIDIA Spectrum SN3000 series of Open Ethernet switch systems, positioned above 100G access platforms and alongside the modular SN3000 chassis products for cloud-scale deployments.

Key features include 32x QSFP56 ports supporting 1GbE through 400GbE speeds per the SN3000 series datasheet, full 12.8 Tb/s non-blocking fabric for rack-scale connectivity, redundant hot-swappable AC power supplies, and a Cumulus Linux operating environment enabling automation with standard DevOps tooling. The SN3000 series is purpose-built for leaf, spine, and super-spine data center topologies.

The Spectrum-2 ASIC provides flexible port speeds spanning 1GbE to 400GbE, allowing a single platform to serve mixed-speed fabrics. The x86 management CPU runs Cumulus Linux natively, supporting REST APIs, Ansible, and telemetry for cloud-style operations. P2C airflow matches typical forward-flow rack cooling, and the standard-depth chassis fits common 1U racks with the included rail kit.

Typical applications include 200G spine switches in hyperscale and enterprise data centers, VAST Data and high-performance NVMe storage fabric interconnects (the MSN3700-VS2FC is a listed VAST Data OPN), and AI/ML cluster leaf fabrics where 100G/200G server connectivity is required.

Design consideration: exact power consumption figures are not published in the available evidence; confirm AC power budget and PSU redundancy requirements with the manufacturer datasheet before finalizing rack power planning.

This page synthesizes distributor pricing, family cross-references, and practical deployment notes not consolidated in the manufacturer datasheet.

直接替换替代料: MSN3700-VS2FC ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: MSN3700-VS2FC (相同外形与封装尺寸) ——差异在于 Airflow, Power Supplies, Form Factor, ASIC, Forwarding Rate.

NVIDIA
Airflow: P2C (back-to-front)
Power Supplies: 2 x AC, redundant (100-264 V)
Form Factor: 1U rack-mountable
对比 MSN3700-VS2FC →
NVIDIA
Airflow: C2P (Connector-to-Power)
Power Supplies: 2 x AC, redundant
Form Factor: 1U rack-mountable, standard depth
对比 MSN3700-VS2FC →
NVIDIA
Airflow: P2C (Power-to-Connector) / back-to-front
Power Supplies: 2 x AC (hot-swappable)
Forwarding Rate: 8.33 Bpps
对比 MSN3700-VS2FC →
NVIDIA
Airflow: C2P (connector-to-panel)
Power Supplies: 2 x AC (redundant, hot-swappable)
Form Factor: 1U rack-mount, standard depth
对比 MSN3700-VS2FC →
NVIDIA
Airflow: Connector-to-Power (C2P)
Power Supplies: 2 x AC (redundant)
Form Factor: 1U rack-mount, standard depth
对比 MSN3700-VS2FC →

快速对比工具——选择替代料号进行并排对比:

MSN3700-VS2F

✅ 直接替换 ⚠️ 规格未核验
📦 1U rack-mount switch system
same SN3700 32x200GbE Spectrum-2 platform; suffix denotes PSU/accessory configuration differences (rail kit bundle)

📋 参考替代料(不在目录中)

MSN3700-VS2RC

✅ 直接替换 ⚠️ 规格未核验
NVIDIA
📦 1U rack-mount switch system
NVIDIA Spectrum SN3000 (SN3700) · NVIDIA Spectrum-2 (2nd generation) · 32 x QSFP56 · 200 GbE per port · 1GbE to 400GbE · 12.8 Tb/s · 8.33 Bpps · 1U rack-mount, standard depth

✓ 有现货

$26670 / 个

查看数据手册 →

MSN3700-CS2FC

✅ 直接替换 ⚠️ 规格未核验
NVIDIA
📦 1U rack-mount switch system
1U managed L3 Ethernet switch · Mellanox Spectrum-2 · 32 x 100GbE QSFP28 · 6.4 Tbps · 4.76 Bpps · 425 ns · 1GbE to 100GbE (splittable to 128 x 10/25GbE) · 1U rack-mountable

