LT1013AIP - Dual Precision Op Amp, 4V-44V, DIP-8 | TI
MPN: LT1013AIP ✓ نشطLT1013AIP نظرة عامة
A precision operational amplifier is a voltage-feedback amplifier designed to amplify small differential signals while minimizing offset voltage, input bias current, noise, and drift. The LT1013 belongs to the operational-amplifier hierarchy within analog signal-chain ICs, combining a high-impedance differential input stage with a low-distortion output stage. Its broad supply range makes it suitable for both low-voltage instrumentation and higher-voltage industrial signal chains.
The LT1013 family combines high gain with low supply current, low noise, and a low offset-voltage temperature coefficient. Manufacturer documentation identifies the family as a precision dual amplifier with performance suited to battery-powered precision instrumentation, strain-gauge signal conditioning, thermocouple amplification, instrumentation amplifiers, and 4 mA to 20 mA current-loop transmitters. The wide operating supply supports both single 5 V and dual positive and negative supply arrangements.
Each amplifier section operates independently, allowing simultaneous conditioning of two related signals or use as a single amplifier with the other section acting as a buffer. The industrial-grade through-hole package favors laboratory instruments, legacy industrial controllers, test equipment, and maintenance-friendly designs where socketed or hand-inserted assembly is useful. The 8-pin PDIP footprint also simplifies repair and retrofit work compared with fine-pitch surface-mount packages.
Typical applications include precision bridge and strain-gauge front ends, low-level sensor instrumentation, thermocouple and RTD signal conditioning, active filters, threshold detection, and buffered 4 mA to 20 mA current-loop outputs. Because the operating supply extends to 44 V, the amplifier can also support higher-voltage industrial interfaces when the surrounding circuit and protection network are properly rated.
When designing a new PCB, follow the manufacturer pin-description table for every connection and preserve the standard dual-op-amplifier footprint. Place input, feedback, and compensation components close to the relevant amplifier pins, and check the selected resistor and capacitor values against the stability requirements described in the LT1013 manufacturer datasheet.
This page organizes the LT1013AIP supply, packaging, pinout, drop-in alternatives, application fit, and design considerations into one engineering-focused reference. It also compares the exact MPN with legacy precision and general-purpose dual-op-amplifier alternatives so engineers can identify the closest replacement without assuming electrical equivalence.
بدائل مباشرة لـ LT1013AIP — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع LT1013AIP (نفس عامل الشكل والبصمة) — يختلف في Mounting Type, Amplifier Type, Number of Channels, Package.
LT1013IP
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←LT1013CP
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←LM158P
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MC1458P
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←OP221
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
LT1013AIP الحدود القصوى والخصائص الكهربائية
| Amplifier Type | Dual precision operational amplifier |
| Number of Channels | 2 channels |
| Supply Voltage Range | 4 V to 44 V |
| Single-Supply Operation | 5 V typical application |
| Dual-Supply Operation | +/-15 V typical application |
| Voltage Noise Density | 7.2 nV/sqrt(Hz) for the compared device family upgrade |
| Operating Temperature Grade | Industrial grade |
| Package Type | 8-pin PDIP |
| Package Code | DIP |
| Package Shape | Rectangular |
| Terminal Count | 8 |
| نوع التركيب | Through-hole |
| RoHS Compliance | unknown |
| REACH Compliance | unknown |
تكوين أطراف LT1013AIP
| دبوس 1 | OUT A — Amplifier A output |
| دبوس 2 | IN A- — Inverting input of amplifier A |
| دبوس 3 | IN A+ — Non-inverting input of amplifier A |
| دبوس 4 | V- — Negative supply connection |
| دبوس 5 | IN B+ — Non-inverting input of amplifier B |
| دبوس 6 | IN B- — Inverting input of amplifier B |
| دبوس 7 | OUT B — Amplifier B output |
| دبوس 8 | V+ — Positive supply connection |
التطبيقات النموذجية
LT1013AIP مناسب لـ 6 التطبيقs: Strain-Gauge Bridge Signal Conditioning, Thermocouple Instrumentation, 4 mA to 20 mA Current-Loop Transmitter, Precision Active Filtering, Battery-Powered Precision Instruments, Legacy Test and Measurement Equipment.
Strain-Gauge Bridge Signal Conditioning
The LT1013AIP fits low-level strain-gauge front ends because its precision architecture combines high gain with low noise and a low offset-voltage temperature coefficient. Place the amplifier close to the bridge sensor to limit pickup of interference before the millivolt-level differential signal is amplified. The 4 V to 44 V supply range supports both portable measurement instruments and industrial monitoring equipment, while the 8-pin PDIP package is convenient for laboratory and maintenance-oriented assemblies. Resistor networks and compensation capacitors should follow the application circuits in the LT1013 manufacturer datasheet to preserve bandwidth and stability.
موصى به
Thermocouple Instrumentation
A thermocouple produces a small differential voltage that requires stable, low-offset amplification. The LT1013AIP provides two precision amplifier sections for conditioning or differentially amplifying related low-level signals, with the 4 V to 44 V range allowing operation from compact battery-powered instruments to higher-voltage industrial panels. Place input protection, cold-junction compensation components, and feedback networks close to the relevant pins to minimize thermal gradients and noise pickup. Because thermocouple errors are often in the microvolt range, verify offset voltage, drift, bias current, and common-mode limits against the required measurement accuracy.
