OPA2187ID 概述

The Texas Instruments OPA2187ID is a dual, zero-drift CMOS precision operational amplifier with 10 uV input offset voltage, 0.001 uV/C offset drift, and an 8-pin SOIC package. It operates from 4.5 V to 36 V, supports rail-to-rail output, is unity-gain stable, and is optimized for low-power precision signal conditioning. The OPA2187ID combines two amplifiers in one package, reducing board area while preserving the low-offset characteristics required in current sensing, instrumentation, sensor interfaces, and test equipment.

A zero-drift operational amplifier is a precision amplifier whose input offset voltage and associated drift are continuously corrected to minimize changes caused by temperature and time. In the broader component hierarchy, the OPA2187ID is a dual operational amplifier, within the class of analog signal-chain ICs and power-management-adjacent measurement devices. Its zero-drift architecture differs from conventional CMOS amplifiers, whose input offset can move appreciably as junction temperature changes. This makes the device useful when measurement accuracy must remain stable over a wide ambient-temperature range.

The principal benefits include 10 uV input offset voltage, 0.001 uV/C input offset drift, low-power operation, a 4.5 V to 36 V supply range, and rail-to-rail output capability. MUX-friendly operation helps the device coexist with multiplexed sensor networks, while the dual configuration allows differential, transimpedance, bridge excitation, and signal-conditioning functions to be implemented without using two separate packages. The wide supply range also permits operation from conventional 5 V and 12 V rails through higher industrial voltage systems, subject to the complete operating specification.

Internally, the zero-drift architecture is intended to provide stable DC performance without the continuous chopping noise commonly associated with some auto-zeroed amplifiers. The OPA2187 family supports general-purpose precision applications and uses a CMOS process. The dual OPA2187ID is specified for operation from -40 C to +125 C. Its low offset and drift are particularly valuable in slow-signal measurement paths where input offset error can dominate the available signal span and where temperature variation must not materially change the measurement result.

Typical uses include weighing and force measurement, pressure and temperature sensor conditioning, low-side current sensing, buffered transducer outputs, precision bridge amplifiers, laboratory instrumentation, and industrial control modules. In each case, the two amplifier channels can process complementary or differential signals while sharing a common supply. Engineers should still account for input bias current, noise bandwidth, common-mode behavior, output drive, and the external resistor network when calculating total measurement error.

A practical design consideration is to keep sensitive input traces short, route them away from switching nodes, and use a stable low-noise reference or sensor source. Because precision amplifiers reject offsets but not gain, resistor tolerances, thermoelectric effects, excitation drift, or noise, the OPA2187ID should be combined with high-accuracy passive components. The 8-pin SOIC package supports conventional surface-mount assembly and straightforward replacement with a verified pin-compatible alternative.

This product page combines the manufacturer specifications, package and pin information, pricing workflow, comparison criteria, drop-in candidates, and application-specific engineering guidance. It is designed to help engineers move from device selection to PCB implementation while recognizing which parameters require direct confirmation in the manufacturer datasheet.

直接替换替代料: OPA2187ID ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: OPA2187ID (相同外形与封装尺寸) ——差异在于 Amplifier Type, Operating Temperature Range, Output Swing.

Texas Instruments
Amplifier Type: Zero-drift operational amplifier
Operating Temperature Range: -40°C to +105°C
Output Swing: Rail-to-rail output within 18 mV of the rails
对比 OPA2187ID →

OPA2188ID

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOIC
Lower input-offset rating than the OPA2187ID's 10 uV, while retaining the same 8-pin SOIC footprint and zero-drift architecture

📋 参考替代料(不在目录中)

OPA2189ID

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOIC
Lower input-offset rating than the OPA2187ID's 10 uV, with the same 8-pin SOIC footprint and different bandwidth and precision trade-offs

📋 参考替代料(不在目录中)

OPA2187IDR

✅ 直接替换 ⚠️ 规格未核验
📦 8-pin SOIC
Identical 10 uV offset and 0.001 uV/C drift ratings; only the tape-and-reel ordering form differs