✓ 有现货

$1 / 个

查看数据手册 →

MSN3700-CS2RO

✅ 直接替换 ⚠️ 规格未核验
NVIDIA
📦 1U rack-mount switch system
1U Open Ethernet switch (bare metal, ONIE) · NVIDIA Spectrum-2 (SN3700C) · 32 x 100GbE QSFP28 · Up to 100 Gb/s per port (1GbE to 400GbE across SN3000 series) · 12.8 Tb/s · Up to 8.33 Bpps · L3 managed · ONIE (Open Network Install Environment)

✓ 有现货

$8300 / 个

查看数据手册 →

SSE-SN3700-VS2RC

✅ 直接替换
📦 1U rack-mount switch system
same Spectrum-2 ASIC, 32x200G 1U Open Networking platform, 12.8 Tb/s; EOL per Supermicro - remaining stock only

📋 参考替代料(不在目录中)

MSN3700-VS2FC 最大额定值与电气特性

Product Series NVIDIA Spectrum SN3000 (SN3700)
ASIC NVIDIA Spectrum-2
Port Count 32 QSFP56 ports
Port Speed Up to 200GbE per port (series supports 1GbE to 400GbE)
Aggregate Throughput 12.8 Tb/s
Form Factor 1U rack-mount
Chassis Depth Standard depth
Power Supplies 2x AC PSU (redundant, hot-swappable)
Airflow P2C (port-to-connector)
Management CPU x86
Operating System Cumulus Linux (pre-installed)
Management Software Cumulus Linux / NVIDIA ONYX-compatible ecosystems
Included Accessories Rail kit
Typical Deployment Leaf / spine / super-spine

MSN3700-VS2FC standard 引脚配置指南

MSN3700-VS2FC(standard 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。

MSN3700-VS2FC 的 standard 封装引脚图

暂无详细引脚数据: MSN3700-VS2FC.

请参阅 数据手册 以查看完整引脚配置。

典型应用

MSN3700-VS2FC 适用于 6 应用s: 200G Data Center Spine Switch, High-Performance NVMe Storage Fabric, AI/ML Cluster Leaf Fabric, Enterprise Data Center Leaf/Spine Upgrade, Super-Spine / Pod Interconnect, Surveillance and IP Security Network Core.

🖥️

200G Data Center Spine Switch

The MSN3700-VS2FC fits the spine role of leaf/spine fabrics where every leaf downlink must run at line rate: its 32 QSFP56 ports and 12.8 Tb/s non-blocking Spectrum-2 fabric provide full-bandwidth connectivity to up to 32 leaf switches at 200GbE each, per the NVIDIA SN3000 series datasheet. Deployed at the spine layer, each port aggregates multiple 100G leaf uplinks or connects directly to 200G-ready leaf platforms, and the SN3000 series spans 1GbE to 400GbE so migration does not require a hardware refresh. Running Cumulus Linux on the x86 CPU, spine provisioning is automated through standard DevOps tooling, with telemetry for fabric-wide monitoring. Redundant AC PSUs and 1U standard-depth chassis match typical data center spine rack constraints.

🖥️

High-Performance NVMe Storage Fabric

The MSN3700-VS2FC is a listed NVIDIA OPN for VAST Data clusters (VAST SKU ETH-NVMEF-1X32-200G), where storage traffic benefits directly from its 12.8 Tb/s non-blocking fabric and 32x 200GbE QSFP56 ports. In NVMe-oF and disaggregated storage architectures, each storage server or enclosure connects at 100G/200G, and any oversubscription shows up as tail-latency degradation on I/O; the Spectrum-2 ASIC's line-rate forwarding keeps east-west storage traffic predictable. Cumulus Linux on the integrated x86 CPU enables consistent automation with the compute fabric, while dual AC PSUs protect against single-supply failure in storage-critical racks. P2C airflow and the 1U standard-depth form factor fit standard storage racks without special cooling provisions.

