TUSB3410IVF - USB to UART Bridge | Texas Instruments
料号: TUSB3410IVF ✓ 量产中TUSB3410IVF 概述
A USB-to-UART bridge is an interface IC that translates between the packet-based Universal Serial Bus and a character-oriented serial peripheral. Positioned within interface ICs, bridge controllers, serial interface devices, and data-conversion semiconductors, the TUSB3410 reduces the need for a host to implement a proprietary serial protocol directly. Its integrated controller manages USB-to-serial command exchange while external circuitry connects to the system-side serial interface.
The TUSB3410IVF combines a 3 V to 3.6 V operating range with integrated ROM and an industrial temperature grade. Its supported UART, I2C, and IrDA connectivity allows one bridge to serve conventional serial equipment or infrared-oriented peripherals. The 32-lead LQFP package provides a conventional surface-mount footprint suitable for automated assembly and compact industrial controller layouts.
The device is built around an 8052-compatible microcontroller core with 10 kB of ROM, as identified in the manufacturer product listing. Firmware or configuration can be loaded by the USB host or through external onboard memory using I2C, according to the device documentation. This architecture makes the bridge useful when peripheral behavior must be adapted through firmware rather than implemented entirely in fixed hardware.
Typical applications include industrial serial adapters, USB-connected control panels, legacy equipment interfaces, infrared data links, configuration ports, and embedded systems requiring a USB uplink from a UART-based peripheral. The industrial temperature specification supports equipment deployed in factory, instrumentation, and communications environments where consumer-temperature components may be unsuitable.
Designers should preserve the exact pin assignments and reference circuitry shown in the manufacturer datasheet, especially for external memory, clock, USB, and serial-interface connections. Power and decoupling should follow the recommended topology, while USB signal routing requires a controlled impedance path and short connection from the controller to the connector.
This product page combines the official device description, package and temperature information, replacement considerations, and design-focused guidance. It highlights the practical trade-offs between the industrial TUSB3410IVF and related TUSB3410 ordering variants while keeping sourcing and technical decisions tied to manufacturer documentation.
直接替换替代料: TUSB3410IVF ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: TUSB3410IVF (相同外形与封装尺寸) ——差异在于 Device Type, Operating Temperature Range.
TUSB3410VF
✅ 直接替换联系询价
查看数据手册 →TUSB3410IVF 规格参数
| Device Type | USB to UART bridge controller |
| Microcontroller Core | 8052 |
| ROM | 10 kB |
| Serial Interfaces | UART, I2C, and IrDA |
| USB Device Class | USB serial port controller |
| 工作电源电压 | 3 V to 3.6 V |
| 工作温度范围 | -40°C to +85°C |
| Temperature Grade | Industrial |
| Package Type | LQFP (VF) |
| Package Pin Count | 32 pins |
| 安装类型 | Surface mount |
| Package Terminal Form | Gull wing |
| Package Shape | Square |
| Configuration Interface | I2C |
| Firmware Loading | USB host or external onboard memory |
TUSB3410IVF square 引脚配置指南
TUSB3410IVF(square 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: TUSB3410IVF.
请参阅 数据手册 以查看完整引脚配置。
典型应用
TUSB3410IVF 适用于 6 应用s: Industrial USB-to-UART Adapter, Legacy Equipment USB Retrofit, IrDA Data-Link Adapter, Instrumentation Control Console, USB Configuration Port, Factory Automation Serial Gateway.
Industrial USB-to-UART Adapter
The TUSB3410IVF fits an industrial USB-to-UART adapter because it operates from 3 V to 3.6 V and is rated from -40°C to +85°C. Its integrated 8052 core and 10 kB ROM manage USB-to-serial command handling, while the UART interface connects to legacy equipment. The 32-pin LQFP package supports compact surface-mount construction, but USB differential routing, connector placement, and firmware loading must follow the manufacturer’s reference implementation.
推荐
Legacy Equipment USB Retrofit
The TUSB3410IVF can modernize equipment that originally communicates through a UART or IrDA peripheral by presenting that serial function to a modern USB host. Its 8052 controller core and I2C configuration path make the bridge adaptable to firmware-based peripheral identification and control. For long cable runs or legacy logic levels, add the appropriate line transceiver and isolation; the bridge itself handles USB-side enumeration rather than solving every physical-layer requirement.