📋 参考替代料(不在目录中)

OPA2187ID 最大额定值与电气特性

Amplifier Type Zero-drift precision operational amplifier
Number of Channels 2 channels
Input Offset Voltage 10 uV
Input Offset Voltage Drift 0.001 uV/C
Supply Voltage Range 4.5 V to 36 V
Output Swing Rail-to-rail output
Gain Configuration Unity-gain stable
Process Technology CMOS
MUX Compatibility MUX-friendly
Power Classification Low power
工作温度范围 -40 C to +125 C
封装 8-pin SOIC
安装类型 Surface mount
Manufacturer Texas Instruments

OPA2187ID 引脚配置

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
引脚 1 OUTA — Output of amplifier A
引脚 2 INA- — Inverting input of amplifier A
引脚 3 INA+ — Noninverting input of amplifier A
引脚 4 V- — Negative supply connection
引脚 5 INB+ — Noninverting input of amplifier B
引脚 6 INB- — Inverting input of amplifier B
引脚 7 OUTB — Output of amplifier B
引脚 8 V+ — Positive supply connection

典型应用

OPA2187ID 适用于 6 应用s: Precision Weight and Force Measurement, Low-Side Current Sensing, Industrial Pressure Sensor Interface, Precision Data Acquisition, Low-Level Voltage Buffering, Battery and Power-System Monitoring.

⚖️

Precision Weight and Force Measurement

The OPA2187ID is well suited to bridge-based weighing and force sensing because its 10 uV input offset and 0.001 uV/C drift limit temperature-dependent errors in small differential sensor outputs. Place one channel in an instrumentation arrangement and use the second channel for excitation monitoring, reference buffering, or an independent diagnostic input. The 4.5 V to 36 V supply range supports portable and industrial systems, while rail-to-rail output provides useful signal swing. Keep the high-impedance amplifier inputs short, isolate them from switching traces, and include gain-setting resistors with suitable tolerance and temperature coefficient so that practical system accuracy reflects component stability rather than amplifier offset alone.

⚡

Low-Side Current Sensing

The OPA2187ID can amplify the small differential voltage generated by a low-side shunt in power monitoring, battery management, motor control, and laboratory instrumentation. Its 10 uV offset is valuable when the shunt voltage is only a few millivolts, while the 0.001 uV/C drift helps preserve measurement consistency over temperature. The dual amplifier allows one channel to monitor the shunt and the other to monitor a scaled supply or reference signal. Because the input offset is only one part of the error budget, also evaluate shunt tolerance, amplifier input bias current, resistor ratios, noise bandwidth, and the common-mode voltage present at the shunt.

🏭

Industrial Pressure Sensor Interface

The OPA2187ID fits resistive pressure and position transducers whose differential outputs are small and susceptible to offset error. Its 10 uV input offset and 0.001 uV/C drift improve DC stability across industrial temperature changes, while the 4.5 V to 36 V supply range supports a broad range of sensor excitation systems. One channel can amplify the bridge output and the other can condition a temperature-compensation or diagnostic signal. Follow good analog layout practices: keep input routing short, place input-protection components away from sensitive pins, separate switching-current paths from the bridge, and verify the amplifier's common-mode limits against the selected excitation voltage and sensor output range.

🖥️

Precision Data Acquisition

The OPA2187ID is useful as a low-offset front end for slow analog measurements in data-acquisition equipment, especially when the source is a low-level sensor rather than a high-speed signal. The zero-drift topology addresses input-offset changes with temperature and time, making the amplifier useful in multichannel measurement boards where calibration drift affects accuracy. Two channels can provide differential excitation, gain, or reference functions while conserving board space. Bandwidth should be selected to cover the required measurement bandwidth without admitting unnecessary noise, and system error must include ADC input range, reference accuracy, source impedance, and resistor-network tolerance. Stable references and careful grounding are as important as the amplifier itself.

