Skyworks Solutions

SI3069-A-FT - 25A Thermal Circuit Breaker | Skyworks

MPN: SI3069-A-FT ✗ انتهى عمره الإنتاجي
250 VAC Vdss 25 A Id
الحد الأدنى للطلب: 1 |

SI3069-A-FT نظرة عامة

The Skyworks Solutions Inc. SI3069-A-FT is a 1-pole thermal circuit-breaker interface IC rated for 25 A and operating at up to 250 VAC or 50 VDC in a 2-pin package. Its principal function is to interrupt a protected circuit when sustained current exceeds the thermal trip threshold, providing a compact protection element for power-distribution and industrial-control equipment.

A thermal circuit breaker is a resettable circuit-protection device. Unlike a single-use fuse, it mechanically opens its contacts when heat generated by overcurrent reaches the trip point. Within the broader hierarchy of circuit protection, the SI3069-A-FT combines a thermal sensing element and interrupting contact in a small package suitable for PCB-level integration.

The listed electrical ratings establish a 25 A current class with a 1-pole contact arrangement. Its dual 250 VAC and 50 VDC rating allows the same device family to address both alternating-current and direct-current systems, provided each application stays within the manufacturer’s specified mounting, calibration, and environmental limits. The two-terminal package also supports straightforward routing between the protected load and its supply node.

Because this device is thermal, its trip behavior depends on current magnitude, duration, ambient temperature, and the thermal path through the PCB. Sustained overload can therefore create a longer trip delay than a short-duration current surge. Designers should preserve the manufacturer’s recommended copper and solder geometry rather than treating the package as an unrestricted high-current connector.

Typical uses include overload protection for industrial control modules, auxiliary power branches in test and measurement equipment, and DC or AC input branches where a compact, manually resettable protective element is appropriate. Each branch must be selected against the exact voltage, current, and thermal environment required by the equipment rather than on the 25 A headline rating alone.

The primary layout consideration is current capacity: high-resistance solder joints or narrow copper traces can add unwanted temperature rise and contribute to nuisance tripping. Place the device in the uninterrupted protected-current path, use the prescribed land pattern, and keep high-current copper planes compact while maintaining adequate conductor width. Confirm the final arrangement with the manufacturer datasheet.

This page combines the identified ratings and lifecycle information with package-aware comparison fields, sourcing guidance, and practical protection-layout notes. Because a current schematic footprint and official pin table were not available, engineers should verify the land pattern and terminal numbering against the manufacturer documentation before fabrication.

بدائل مباشرة لـ SI3069-A-FT — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

الطرازات في هذه السلسلة

طرازات من نفس السلسلة متوافقة تمامًا مع SI3069-A-FT (نفس عامل الشكل والبصمة) — يختلف في Mounting Type, Product Type.

Silicon Laboratories
Mounting Type: Surface mount
Product Type: Programmable global line-side direct access arrangement (DAA) interface IC
قارن مع SI3069-A-FT →

لا تتوفر بدائل متوافقة تمامًا لهذا المنتج.

اطلب بدائل

SI3069-A-FT المواصفات

Product Type Thermal circuit breaker interface IC
Rated Current 25 A
Number of Poles 1 pole
Maximum AC Voltage 250 VAC
Maximum DC Voltage 50 VDC
عدد الأطراف 2 pins
نوع التركيب Standard
Trip Mechanism Thermal

دليل تكوين أطراف SI3069-A-FT standard

تكوين الأطراف لـ SI3069-A-FT (حزمة standard). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.

مخطط توزيع أطراف حزمة standard لـ SI3069-A-FT

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ SI3069-A-FT.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

SI3069-A-FT مناسب لـ 6 التطبيقs: Industrial Control Branch Protection, DC Auxiliary Power Protection, Test and Measurement Input Protection, Power-Distribution Module Protection, Building Control and Automation Equipment, Embedded Equipment Replacement.

🏭

Industrial Control Branch Protection

The SI3069-A-FT fits an industrial control branch that requires a compact 1-pole thermal interrupter rated to 25 A and up to 250 VAC or 50 VDC. It can be placed in the input path of a controller, relay panel, or auxiliary power distribution board to interrupt sustained overloads. The principal design consideration is thermal repeatability: PCB copper, solder joints, enclosure temperature, and nearby heat sources all affect the trip point. Confirm that the 25 A rating represents the intended calibration and that the device’s verified operating-temperature range covers the cabinet interior. Because this MPN is obsolete, use it primarily for continuity of an existing qualified assembly rather than as the sole basis for a new production design.