🖥️

AI/ML Cluster Leaf Fabric

AI training clusters generate intense east-west traffic during gradient synchronization, and the MSN3700-VS2FC serves as a leaf switch providing 100G/200G server uplinks with 12.8 Tb/s of fabric capacity, minimizing buffer-induced jitter under all-to-all traffic bursts. The SN3000 series supports port speeds from 1GbE to 400GbE per NVIDIA's datasheet, so a single leaf platform accommodates 25G/50G/100G server NICs today and migrates to 200G without replacement. Cumulus Linux exposes standard interfaces for integration with cluster schedulers and telemetry pipelines used in AI infrastructure. Two redundant AC PSUs sustain availability through the multi-day training runs typical of large model workloads, and the 1U chassis maximizes rack compute density.

🌐

Enterprise Data Center Leaf/Spine Upgrade

Enterprises consolidating legacy 10G/40G networks onto modern 100G/200G fabrics can deploy the MSN3700-VS2FC incrementally: the SN3000 series' 1GbE-to-400GbE port-speed flexibility per the NVIDIA datasheet lets legacy 40G and new 100G/200G links coexist during transition. As a spine, its 32 ports support large multi-pod designs; as a leaf, it connects up to 32 servers or storage systems with headroom for growth. Cumulus Linux brings cloud-style automation (Ansible, REST API) to enterprise operations teams, and the x86 CPU hosts telemetry agents for monitoring integration. The dual-PSU, 1U standard-depth hardware with rail kit installs into existing enterprise racks without infrastructure changes.

🌐

Super-Spine / Pod Interconnect

The NVIDIA SN3000 series is explicitly positioned for super-spine deployments, and the MSN3700-VS2FC aggregates multiple leaf/spine pods into a two-tier super-spine fabric: each 200GbE QSFP56 port carries pod uplinks while the 12.8 Tb/s Spectrum-2 fabric keeps inter-pod traffic non-blocking. For cloud and large enterprise operators building three-tier topologies, this platform allows 100G pod uplinks today with a path to 200G/400G, since the series spans 1GbE to 400GbE port speeds per the datasheet. Cumulus Linux on the x86 CPU supports the automation scale required at super-spine layers, where hundreds of links are managed programmatically, and redundant hot-swappable AC PSUs meet the high-availability requirements of the network core.

🎥

Surveillance and IP Security Network Core

Large-scale IP surveillance deployments aggregate hundreds of high-bitrate camera streams; per published reseller information, the MSN3700-VS2FC integrates into NVIDIA's broader Spectrum switch portfolio and supports standard data center network management protocols used in surveillance networks. Its 32x 200GbE QSFP56 ports and 12.8 Tb/s fabric absorb massive many-to-one video traffic toward recording servers without the congestion that causes frame loss, and QSFP56 breakouts accommodate 10G/25G camera-side aggregation switches. Cumulus Linux with the x86 CPU enables segmented, monitored topologies typical of security networks, while dual redundant AC PSUs maintain continuous recording availability. The 1U standard-depth chassis with P2C airflow installs in standard surveillance equipment racks.