📡

Low-Level Voltage Buffering

The OPA2187ID can buffer low-level voltage sources without introducing substantial temperature-dependent offset movement. It is appropriate for potentiometer-like dividers, reference voltages, diagnostic signals, and sensor outputs where a high-impedance input and stable DC response are more important than wideband performance. Rail-to-rail output helps preserve signal range in single-supply systems, and the broad 4.5 V to 36 V operating range supports both low-voltage portable equipment and industrial rails. Confirm whether the source requires a conventional rail-to-rail input range, since the published family headline specifies rail-to-rail output. For critical buffers, account for input bias current across source impedance and use low-leakage protection components.

🔋

Battery and Power-System Monitoring

The OPA2187ID supports battery-management and power-system monitoring circuits that require accurate measurement of small differential voltages. Its 10 uV offset improves resolution near zero, while the 0.001 uV/C drift helps maintain repeatability when a battery pack, shunt, or protection circuit operates over a wide temperature range. The dual channels can monitor a current signal and a temperature or pack-voltage signal, reducing the number of analog packages required. The 4.5 V minimum supply supports low-voltage systems, and the 36 V maximum supports higher industrial bus voltages. Account for transient protection, shunt common-mode limits, input filtering, and system calibration when laying out the circuit.

Where can I buy OPA2187ID online?
Use the Request a Quote form on this page to request OPA2187ID pricing, stock confirmation, and current lead time. The form is the direct route for a unit-price check and quantity quotation without relying on stale catalog pricing. The device is the Texas Instruments 8-pin SOIC ordering option for the dual OPA2187 zero-drift amplifier, so specify OPA2187ID exactly when requesting an order.
What is the price of OPA2187ID?
The current OPA2187ID price is not stated on this page because the Request a Quote workflow calculates live commercial terms. Submit the form on this page with the required quantity and packaging information to obtain a current quotation. This approach is important for this precision amplifier because distributor pricing can vary with order quantity, date, and authorized-channel availability.
What is the lead time for OPA2187ID?
Request the current OPA2187ID lead time through the Request a Quote form on this page. Texas Instruments identifies OPA2187ID as an orderable part offered in an 8-pin SOIC package, but a production lead time should be confirmed for the selected quantity. Include the required delivery date and target annual usage when requesting the quotation.
Is OPA2187ID in stock?
Submit the Request a Quote form on this page to check current OPA2187ID stock and allocation status. Stock availability can change with order size and replenishment timing, so an archived inventory statement is not a reliable substitute for a live confirmation. Identify the exact OPA2187ID suffix and the required shipment quantity in the request.
What are the key specifications of OPA2187ID that engineers should know?
The OPA2187ID is a dual zero-drift operational amplifier with 10 uV input offset, 0.001 uV/C offset drift, a 4.5 V to 36 V supply range, rail-to-rail output, and unity-gain stability. According to the Texas Instruments OPAx187 family datasheet, it is a low-power, MUX-friendly CMOS precision amplifier packaged in an 8-pin SOIC. Its specified operating-temperature range is -40 C to +125 C.
What is the operating voltage of OPA2187ID?
The OPA2187ID operates from 4.5 V to 36 V according to the Texas Instruments OPAx187 family datasheet. The two amplifier channels share this supply range. Rail-to-rail output allows the output to approach the supply rails, while actual output limits under load must be evaluated from the complete datasheet electrical-characteristics table.
Is OPA2187ID suitable for precision sensor conditioning?
The OPA2187ID is suitable for precision sensor conditioning because its input offset voltage is 10 uV and its offset drift is only 0.001 uV/C. Those characteristics reduce temperature-dependent error in bridge, pressure, temperature, force, and low-level current measurements. The amplifier does not correct gain drift or sensor errors, so accurate external resistors and suitable excitation or reference sources remain part of the measurement design.