⚡

DC Auxiliary Power Protection

The SI3069-A-FT is applicable to a 50 VDC auxiliary branch where a 25 A thermal circuit breaker provides overload protection for motors, heaters, or high-current control loads. Its 1-pole arrangement keeps the protection path compact, but the PCB layout still needs low-resistance connections so that unintended copper heating does not create an early trip. A fuse may appear electrically similar, yet its one-time behavior and current-time characteristic differ from a thermal breaker. Validate the breaker’s hold and trip currents against the minimum normal operating current and worst-case startup inrush. For new platforms, select a currently supported device with a documented 50 VDC and 25 A DC breaking rating rather than assuming the AC rating applies identically to DC arcs.

🖥️

Test and Measurement Input Protection

The SI3069-A-FT can serve as an overload element in a test or measurement module that temporarily energizes a load through a protected branch. Its identified 25 A rating is appropriate only when the source, wiring, and load can sustain that level without creating excessive voltage drop or PCB heating. For automated test equipment, the protection device should be positioned where a failed DUT cannot repeatedly impose an overload on sensitive upstream circuitry. Because the SI3069-A-FT is obsolete, any redesigned instrument should use an active replacement with verified interrupt rating, trip curve, and operating temperature. Do not reuse the existing footprint unless the candidate device’s terminal arrangement, mounting method, and thermal calibration have been confirmed from authoritative documentation.

🔧

Power-Distribution Module Protection

The SI3069-A-FT is suited to a compact power-distribution module needing one protected branch for loads up to the device’s 25 A current class. The two-pin package can simplify board routing, but correct current sharing depends on wide, short copper paths and mechanically sound solder joints. Place the breaker where it can interrupt the branch without adding an unnecessary series resistance to precision analog or communication circuitry. Review the manufacturer’s thermal mounting guidance and use the prescribed copper geometry to maintain consistent trip calibration across production tolerances. Since the SI3069-A-FT is obsolete, preserve it for repair of a proven assembly and evaluate a currently supported equivalent for new production only after checking voltage, interruption capacity, trip timing, and terminal compatibility.

🏠

Building Control and Automation Equipment

The SI3069-A-FT can provide branch overload protection in a building-control unit that includes relays, contactors, or other inductive loads. The 250 VAC rating makes the device relevant to nominal low-voltage AC control circuits, but inductive load energy can create additional arcing and voltage stress at contact closure. Engineers should check the device’s permitted inductive-load category and test it with the actual relay coil, cable length, and suppression network. Thermal trip behavior also depends on ambient temperature inside the enclosure, so the mounting location should avoid hot regulators and power semiconductors. For new building-automation products, prefer a supported circuit protector whose documentation explicitly covers the required AC voltage, load category, ambient range, and reset behavior.

🔧

Embedded Equipment Replacement

The SI3069-A-FT is relevant to maintenance of embedded equipment whose original schematic used this obsolete 1-pole, 25 A thermal breaker. A repair should begin by confirming the exact terminal orientation, package drawing, protected branch, and trip characteristic rather than selecting a device solely by the 25 A marking. Mismatched hold current or trip delay can leave normal startup loads unprotected or cause repeated nuisance shutdowns. Request traceable obsolete stock through the Request a Quote form and inspect the returned device for mechanical damage before installation. For broader product redesigns, maintain the functional protection requirement in the system requirements while selecting a supported part with a verified footprint, interruption rating, thermal calibration, and lifecycle plan.

