MAX378EPE+ - 8:1 High-Voltage Fault-Protected Multiplexer
MPN: MAX378EPE+ ✓ نشطMAX378EPE+ نظرة عامة
An analog multiplexer is an interface IC that connects one shared signal path to one of several input channels. A 1-of-8 device provides eight selectable inputs, while a fault-protected multiplexer adds internal channel-isolation behavior during abnormal power conditions. The MAX378 belongs to the broader hierarchy of interface ICs, analog switches, multiplexers, and signal-management semiconductors.
Key features include a 1-of-8 configuration, maximum on-resistance of 3.5 kΩ, dual-supply operation from ±4.5 V to ±18 V, maximum on-time of 1 µs, and maximum off-time of 300 ns. The fault-protected architecture uses a series N-channel, P-channel, and N-channel structure. If the power supplies are turned off while input voltages remain present, all multiplexer channels turn off and leakage falls to only a few nanoamperes.
The MAX378 family is intended for instrumentation and data-acquisition systems that must select among multiple high-voltage measurement sources. Its single-ended topology differs from the differential MAX379, which uses four differential channels. For systems using programmable gain, a precision amplifier such as the MAX420 can follow the selected multiplexer output and provide gain correction or amplification.
Typical uses include automated test equipment, data-acquisition units, industrial measurement systems, and laboratory instruments. The ±4.5 V to ±18 V supply range allows operation around zero and bipolar signal ranges when dual supplies are available. The 16-pin PDIP format also simplifies prototype construction and through-hole assembly.
Designers should verify the absolute maximum input and supply ratings, derating strategy, fault-current limits, and pin-specific input restrictions in the manufacturer datasheet before applying external voltages. Supply bypassing should be placed close to the device, and unused control inputs should be driven to defined logic levels rather than left floating.
This product page combines the manufacturer family information with a practical comparison of pin-compatible family variants, interface considerations, application guidance, and design notes. These engineering details help shorten component selection while preserving the need to validate absolute maximum ratings in the final system.
بدائل مباشرة لـ MAX378EPE+ — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
MAX378EPE
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MAX378CPE+
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MAX378EPE+ المواصفات
| Product Type | 8-channel, single-ended analog multiplexer |
| Multiplexer Configuration | 1-of-8 |
| Number of Circuits | 1 circuit |
| Maximum On-Resistance | 3.5 kΩ |
| Minimum Dual Supply Voltage | ±4.5 V |
| Maximum Dual Supply Voltage | ±18 V |
| Maximum On-Time | 1 µs |
| Maximum Off-Time | 300 ns |
| Minimum Operating Temperature | -40 °C |
| Maximum Operating Temperature | +85 °C |
| Power-Off Fault Leakage | A few nA |
| Internal Channel Structure | Series N-channel/P-channel/N-channel structure |
| العلبة | 16-pin PDIP |
| نوع التركيب | Through-hole |
| Product Lifecycle | PRODUCTION |
دليل تكوين أطراف MAX378EPE+ 16-pin pdip
تكوين الأطراف لـ MAX378EPE+ (حزمة 16-pin pdip). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ MAX378EPE+.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
MAX378EPE+ مناسب لـ 6 التطبيقs: Automated High-Voltage Test Systems, Data-Acquisition Systems, Industrial Signal Conditioning, Laboratory Instrumentation, Battery and Power-System Monitoring, Programmable Signal Routing.
Automated High-Voltage Test Systems
The MAX378EPE+ fits automated test equipment that routes one of eight high-voltage measurement sources into a common signal chain. Its 1-of-8 configuration reduces the number of separate analog input paths, while the 3.5 kΩ maximum on-resistance provides a defined basis for calculating source loading and measurement sensitivity. The 1 µs maximum on-time and 300 ns maximum off-time support controlled channel selection during sequential tests. Fault protection is especially useful when an external source can remain energized while the instrument supply changes. Use the exact pin description and address-control truth table from the manufacturer datasheet when assigning the eight channels and digital selection inputs.
موصى به
Data-Acquisition Systems
The MAX378EPE+ can select up to eight single-ended inputs in a multi-channel data-acquisition system. A common architecture places the multiplexer in front of a precision amplifier and analog-to-converter, reducing the number of high-performance conversion channels required. The 3.5 kΩ maximum on-resistance must be included in the source-impedance and gain-error budget, especially for high-impedance sensors. The device's ±4.5 V to ±18 V dual-supply range supports systems that measure bipolar signals. Its fault-protected behavior helps isolate the downstream chain when an input remains driven after the acquisition board loses power, subject to the published absolute maximum ratings.