What is the difference between OPA2187ID and OPA2188ID?
OPA2187ID and OPA2188ID are dual zero-drift alternatives within the same Texas Instruments precision-amplifier family and use the same 8-pin SOIC footprint. Their principal selection difference is the offset-voltage and related precision rating, with OPA2187ID specified at 10 uV input offset and OPA2188ID offering a different lower-offset rating. Confirm gain-bandwidth, noise, common-mode, and supply details in the family datasheet before substitution.
OPA2187ID vs OPA2189ID - which is better for a low-level sensor?
Choose OPA2187ID when its 10 uV offset and 0.001 uV/C drift are adequate and lower bandwidth or power consumption is preferable. Consider OPA2189ID when the lower-offset zero-drift rating of that family member better matches a very small sensor output. The correct choice also depends on noise, gain-bandwidth product, supply voltage, and settling behavior, which must be compared in the manufacturer documentation.
When should I choose OPA2187ID over OPA2188ID?
Choose OPA2187ID when 10 uV input offset and 0.001 uV/C drift satisfy the measurement error budget and the design does not require the lower-offset performance associated with OPA2188ID. OPA2187ID is appropriate for many precision current, bridge, and transducer interfaces where its rail-to-rail output and 4.5 V to 36 V supply range are advantageous. Choose the lower-offset member only when the added precision materially improves the result.
When should I choose OPA2187ID over OPA2189ID?
Choose OPA2187ID when its 10 uV offset and 0.001 uV/C drift provide sufficient accuracy without paying for or compensating for the higher precision of OPA2189ID. It is a practical choice for industrial sensor interfaces that need stable DC performance but do not require extremely low offset. Compare bandwidth and noise as well, since lower offset alone does not guarantee better total measurement performance.
What can replace OPA2187ID?
The closest same-family candidates are OPA2188ID and OPA2189ID, which use the same 8-pin SOIC arrangement but have different precision ratings. OPA2187IDR is the tape-and-reel ordering form of the same device rather than a different electrical design. Validate package pinout, supply range, common-mode limits, bandwidth, noise, enable behavior, and stability before approving any replacement.
Is OPA2187ID the same as OPA2187IDR?
OPA2187IDR represents the reel-oriented ordering form of the OPA2187ID device, whereas OPA2187ID is the base 8-pin SOIC ordering designation. Their electrical function is the same within the Texas Instruments ordering system, but the packing method differs, so the exact suffix must match the assembly and incoming-receipt requirements. Confirm the orderable drawing and tape orientation before substitution.
What is the best Analog Devices equivalent for OPA2187ID?
The available cross-reference results do not identify a verified Analog Devices part that is guaranteed to be pin-to-pin and parametrically equivalent to the OPA2187ID. Do not treat a generic precision op amp as a drop-in replacement. A valid equivalent must match the 8-pin SOIC pinout, 4.5 V to 36 V supply, common-mode behavior, offset and drift, bandwidth, noise, stability, and output-drive requirements.
Where can I download the OPA2187ID datasheet PDF?
Download the official OPA2187ID datasheet from the Texas Instruments link listed on this page. The document covers the OPAx187 family, including the dual OPA2187 in 8-pin SOIC packaging. Use the manufacturer pin-description table and electrical-characteristics section when assigning tracks, selecting external components, and checking the complete operating limits.
Where can I find the OPA2187ID pinout?
The OPA2187ID pinout is available in the Texas Instruments OPAx187 family datasheet and the OPA2187 product information linked on this page. For the 8-pin SOIC, use the pin-description table to assign the two amplifier inputs, outputs, supply pins, and ground. Follow the package drawing and pin-1 orientation shown on the manufacturer mechanical documentation when laying out the PCB.