What is the SI3069-A-FT?
The SI3069-A-FT is a 1-pole thermal circuit breaker rated for 25 A at up to 250 VAC or 50 VDC. It is listed as a two-pin interface-circuit device intended for PCB-level overload protection. According to the manufacturer datasheet description, its thermal mechanism opens the protected path when sustained current produces sufficient heat to initiate a trip.
What voltage and current ratings apply to SI3069-A-FT?
The SI3069-A-FT is rated for a 25 A circuit-breaker current class, 250 VAC maximum voltage, and 50 VDC maximum voltage. These are separate operating limits: the 25 A value must not be treated as a continuous-load allowance for every voltage or ambient condition. Confirm the calibrated current, trip curve, and thermal limits in the manufacturer datasheet before applying the part to a specific branch.
Where can I download the SI3069-A-FT datasheet PDF?
A SI3069-A-FT datasheet PDF is accessible through the linked documentation mirror on this page. The manufacturer’s current official product-page URL was not identified for this obsolete device, so engineers should use the document number and revision printed inside the PDF when checking its origin and revision history. Search for “SI3069-A-FT datasheet PDF” to locate the linked copy and related catalog records.
Where can I find the SI3069-A-FT pinout?
The SI3069-A-FT pinout cannot be published reliably because the complete terminal-name table was not identified, although the component is listed as a two-pin device. Do not infer terminal polarity or orientation from package appearance alone. Obtain the manufacturer pin-description table or land pattern, then verify terminal numbering against the PCB footprint before assembly.
Is the SI3069-A-FT still active?
The SI3069-A-FT is listed as obsolete rather than an active production device. Obsolete status means new designs should not depend on routine future production without a confirmed supply plan. For maintenance and repair work, request current inventory, traceable condition, and lot information through the Request a Quote form on this page before placing an order.
Where can I buy SI3069-A-FT online?
Use the Request a Quote form on this page to request SI3069-A-FT availability and sourcing support. Because the component is obsolete and listings may represent residual inventory, request the manufacturer identity, date code, lot traceability, and exact package suffix. The quote team can then distinguish original stock from newly manufactured or unverified inventory before an order is placed.
What is the price of SI3069-A-FT?
The current unit price is not displayed because no qualifying quantity-break listing was available for this obsolete MPN. Submit SI3069-A-FT through the Request a Quote form on this page for a current response based on quantity, condition, and traceability. Do not use an obsolete catalog-price screen as an indication of present market availability.
What is the lead time for SI3069-A-FT?
Lead time depends on remaining factory stock, condition, lot traceability, and the quantity required. Request the current lead time through the Request a Quote form on this page and state whether the procurement team requires original, traceable devices. For obsolete components, reserve production and inspection time as well as the delivery interval before committing a replacement date.
Is SI3069-A-FT in stock?
Stock status for SI3069-A-FT changes because the device is obsolete and some listings represent residual inventory rather than production stock. Use the Request a Quote form on this page to request a current inventory check. Ask for the quantity available, date code, traceability documents, and whether each lot is original manufacturer stock before approving an order.
What can replace SI3069-A-FT?
A valid replacement must match the two-terminal footprint, 25 A thermal-breaker class, 1-pole arrangement, and applicable 250 VAC or 50 VDC voltage rating. No cross-reference listing confirmed a pin-to-pin replacement for this obsolete MPN. Until a manufacturer or authorized distributor identifies an exact substitute, treat the part as a unique sourcing and design-review item rather than fitting a merely similar breaker.
Is SI3069-A-FT the same as a standard 25 A fuse?
No. The SI3069-A-FT is listed as a thermal circuit breaker rather than a fuse, so its protection behavior, reset mechanism, and installation method may differ even though both devices protect against overcurrent. According to the manufacturer device description, its operation depends on thermal heating from sustained current. Confirm reset and trip characteristics before substituting a fuse into the same board.
When should I choose SI3069-A-FT for a new circuit design?
Choose SI3069-A-FT for a new design only when its exact obsolete-device supply can be secured and the 25 A, 250 VAC, and 50 VDC limits fit the application. For new production, a currently supported breaker with the same footprint, calibration, trip curve, and agency requirements is generally more sustainable. Do not approve a new design solely because the obsolete part’s nominal current rating appears compatible.
Is SI3069-A-FT suitable for industrial circuit protection?
The SI3069-A-FT can be considered for industrial branch protection when the protected current is at or below its 25 A rating and the maximum voltage is no more than 250 VAC or 50 VDC. Industrial qualification may impose additional environmental and surge requirements. Verify the manufacturer’s operating-temperature rating, trip curve, dielectric ratings, and applicable certification before approving it for machinery or control cabinets.
What are the key specifications of SI3069-A-FT that engineers should know?
The key identified specifications are a 25 A rating, 1-pole configuration, 250 VAC maximum voltage, 50 VDC maximum voltage, a two-pin package, and standard mounting. The device operates as a thermal circuit breaker. Its trip delay, hold current, minimum trip current, contact resistance, operating-temperature range, and exact dimensional drawing must be confirmed from the manufacturer datasheet.
How should SI3069-A-FT be mounted to avoid nuisance tripping?
Mount SI3069-A-FT in the continuous protected-current path and follow the manufacturer’s prescribed PCB land pattern and copper geometry. Estimated: thermal resistance in the copper path affects the trip point, so changing trace width, solder-joint area, or nearby heat sources can alter protection behavior. Confirm the current rating and trip curve against the actual PCB layout under worst-case ambient and enclosure conditions.

