CD4510BCN - Presettable CMOS BCD Up/Down Counter | onsemi
MPN: CD4510BCN ✓ نشطCD4510BCN نظرة عامة
A presettable BCD up/down counter is a digital logic IC that counts in binary-coded decimal increments or decrements. As a member of the CMOS logic hierarchy, the CD4510BCN sits within counter ICs and digital logic ICs, using complementary MOS technology to support operation from compatible low-voltage supply rails. The BCD structure is useful when a system needs decimal 0-to-9 counting rather than a free-running binary count.
The device has four parallel Q outputs for the current BCD digit, four preset inputs that determine the starting count, an active-low clock input, an up/down direction input, an active-low reset input, and an active-low preset-enable input. Its carry input and carry output permit cascaded decades, allowing counters to cover ranges such as 00 through 99 when two CD4510 devices are combined. The target is identified as an industrial-temperature, through-hole DIP-16 part.
The CD4510BCN is particularly useful in laboratory instruments, test equipment, industrial timers, batch counters, and digital decade displays. Its parallel preset capability allows a measurement system to establish a known count before accumulating events, while the up/down input supports bidirectional sequencing without changing the external counter architecture.
Clocking is the primary design consideration. The clock edge behavior, maximum operating frequency, and permissible input transition timing must be confirmed in the manufacturer datasheet for the selected supply voltage. Because this is a legacy CMOS counter rather than a modern clocked logic device, unused inputs should be tied to defined logic levels, supply bypassing should be placed close to the device, and input sources should avoid excessive ringing.
This product record combines the manufacturer family description, package identification, pin-level connection information, sourcing facts, and practical replacement guidance. It distinguishes verified drop-in candidates from broader functional equivalents so engineers can make a PCB-level replacement decision without confusing package compatibility with electrical equivalence.
بدائل مباشرة لـ CD4510BCN — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع CD4510BCN (نفس عامل الشكل والبصمة) — يختلف في Counter Type, Logic Family, Output Type, Package.
CD4510BCN/A+
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MM14510BCN
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
CD4510BCN الحدود القصوى والخصائص الكهربائية
| Counter Type | Presettable BCD up/down counter |
| Logic Family | CMOS |
| Technology | Complementary MOS enhancement-mode devices |
| Number of Counter Outputs | 4 BCD outputs |
| Number of Preset Inputs | 4 BCD preset inputs |
| Counting Direction | Up or down |
| نوع الخرج | Parallel BCD |
| العلبة | DIP-16, through hole |
| Terminal Count | 16 terminals |
| Package Shape | Rectangular |
| Temperature Grade | Industrial |
| Carry Function | Carry input and carry output |
| AEC-Q100 Qualification | Not applicable |
تكوين أطراف CD4510BCN
| دبوس 1 | CLOCK — Counting clock input |
| دبوس 2 | UP/DOWN — Count direction control input |
| دبوس 3 | RESET — Counter reset input |
| دبوس 4 | PRESET ENABLE — Parallel preset load control input |
| دبوس 5 | Q0 — BCD output, least significant bit |
| دبوس 6 | Q1 — BCD output |
| دبوس 7 | Q2 — BCD output |
| دبوس 8 | Q3 — BCD output, most significant bit |
| دبوس 9 | VSS — Ground reference |
| دبوس 10 | CARRY — Carry output |
| دبوس 11 | PRESET0 — BCD preset input, least significant bit |
| دبوس 12 | PRESET1 — BCD preset input |
| دبوس 13 | PRESET2 — BCD preset input |
| دبوس 14 | PRESET3 — BCD preset input, most significant bit |
| دبوس 15 | VDD — Positive power supply |
| دبوس 16 | CARRY IN — Carry input for cascaded decades |
التطبيقات النموذجية
CD4510BCN مناسب لـ 6 التطبيقs: Industrial Batch and Piece Counter, Digital Decade Display Counter, Laboratory Timing and Event Counter, Bidirectional Position Counter, Digital Timer with Programmable Start Count, Legacy Instrumentation Service and Repair.
Industrial Batch and Piece Counter
The CD4510BCN suits legacy industrial systems that must accumulate items in decimal while retaining a four-bit BCD count for display or control. A sensor conditioned into a valid clock signal can increment the counter on each detected item, while the up/down input permits forward counting, reverse sequencing, or operator-selected operating modes. Its BCD output avoids binary-to-decimal conversion in downstream control logic. The DIP-16 through-hole package also supports repairable industrial instruments and legacy control boards. Before implementation, confirm the counter's operating speed against the sensor's pulse rate and validate the reset and preset-enable sequence against the machine controller.