工程参考数据: OPA2187ID ——对比、设计指导和合规信息。

选型指南

Choose OPA2187ID for low-speed precision measurements where 10 uV input offset, 0.001 uV/C drift, rail-to-rail output, and a 4.5 V to 36 V supply range are sufficient. It is especially useful for bridge sensors, low-side current measurement, buffered references, and diagnostic signals that benefit from two amplifiers in one 8-pin SOIC. Select OPA2188ID when a lower-offset family rating is needed, and OPA2189ID when its precision and dynamic characteristics better match the application. Use OPA2187IDR when the assembly requires the reel-packed ordering form; its electrical specifications remain identical. Before substitution, verify the complete pinout, common-mode range, input bias, noise, gain-bandwidth product, output drive, supply current, stability, and operating-temperature requirements in the manufacturer datasheet.

与替代料对比

参数 本产品 OPA2188ID OPA2189ID OPA2187IDR
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 8-pin SOIC 8-pin SOIC 8-pin SOIC 8-pin SOIC
Amplifier Configuration Dual Dual Dual Dual
Architecture Zero-drift CMOS Zero-drift CMOS Zero-drift CMOS Zero-drift CMOS
Supply Voltage Range 4.5 V to 36 V 4.5 V to 36 V 4.5 V to 36 V 4.5 V to 36 V
Output Swing Rail-to-rail output Rail-to-rail output Rail-to-rail output Rail-to-rail output
Gain Stability Unity-gain stable Unity-gain stable Unity-gain stable Unity-gain stable
Operating Temperature Range -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C

关键差异点

  • Lower offset voltage than typical general-purpose precision amplifiers (对比 OPA2188ID)
  • Very low temperature-dependent offset movement (对比 OPA2189ID)
  • Identical electrical device in the required reel format (对比 OPA2187IDR)
  • Wide supply range with rail-to-rail output (对比 OPA2188ID)

设计说明

Route the OPA2187ID inputs as short, guarded traces directly from the sensor or resistor network. Keep switching-regulator nodes, high-current inductors, and digital clock lines away from the amplifier inputs. Where the source impedance is high, minimize leakage from board contamination and protection diodes because input bias current interacting with source resistance can create an error comparable to the 10 uV offset rating.

Do not treat the 10 uV offset rating as the complete measurement error. Include gain-setting resistor tolerance and temperature coefficient, sensor or shunt tolerance, reference accuracy, amplifier noise over the selected bandwidth, input bias current, and output-load errors in the error budget. The zero-drift architecture reduces offset movement but does not correct gain drift or sensor calibration error.

Decouple each supply rail close to the SOIC pins with the capacitance recommended by the Texas Instruments datasheet, and provide a clean return path from the device ground. The OPA2187ID accepts a 4.5 V to 36 V supply, but nearby switching converters can inject noise even when the amplifier itself is precise. Maintain separation between power-stage currents and sensitive analog return paths to avoid converting common-mode disturbances into measurement errors.

Select the closed-loop gain and bandwidth with the source impedance in mind. Unity-gain stability makes the OPA2187ID convenient as a voltage follower, but capacitive loading can still influence dynamic behavior. Place any input or output filtering capacitors close to the relevant pins and validate their effect on settling time. For multiplexed sensor systems, check settling after channel switching before interpreting the sampled value.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status must be confirmed from the current Texas Instruments product documentation or declaration for the exact OPA2187ID orderable designation.

数据核验日期: 2026-11-23 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

OPA2187ID datasheet OPA2187ID pinout OPA2187ID datasheet pdf Texas Instruments OPA2187ID OPA2187ID equivalent OPA2187ID replacement OPA2187ID drop-in replacement OPA2187ID vs OPA2188ID OPA2187ID 8-SOIC footprint OPA2187ID precision sensor amplifier OPA2187ID price OPA2187ID stock

相关元器件 & 术语

Texas Instruments OPA2187ID OPA2188ID OPA2189ID OPA2187IDR OPA2187 OPAx187 zero-drift operational amplifier dual operational amplifier precision amplifier analog signal-chain IC CMOS input offset voltage input offset drift rail-to-rail output unity-gain stable MUX-friendly 4.5 V to 36 V 8-pin SOIC surface mount current sensing bridge sensor precision data acquisition industrial instrumentation
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情