推荐产品汇总

MSN3700-VS2F Sibling SN3700 SKU for mixed airflow racks 用于: 200G Data Center Spine Switch, High-Performance NVMe Storage Fabric, Enterprise Data Center Leaf/Spine Upgrade, Super-Spine / Pod Interconnect SSE-SN3700-VS2RC Supermicro Spectrum-2 equivalent (EOL stock) 用于: 200G Data Center Spine Switch MSN3700-VS2RC NVIDIA 用于: AI/ML Cluster Leaf Fabric, Surveillance and IP Security Network Core
What is the MSN3700-VS2FC?
The MSN3700-VS2FC is an NVIDIA (Mellanox) Spectrum SN3700 series 1U Open Ethernet switch with 32 QSFP56 ports running at up to 200GbE each, delivering 12.8 Tb/s of aggregate throughput. It is based on the Spectrum-2 ASIC, includes two AC power supplies, a standard-depth chassis, an x86 management CPU, P2C airflow, a rail kit, and comes with Cumulus Linux pre-installed, per the NVIDIA SN3000 series datasheet.
What is the price of MSN3700-VS2FC?
As of 2026-10-19, a listed market reference for the MSN3700-VS2FC is approximately US$10,567.42 for a Cumulus Linux-loaded refurbished unit from ETB Technologies. New-unit pricing varies by distributor and configuration; request a quote from XAIPART for current volume pricing. Prices fluctuate with availability, so verify freshness at order time.
Where to buy MSN3700-VS2FC online?
The MSN3700-VS2FC can be purchased through XAIPART as well as third-party resellers including Router-Switch, ETB Technologies, and Richard Electronics, all of which list the part. Availability on Octopart aggregates multiple distributor stock sources. For data center quantities, request a formal quote, as lead times and configuration (PSU type, airflow direction, OS image) should be confirmed before ordering.
Is MSN3700-VS2FC in stock and what is the lead time?
Stock status for the MSN3700-VS2FC varies by channel; Octopart lists multiple distributor sources, and refurbishers such as ETB Technologies list the unit, indicating secondary-market availability. Exact lead time is [not published in verified data]; contact XAIPART sales for real-time stock and lead time. Note that NVIDIA networking SKUs frequently route through channel partners rather than catalog distribution.
What is the difference between MSN3700-VS2FC and MSN3700-VS2F?
The MSN3700-VS2FC and MSN3700-VS2F are the same Spectrum-2 based SN3700 hardware platform with 32x 200GbE QSFP56 ports; the suffix encodes configuration options such as PSU/airflow and accessory bundle. The VS2FC configuration ships with two AC PSUs, P2C airflow, and a rail kit. Both run Cumulus Linux on the x86 CPU; verify the exact suffix decode on NVIDIA's SN3000 ordering-information page before ordering.
MSN3700-VS2FC vs Supermicro SSE-SN3700-VS2RC - which is better?
Both are Spectrum-2 based 32-port 200G Open Networking switches with 12.8 Tb/s throughput. The Supermicro SSE-SN3700-VS2RC is now discontinued (EOL) per Supermicro's product page, so new designs should use the NVIDIA MSN3700-VS2FC, which remains an active NVIDIA SKU and is the OPN referenced by VAST Data. For existing Supermicro deployments, NVIDIA's part is the supported forward path.
Can MSN3700-VS2FC replace MSN3700-CS2FC?
Yes, the MSN3700-VS2FC can serve the same 32x200GbE Spectrum-2 switching function as the MSN3700-CS2FC in most leaf/spine deployments; both are 1U SN3700-family systems. The suffix differences typically denote airflow direction, PSU type, and accessory configuration. Since airflow must match rack cooling direction, confirm the CS2FC suffix meaning on NVIDIA's SN3000 ordering page before substituting.
When should I choose the MSN3700-VS2FC over smaller SN3000 series switches?