موصى به
4 mA to 20 mA Current-Loop Transmitter
The LT1013 family is identified for 4 mA to 20 mA current-loop transmitters, making the LT1013AIP appropriate for precision conversion of sensor voltages into standard industrial loop current. The amplifier can condition the input while the second section buffers a reference or assists with output drive. Its broad 4 V to 44 V supply range supports protected industrial loops, although the complete circuit still requires current limiting and surge protection. Validate output swing, loop compliance voltage, and stability over the full supply range before connecting the transmitter to field wiring.
موصى به
Precision Active Filtering
The LT1013AIP is suitable for low-frequency active filters where offset drift and noise can obscure weak sensor signals. Its dual precision architecture permits two amplifier sections to implement a second-order filter, instrumentation stage, or buffered active network without changing the 8-pin through-hole footprint. The 4 V minimum supply supports compact battery-operated analyzers, while the 44 V maximum rating offers flexibility in higher-voltage laboratory systems. Select resistor and capacitor values from the manufacturer application guidance, check each amplifier's stability with the chosen gain, and keep feedback components compact to minimize parasitic coupling.
موصى به
Battery-Powered Precision Instruments
Low supply current makes the LT1013AIP suitable for battery-powered precision instruments where every milliamp affects operating time. The dual amplifier can support a complete low-level measurement channel, including a gain stage and output buffer, in one package. Its 4 V to 44 V supply range accommodates single 5 V portable systems as well as higher-voltage laboratory instruments. Designers should minimize board area to reduce leakage paths, use high-impedance guarding techniques for sensitive inputs, and confirm the total system current from both amplifier sections under the worst-case load.
موصى به
Legacy Test and Measurement Equipment
The 8-pin PDIP LT1013AIP is especially useful when repairing or extending older laboratory and industrial test equipment that uses through-hole analog circuits. The standard dual-amplifier arrangement simplifies mechanical replacement on existing boards, and the wide supply range covers both 5 V and higher-voltage analog sections. A careful replacement still requires checking pin functions, supply polarity, offset limits, compensation values, and temperature grade. Use the manufacturer datasheet when converting a surface-mount design or when the original assembly includes trim potentiometers and external compensation networks.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ LT1013AIP — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | LT1013IP | LT1013CP | LM158P | MC1458P | OP221 |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | onsemi | Analog Devices |
| Package | PDIP-8 | PDIP-8 - same | PDIP-8 - same | PDIP-8 - same | PDIP-8 - same | PDIP-8 - same |
| Amplifier Configuration | Dual precision operational amplifier | Dual precision operational amplifier | Dual precision operational amplifier | Dual precision operational amplifier | Dual operational amplifier | Dual precision operational amplifier |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
| Primary Application Focus | Precision instrumentation and signal conditioning | Precision instrumentation and signal conditioning | Precision instrumentation and signal conditioning | Legacy precision signal conditioning | Legacy general-purpose amplification | Legacy precision signal conditioning |
أبرز الفروقات
- Combines a 44 V maximum supply with low-power precision amplification (مقابلMC1458P)
- Upgraded noise performance within the legacy dual-op-amplifier ecosystem (مقابلOP221)
- Industrial temperature grade in a serviceable through-hole package (مقابلLT1013IP)
- Two precision amplifier sections in the standard 8-pin configuration (مقابلLM158P)
ملاحظات التصميم
Keep the feedback network, input resistors, and compensation capacitors close to their associated LT1013 pins. Sensitive bridge or thermocouple inputs should have a short path from the connector to the amplifier, with guard techniques applied where leakage from PCB contamination could affect a high-impedance source. Place the bypass capacitor adjacent to the positive supply pin and connect the negative supply return directly into the ground plane. Because the LT1013AIP uses a legacy 8-pin PDIP footprint, pay particular attention to solder bridging and contamination between the closely spaced input leads.
Do not treat every 8-pin dual operational amplifier as an electrical substitute for the LT1013AIP. A mechanically identical footprint can still differ in offset voltage, drift, bias current, noise, bandwidth, stability, supply current, and output-swing behavior. The most common retrofit error is replacing a precision instrumentation amplifier with a general-purpose unit whose low-frequency error is too large for the measurement specification. Compare the candidate against the complete LT1013 operating envelope and confirm the temperature grade. Also avoid applying the 44 V maximum rating to transient protection; add appropriate clamping and surge protection where the field connection is exposed.
Estimated: supply current depends on the output stage, supply voltage, input common-mode condition, and whether both amplifier sections are active, so obtain the operating-current curve from the LT1013 manufacturer datasheet before sizing a battery or regulator. For battery-powered operation, total current is approximately the sum of both sections plus the external bias and feedback-network current. A practical design should reserve regulator headroom for transient load steps and include a local bypass capacitor at the supply pin. Do not use a nominal-current estimate as the sole basis for a long-term power budget.
When adapting an existing board, verify the LT1013AIP pin-description table and package drawing before assigning tracks, particularly around the two amplifier sections and the supply connections. Keep output routing away from input and reference nodes, particularly in high-gain configurations where capacitive coupling can create oscillation. Use a single low-impedance ground return for both amplifier sections rather than splitting analog and return currents through long board traces. For retrofit work, inspect the existing board for leaked flux and contamination before installing the replacement through-hole device.
معلومات الامتثال