推荐
IrDA Data-Link Adapter
The TUSB3410IVF is applicable to an IrDA-oriented adapter because IrDA is one of its documented serial interface options alongside UART and I2C. A USB host can use the bridge as the communication path to an infrared peripheral while the integrated controller handles USB command exchange. Actual infrared range and signaling depend on the external IrDA transceiver and optical hardware, so the bridge should be paired with a compatible physical-layer device and reviewed against timing requirements.
推荐
Instrumentation Control Console
The TUSB3410IVF is well suited to a USB-enabled instrumentation console that must connect a host computer to an internal UART-based controller. Its industrial temperature range supports unheated equipment cabinets, while the 8052 core and 10 kB ROM provide a dedicated interface processor rather than placing USB enumeration burden on the main embedded controller. Power, USB routing, and firmware loading should be designed according to the datasheet, with logic-level conversion added when the target instrument uses a different voltage domain.
推荐
USB Configuration Port
The TUSB3410IVF can implement a USB configuration port for an embedded system whose embedded controller is configured through UART, I2C, or IrDA. Firmware may be loaded by the USB host or from external onboard memory through I2C, allowing the bridge to participate in device initialization. Designers should define the enumeration descriptors, bootloader behavior, timeout handling, and recovery path before production use, then validate them on the target USB host and operating-system combination.
推荐
Factory Automation Serial Gateway
The TUSB3410IVF can serve as the USB uplink in a factory automation gateway that connects a host computer to controller boards or service equipment. Its -40°C to +85°C industrial rating covers many unheated enclosure environments, while UART, I2C, and IrDA support allows one bridge design to cover several service-port configurations. For motor-control or noisy factory environments, maintain separation between USB and power paths, use appropriate transceiver protection, and validate electrostatic and conducted-immunity performance at the system level.
推荐
推荐产品汇总
工程参考数据: TUSB3410IVF ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | TUSB3410VF |
|---|---|---|
| Package | LQFP-32 (VF) | LQFP-32 (VF) |
| Brand | Texas Instruments | Texas Instruments |
| Device Function | USB to UART bridge controller | USB serial-to-port controller |
| Operating Supply Voltage | 3 V to 3.6 V | 3 V to 3.6 V |
| Minimum Operating Temperature | -40°C | 0°C |
| Temperature Grade | Industrial | Commercial, 0°C lower limit |
| Microcontroller Core | 8052 | 8052 |
关键差异点
- Broader cold-temperature operating range (对比 TUSB3410VF)
- Explicit industrial ordering option (对比 TUSB3410VF)
- Integrated multi-protocol bridge architecture (对比 TUSB3410VF)
设计说明
Place the TUSB3410IVF close to the USB connector and route the D+ and D+ signals as a matched differential pair. Minimize vias, stubs, and discontinuities, use the geometry specified by the PCB stack-up, and provide the connector-side ESD protection required by the system design. Keep the USB pair away from switching-power nodes and high-current motor traces.
Operate the bridge only within its specified 3 V to 3.6 V supply range. Place the recommended input and bypass capacitors adjacent to the appropriate supply and ground pins, and check startup sequencing if the bridge shares a rail with external memory or a microcontroller. Confirm that USB signaling levels, I2C pull-ups, and any external memory operate from compatible supply domains.
Use the datasheet pin-configuration diagram as the authority for all 32 LQFP connections, including clock, reset, serial, I2C, and USB signals. Preserve the indicated ground connections and avoid assigning functions by position alone. When external onboard memory is used, keep its address, data, and clock routing compact and validate timing with the actual pull-up and loading configuration.
Do not treat TUSB3410VF as an unconditional replacement for TUSB3410IVF: its documented minimum temperature is 0°C rather than -40°C. Also avoid assuming that USB-to-UART support includes RS-232, RS-485, or IrDA optical signaling. Add the required transceiver, protection, and logic-level conversion, and validate host enumeration, firmware loading, and peripheral communication together.
合规信息
No explicit compliance statement for TUSB3410IVF was identified in the cited product descriptions. The industrial temperature rating does not by itself establish AEC-Q100 qualification.