Choose the MSN3700-VS2FC when you need a full 32 ports of 100G/200G in a single 1U with 12.8 Tb/s of fabric bandwidth - typically as a spine switch, storage fabric switch (as in VAST Data clusters), or high-density AI/ML leaf. If your ports need to break out to 25G/50G server speeds, the QSFP56 ports support it, but verify breakout support in the SN3000 datasheet. For lower port counts, smaller SN3000-family models may be more economical.
What is the best drop-in replacement for MSN3700-VS2FC?
The closest drop-in replacements are sibling SN3700 SKUs: MSN3700-VS2F (same platform, different suffix configuration) and MSN3700-VS2RC (reversed-airflow variant) occupy the same 1U chassis and slot with the same port configuration. Because these are rack-mount systems rather than soldered ICs, replacement requires matching airflow direction, PSU type, and the Cumulus Linux image rather than a physical footprint.
What is the NVIDIA equivalent for MSN3700-VS2FC from another brand?
The best cross-brand equivalent found in published data is the Supermicro SSE-SN3700-VS2RC (and its VS2FC variant), a Spectrum-2 based 32-port 200G Open Networking switch in 1U - functionally equivalent hardware built on the same NVIDIA ASIC. However, Supermicro lists this series as discontinued (EOL) and directs customers to alternative options, so the active NVIDIA MSN3700-VS2FC remains the recommended sourcing choice.
Where to download the MSN3700-VS2FC datasheet PDF?
The official datasheet is the NVIDIA Spectrum SN3000 Series Switches PDF, available at nvidia.com under the networking solutions section (sn3000-series-datasheet-1557133.pdf). It covers port configurations, speeds from 1GbE to 400GbE, and target leaf/spine/super-spine use cases. Installation and configuration details are in the NVIDIA Spectrum-2 SN3000 1U and 2U Switch Systems Hardware User Manual on docs.nvidia.com.
What power supply configuration does the MSN3700-VS2FC use?
The MSN3700-VS2FC includes two AC power supplies in a redundant, hot-swappable configuration within its 1U standard-depth chassis. Exact power consumption figures are not provided in the available evidence; consult the NVIDIA SN3000 series datasheet or NVIDIA support to confirm wattage before finalizing rack power budgets. The dual-PSU design supports N+1 redundancy when fed from independent power circuits.
Is MSN3700-VS2FC suitable for 100G leaf networks?
Yes. Although each QSFP56 port supports up to 200GbE, the SN3000 series spans port speeds from 1GbE to 400GbE per the NVIDIA datasheet, allowing the MSN3700-VS2FC to operate ports at 100G for leaf connections or breakout to lower speeds where supported. Its 12.8 Tb/s non-blocking fabric provides headroom for future migration from 100G to 200G server connectivity without replacing hardware.
What are the key specifications of MSN3700-VS2FC that engineers should know?
Core specifications: Spectrum-2 ASIC; 32 QSFP56 ports at up to 200GbE; 12.8 Tb/s aggregate throughput; 1U standard-depth chassis; two redundant AC PSUs; P2C airflow; x86 management CPU; Cumulus Linux pre-installed; rail kit included; series port-speed range 1GbE to 400GbE; designed for leaf/spine/super-spine data center topologies. Typical power consumption is not published in available data and should be confirmed with NVIDIA.
What can replace MSN3700-VS2FC if unavailable?
If the MSN3700-VS2FC is unavailable, first check sibling NVIDIA SKUs (MSN3700-VS2F, MSN3700-VS2RC) which share the same Spectrum-2 32x200GbE platform with different airflow/PSU/accessory suffixes. The Supermicro SSE-SN3700-VS2RC series is hardware-equivalent but EOL and available only as remaining stock or refurbishment. Refurbished MSN3700-VS2FC units are offered by vendors such as ETB Technologies with warranty options.

