MC1488MEL - Quad EIA-232D Driver | onsemi
MPN: MC1488MEL ✓ نشطMC1488MEL نظرة عامة
A line driver is an interface IC that converts low-voltage logic signals into differential, bipolar RS-232-style voltage levels for transmission over a serial communication link. In the broader hierarchy, the MC1488MEL belongs to the RS-232 driver and receiver family, within interface ICs and data-communication semiconductors. Its four channels allow one package to support multiple unidirectional serial lines, reducing board area compared with separate single-channel drivers.
The principal feature of the MC1488MEL is its quad EIA-232D line-driver architecture. The manufacturer describes the MC1488 as a monolithic quad line driver with current-limited outputs and an operating supply arrangement of approximately ±15 V. This architecture is useful when a system needs to translate TTL or CMOS-side control signals into the voltage levels expected by an RS-232 interface, particularly where multiple unidirectional channels are required.
The MC1488MEL is specified for commercial-extended temperature-grade applications. Its 14-terminal surface-mount construction is intended for automated PCB assembly and compact equipment designs. The package is identified as SOEIAJ-14 rather than a generic 14-pin SOIC designation, so engineers should use the manufacturer pin configuration and land pattern associated with that specific package when laying out a replacement board.
Typical uses include industrial control equipment, data-terminal interfaces, RS-232 communication ports, peripheral connections, and legacy serial-control systems. Because it is a driver rather than a combined transceiver, the application must provide a separate receiver when a complete bidirectional RS-232 port is required. Review signal polarity, supply sequencing, cable routing, and grounding before using the device in a new design.
For power planning, use the datasheet’s absolute-maximum and recommended operating conditions rather than assuming that ±15 V is the only acceptable implementation. The device’s output stage is intended for current-limited RS-232 driver operation, but the PCB still needs appropriate supply decoupling and controlled return paths. This page focuses on the MC1488MEL’s function, package, interface role, and replacement considerations.
بدائل مباشرة لـ MC1488MEL — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
الطرازات في هذه السلسلة
طرازات من نفس السلسلة متوافقة تمامًا مع MC1488MEL (نفس عامل الشكل والبصمة).
MC1488MELG
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منها📋 بديل مرجعي (غير موجود في الكتالوج)
SN75C188D
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
DS14C88M/NOPB
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MC1488M
✅ بديل مباشر ⚠️ مواصفات غير مُتحقق منهاتواصل لمعرفة السعر
عرض ورقة البيانات ←MC1488MEL المواصفات
| Product Type | Quad line driver |
| Driver Configuration | 4 independent driver channels |
| Interface Standard | EIA-232D |
| جهد التغذية | ±15 V |
| العلبة | SOEIAJ-14, 14-pin surface-mount package |
| Package Width | 5.30 mm |
| نوع التركيب | Surface mount |
| Number of Terminals | 14 |
| Temperature Grade | Commercial extended |
| Output Current | ±10 mA typical |
| Data Terminal Equipment Interface | RS-232 / EIA-232D |
| Number of Drivers | 4 |
| Termination Style | Gull wing |
| Package Shape | Rectangular |
دليل تكوين أطراف MC1488MEL rectangular
تكوين الأطراف لـ MC1488MEL (حزمة rectangular). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.
لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ MC1488MEL.
راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.
التطبيقات النموذجية
MC1488MEL مناسب لـ 6 التطبيقs: Industrial RS-232 Control Ports, Data-Terminal Equipment Interfaces, Peripheral Serial Links, Legacy Communication Equipment, Instrumentation and Test Systems, Multi-Channel Point-to-Point Communication.
Industrial RS-232 Control Ports
The MC1488MEL fits industrial equipment that must transmit several unidirectional RS-232 control or status signals from a controller to a peripheral. Its four independent driver channels implement the EIA-232D transmitter side while operating from approximately ±15 V supplies. This integration reduces the number of separate single-channel driver packages and preserves a clear separation between logic-side signals and cable-side outputs. The design must still provide a receiver when the controller needs return data. Confirm logic thresholds, cable protection requirements, and grounding in the final interface circuit.