موصى به
Industrial Signal Conditioning
The MAX378EPE+ is appropriate for industrial signal-conditioning equipment that must select among several externally wired voltage sources. The 8:1 single-ended architecture can consolidate sensor inputs, reference channels, or diagnostic points into one downstream measurement path. Operation from -40 °C to +85 °C supports temperature-controlled industrial enclosures, while the ±4.5 V to ±18 V supply range accommodates bipolar biasing. Because the maximum on-resistance is 3.5 kΩ, input buffering requirements depend on sensor impedance and measurement accuracy. Protective grounding, current limiting, and overvoltage protection remain external to the multiplexer and should be sized independently for each industrial input.
موصى به
Laboratory Instrumentation
The MAX378EPE+ can front-end a laboratory instrument that compares multiple high-voltage test points or programmable sources. A single multiplexed path simplifies the analog routing structure, while a precision amplifier can provide the required gain after selection. The 16-pin PDIP package is convenient for through-hole laboratory prototypes and removable instrument boards. Switching performance includes a 1 µs maximum on-time and 300 ns maximum off-time, allowing the instrument controller to sequence channels with settling time handled in software. Designers should account for the 3.5 kΩ maximum on-resistance when calculating attenuation and noise, and should use the manufacturer's timing and charge-injection specifications when setting acquisition windows.
موصى به
Battery and Power-System Monitoring
The MAX378EPE+ is suitable for multi-rail or battery-test equipment that must measure several voltage points through a shared analog channel. The single-ended 1-of-8 topology is useful for pack taps, balancing points, charger outputs, and diagnostic rails. The ±4.5 V to ±18 V dual-supply capability supports bipolar test arrangements, while fault protection reduces unintended coupling when a monitored node remains energized during a power transition. The 3.5 kΩ maximum on-resistance can add loading to high-impedance dividers, so divider values should be selected accordingly. Thermal design must ensure that external fault current and power-dissipation conditions remain within the device's absolute maximum ratings.
موصى به
Programmable Signal Routing
The MAX378EPE+ enables programmable routing among eight external signal sources when a system requires one measurement or processing chain to be reused across multiple inputs. Digital address inputs can direct the common terminal to the selected channel, while the enable control determines whether the path is active. The 1 µs maximum on-time and 300 ns maximum off-time are useful when sequencing tests quickly, although the controller should include settling time for the 3.5 kΩ maximum on-resistance and downstream capacitance. For zero-centered or bipolar signals, the ±4.5 V to ±18 V supply range supplies the required operating headroom. Confirm logic thresholds, address mapping, and all absolute maximum input conditions in the manufacturer datasheet.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ MAX378EPE+ — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | MAX378EPE | MAX378CPE+ |
|---|---|---|---|
| Package | 16-PDIP | 16-PDIP | PDIP-16 |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Number of Channels | 8 | 8 | 8 |
| Multiplexer Configuration | 1-of-8, single-ended | 1-of-8, single-ended | 1-of-8, single-ended |
| Maximum On-Resistance | 3.5 kΩ | 3.5 kΩ | 3.5 kΩ |
| Dual Supply Voltage Range | ±4.5 V to ±18 V | ±4.5 V to ±18 V | ±4.5 V to ±18 V |
| Maximum On-Time | 1 µs | 1 µs | 1 µs |
| Maximum Off-Time | 300 ns | 300 ns | 300 ns |
أبرز الفروقات
- Supports cold environments across a -40 °C to +85 °C range (مقابلMAX378CPE+)
- Matches the principal switching specifications of MAX378CPE+ (مقابلMAX378CPE+)
- Retains the 16-PDIP footprint of the MAX378EPE (مقابلMAX378EPE)
ملاحظات التصميم
Use separate bypass capacitors close to the positive and negative supply pins, following the manufacturer datasheet's recommended values and layout. The ±4.5 V to ±18 V dual-supply range does not define a safe input range for every channel, so verify the absolute maximum input voltage independently. During fault testing, ensure that externally applied voltages and prospective fault currents cannot exceed the published limits.
Do not treat the 3.5 kΩ maximum on-resistance as a constant value across temperature, voltage, and channel conditions. Include it in the complete source-impedance and gain-error calculation, especially with high-impedance sensors. Also avoid leaving address or enable inputs floating; drive every control input to a defined logic level so the selected channel remains deterministic during power-up and test transitions.
Allow sufficient settling time after changing channels because the published 1 µs on-time and 300 ns off-time describe switching behavior rather than complete measurement accuracy. Long traces, connector capacitance, leakage, and high source impedance can extend settling. For precision measurements, use a short common path, maintain a consistent reference return, and place the precision amplifier close enough to minimize additional parasitic capacitance.
معلومات الامتثال
The manufacturer identifies MAX378 as a production product, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals status is stated for this ordering code. AEC-Q100 is not applicable to this general-purpose interface IC.