工程参考数据: MSN3700-VS2FC ——对比、设计指导和合规信息。

选型指南

Choose the MSN3700-VS2FC when you need an active-manufacturer, 32-port 200GbE spine or high-density leaf switch with 12.8 Tb/s non-blocking throughput, P2C airflow, dual AC PSUs, and Cumulus Linux pre-installed - typical for hyperscale, enterprise leaf/spine, AI/ML, and VAST Data storage fabrics. Choose sibling SKUs when rack conditions differ: MSN3700-VS2RC for reversed (C2P) airflow racks, MSN3700-VS2F when a different accessory bundle is preferred, and MSN3700-CS2FC/CS2RO for alternate PSU/NOS configurations (verify suffix decode on NVIDIA's ordering page). Choose the Supermicro SSE-SN3700-VS2RC only when absorbing an existing Supermicro-based fabric, and accept that it is EOL with no forward hardware path. For all variants, confirm power consumption, optics compatibility, and OS image before purchase.

与替代料对比

参数 本产品 MSN3700-VS2F MSN3700-VS2RC MSN3700-CS2FC SSE-SN3700-VS2RC
Package (Form Factor) 1U rack-mount standard depth 1U rack-mount standard depth 1U rack-mount standard depth 1U rack-mount standard depth 1U rack-mount
Brand NVIDIA (Mellanox) NVIDIA (Mellanox) NVIDIA (Mellanox) NVIDIA (Mellanox) Supermicro
Switch ASIC NVIDIA Spectrum-2 NVIDIA Spectrum-2 NVIDIA Spectrum-2 NVIDIA Spectrum-2 NVIDIA Spectrum-2
Ports 32x QSFP56 up to 200GbE 32x QSFP56 up to 200GbE 32x QSFP56 up to 200GbE 32x QSFP56 up to 200GbE 32x 200G
Aggregate Throughput 12.8 Tb/s 12.8 Tb/s 12.8 Tb/s 12.8 Tb/s 12.8 Tb/s
Operating System Cumulus Linux (pre-installed) Cumulus Linux Cumulus Linux Cumulus Linux / ONYX Cumulus Linux
Lifecycle Status Active Active Active Active EOL (Discontinued)

关键差异点

  • Active NVIDIA SKU with long-term support path (对比 SSE-SN3700-VS2RC)
  • Full 12.8 Tb/s non-blocking fabric in 1U (对比 MSN3700-VS2F)
  • Cumulus Linux automation out of the box (对比 MSN3700-CS2FC)

设计说明

The MSN3700-VS2FC ships with two redundant hot-swappable AC PSUs; exact power consumption is not published in available evidence, so rack power budgets must be confirmed against the NVIDIA SN3000 series datasheet or NVIDIA pre-sales engineering before deployment. Feed the two PSUs from independent power circuits (A/B feeds) to realize true N+1 redundancy, and verify PDU outlet ratings and branch circuit capacity with margin for peak and inrush conditions.

The VS2FC suffix specifies P2C (port-to-connector) airflow: air enters at the port side and exhausts at the PSU side. Mismatching airflow direction with rack cooling (hot-aisle/cold-aisle arrangement) causes hot-air recirculation and thermal throttling risk. If your rack airflow is reversed, select the MSN3700-VS2RC variant instead. Verify the ordering suffix on NVIDIA's SN3000 ordering-information page, since NVIDIA documentation specifically warns to pay attention to airflow direction when ordering.

Confirm the intended operating system image before deployment: the VS2FC configuration comes with Cumulus Linux, but other SN3700 SKUs may ship with ONYX or other loads per NVIDIA ordering information. Migrating between NOS images requires re-imaging via ONIE. Also note port speed flexibility (1GbE to 400GbE across the series) depends on the transceiver/SFP module used - use NVIDIA-qualified QSFP56/QSFP28 optics and DACs to avoid link-training and firmware compatibility issues.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Compliance declarations for complete switch systems are published by NVIDIA; not present in the retrieved web data. Consult the NVIDIA SN3000 datasheet or product compliance documentation.

数据核验日期: 2026-10-19 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

MSN3700-VS2FC MSN3700-VS2FC datasheet NVIDIA MSN3700-VS2FC Spectrum-2 switch Mellanox SN3700 32x200GbE QSFP56 switch price MSN3700-VS2FC vs MSN3700-VS2F difference MSN3700-VS2FC drop-in replacement Supermicro SSE-SN3700-VS2RC equivalent MSN3700-VS2FC 200G spine switch data center VAST Data MSN3700-VS2FC storage fabric switch buy MSN3700-VS2FC 1U 200GbE switch MSN3700-VS2FC power consumption watts what is MSN3700-VS2FC

相关元器件 & 术语

NVIDIA Mellanox MSN3700-VS2FC MSN3700-VS2F MSN3700-VS2RC MSN3700-CS2FC SSE-SN3700-VS2RC Supermicro Spectrum-2 ASIC Spectrum SN3000 series SN3700 QSFP56 200GbE Cumulus Linux Open Ethernet leaf/spine architecture VAST Data RoHS 12.8 Tb/s throughput 1U rack-mount switch P2C airflow ONYX ONIE
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情