موصى به
Data-Terminal Equipment Interfaces
The MC1488MEL is suitable for legacy data-terminal equipment that requires multiple RS-232 transmit paths from one logic interface. The quad arrangement allows four independent outputs to be routed toward a DCE or peripheral connection while the monolithic EIA-232D driver handles the required voltage conversion. Because the MC1488MEL provides no receive function, the system needs separate receiver channels for incoming data. Review the manufacturer’s typical application circuit for supply bypassing and output connections, and verify that every external cable reaches the board through suitable protection.
موصى به
Peripheral Serial Links
The MC1488MEL can provide the transmitter circuitry for a multi-channel peripheral serial link when the host uses TTL or CMOS control signals and the peripheral expects RS-232 levels. Four channels allow command, status, handshake, and auxiliary signals to share a common driver IC when they are all unidirectional. The key design consideration is avoiding contention: outputs must remain associated with the intended transmit direction, and any receive-only signals need a separate receiver. The ±15 V supply architecture and current-limited output stage match the classic EIA-232D driver role.
موصى به
Legacy Communication Equipment
The MC1488MEL is appropriate for maintaining or redesigning legacy EIA-232D communication equipment that requires four dedicated transmit outputs. Its monolithic quad-driver construction simplifies channel allocation and reduces package count compared with four separate single-channel drivers. The device is specified with ±15 V supply operation, so the surrounding system must generate or distribute the required bipolar rails and maintain a low-impedance ground reference. Engineers should also account for connector-level transient protection and ensure that the chosen receiver has compatible thresholds for the incoming data path.
موصى به
Instrumentation and Test Systems
The MC1488MEL can support unidirectional command channels in instrumentation and test systems that use RS-232 as an external control interface. Four driver channels provide a practical way to route separate commands or status outputs without multiplying the number of line-driver packages. The device does not replace the receiver front end or provide modem signaling, so a complete instrument interface must include appropriate receive circuitry. Validate the system’s ±15 V rail tolerance, ground-noise behavior, and connector protection before connecting the board to external equipment.
موصى به
Multi-Channel Point-to-Point Communication
The MC1488MEL suits point-to-point systems that need several dedicated EIA-232D transmit paths between a controller and remote equipment. Its four independent channels can carry separate commands, acknowledgements, or supervisory outputs when the link architecture assigns each signal a fixed direction. The package reduces board area and simplifies supply distribution compared with four discrete single-channel drivers. Application engineering must verify the receiver arrangement, signal polarity, cable length, and protection network, since the MC1488MEL supplies only the transmit function and does not accept data from the remote endpoint.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ MC1488MEL — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
ملاحظات التصميم
Use the MC1488MEL datasheet’s ±15 V operating specification as the basis for the bipolar supply design. Place bypass capacitors close to the device’s supply pins according to the manufacturer’s typical application circuit and keep the ground return path short. External cables can carry transients, so assess whether additional series impedance, clamps, or connector-level protection are required without disturbing the EIA-232D output-current behavior.
Lay out the MC1488MEL strictly from the SOEIAJ-14 pin configuration and land pattern, not from a generic 14-pin package drawing. Confirm which terminals are inputs, outputs, supply rails, and ground before routing PCB tracks. Keep the driver outputs away from sensitive logic and maintain a continuous ground reference between the interface board and connector shield where the system architecture requires it.
Do not treat the MC1488MEL as a bidirectional transceiver: it is a driver-only device. A complete RS-232 port also requires one or more receivers, and every signal direction must be defined to prevent output contention. When evaluating MC1488-family replacements, compare terminal count, package width, logic thresholds, supply range, output-current limits, and temperature grade rather than relying only on the device description.
معلومات الامتثال
The MC1488MEL is a commercial-extended RS-232 line-driver IC and is not an automotive-qualified AEC-Q100 product. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not stated in the verified sources and remain unknown.