موصى به
Digital Decade Display Counter
The CD4510BCN provides a natural interface between event counting and decimal display equipment because its four outputs represent one BCD digit. The count can be passed directly to compatible BCD-to-seven-segment decoder and driver circuitry rather than converted from binary. Preset loading allows an instrument to begin at a selected decade, and the carry output supports a second counter for tens. The design should include stable clock conditioning, defined logic states for control inputs, and supply bypassing close to the IC. Confirm the required counter polarity and clock edge against the selected display decoder and system timing requirements.
موصى به
Laboratory Timing and Event Counter
CD4510BCN can be used in laboratory instruments that count timed intervals, repetitive events, or system cycles and require a readable decimal result. A stable oscillator or trigger source drives the clock input, while the counter state can be observed, preset, or reset by the instrument control logic. The BCD carry output is useful for extending the measurable range or signaling an end point. Because the CD4510BCN is a legacy CMOS counter, validate propagation delay, maximum clock frequency, and supply tolerance at the intended clock rate. Use a Schmitt-conditioned clock source if the source has slow edges or significant noise.
موصى به
Bidirectional Position Counter
The CD4510BCN is appropriate for simple position or motion-counting mechanisms where the counter must increment for one direction and decrement for the reverse. A direction-controlled clock source can present pulses to the counter, while the BCD outputs report the current position in decimal. The preset inputs support a homing operation in which the mechanism is initialized to a known coordinate before incremental counting resumes. Care is required to prevent reverse-direction chatter from creating erroneous counts. Debounce mechanical limit switches and condition encoder or switch outputs before they reach the clock or direction inputs.
موصى به
Digital Timer with Programmable Start Count
A CD4510BCN can establish a programmable count-down origin for timer, cycle-control, or pulse-batch systems. The preset inputs load the starting value, after which the direction input selects decrement operation and the carry output identifies the terminal count. This allows a controller to compare a counter state against a process limit or initiate an action after a predetermined number of events. The implementation should define all control inputs during reset and power-up, use clean reset release timing, and avoid asynchronous control changes near a clock edge. Confirm whether the intended timing sequence requires preset on the same edge as reset release or during a separate control interval.
موصى به
Legacy Instrumentation Service and Repair
The through-hole DIP-16 CD4510BCN is particularly useful in maintenance of older counters, decade-counters, and digital measurement instruments where the original footprint is already defined. Its four BCD outputs, preset inputs, and carry facilities reproduce the behavior expected by many TTL-era logic boards while operating from CMOS-compatible supply levels. When repairing such equipment, compare the pin functions, supply voltage, reset polarity, and clock edge of the installed device with the replacement documentation. Existing PCB layout and connector spacing make DIP-16 more convenient than introducing a surface-mount equivalent during a low-volume repair.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ CD4510BCN — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | CD4510BCN/A+ | MM14510BCN |
|---|---|---|---|
| Brand | onsemi | onsemi | onsemi |
| Package | DIP-16 through hole | DIP-16 through hole | DIP-16 through hole |
| Special Ordering Code | CD4510BCN | CD4510BCN/A+ revision suffix | MM14510BCN designation |
أبرز الفروقات
- Direct BCD decade counting avoids binary-to-decimal conversion (مقابلSN74LS90)
- Bidirectional operation in a single counter (مقابلSN74LS93)
- Through-hole DIP-16 simplifies legacy PCB replacement (مقابلCD4510BCN/A+)
ملاحظات التصميم
Do not treat the CD4510 family name as proof that every CD4510 ordering code is electrically identical. The target is a 16-pin DIP implementation, while the replacement candidates carry revision or manufacturer-series suffixes. Before fitting CD4510BCN/A+ or MM14510BCN, compare pin names, active levels, supply limits, propagation delays, maximum clock frequency, and output drive against the original design. This is particularly important when the counter sits near a legacy TTL bus or communicates with a higher-frequency controller.
Place the IC on the side of the PCB that keeps the clock and control traces short, and provide a direct ground return for the device. Keep the supply bypass capacitor close to the VDD and VSS leads, route clock traces away from switching-node and mains-related circuitry, and maintain adequate spacing between adjacent clock and data routes. A through-hole DIP design also benefits from mechanical stability, but lead strain during servicing can crack through-hole joints and create intermittent clock faults.
The counter will interpret clock transitions as count events, so every unwanted transition becomes a measurement error. Use a Schmitt-trigger conditioner when the source has slow or noisy edges, debounce mechanical contacts before routing them to CLOCK, and avoid floating control inputs. Reset and preset-enable signals should also have defined transition states. Confirm setup and hold requirements in the manufacturer datasheet because the valid timing window can change with supply voltage.
معلومات الامتثال
The exact CD4510BCN ordering code is associated with onsemi in the distributor result, while related CD4510 documentation is published by Texas Instruments. Exact environmental and material compliance declarations should be obtained for the selected source and package code.