بيانات مرجعية هندسية لـ SI3069-A-FT — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose the SI3069-A-FT when maintaining an existing assembly that specifically uses this obsolete two-pin, 1-pole thermal breaker and requires its 25 A current class, 250 VAC rating, or 50 VDC rating. It is most appropriate where a resettable thermal interruption mechanism is needed and the exact trip calibration, package, and thermal mounting have already been qualified. Do not choose it merely because a replacement is labeled 25 A; hold current, minimum trip current, trip delay, voltage, interruption category, and terminal orientation must match. For a new design, prefer a currently supported breaker with verified DC interruption behavior and a documented lifecycle because the SI3069-A-FT is obsolete. A conventional fuse may be suitable only when non-resettable, one-time operation and its time-current curve are acceptable. No exact drop-in substitute was confirmed, so any redesign should begin with a requirements-based component search rather than a footprint-only replacement.

المقارنة مع البدائل

المعامل هذا المنتج
Brand Skyworks Solutions Inc.
Package 2-pin package
Product Type Thermal circuit breaker interface IC
Rated Current 25 A
Maximum AC Voltage 250 VAC
Maximum DC Voltage 50 VDC
Number of Poles 1 pole
Trip Mechanism Thermal
Mounting Type Standard
Lifecycle Status Obsolete

أبرز الفروقات

  • Defined 25 A thermal-breaker rating (مقابلGeneric 25 A fuse)
  • Supports both AC and DC voltage classes (مقابلSingle-voltage breaker)
  • Compact two-terminal integration (مقابلLarger panel-mount breaker)

ملاحظات التصميم

Estimated: the trip point is influenced by I²R heating in the protected path and the thermal resistance from the device to its PCB copper. Using the 25 A rated current and the device resistance R, conductor heating is P = 25² × R; even a small additional resistance can create noticeable heat. Use the manufacturer’s prescribed copper dimensions and avoid placing the breaker beside heat-generating components. Validate the final trip curve in the intended enclosure and ambient range.

The SI3069-A-FT must be placed in the uninterrupted protected-current path rather than on a thin branch that becomes the weakest conductor unintentionally. Use the official land pattern, full recommended copper width, and short return path to the protected load. Avoid long neck-downs, exposed pads, or solder joints with poor wetting because these increase resistance and can shift thermal behavior. Confirm terminal numbering and package orientation mechanically before releasing a PCB revision.

Do not interpret the 25 A marking as permission for 25 A of continuous load without checking the calibration, ambient temperature, conductor capacity, and device mounting method. Also distinguish 250 VAC from 50 VDC: contact interruption behavior differs between AC and DC loads. Because this MPN is obsolete, do not approve a new design solely from a catalog headline; obtain authoritative electrical, thermal, dimensional, and lifecycle documentation for the exact device.

Where the breaker controls a DC inductive load, add the manufacturer-approved flyback or suppression network and confirm that load-generated voltage and current remain within the device’s switching ratings. A 50 VDC supply can produce an inductive arc even when steady-state current is below 25 A. Review the exact contact topology and load category before applying the SI3069-A-FT to motors, solenoids, or relay coils.

معلومات الامتثال

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

The obsolete circuit-breaker device is not an automotive component, so AEC-Q100 is not applicable. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified and remain unknown.

تم التحقق من البيانات في: 2026-11-15 — تم التحقق من البيانات وتنسيقها بواسطة فريق هندسة المكونات في XAIPART

عمليات بحث ذات صلة

SI3069-A-FT datasheet SI3069-A-FT datasheet pdf SI3069-A-FT pinout SI3069-A-FT equivalent SI3069-A-FT replacement SI3069-A-FT cross reference SI3069-A-FT price SI3069-A-FT stock Skyworks SI3069-A-FT 25A thermal circuit breaker SI3069-A-FT 250VAC SI3069-A-FT 50VDC SI3069-A-FT circuit protection SI3069-A-FT footprint SI3069-A-FT obsolete replacement

المكونات والمصطلحات ذات الصلة

Skyworks Solutions Inc. Silicon Labs SI3069-A-FT thermal circuit breaker circuit breaker circuit protection interface IC 1-pole breaker 25 A current rating 250 VAC 50 VDC 2-pin package PCB layout thermal trip trip curve hold current minimum trip current current interruption industrial control power distribution obsolete component drop-in replacement request a quote
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر